File E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:

Similar documents
File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT

KRF EMC Filters Installation, Operation and Maintenance Manual

Filters for Power Lines (Low Leakage Current)

Surge Protective Device

Three Phase - General Purpose. THREE PHASE: 3 kva - 9 kva Epoxy Encapsulated Series 76 ISO-Shield

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

SPECIFIC TECHNICAL CRITERIA

LED Driver Compact fixed output

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Circuit-Breakers for Motor Protection Series 8523/8

Air Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed

CAMTO LTD. Arc detecting system DC/AC

Figure 1: Device components

TOSHIBA Industrial Magnetron E3328

File E Project 01NK7526. April 4, 2001 REPORT TELEMETERING EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS. Metrix Instrument Co.

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LED Driver Linear / area fixed output

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

EMC Solutions Noise filtering

4 Wiring Brochure Wiring and installation of specific control

02/11/2015

Gear Pump Units For single-line centralized lubrication systems

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

Indoor Linear 80W Driver SI-C215280N2KR

TRISHALA ELECTROLYTICS PVT LTD BANGALORE

S192PGC-G5-1AG 1.6x0.8mm, Pure Green LED Surface Mount Chip LED Indicator Technical Data Sheet

Model Number Structure

Capacitance Limit Detection nivotester FTC 420/421/422

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Build A Video Switcher

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

VAT 20 Adjustable Frequency Drive

Electronic Timer Control Day Astronomic Electronic Control

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

LED control gear Compact fixed output

IK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request

Type: DILM25 10(24V50HZ) Article No.:

LED MODULES READYLINE DL

LED Driver Compact fixed output

EMC filters. 4-line filters for installations and systems Rated current 6 to 125 A. Date: January 2006

Gear Pump Units. For single-line lubrication systems

Electro Magnetic Compatibility (EMC) Warning. Important notes for users in the U.K. FCC declaration. Caution. Fuse

AF-300 E11 Adjustable Frequency Drive

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Modular Lube Lubrication Systems System Controls

C E R T I F I C A T E O F C O M P L I A N C E

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Type: DILM12 10(24VDC) Article No.:

LED Driver Compact fixed output

3 line filters for converters and power electronics

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

PAM-1840 Preamplifier Operation Manual

EA350. Generator Automatic Voltage Regulator Operation Manual

An Urgent Bulletin from CSA Group

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Modular Power System acc. VG MoFess Module for Military Ground Vehicles

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

GENESIS Indoor Air Conditioners

MIKRO POWER FACTOR CORRECTION COMPONENTS

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Spec No.: R3528 Date: 28-Sep-2017

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

G1-M1 (Protection Relay)

Working Document. Chapter 1. Subject matter and scope This Regulation establishes ecodesign requirements for simple set-top boxes.

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Emergency lighting units EM INVERTER

Installation Guide. Cellular Plug-in for Inverters with SetApp. Version 1.1

Monochrome Video Monitors

LED Driver Compact dimming

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

Solenoid Valves. Inline Valves IV. Nominal diameter 3 mm. Suitability for Industry-Specific Applications Schmalz - Applications.

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

Synchro System PHOTO NOT AVAILABLE. Description. Applications. Features

GENESIS Indoor Air Conditioners

Operating Instructions Dimmer for V Incandescent Lamps

LITE-ON TECHNOLOGY CORPORATION

MULTIS L72. Operating instructions

Self--powered Time Counter

Datasheet - SRB301LC 24VAC/DC

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

llen-bradley 194R-HM4-NFPA3

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

CHAPTER 3 SEPARATION OF CONDUCTED EMI

Dry Type Transformers. Section 10. BuyLog Catalog 10-1

M BTU/Hr Watts. Finish. Options

MAP110 AC-DC Series Data Sheet

SERIES 400 SERIES 620

Series Digital Dimmer. User Manual (VER: 2.0) Net.DO LIGHTING CONTROL EQUIPMENT CO.,LTD

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

POWER FACTOR CORRECTION

Transcription:

