RW45 Motor Gearboxes:. Drive torques up to 120Nm at 50 Hz and 60 Hz mains frequencies;

Similar documents
LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

2100/2200/4100/6200 & MPB Series Bottom Mount Drive Pack. for Standard Load Parallel Shaft 60 Hz Gearmotors

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Part-Turn Electric Multi-Turn Electric

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

Vibratory Deck Sieves 15 in. (380 mm)

Up to 85% higher Service Life due to efficient sealing method.

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

SQM40/41 Actuators for air and gas dampers

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

DDF-SE. Application example. Feed-through Stationary Rotary Feed-through. Max. speed 500 revs/ min. Air feed-through Up to 6x

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

KRF EMC Filters Installation, Operation and Maintenance Manual

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

High performance circuit breakers

Electric Rotary Modules. Rotary Actuators

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Caution. Hanging the Screen:

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Revision 1.0 Parts List Minor

MICROMASTER Encoder Module

SPIRAL MIXERS CONTENT CHAPTER 1 COMPANY BRIEF INTRODUCTION OPERATION INSTRUCTION

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

CAVEX hygienic. Stainless steel gearboxes and gearmotors.

RKSlimlift / EM. Two-stage lifting column

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Single Point Flow Monitor SW118 SW119

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

Absolute Encoders Multiturn

Flag System Drop Feeding

Datasheet - SRB301LC 24VAC/DC

Linear flow controls VFC Linear flow controls with actuator IFC

GRUNDFOS alldos product information. The solution for complex dosing tasks

Horn loudspeaker, Ex proof, short/long flare

Revision 2.0 Parts List Minor

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

Revision 1.0 Parts List Salvador 1~, 3~

Step 1. 2x Kep Nut 1x Left Motor Assembly

MVSI-TS. Technical features

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

SLC & SLK. Low-voltage Screwdriver Solutions. More Than Productivity

Revision 2.0 Parts List Minette 1~, 3~

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Gear Pump Units For single-line centralized lubrication systems

EZ-STATUS WLS28-2 Multicolor LED Strip Light

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

EXPlora. Introduction

Low-cost labelling system

INSTRUCTION MANUAL AND PARTS LIST

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

HBM 150/2 L-801 Airport Rotating Beacon Compliant with Standards: FAA: L-801 AC 150/ (Current Edition) ICAO: Annex 14, para 5.3.

OpenAir. Air damper actuators for power and flexibility. Building Technologies

MDT3 and MDT4 Service Parts

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

Assembly instructions

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Revision 3.0 Parts List Salvador 1~, 3~

Immersion Pumps HCT (High Chem) sealless

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Eddy Current Probe System

Selection guide siemens.com/sirius-modular-system

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

Q-TV2. User Manual. for Screens

REGULACE AUTOMATIZACE BOR spol. s r.o.

Gear Pump Units. For single-line lubrication systems

Ordering details. Approval. Classification

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

TECHNICAL INFORMATION

3 Cleaning. 4 Technical data

Typical Roll Shutter Hood* Assembly

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Revision 1.0 Parts List Mega

Small Circular Connector. JN1/JN2 Series. Dust Cap

ASSEMBLY AND INSTALLATION 3 ELEMENT 6 METER BEAM

Magnecraft Power Relays

82540/ /2-way diaphragm valves

TENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Modular Lube Lubrication Systems System Controls

Magnetic Stirrers Magnetic Stirr

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

EC Series Creativity Accessories Safety and Installation Guide

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Transcription:

