LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

Similar documents
TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

ST350 Radiation Counter

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit

GBA 327: Module 7D AVP Transcript Title: The Monte Carlo Simulation Using Risk Solver. Title Slide

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

E X P E R I M E N T 1

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

NENS 230 Assignment #2 Data Import, Manipulation, and Basic Plotting

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

PQ-Box 100 Quick Start Instructions

Activity P27: Speed of Sound in Air (Sound Sensor)

HBI Database. Version 2 (User Manual)

GETTING STARTED... 2 ENVIRONMENT SCAN... 2

PulseCounter Neutron & Gamma Spectrometry Software Manual

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

Data Acquisition Using LabVIEW

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

DE2-115/FGPA README. 1. Running the DE2-115 for basic operation. 2. The code/project files. Project Files

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Operating Instructions

User Guide & Reference Manual

The DataView PowerPad III Control Panel

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

Measurement User Guide

PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

Alternative: purchase a laptop 3) The design of the case does not allow for maximum airflow. Alternative: purchase a cooling pad

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Lab 1 Introduction to the Software Development Environment and Signal Sampling

Lab experience 1: Introduction to LabView

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

Guide to the FACS Calibur

Auxiliary states devices

1.1 Cable Schedule Table

Lab Determining the Screen Resolution of a Computer

System Requirements SA0314 Spectrum analyzer:

Getting started with Spike Recorder on PC/Mac/Linux

PYROPTIX TM IMAGE PROCESSING SOFTWARE

Analyzing and Saving a Signal

Transmitter Interface Program

LMH0340/LMH0341 SerDes EVK User Guide

Calibrating the timecode signal input

Data Loggers SL699, 703, 704 & 705. Impact Test Equipment Ltd & User Guide. User Guide

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 2nd Edition

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone

AMTR Report For Destiny Users

User Manual for Riverwatcher PC Program

Rack-Mount Receiver Analyzer 101

Transient Stability Events & Actions

Neutron Spectrometer Operation Manual

TracQ Basic. Spectroscopy Software v6.5. User's Manual

AP Statistics Sampling. Sampling Exercise (adapted from a document from the NCSSM Leadership Institute, July 2000).

HV/PHA Adjustment (PB) Part

Quick Reference Manual

HD-SDI Express User Training. J.Egri 4/09 1

Instructions for DataMark PDF Temperature Logger

CAEN Tools for Discovery

Syntor X Flash Memory Module Revision C

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Processor time 9 Used memory 9. Lost video frames 11 Storage buffer 11 Received rate 11

Source/Receiver (SR) Setup

802DN Series A DeviceNet Limit Switch Parameter List

Technical Specifications

SigPlay User s Guide

Activity P32: Variation of Light Intensity (Light Sensor)

Pre-processing of revolution speed data in ArtemiS SUITE 1

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

Chapter 6. Normal Distributions

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

SC24 Magnetic Field Cancelling System

potentiostat/galvanostat

Night Hawk Firing System User s Manual

Time Domain Simulations

Grid Interactive Advanced Features Self-Supply Mode

Definitive Guide to mod Bicron Surveyor 2000

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Setup Utility Guide. SF-16M 16-Channel Digital Matrix Amplifier

Lesson 1 EMG 1 Electromyography: Motor Unit Recruitment

Tektronix RSA306 USB Spectrum Analyzer

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

Processes for the Intersection

TracQ Basic. Spectroscopy Software v6.6. User's Manual

EAN-Performance and Latency

SC24 Magnetic Field Cancelling System

Exercise 5. Troubleshooting a QAM/DQAM Modem EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Signal flow tracing

OptoFidelity Video Multimeter User Manual Version 2017Q1.0

LabView Exercises: Part II

LOST COMMUNICATIONS - SOFTWARE/FIRMWARE CRASHING OR LOCKUP

WCS-D800 Programming Software for the Icom ID-800

USER GUIDE. Table of Contents

CyAn User Manual. Flow & Mass Cytometry Center Biomedical Core facility. Technion Faculty of Medicine

Tutorial 3 Normalize step-cycles, average waveform amplitude and the Layout program

