IKA Analytical line Calorimeters C 2000

Similar documents
Model KBF 115 Constant climate chambers with large temperature / humidity range

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Model KT 53 Cooling incubators with thermoelectric cooling

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model KBF 720 Constant climate chambers with large temperature / humidity range

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model KT 170 Cooling incubators with thermoelectric cooling

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Cooling systems for ORBIMAT

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

Mechanical flow switch for On/Off control

Model ED 400 Drying and heating chambers Classic.Line with natural convection

GRUNDFOS alldos product information. The solution for complex dosing tasks

Linear flow control with actuator IFC

LABSONIC M The ultrasonic homogenizer for every application. Benefits

Nessie Coils for VDH and VDHT valves

AUTOMATIC COVERSLIPPER CVR909. Date of issue: 21/03/2019 Rev. 04

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

Manufacturer since 1873

721N Spectrophotometer. Operating Manual

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

DM 50 / DM / 2- component dosing and mixing system. engineering

Product Data Sheet 8506 VW-691

Bimetal Temperature Switch

Level Measurement silometer FMC 420, FMC 423

Linear flow controls VFC Linear flow controls with actuator IFC

Capacitance Limit Detection nivotester FTC 420/421/422

Product Data Sheet 4656 EZ

IP Roombox. Hotel Room Management

Product Data Sheet 4656 ZW

Single Point Flow Monitor SW118 SW119

Coils for solenoid valves

Actuators IC 20, IC 40

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Accessories. Servo Motors. Servo Motors B-47. Accessories

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

VarioSynergic 3400 / 4000 / 5000 VarioSynergic / / MIG/MAG welding PERFECT WELDING

Panel-mounting thermostats, type series EM

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Safe Enclosure Cooling

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

DMP 331i / DMP 333i LMP 331 i

TUC: Universal thermostat

Catalogue Ignitors and power switches for HID

Engineered to meet your needs T he oldest name in stud welding,

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

7 Lighting Technology

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Solenoid valves VZWD, directly actuated

InSight Pro. Valuable real-time process insight

istep STEPPER MOTOR PUMP

3. Fibre Gripper - Includes a simple adaptor to fit 70mm glass slides to the OFDA 4000 for measuring fibre snippets (not shown)

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

IMPAC Infrared Thermometers

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

82540/ /2-way diaphragm valves

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

An impressive appearance

Viper Ex the hazard free way to precise weighing results. Ex ia. The intrinsically safe compact scales combine leadingedge

TOSHIBA Industrial Magnetron E3328

LAUREL ELECTRONICS, INC.

HICUBE. The modular pumping stations for all applications in high and ultra-high vacuum

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

LED Driver Compact dimming

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

Solenoid valves VZWD, directly actuated

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Capsule Filling and Closing Machine GKF 2500 ASB - GKF 2500 ASB IPK - GKF 2500 ASB 100%

Benchtop performance in a compact footprint

PRINCIPLES AND APPLICATIONS

Label Applicator HERMA 400

Agilent 87075C Multiport Test Set Product Overview

Modular Lube Lubrication Systems System Controls

3B SCIENTIFIC PHYSICS

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Product Data Sheet 4650 N-465

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

Transcription:

