CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, Contents

Similar documents
Weschler AMT Software for the Enhanced Version Transformer Advantage

SPIRIT. SPIRIT Attendant. Communications System. User s Guide. Lucent Technologies Bell Labs Innovations

VIDEO ALARM VERIFICATION UNIT VIVER

Training Note TR-06RD. Schedules. Schedule types

RF Solution for LED Display Screen

Network Camera Operating Manual

Transmitter Interface Program

Honeywell HomMed Wireless Scale Quick Reference Guide

1 OVERVIEW 2 WHAT IS THE CORRECT TIME ANYWAY? Application Note 3 Transmitting Time of Day using XDS Packets 2.1 UTC AND TIMEZONES

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Intelligent Security and Fire Ltd

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

IP Broadcasting System. User manual

Operating Instructions

This document contains the latest information about the new Polycom VS4000 TM model, running 5.1 software.

Revision Protocol Date Author Company Description 1.1 May 14, Seth LOUTH Revised for formatting

Managing a Time Clock Station

Redcare signal strength tester user manual.

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

DCD-24 Word Clock Distributor

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

DL-Navigator Operator Manual Post-Network Conversion (Version 6.1) Wisconsin BadgerNet Converged Network Room Control System- Pre-Network Conversion

DVB-T Box, USB Monheim/Germany Tel. +49 (0)9091/ Fax +49 (0)9091/ Hama GmbH & Co KG.

RADview-PC/TDM. Network Management System for TDM Applications Megaplex RAD Data Communications Publication No.

Mortara X-Scribe Tango+ Interface Notes

Operating Instructions

My XDS Receiver- Affiliate Scheduler

AUTOMATIC VIDEO LOSS A/B SWITCH

My XDS Receiver- Affiliate Scheduler

Universal Voice Logger

VNS2210 Amplifier & Controller Installation Guide

User s Manual. Network Board. Model No. WJ-HDB502

TransitHound Cellphone Detector User Manual Version 1.3

American DJ. Show Designer. Software Revision 2.08

The amazing power of FiOS starts here.

Quick Guide XCAL-Harmony v2

Rack-Mount Receiver Analyzer 101

RADview-PC/TDM. Network Management System for TDM Applications Megaplex-2100/ RAD Data Communications Publication 06/03

Modbus for SKF IMx and Analyst

PYROPTIX TM IMAGE PROCESSING SOFTWARE

CHOICECONNECT 100W ENDPOINT OVERVIEW

Crestron TPMC-4SM Fusion RV Interface Operations Guide

WV-NP1004. Network Operating Instructions. Network camera. Model No. (Lens is option.)

The Diverse Multimedia & Surveillance System Via Dico2000 with PC DICO Operation Manual

Spektrum AirWare Change Log 2016-November-15

US Rev. E, Copyright 1 September 2008 CAUTION:

X-Sign 2.0 User Manual

DeviceConfig. User Guide. Camera configuration tool (RS232, GigE, Camera Link) V April 2012

Rogers Enhanced Guide

Operating Instructions WV-NS950, WV-NS954 WV-NW960, WV-NW964

SONARtrac Technical Bulletin

UHF REMOTE RECEIVER INSTALLATION & PROGRAMMING

Click Here To Start Demo

DXI SAC Software: Configuring a CCTV Switcher. Table of Contents

RADIO FREQUENCY SYSTEMS

Application Note 11 - Totalization

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference.

Instructions for DataMark PDF Temperature Logger

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

SNG-2150C User s Guide

HydraScan. Configuration Software for Thermo Scientific Doppler Flowmeters User Guide P/N Part of Thermo Fisher Scientific.

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

VNS2200 Amplifier & Controller Installation Guide

MULTI CHANNEL VOICE LOGGER MODEL PCVL - 4/8/10/16/32/64. ORIGINAL EQUIPMENT MANUFACTURER OF VOICE LOGGING SYSTEMS Radio and CTI Expert Organisation

Warranty Information

This document last edited May 2015 for version Some commands may not be available in previous versions of firmware.

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

GWL/ Power Group Technology Solutions Stay Powered for the Future

MSC+ Controller. Operation Manual

CG-1 CAMERA-GUARD INSTRUCTION BOOK IB647501

SELENA GPS ATOMIC CLOCK ( Option # 725GPS )

APPLICATION NOTE 4254 PRBS Mode Setup for the MAX9257/MAX9258 Evaluation Kit

Casambi App User Guide

Philips StressVue Tango M2 Interface Notes

Amino. Digital Television. Sun City & Hilton Head Island

MXS Strada USER GUIDE

Ford AMS Test Bench Operating Instructions

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs

Installation Instructions

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

DM-TX-201-C DigitalMedia 8G+ Transmitter. Supplemental Guide Crestron Electronics, Inc.