RW45 Motor Gearboxes Motor gearboxes RW45 Motor Gearboxes The RW45 motor gearboxes are maintenance-free, compact power units for driving ventilation, screen and flap ventilation systems in greenhouses and barns. All RW45 motor gearboxes feature a self-braking worm gear transmission. This transmission ensures that the output shaft is braked when the drive unit is stopped. The combination of carefully matched pinion and worm reductions results in a very quiet mechanical transmission. The RW45 motor gearboxes feature a patented integrated lineair limit system with duty and safety es having a great ing precision. The maximum ing range of the limit system equates to 97 revolutions of the drive shaft. Using the optional installation set with potentiometer, it is possible to precisely feed back the positions of a drive system to a (climate) computer. The RW45 motor gearboxes are finished with a graphite gray powder coating and are supplied including fixing bolts and spring washers. RW45 Motor Gearboxes:. Drive torques up to 120Nm at 50 Hz and 60 Hz mains frequencies;. Rotation speeds from 1 to 5 rpm at 50 Hz, 1.2 to 6 rpm at 60 Hz mains frequency;. Suitable for intermittent use, duty class s3-30%, duty cycle maximum 25 minutes;. Rtted with 12-tooth 1/2"x5/16" zinc-plated sprocket voor chain couplings;. Manual drive enabled by means of hexagon in electric motor shaft;. Electric motors are standard tropic-proof and conform to protection class IP55;. Manufactured standard with 3-phase eurovoltage motors, for use on mains voltages of 400 V at 50 Hz and 480 V at 60 Hz (type A);. Available with 3-phase wide voltage electric motors with CSA approval mark, for use on mains voltages from 208-415 V at 50 Hz and 60 Hz and 415-480 V at 60 Hz (type S);. Available with 3-phase electric motors with CSA approval mark, for use on mains voltage of 575 V at 60 Hz (type C, available on request);. Available with 1-phase electric motors, for use on mains voltage of 230 V at 50 Hz and 60 Hz (type D);. Available with 1-phase electric motors with CSA approval mark, for use on mains voltage from 115-120 V at 60 Hz (type F);. Available with rectified voltage motors, for use on mains voltage of 24 V DC (type H, available on request);. Other specifications and colors available on request. N N N N J: J: J: J: 5 I: 0 0 0 g 0 0 0 It) It) co. " c "'" E o E "2 E "2. 0 I:... <I> 0'1: 0 Ci <I> Z 'E UI UI Co ':0 t: - :::,. " < <I>.&: 1::<1> en < c :E I: :E I: Q. <0; 0 E 502010 RW45-3-09\400-450\3\97 A 90 3,0 90 3,6 3 763010 15,5 502020 RW45-5-09\400-450\3\97 A 54 5,0 54 6,0 3 763010 15,5 535260 RW45-3-09\208-480\3\C\97 B 90 3,0 90 3,6 3 704002. 16,5 535290 RW45-5-09\208-480\3\C\97 B 54 5,0 54 6,0 3 704002. 16,5 502040 RW45-3-09\220-240\ 1\97 D 90 3,0 80 3,6 1 701001 16,5 502050 RW45-5-09\220-240\ 1\97 D 54 5,0 50 6,0 1 701001 16,5 502036 RW45-3-09\ 110-115\ 1\60\C\97 F 70 3,6 1 701202. 16,5 502037 RW45-5-09\ 110-115\1\60\C\97 F - 45 6,0 1 701202. 16,5 EJ (IDBB OOB B B

Motor gearboxes Dimension drawings RW45 Motor Gearboxes ~ 150 11 12 200 ~i M20 (2x) 28 245 m 11 12 h1 h2 Art. no. Description (kg) (mm) (mm) (mm) (mm) 502010 RW45-3-09\400-450\3\97 15,5 170 54 144 502020 RW45-5-09\400-450\3\97 15,5 170 54 144 535260 RW45-3-09\208-480\3\C\97 16,5 156 55 141 535290 RW45-5-09\208-480\3\C\97 16,5 156 55 141 502040 RW45-3-09\220-240\ 1\97 16.5 156 148 55 167 502050 RW45-5-09\220-240\ 1\97 16,5 156 148 55 167 502036 RW45-3-09\ 110-115\1\60\C\97 16,5 157 204 53 175 502037 RW45-5-09\ 110-115\1 \60\C\97 16,5 157 204 53 175 Straight mounting plates for RW45 Mounting plates Dimension drawings 11(4x) stc. 85 I I..,. --t--in \ I / 1 b I 75 I JL m b I Art.nr. Omschrijving (kg) (mm) (mm) 414969 MOUNTING PL 85\B195\BL 1,3 195 270 414970 MOUNTING PL 85\B195 1,3 195 270 414971 MOUNTING PL 85\B483.5 3,8 483,5 558,5 414972 MOUNTING PL 85\B503.5 3,9 503,5 578,5

