Operating Instructions for Throttle Valves Using VRC Valve Positioner

Similar documents
HS-509 VIBRATION TRIP MODULE

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Installation and Operating Instructions. Vari-Watt Power Controller

Sentinel I24 Digital Input and Output Configuration

Model R177M and R177S Baseband Switch

Operating Instructions

Flat-Bed Module Recorders

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

RF Wireless Receiver (Model S4PU-DC-ANT3)

Understanding VFD. Variable Frequency Drive. nfi. nfi

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

SQM40/41 Actuators for air and gas dampers

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SCALE & WEIGHT DISPLAYS

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

263 Series LED Bargraph Indicator and Controllers

4x4 Component Audio Matrix

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

Systems Pow-R Breakers Renewal Parts and Accessories

EA350. Generator Automatic Voltage Regulator Operation Manual

LAUREL ELECTRONICS, INC.

Integre4. Audiophile integrated amplifier. v1.2

PicoBoo PLUS. OPERATING MANUAL V1.1 (Sep 8, 2011) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: or

4x4 Component Matrix over CAT-5

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

isync HD & isync Pro Quick Reference Guide isync HD isync Pro Digital Video Processor and Video/Audio Switcher

Junior Max (JR Max ) Controller

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

DM1624, DM1612, DM812

AUTOMATIC VIDEO LOSS A/B SWITCH

SRV02-Series. Ball & Beam. User Manual

Standard signal metering in wall-mounting case

BooBox Flex. OPERATING MANUAL V1.1 (Feb 24, 2010) 6 Oakside Court Barrie, Ontario L4N 5V5 Tel: Fax:

ADAT DC Coupling Modifications for Laser Graphic Recording

6-DIGIT FREQUENCY METER, TACHOMETER, RATE METER, TIMER, PULSE TOTALIZER, PROCESS METER & TOTALIZER WITH RS-232 PENTA P6000

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Wall-/Pipe-Mount Level Indicator

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

Butterfly Valve Retrofits

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

QUICK START GUIDE FLEXSLICE MODULES

DCP100 Digital Control Programmer Specifications

Setting up the Setting up the Dragonfly 1 v June

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

NewScope-7A Operating Manual

Model P/03P Upconverters

SRV02-Series. Rotary Pendulum. User Manual

Standard RS232 RS ma

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Field Service Procedure Replacement GACP Control Panel Kit, ST24

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

RSL MusicPower Plug-In Installation Manual For Naim NAC 72 Preamp

Lt DELTA USA, Inc

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

RMX-44 & RMX-62 MIXING MATRIX. Installation & Operation Manual

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

DMC550 Technical Reference

TeamWork Installation Guide

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

EVC300i. Generator Automatic Voltage Regulator Operation Manual

C-net WIND. User s Guide

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Instruction Manual Model BlockUpconverter

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

CAT EXT-CAT USER MANUAL

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

TeamWork Kits Installation Guide

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Instruction Manual Model # Block Upconverter

Direct PWM. 1000/2000 Series POWERBLOK MODULE

Your First Choice for Control Systems Solutions

Professional Fidelity Mastering Grade Listening

Process Transmitter RMA 422

Model 1476-C SuperQuad HR

Caution. Hanging the Screen:

Solid-State Digital Timer

TELEDYNE HASTINGS INSTRUMENTS

Telemetry Receiver Installation Guide

Precision Linear Motor / Stepper Motor Stage Reference Manual (Open and Closed Loop Versions)

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

Transcription:

ThrottleMaster TM Operating Instructions for Throttle Valves Using VRC Valve Positioner p/n: X709116 $10.00 3/2012 Throttlemaster is a registered trademark of Vacuum Research Corporation