SNG-2150C User s Guide

KF200 PORTABLE MANUAL

LOOK AT THE NETWORK OF METAL STRIPS ON THE BACKSIDE OF THE PROTOTYPING BOARD

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

SZU OPERATING INSTRUCTIONS SAT NAVI

Transcription:

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution This lab will have two sections, A and B. Students are supposed to write separate lab reports on section A and B, and submit the report at the beginning of the next lab to your lab T.A. A. Plotting a GM Plateau Objective: In this experiment, you will determine the plateau and optimal operating voltage of a Geiger- Muller counter. [All the GM counters do not operate in the exact same way because of differences in their construction. Hence, each GM has a different high voltage that must be applied to obtain optimal performance from the instrument. Hence, stay on the same table the whole semester for all other labs, as the data/information we obtain in this lab will be used in other labs as well. Also note the GM tube number that is used in your table for future reference.] Equipment: Set up ST- 360 counter with GM Tube and stand (er box, power supply transformer, GM tube, shelf stand, serial cable, and a source holder for the Stand) as shown in figure 1. Radioactive source: (e.g. Cs- 137, Sr- 90, or Co- 60). Procedure: 1. (Should have already been done for this lab, but if not.) Plug in the transformer/power supply into any normal electricity outlet and into the back of the ST- 360 box. Place the GM Tube in to the top of the shelf stand with the window down and the BNC connector facing upward. Connect the BNC cable from the GM to the ST- 360 and a serial port on the back of your PC. 2. Turn the ST- 360 power switch on. Turn on the computer ON and double click on ST360, program located in the desktop. You should see a blue control panel appear in the screen. Put the radioactive source on the source holder of the shelf stand. Keep the source stand on the second level from top of the shelf. 3. Go to Setup menu and select the HV setting option. In the Set High Voltage window, start with 700 Volts. Similarly in the Setup, set Step Voltage to 20, and select ON. In the Preset menu, select Time and enter 30 for number of

seconds and press OK. Also in the Preset menu, choose Number of Runs, and set it to 26. 4. You should see a large screen with a large window for the number of counts and data for all the runs on the left half of the screen. On the right half, you should see a window for the preset time, elapsed time, runs remaining, and HV and step voltages. If not, go to the view option and select counts. 5. Make sure there are no previous data by choosing the erase button (last one on the right). Then select the green diamond to start taking data. 6. When all the runs are taken, choose the File menu and Save as. (Create a group folder in the desktop, so that you can locate this file later). Then you may save the data file. The output file is a text file that is tab delimited, which means that it will load into most spreadsheet programs. Also, record your data in the Data Sheet I included in this manual. Figure 1: GM tube setup using a ST- 360 er Data Analysis: Use the graph paper to plot the graph (There is a graph page on this manual). Please label the graph properly with Voltage on X- and counts on Y- axis. Remember that colleting the data is a group work, whereas everyone should be plotting the graph for final submission to your T.A. during your final lab report.

DATA SHEET I Name: Date: 1000- ID: Table No: Data Table for GM Plateau Lab: Tube #: Voltage s Voltage s

B. Statistics Objective: To learn how to apply Poisson and Gaussian distribution methods to statistical data using Excel Background counts: The Geiger- Müller tube is susceptible to natural background radiation as well as to the radiation emitted from the source and cannot differentiate between the two. For any meaningful data to be taken and analyzed, the background radiation should be known and taken into consideration. Statistics of ing: Any radioactive disintegration is a spontaneous phenomenon, and hence is completely random as well as unpredictable. Hence in counting experiments, it is quite natural that the counts will vary for the same interval of time. Once cannot afford to predict any results based on such fluctuating data. At the same time we cannot ignore this data as completely deceptive because it will contain valuable information. Statistical analysis is the solution in analyzing this data to obtain overall sense of data to make predictions over measurements. In this section, you will be going to use Poisson distribution and Gaussian or Normal Distribution to study the radioactivity phenomena. The Poisson distribution is a probability distribution over a fixed interval of time using a single parameter, this parameter being the known expected value, usually the mean value of any specific occurrence within a fixed time frame. The number of nuclear disintegrations detected by a Geiger counter can be appropriately modeled using this method. The Poisson probability of event value of x to occur during the same time frame as the mean value! is determined using!! =!!!!! where! is the mean value of the occurrence during a fixed time frame and x is the value of which you desire to know the probability for its occurrence.!! For large values of! the Poisson distribution can become difficult to use as the x! value and! x value becomes unmanageable for programs such as Excel to use.