File E64388 Vol. 1 Sec. 106 Page 1 Issued: 1993-11-08 and Report Revised: 2011-06-01 DESCRIPTION PRODUCT COVERED: USR; Component - Appliance Filter, Models FN261#W-Y-XX-ZZ, FN9260#W-Y-XX- ZZ, FN9263#W-Y-XX-ZZ, FN9264#W-Y-XX-ZZ, FS6712#W-Y-XX-ZZ, FS6024-3-07, FS4588-3-07, FS23633-3-06, and FS 5897-6-07-1 where W can be nothing or the letters A, A1, B, C, C1, C2 or R, where # can be nothing or an S or S1, where y can be the number 1, 2, 3, 4, 6, 8 or 10, where XX can be the number 01, 05 or 06, where ZZ can be nothing or the numbers 05-40. USR, CNR Recognized Component - Appliance Filter, Model FS24814-3-07. ENGINEERING CONSIDERATION: The components covered by this report are electromagnetic interference filter assemblies intended to be used in electronic data processing equipment and similar equipment where the acceptability of the combination has been determined by Underwriters Laboratories Inc. ELECTRICAL RATINGS: All filters are rated V ac, 50/60 Hz. See Ill. 1 for voltage and current rating and Ill. 2 for circuit diagrams and dimensions. Type FN 261(S x)- 1-yy (-zz) FN9260(S x)- 1-yy (-zz) FN9263(S x)- 1-yy (-zz) FN9264(S x)- 1-yy (-zz) FS6712(S x)- 1-yy (-zz) FN 261(S x)- 2-yy (-zz) FN9260(S x)- 2-yy (-zz) FN9263(S x)- 2-yy (-zz) FN9264(S x)- 2-yy (-zz) FS6712(S x)- 2-yy (-zz) FN9263(S x)- 3-yy (-zz) FN9264(S x)- 3-yy (-zz) FS 6024-3-07 FS 4588-3-07 FS24814-3-07 Current (A) 1 2 3 Voltage (V ac) Frequency (Hz) Ambient ( C) FS23633-3-06 3 FN9263(S x)- 4-yy (-zz) FN9264(S x)- 4-yy (-zz) 4 FN 261(S x)- 4-yy (-zz) FN9260(S x)- 4-yy (-zz) FN9263(S x)- 4-yy (-zz) FN9264(S x)- 4-yy (-zz) FS6712(S x)- 4-yy (-zz) 5

File E64388 Vol. 1 Sec. 106 Page 1A Issued: 1993-11-08 and Report Revised: 2011-06-01 FN 261(S x)- 6-yy (-zz) FN9260(S x)- 6-yy (-zz) FN9263(S x)- 6-yy (-zz) 6 FN9264(S x)- 6 -yy (-zz) FS6712(S x)- 6-yy (-zz) FS 5897-6-07-1 FN9263(S x)- 8-yy (-zz) FN9264(S x)- 8-yy (-zz) 8 FN 261(S x)-10-yy (-zz) FN9260(S x)-10-yy (-zz) 10 FS6712(S x)-10-yy (-zz) FN9263(S x)-10-yy (-zz) FN9264(S x)- 10-yy (-zz) 10 Note: All filters may be marked 120/250V in lieu of V. USR indicates the filters have been evaluated to the Standard for Electromagnetic Interference Filters, UL 1283, Fifth Edition, Revision Date November 30,2005. CNR indicates the filters have been evaluated to the Standard for Electromagnetic Interference (EMI) filters, CSA C22.2 No. 8 M1986.

File E64388 Vol. 1 Sec. 106 *Page 2 Issued: 11-8-93 and Report Revised: 8-19-98 R E P L A C E M E N T P A G E The above referenced page has been deleted.

File E64388 Vol. 1 Sec. 106 Page 3 Issued: 1993-11-08 and Report Revised: 2008-10-15 CONDITIONS OF ACCEPTABILITIES (NOT FOR UL REPRESENTATIVE USE): General - For use only in complete equipment with the acceptability of the combination has been determined by Underwriters Laboratories Inc. The following items should be evaluated to determine the acceptability of the component in the end product. 1. The filter shall be installed within an overall enclosure suitable for the end product application. 2. Leakage current measurements have been provided for reference only. The need to determine leakage current in the end application shall be considered. 3. Capacitor Discharge voltage measurements have been provided for reference only. The need to determine capacitor discharge voltages in the end application shall be considered. 4. These components have been judged on the basis of the required spacings in the Standard of ELECTROMAGNETIC INTERFERENCE FILTERS, Paragraph 22.2. Spacings between terminals and dead metal products should comply with the end product requirements. 5. Case temperature should be monitored in the end product. 6. The terminals have not been evaluated as field wiring terminals. Acceptability of the grounding terminal connections should be determined in the end product. 7. The filters have been evaluated for use in systems rated for max. 60 Hz. 8. The filters have been evaluated for use in systems where the phase to neutral voltage does not exceed 250 V. 9. The acceptability of the means for overcurrent protection provided on the inlet receptacle shall be determined in the end-use application. 10. Abnormal operations test conducted as follows: Abnormal operation/limited short circuit rating: MODEL ABNORMAL TEST CURRENT (A) FN9263-1-06 200 FN9263S-6-06 1000 FN9263S1-8-06 2000 FS24814-3-07 1000

File E64388 Project 93ME37458 Issued: 1993-11-08 Revised: 2005-08-11 REPORT on RECOGNIZED COMPONENT ELECTROMAGNETIC INTERFERENCE FILTERS Applicant: Recognized Company: Schaffner EMV AG Luterbach, Switzerland Schaffner EMV AG Luterbach, Switzerland Copyright 1993 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above-named company to reproduce that portion of this Report consisting of this Cover Page through Page 3.