Calorimeters C 2000 Analytical line Calorimeters 140 C 2000 basic,, C 2000 basic high pressure and high pressure The C 2000 basic and calorimeters are the newest systems from IKA for determining gross calorific values of liquid and solid samples. A high level of automation with extremely simple handling characterizes these instruments. In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available. Halogen resistant decomposition vessels of the C 5012 series for quantitative decomposition of sulfur and halogens in parallel to determining gross calorific values are available. To provide the calorimeters with cooling water, they need to be connected to a thermostat like the KV 600 (page 131) or a firmly installed water connection. The C 2000 basic is equipped with a very convenient console to operate the unit. The is delivered with the proven C 5040 CalWin calorimeter software in order to control the system via PC. Network connection and special configuration for data exchange with LIMS can be implemented at any time. The C 2000 high pressure is a combination of the C 2000 basic / and the C 62 digestion container (up to 1200 bar operating pressure), see page 147. Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel Automatic oxygen filling of decomposition vessel Automatic decomposition vessel identification Automatic sample ignition Validation according to DIN 51900, ASTM 240 D, ISO 1928, BSI etc. GHOST-certified Working methods: isoperibol, measurement time: approx. 22 min dynamic, measurement time: approx. 7 min Compact, integrated modular design for convenient operation Cooling water supply via thermostat (KV 600) or firmly installed water connection (C 25 pressure regulating valve recommended, page 147) Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 (page 147) User-friendly software C 5040 CalWin for controlling the calorimeter and administration of measuring data (page 146) LIMS integration is possible Special halogen resistent vessel for quantitative decomposition of halogens and sulfur The decomposition vessel can be changed over to use disposable crucible C 14 burns during measuring (page 148) Up to 8 calorimeters can be conrolled by a single PC, using a multi-serial plug-in card (see C 5041 CalWin plus, page 146) Power input 1,8 kw Power ON-time permanent operation Protection class acc. to DIN EN 60529 IP 21 ambient temperature 20-25 C ( constant) humidity 80 % 440 x 450 x 500 mm Weight 30 kg Working range 40.000 J Reproducibility based on analysis of 1 g isoperibol 0,05 % RSD benzoic acid NBS 39i dynamic 0,1 % RSD Working modes isoperibol 25 C isoperibol 30 C dynamic 25 C dynamic 30 C Measurement time: isoperibol up to 22 min dynamic up to 7 min Operating oxygen pressure 30 bar Cooling medium tap water Min. flow rate 60 l/h Operated with KV 600 Cooling water supply: Pressure 0,3 bar Temperature (depending on working mode) 18 / 25 C Operated at firmly installed water connection: Pressure after C 25 pressure regulating valve 1-1,5 bar Temperature (depending on working mode) 12-28 C Max. pressure at the tap 6 bar

Calorimeters C 2000 C 2000 basic version 1 C 2000 basic C 2000 basic high pressure C 2000 basic C 62 Decomposition vessel, high pressure C 60 Conversion set C 2000 basic version 2 C 2000 basic C 5012 Decomposition vessel, halogen resistant 16.236,00 AC Version 1 8801800 230 V 50/60Hz 8801801 115 V 50/60 Hz 18.592,00 AC Version 2 8801900 230 V 50/60 Hz 8801901 115 V 50/60 Hz 17.583,00 AC basic high pressure 8802300 230 V 50/60 Hz 8802301 115 V 50/60 Hz version 1 C 5040 CalWin, calorimeter software version 2 C 5012 Decomposition vessel, halogen resistent C 5040 CalWin, calorimeter software A PC or Notebook is required to operate the high pressure C 62 Decomposition vessel, high pressure C 60 Conversion set 17.114,00 AC Version 1 8802000 230 V 50/60Hz 8802001 115 V 50/60 Hz 20.024,00 AC Version 2 8802100 230 V 50/60 Hz 8802101 115 V 50/60 Hz control high pressure 8802400 230 V 50/60 Hz 8802401 115 V 50/60 Hz C 2000 Extension device max. 8 devices (without calorimeter software, without decomposition vessel), C 5041.10 Connection cable (for 8x interface box) 14.328,00 AC 8802200 230 V 50/60Hz 8802201 115 V 50/60 Hz 141

Calorimeters C 5000 C 5000 control and C 5000 duocontrol The IKA calorimeter C 5000 is the only calorimeter in the world that offers a free selection of 3 working methods: Thus it is possible to perform determinations of gross calorific values of liquid and solid samples in adiabatic (approx. 14-18 min), isoperibolic (approx. 22 min) and dynamic (reduced time: approx. 10 min) mode. A high level of automation in addition to an extensive range of accessories leave nothing more to wish for. Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel Automatic oxygen filling and degassing of the decomposition vessel Automatic decomposition vessel identification Validation according to DIN 51900, ASTM 240 D, ISO 1928, BSI etc. GHOST-certified Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 (page 147) User-friendly software C 5040 CalWin for controlling the calorimeter and administration of measuring data (page 146) LIMS integration is possible Special halogen resistent vessel for quantitative decomposition of halogens and sulfur The decomposition vessel can be changed over to use disposable crucible C 14 burns during measuring (page 148) The C 5000 control can be expanded to the duocontrol system with two measurement cells at any time Power input (with one measuring cell) Power ON-time Protection class acc. to DIN EN 60529 1,3 kw permanant operation IP 21 ambient temperature 20-25 C ( constant) humidity Weight Working range Reproducibility based on analysis of 1 g benzoic acid NBS 39i Working modes 80 % 41 kg 40.000 J adiabatic / isoperibol 0,05 % RSD dynamic 0,1 % RSD adiabatic Measurement time: adiabatic isoperibol dynamic isoperibol dynamic up to 15 min up to 22 min up to 10 min Operating oxygene pressure Cooling medium (C 5004) Flow rate 30 bar tap water 70-140 l/h Operated (C 5004) with KV 600: Temperature 16-20 C Operated at firmly installed water connection: Min. / max. temperature Max. pressure at the tap 15 / 19 C 9 bar 142