I, I Mounting positions for RW45 motor gearboxes RW Motor Gearboxes: Mounting Technical information

RW Motor Gearboxes: RSU Limit system RSU Limit system: Settings Technical information Operating Safety Operating Safety a b ----- - - - 0' z z 0 z z 0 z z 0 z z 0 7 L '" '" w '" w 0'" 3., a: "., 3., a: "., 3., a: "., " a: :5 " RSU limit system installation The steps required in order to correctly set the RSU limit system of an RW motor gearbox, described below. are Current and voltage range The contacts in the es of the Ridder RSU limit system, are capable of ing the following currents:. 24 V-AC, currents from 45 ma to 130 ma;. 230 V, currents up to 1 A. Ridder RSU limit system The Ridder RSU limit system is a linear system, specifically designed for use in the RW motor gearboxes. The limit system is driven by the output shaft of the motor gearbox, via a secondary transmission. Depending on the type of motor gearbox, a number of revolutions of the output shaft can be set, between a starting and ending position. Depending on the type of motor gearbox, this will be 55, 86, 97 or 860 revolutions of the output shaft. How it works This transmission drives the threaded shaft (1) of the Ridder RSU limit system, either with a toothed belt, or with a worm and gear combination. When running, the threaded followers (4) will move along the threaded shaft as it rotates. One setscrew (a) rests against the spring (6). When an end position is reached, the follower will strike the stop (7) and will then rotate with the threaded shaft. This deflects the spring, and a duty (S11 or S12) will be tripped. This causes a signal that activates the relay, stopping the motor gearbox. Should a relay or duty fail, then a safety (ES21 or ES22) will also be tripped by the spring. This causes a signal that activates a safety relay, stopping the controller and also thereby the motor gearbox. This prevents consequential damage to the driven system. Delivery A Ridder motor gearbox with RSU limit system is delivered with followers (4) whose adjustment rings (3) still have to be fastened. This means that the drive can turn freely in both directions. This also avoids the possibility of causing damage to the limit system (when it has not yet been connected), should any (preset) limiting positions be exceeded during electrical or manual operation of the motor. I Connection When connecting the Ridder RSUlimit system, pleasereferto the wiring diagrams provided for this purpose.

RW Motor Gearboxes: RSU Limit system Technical information Setting The "start position" and "end position" are set as follows: 1. By rotating the output shaft (manually or under power), bring the system to the "start position" or "end position" and determine which duty (ES11 or ES12) should be tripped. The ing sense of the RSU limit system can be reversed by swapping connections 1 and 7 in the connection block. 2. Turn the milled bush (2) on the appropriate side, "hand tight" up to the stop (7). The milled bush can easily be screwed by hand along the threaded shaft (1). The follower (4) also moves along the threaded shaft. 3. Now rotate the adjustment ring (3) over the milled nut just far enough to trip the duty. 4. Then fasten the adjustment ring with setscrews (a and b) firmly on the milled nut. The adjustment ring can no longer be rotated over the milled nut. 5. Repeat items 1 through 4 to adjust the limit system for the opposite This completes rotation direction. the setting of the limit system. Caution Take care: Once an RSU limit system has been set and the motor gearbox is operated manually, always make certain that the limiting positions set by the limit are never exceeded. This can seriously damage the limit system, such that the limit system no longer functions correctly!

Maintenance of RWmotor gearboxes RW Motor Gearboxes: Maintenance Technicalinformation Maintenance RW45motor gear boxes Regularly check your motor gearbox for operation performance and possible grease leakage. Inform your instaler in case of grease leakage. Maintenance RW240/400/600-RW1 000/1200S/1400/1600S-RW200 motorgear boxes Regularly check your motor gearbox for operation performance and possible grease leakage. Inform your installer in case of grease leakage. Beware: When mounting place the vent plug in the highest position possiblel RW45 RW240/400/600 RW1000/1400 RW200 Oil Ridder EPX Ridder EPX Ridder EPX Grease Ridder SPH Contents 0,9 kg 1,151 1,51 1,1 I