Rack mounted telephone- and leased line modem for industrial applications

MB5 Multibeam Activity Monitor

Revision Protocol Date Author Company Description January Paul DOS REMEDIO S. Imagine Communications

Watchman. Introduction: Door Lock Mobile MAX

KF200 PORTABLE MANUAL

Birdie-FTR FaulTracker

Data Acquisition Instructions

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

WaveMaker III Gartech Enterprises Inc. 12/17/2012

SPP-100 Module for use with the FSSP Operator Manual

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

REMOTE DISPLAY WIRELESS DECODER MK II

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Configuration Guide Comtech EF Data Satellite Modems

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

Transcription:

F. S. BRAINARD & COMPANY PO Box 366, 5 Terri Lane Unit 15, Burlington, NJ 08016 tel: (609) 387-4300 fax: (609) 387-4304 www.meter-master.com email: cellosupport@meter-master.com CELLO SETUP WITH WinGPS CelloSetup_WinGPS(15.9).doc September 17, 2015 Set Up Logger (pages 2-3) Install Program On Computer 1. Register SIM card (if new SIM) Contents 2. Configure Logger (only if adding/subtracting channels or corrupt notepad) 3. Verify Cello Time ( General tab) 4. Enter Site Name and PMAC ID ( General tab ) Site name and number Unique PMAC ID 5. Enter Channel Information and Test Input ( Channels tab) Channel names Scale factor and units for each channel Logging Intervals ( Rate ) for each channel Test input for each channel Zero the pressure value if necessary Alarm Threshold for each channel (if using alarms) 6. Enter Dialout Settings ( Remote Comms tab) Enable dialout Set frequency Set dial-out time If encoder, enable to send index registers Enter phone to call 7. Start Logging ( General tab ) Other Tasks (page 4) Signal Strength and SIM Card Tests View Cello Log (for troubleshooting) Send Setup Info And Monitor Outgoing Data (for troubleshooting) Manually Upload Recent Data Download ( Read ) Data View Modem and SIM Info (e.g., modem IMEI and serial numbers) Images (pages 5)

F. S. Brainard & Co.: Cello Setup with WinGPS 2 Install Program On Computer SETUP LOGGER 1) Setup.exe and WinGPS Installer.msi should be in the same directory on your computer. 2) Run Setup.exe. 3) Change COM port as necessary (in Options under Tools in the menubar). Set Initial comms rate = 1200; Max comms rate = 9600; Logger detection = Manual. 4) Should you need to change the configuration file for your logger, you may need to change the Configuration files directory to the Config directory under Programs. 1. Register SIM Card (if new SIM) Cello SIM cards must be modified before they will send messages. With SIM card in Cello and Cello connected to computer: 1) Close WinGPS so COM port is free 2) Run InitializeSIM_ver2.bat (in the InitializeSIM folder). 3) Follow instructions on screen 2. Configure Logger (only if necessary) (only if adding/subtracting channels or corrupt notepad) 1) In the menubar under Logger, press "Configure". 2) Select directory, then config file (*.cfg). To understand file names, see NamingFiles.txt IMPORTANT: Whenever you reconfigure a Cello, certain Dialout Settings (#6) are automatically reset to their default values. Check and, if necessary, reenter values for: (a) Dial-Out Time, and (b) Send Index. 3. Verify Cello Time ( General Tab) Cello uses the cellular network to automatically adjust its internal clock to the nearest minutes and seconds. However, hour must be set by user. To set clock to some other time besides the computer time (e.g., to compensate for daylight savings), temporarily change your computer clock before starting WinGPS. To sync Cello clock to PC time, press "Set Clock. 4. Enter Site Name And PMAC ID ( General Tab ) 1) Enter Site Name of own choice (Site Number is optional). 2) Enter 4 or 5 digit PMAC ID. Must be unique. 5. Enter Channel Information And Test Input ( Channels Tab ) For each channel, select the channel and press Edit Channel. The program will remind you to update the logger when done. 1) Enter a Channel Name to identify the Cello inputs. 2) Enter Scale Factor + space + Units. The Scale Factor is the volume per pulse (if pulse input) or per least significant register wheel digit (if encoder input). Make sure there is a space between the scale factor and unit of measure. 3) If necessary, change the logging Interval ( Rate ) for each channel. For USA encoder/ pulse loggers, rates must be same as timebase. ( Rate = logging interval or Debounce period. Timebase = lowest common denominator of all Rates.) 4) To test the channel input, press Live Input.