Calorimeters C 5000 C 5000 control package 1/10 C 5003 Measurement cell C 5001 Cooling system C 5000 control package 1/12 C 5003 Measurement cell C 5012 Decomposition vessel, halogen resistant C 5001 Cooling system 740 x 380 x 400 mm 23.593,00 AC Package 1/10 8801000 230 V 50/60Hz 8801001 115 V 50/60 Hz 26.505,00 AC Package 1/12 8801500 230 V 50/60 Hz 8801501 115 V 50/60 Hz C 5000 control package 2 /10 Cooling water supply via thermostat KV 600 (page 147) or firmly installed water connection. C 5003 Measurement cell C 5004 Heat exchanger C 5000 control package 2/12 Cooling water supply via thermostat KV 600 (page 147) or firmly installed water connection. C 5003 Measurement cell C 5012 Decomposition vessel, halogen resistent C 5004 Heat exchanger 560 x 380 x 400 mm 21.201,00 AC Package 2/10 8801200 230 V 50/60Hz 8801201 115 V 50/60 Hz 23.741,00 AC Package 2/12 8801600 230 V 50/60 Hz 8801601 115 V 50/60 Hz C 5000 duocontrol package 3/10 System with two measurement cells. C 5003 Measurement cell (2 pieces) (2 pieces) C 5002 Cooling system 1.440 x 380 x 400 mm C 5000 duocontrol package 3/12 System with two measurement cells. C 5003 Measurement cell (2 pieces) C 5010 Decomposition vessel, halogen resistant (2 pieces) C 5002 Cooling system 43.229,00 AC Package 3/10 8801100 230 V 50/60Hz 8801101 115 V 50/60 Hz 48.396,00 AC Package 3/12 8801700 230 V 50/60 Hz 8801701 115 V 50/60 Hz 143

Calorimeters C 7000 C 7000 The C 7000 is the first IKA calorimeter with a completely dry system for measuring the gross calorific value of solid and liquid samples. The temperature is measured directly in the decomposition system. This results in measurement times in the range of 3 to 7 minutes (depending on the sample). The system can manage up to 8 different decomposition vessels using a code ring scheme. High sample frequency Precise and reproducible determination of gross calorific values according to ISO 1928 Reduction of routine work through automatic application flow Automatic decomposition vessel identification Interface connections for scale, printer and PC User-friendly software C 5040 CalWin for controlling the calorimeter and administration of measuring data (page 146) Special halogen resistent vessel for quantitative decomposition of halogens and sulfur The decomposition vessel can be changed over to use combustible crucibles C 14 burns during measuring (page 148) Power input Power ON-time Protection class acc. to DIN EN 60529 ambient temperature humidity Weight (C 7000 and C 7002) Working range Reproducibility based on 1 g benzoic acid NBS 39i Working mode Measurement time Operating oxygen pressure Cooling medium (C 7002) Flow rate (C 7002) Temperature Max. pressure at the tap 0,1 kw permanent operation IP 21 18-30 C (constant) 80 % 310 x 490 x 460 43 kg 30.000 J 0,2 % RSD patented double dry working procedure 3-7 min 30 bar tap water 2-3 l/min 12-30 C (cooling water) 9 bar 144