You should be familiar with the Normal or Gaussian distribution and its characteristic bell curve. The Gaussian distribution is given by!! = 1! 2!!"#!!! 2!! From this equation, the mean and standard deviation equations in which you are familiar are derived. Procedure 1. From the previous experiment you have determined an optimal operating voltage for the GM tube. This voltage will be used during the duration of the experiment. Setup the counter for the following. HV determined from your last experiment Preset Time 10s Runs 120 Step voltage 0 volts or disabled 2.Run a data set with no source under or near the Geiger- Müller tube. This will be your background count. Try to move the source as far away possible from the GM tube to getter better background reading. 3. Gather a set of data using each source Cs- 137 and/or Co- 60. Save your data for each source in the computer. Record this data in the data sheet below. 4. Take the data back home for further analysis and fitting. Process to fit the distribution in excel is given at the end of this lab manual.

Runs Name: 1000- ID: Source: Background Source Runs Background Source Runs Background Source 1 41 81 2 42 82 3 43 83 4 44 84 5 45 85 6 46 86 7 47 87 8 48 88 9 49 89 10 50 90 11 51 91 12 52 92 13 53 93 14 54 94 15 55 95 16 56 96 17 57 97 18 58 98 19 59 99 20 60 100 21 61 101 22 62 102 23 63 103 24 64 104 25 65 105 26 66 106 27 67 107 28 68 108 29 69 109 30 70 110 31 71 111 32 72 112 33 73 113 34 74 114 35 75 115 36 76 116 37 77 117 38 78 118 39 79 119 40 80 120

Name: 1000- ID: Source: Runs Background Source Runs Background Source Runs Background 1 41 81 2 42 82 3 43 83 4 44 84 5 45 85 6 46 86 7 47 87 8 48 88 9 49 89 10 50 90 11 51 91 12 52 92 13 53 93 14 54 94 15 55 95 16 56 96 17 57 97 18 58 98 19 59 99 20 60 100 21 61 101 22 62 102 23 63 103 24 64 104 25 65 105 26 66 106 27 67 107 28 68 108 29 69 109 30 70 110 31 71 111 32 72 112 33 73 113 34 74 114 35 75 115 36 76 116 37 77 117 38 78 118 39 79 119 40 80 120 Source

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Tips for fitting the Poisson and Normal distribution in Excel: (To be done back home) 4. Using MS excel or some equivalent type of program enter your data for the counts into a column. In another column subtract the average background counts from the collected counts for each run. 5. Into another column divide the corrected count data by the duration, in seconds, of the trial you now have a cps series of data. 5. Create within the spreadsheet cells for Average, Minimum, Maximum and Standard deviation in the adjacent cell enter in the appropriate function to perform the calculation. 6. Create columns headings for N, frequency, Poisson and Gaussian. 7. Under the N heading create bins 1 count apart from the minimum to the maximum value. Under frequency us e Excel s Frequency function. First select the area to be filled, this area should be the same number of rows as the N data column. Next select Insert function and select Frequency. A window will appear where you can enter the appropriate information. Data array is where the corrected data is stored, for example d:11:d131. The bin array is from the column label N. WAIT, do not simple select enter this will only fill one cell. The trick in filling the frequency column is to press and hold CTRL- SHIFT then select OK. N frequency Poisson Gaussian Average 390.81 374 1 Minimum 374 375 0 maximum 406 376 0 StdDev 6.23 377 0 378 0 379 1 389 6 390 10 391 4 402 2 403 5 404 6 405 2 406 0 7. The Poisson and Gaussian calculations can be computed by hand but more efficiently by using the built in functions that Excel provides. Again help for each function can be found within the excel program. Each of these functions has a

logical argument which needs to be set as FALSE, to provide the necessary numerical data. The value should also be multiplied by the number of trials used to better correspond to the frequency values when you graph the data. 8. Graph a Frequency vs. s graph also include the Poisson and Gaussian distribution fits on the same graph page. Make a separate graph for each source. An example is shown below. 12 10 Cs137 8 6 4 2 Frequency Poisson Gaussian 0 370 380 390 400 410-2