F. S. Brainard & Co.: Cello Setup with WinGPS 3 5) Zero the pressure value if necessary: (a) Confirm Cello is not logging; (b) Remove any plastic protective sheath over pressure connector; (c) Disconnect from any line pressure; (d) Press Edit Value and enter 0. 6) If using alarms, enable Threshold and set as desired. 6. Enter Dialout Settings ( Remote Comms Tab) 1) Click "Operate modem every to enable dialout. 2) Set time to send data. 3) Select frequency. Usually this is every day in the early morning. (In rare cases of dialing out more than once per day, select Send data sub-daily every and sync to regular dialout time.) 4) If encoder, click Send index (this is the register reading). 5) Enter dialout number after General SMS to. Ignore other Dialout numbers. DIAL-OUT NUMBER: General SMS to: is the dial-out number. The Meter-Master web service phone number for all AT&T SIM cards is the four-digit short-code: 7413 (without quotes). If you have your own base station, use the phone number of SIM card in your host computer s modem. 7. Start Logging ( General Tab) Start logging also causes Cello to send out setup info. RS232 connection is briefly cut off. 1) Press Start Logging. 2) You can monitor the connection to the cellular network if desired to confirm that the Cello is connecting to the cellular network and sending data.

F. S. Brainard & Co.: Cello Setup with WinGPS 4 Signal Strength and SIM Card Tests OTHER TASKS Check connection to network, signal strength, and SIM registration. 1) If currently communicating with the Cello (the green connection banner shows at the bottom of the window), click the banner to disconnect. 2) In the menubar, go to: Tools Terminal. 3) Right-click anywhere on the screen and select Wake GSM Modem (or press Shift-F1). 4) See if registers on network. Should connect in <50 seconds. 5) Check if Message Reserve and Update show unlimited. If not, register the SIM card (see #1 above). 6) The signal strength of various wireless towers displays in columns. With Cello in its final location (i.e., vault closed), a signal strength over 14 is fine; one below 10 is inadequate. Between 10 and 14, the Cello may work fine, intermittently, or not at all depending on variations in tower signal and other factors. Enclosing in a vault can subtract from 10 to 20 off signal strengths. 7) To exit: Press F9. You may have to wait one or two minutes before the process shuts down and you are able to connect to the Cello again. View Cello Log (for troubleshooting) In the WinGPS menubar, select: Logger GSM View Error Log. (See Cello Installation and Troubleshooting instructions for common error messages.) Send Setup Info And Monitor Outgoing Data (for troubleshooting) Starting the logger or changing the site information causes the Cello to send its settings to the base station. When the logger is started with WinGPS, the terminal screen automatically comes up showing the communication over the cellular network. To make the Cello send setup info without stopping the recording in WinGPS: 1) Change any site setting (e.g., site name), then change it back. 2) Click Save Changes to write the setup info to the Cello. This will prompt the Cello to send out the setup information. 3) Click the green connection banner at the bottom of the screen to disconnect communication with the logger. 4) In the menubar, go to: Tools Terminal. 5) Right-click anywhere on the screen and select Rate 9600 bps (or press F5). 6) Within a couple of minutes, the logger will connect to the network and send out its settings. When sending settings and looking at exact communication ( Monitor option), you should first see a lot of Errors, then a number of blocks of data of 90-160 characters in length, then a sign off. If a block of data does not transmit properly, there will be an error message followed immediately by one retry. If that fails, the Cello will end the transmission and try again two minutes later, then one last time two minutes after that. If all three efforts fail, it will wait until the next scheduled transmission before trying again. Manually Upload Recent Data You can cause the Cello to send its most recent data to the host computer. In the WinGPS menubar, select: Logger "GSM" "Send Latest Data." Download ( Read ) Data In the WinGPS menubar, select: Logger Read Data. View Modem and SIM Info (e.g., modem IMEI and serial numbers) Same as Signal Strength and SIM Card Tests above: Tools Terminal Wake GSM Modem.

F. S. Brainard & Co.: Cello Setup with WinGPS 5 IMAGES General Tab & Menubar (items 2, 3, 4, 7) Channels Tab (item 5) Remote Comms Tab (item 6)