Calorimeters C 7000 C 7000 basic equipment set 1 C 7000 Measurement cell C 7010 Decomposition vessel, standard C 7002 Cooling system C 48 Oxygen station 21.201,00 AC 8800900 230 V 50/60 Hz 8800901 115 V 50/60 Hz C 7000 basic equipment set 2 C 7000 Measurement cell C 7012 Decomposition vessel, halogen resistent C 7002 Cooling system C 48 Oxygen station 23.404,00 AC 8801400 230 V 50/60 Hz 8801401 115 V 50/60 Hz 145

Software calorimeters C 5040 CalWin CalWin is a control and evaluation software for all IKA calorimeters (C 2000, C 4000, C 5000, C 7000). Requires a PC running any of the following operating systems: Windows 95 / 98 / ME / NT / 2000 or XP, and at least one free serial interface and 50 MB of available disk space. Control, monitor and view working procedures Print and save measurement protocols Identify and record samples Administration of sample racks Flexible administration and evaluation of calibrations Flexible aministration and grouping of measurements Printing and saving calibration and result protocols suitable for certification Library functions Data transfer through COM to EXCEL and ACCESS Preprocessed work sheets for EXCEL (configarable by the user) Preis / Ident. No. 1.735,00 AC 3045000 C 5041 CalWin plus To control up to 8 calorimeters of the same or different type. C 5040 CalWin, PCI 8.2 PC Plug-in card (internal), Interface box (8x) Preis / Ident. No. 1.918,00 AC 3166000 146

Calorimeters accessories Accessories Comments Ident. No. for C 2000 / C 5000 7114000 C 5012 Decomposition vessel, halogen resistant for C 2000 / C 5000 7215000 C 62 Decomposition vessel, high pressure for C 2000 3265000 C 5010.4 Attachment for combustible crucible C 14 for C 5010 / C 5012 3016900 C 5010.5 Crucible holder, big for C 5010 / C 5012 3055900 C 5030 Venting station with gas wash bottle acc. to DIN 12596 (for gas absorption) for C 5010 / C 5012 7198000 C 5020 Sample rack for C 2000 / C 5000 7145000 KV 600 Cooling water supply (230 V) KV 600 Cooling water supply (115 V) C 25 Pressure regulating valve to operate with firmly installed water connection C 5041.10 Connection cable C 21 Pelleting press C 29 Pressure gauge, oxygen C 7010 Decomposition vessel, standard C 7012 Decomposition vessel, halogen resistant for C 2000 3410500 3410501 3197200 3036000 1605300 0750200 3015000 3017000 C 48 Oxygen station 1560000 C 7010.8 Venting handle for C 7010 / C 7012 7095000 C 7030 Venting station with gas wash bottle acc. to DIN 12596 (for gas absorption) for C 7010 / C 7012 3013300 C 7002 Cooling system (230 V) 7011000 C 7002 Cooling system (115 V) 7011001 Instructions on the IKA calorimeter systems, on request 147

Calorimeters consumables Consumables for all Calorimeters Comments Ident. No. C 5003.1 Aqua Pro stabilizing agent 30 ml 7207700 C 710.4 Cotton thread, cut to length 500 pieces 1483700 C 5010.3 Ignition wire, spare 5 pieces 7122800 C 5012.3 Ignition wire, platinum 2 pieces 2994900 C 4 Quartz dish 1695500 C 5 Set of VA combustion crucibles 25 pieces 1749500 C 6 Quartz crucible, big 0355100 C 9 Gelatine capsules 0749900 C 10 Acetobutyrate capsules C 12 Combusion bags 40 x 35 mm C 12 A Combusion bags 70 x 35 mm C 14 Combustible crucible C 15 Paraffin strips C 43 Benzoic acid NBS 39i C 43A Benzoic acid C 723 Benzoic acid, blister package 600 pieces 30 g 100 g 50 pieces 0750000 2201400 2201500 7224500 3131100 0750600 0750700 3243000 AOD 1.11 Control standard for sulfur and chlorine 50 ml 3044000 AOD 1.12 Control standard for fluorine and bromine 50 ml 3080200 C 62.1 Set of wearing parts (for C 2000 high pressure) 3296300 C 62.2 Combustion crucibles for C 62 (for C 2000 high pressure) 3266000 C 08 Pure iron ignition wire (for C 2000 high pressure) 200 m (coil) 0749600 148