Introduction The Throttlemaster positioner/indicator drives a fast response servo motor to position the valve s gate carriage assembly from 0 to 100% of full travel using either a 0 to 10 vdc or a 4 to 20 ma signal depending on the design of your system. The motor may be a 1 phase or 3 phase type. Wiring diagrams for connection of the positioner/indicator to both types of motors are shown in this manual. The rotary position sensor is mounted on the face of the motor housing and is directly coupled to the motor shaft to provides stepless resolution of the valve position. The balancing of the feedback signal positions the gate/carriage assembly along its full range of travel 0 to 100% to +/-.1%. Local and Remote Operation The user can control the valve position from the positioner front panel or from a remote location. The Local / Remote Switch on the front panel of the Throttle Valve Positioner allows the user to select either: 100.0 Local Remote 1. Local control of valve position using the front panel three digit push button selector on the positioner front panel. 2. With the front panel toggle switch in the Remote position the valve will be controlled by a signal connected to the rear panel of the positioner. 2 a) This signal can be provided by the computer or PLC controlling the vacuum process. b) The signal can be provided by the optional hand held remote pictured to the right. The hand held remote communication signal may be 0 to 10 vdc or 4 to 20 ma depending on cable length. Longer cable length requires a current loop signal to overcome the inherent cable resistance. c) For 3 position operation, as is common for sputtering, the signal may come from any manually adjusted 0 to 10 VDC power supply. d) The signal may be the 0 to 10 VDC output of a PID or other controller with an analog output. Optional Hand Held Control: Full open, Full close or 0 to 99.9 % of Gate Carriage Travel

0 to 10 VDC or 4-20 ma Remote Input The Remote Input can be either a 0 to 10 VDC or a 4 to 20 ma current loop signal to control the gate position of the valve gate from OPEN (00.0) to CLOSED (100.0). Positioners are shipped from the factory ready to accept a 0 to 10 VDC signal unless otherwise requested. VRC Hand held remote units are configured as 4 to 20 ma. Follow the steps below to program your Valve Positioner to operate from a 4 to 20 ma remote signal 1. Unplug the AC line power and black and green connectors from the rear panel of the Throttle Valve Positioner. 2. Using slotted screwdriver, remove 2 screws from the top front and 4 screws from the bottom of the outer case. 3. Slide outer case back towards the rear. 4. Locate the 4 position DIP SWITCH which is located towards the rear, and under the fuse. Configure as shown for 4 to 20 ma. 5. Connect a 20 ma signal to the rear panel terminal and adjust OFFSET pot on the rear panel until the display reads 99.9 to 100.0%. DIP Switch Number 1 2 3 4 0 to 10 Volt DC OFF OFF ON ON 4 TO 20 ma ON ON OFF ON Note: When using a VRC Hand Held Positioner the remote input settings for the dip switch must be set to the 4 to 20 ma settings. To return to 0 to 10 Volt signal follow these steps: 1. Configure the dip switch as shown for 0 to 10 VDC. 2. Connect a 10 Volt DC signal to the rear panel terminal and adjust OFFSET so the display reads 99.9 to 100.0%. Relay Setpoints Relay setpoints are adjustable over the entire range from 0 to 100% of valve position travel. Factory settings are 0% for full open and 100% for full closed valve travel. The adjustments are located on the rear panel. To adjust the setpoints select Local with the front panel toggle switch, and with the front panel pushbuttons move the valve to the position at which you wish the alarm relay to change state. Then, slowly turn the rear panel adjustment potentiometer until you hear the relay click. Resume normal operation. Anytime that the valve reaches the value you have selected the SPDT relay will change state. Valve Positioner 115/220 V Operation (motor voltage must be specified at time of ordering) 220 to 240V, 50/60 HZ (Brown Wire) 115V, 50/60 HZ (Brown Wire) JUMPER TRANSFORMER WIRED FOR 220/240V 50/60 HZ OPERATION JUMPER TRANSFORMER WIRED FOR 115V 50/60 HZ OPERATION JUMPER NEUTRAL (Blue Wire) NEUTRAL (Blue Wire) EARTH GROUND (Green/Yel. Wire) EARTH GROUND (Green/Yel. Wire) 3

Vacuum Research Corp. 2419 Smallman Street Pittsburgh, PA 15222 USA (800) 426-9340 (412) 261-7630 FAX: (412) 261-7220 e-mail: VRC@vacuumresearch.com Wiring Diagram for Positioner to Single Phase Motor