Three Phase - General Purpose. THREE PHASE: 3 kva - 9 kva Epoxy Encapsulated Series 76 ISO-Shield
|
|
- Phillip Flynn
- 5 years ago
- Views:
Transcription
1 26 THREE PHASE: 3-9 Epoxy Encapsulated Series 76 ISO-Shield Features UL Listed, File E3210. CSA Certified, File LR 560. Electrostatic shield between primary and secondary windings provides cleaner output voltage and helps to reduce spikes and transients. Epoxy-silica encapsulated core and coil provides a transformer particularly well suited for harsh commercial and industrial applications. Copper windings and copper lead wire terminations used throughout. UL Class 180 C insulation system with a 115 C temperature rise at a maximum ambient of 40 C. NEMA-3R, wall mount enclosure suitable for indoor or outdoor use. No extra rainshields required for outdoor use. THREE PHASE: Ventilated Series 63 ISO-Shield Features UL Listed, File E CSA Certified, File LR 560. Electrostatic shield between primary and secondary windings provides cleaner output voltage and helps to reduce spikes and transients. Aluminum windings connect to bus bar style terminations equipped with NEMA standard holes for compression style or ring terminals. UL Class 220 C insulation system with 150 C temperature rise at full load and a maximum ambient of 40 C. NEMA-3R, ventilated, cabinet style, floor mount enclosure suitable for indoor or outdoor use. No extra rainshields required for outdoor use. Vibration dampening pads provide quiet operation. Multiple knockouts provide convenient conduit entry and exit locations through the front and bottom access wiring compartment covers. Ground studs provided for bonding compatibility with both metallic and nonmetallic conduit. Nonstandard designs are available by consulting the factory or your Dongan representative Wall Mounting brackets are available in sizes up to 75. Ground studs provided for bonding compatibility with both metallic and nonmetallic conduit. Core and coil and nonstandard designs are available by consulting the factory or your Dongan representative.
2 THREE PHASE: 3-9 Ventilated Series 63 Scott ected Features UL Listed, File E3210. CSA Certified, File LR 560. Copper windings and copper lead wire terminations used throughout. UL Class 180 C insulation system with a 115 C temperature rise at a maximum ambient of 40 C. NEMA-3R, wall mount enclosure suitable for vertical mount in indoor or outdoor applications. No extra rainshields required for outdoor use. Multiple knockouts provide convenient conduit entry and exit locations through the side and back of the wiring compartment. Ground studs provided for bonding compatibility with both metallic and nonmetallic conduit. THREE PHASE: Series Optional Wall Mounting Brackets Three Phase Slim profile provides convenient mounting for space limited areas. Neutral (X0) provided on three phase, 4 wire transformers. Three Phase 75 No. BR No. BR
3 Primary Volts Delta, Secondary Volts Delta, 60 Hz May be used on a Y / 277 Volt Supply Lbs s Maximum Amps Pri. Sec. Height Width A B Pg. 32 Depth C SH SH SH SH SH SH SH SH SH SH *Transformers 15 through 150 are equipped with a 120 volt lighting tap. Lighting tap capacity is limited to 5% of nameplate rating distributed equally on either side of XO. Primary Volts Delta, Secondary Volts, 60 Hz May be used on a Y / 277 Volt Supply Lbs s Maximum Amps Pri. Sec. Height Width A B Pg. 32 Depth C SH SH SH SH SH SH SH SH SH SH ection Diagrams may be found on Pg. 32 Configurations: 0 = No s 2 = 1-5% FCAN, 1-5% FCBN 4 = 2-2½% FCAN, 2-2½% FCBN 6 = 2-2½% FCAN, 4-2½% FCBN Dimensions & weights may change. Consult factory for certified drawings. Drawing 1 Wall Mount - Encapsulated - NEMA 3R Drawing Floor Mount - Ventilated - NEMA 3R 28
4 Primary 600 Delta, Secondary Delta, 60 Hz Lbs s Maximum Amps Height Width Depth A B C Pri. Sec. Pg SH SH SH SH SH SH SH SH SH SH Primary 600 Delta, Secondary, 60 Hz Lbs s Maximum Amps Pri. Sec. Primary Delta, Secondary, 60 Hz Height Width A B Pg. 33 Depth C SH SH SH SH SH SH SH SH SH SH Lbs s Maximum Amps Pri. Sec. Height Width A B Pg. 33 Depth C SH SH SH SH SH SH SH *Transformers 15 through 150 are equipped with a 120 volt lighting tap. Lighting tap capacity is limited to 5% of nameplate rating distributed equally on either side of XO. No. ection Diagrams may be found on Pg. 33 Configurations: 0 = No s 2 = 1-5% FCAN, 1-5% FCBN 4 = 2-2½% FCAN, 2-2½% FCBN 6 = 2-2½% FCAN, 4-2½% FCBN Dimensions & weights may change. Consult factory for certified drawings. Drawing 1 Wall Mount - Encapsulated - NEMA 3R Drawing Floor Mount - Ventilated - NEMA 3R 29
5 VENTILATED SCOTT CONNECTED Primary Volts Delta, Secondary Volts Delta, 60 Hz May be used on a Y / 277 Volt Supply Lbs s Maximum Amps Height Width Depth A B C Pri. Sec. Pg. 32 * Primary Volts Delta, Secondary Volts, 60 Hz May be used on a Y / 277 Volt Supply Lbs s Maximum Amps Height Width Depth A B C Pri. Sec. Pg Drawing 1 Wall Mount - Encapsulated - NEMA 3R Drawing Floor Mount - Ventilated - NEMA 3R ection Diagrams may be found on Pg. 32 Configurations: 0 = No s 2 = 1-5% FCAN, 1-5% FCBN 4 = 2-2½% FCAN, 2-2½% FCBN 6 = 2-2½% FCAN, 4-2½% FCBN Dimensions & weights may change. Consult factory for certified drawings. Drawing 3, Scott ected Wall Mount - Ventilated - NEMA 3R 30
6 ADDITIONAL VOLTAGE COMBINATIONS AVAILABLE Prefix 63 = UL Listed File E78234, CSA Certified LR 560 Prefix 76 = UL Listed File E3210, CSA Certified File LR 560 General Information Pri Sec. 208Y/120 Y/ Y/ Y/127 Hz /60* 50/60* 50/60* 50/60* General Information Pri Sec. 208Y/120 Y/ Y/220 Y/ Y/347 Hz. 50/60* 50/60* /60* SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH SH (lbs) 60 Hz. (lbs) 60 Hz. *50/60 Hz. units are approximately 20% heavier than 60 Hz. unit weights shown. ection Diagrams furnished upon request. Please consult the factory or your Dongan Representative for price, delivery and dimensions. Dongan specializes in rapid delivery of nonstandard, voltage and tap configurations. Send us your request today for a competitive quote on transformers not specifically listed in this catalog. Most special designs are UL listed and CSA certified at no additional cost. 31
7 Three Phase ection Diagrams 1 High Series 63-02XX No s ect ect High Lines To 100 Low ect ect Low Lines To 100 X1 & X2 & X3 4 High Series 63-03XX No s ect ect High Lines To 100 Low ect ect Low Lines To 2 5 High Series 76-03XXSH No s ect ect High Lines To 100 High Low Series 76-02XXSH No s ect ect ect High Lines To 100 Low ect ect Low Lines To 100 X1 & X2 & X3 ect Low Lines To 3 Series 63-62XXSH High ect to to to to to to to 6 Low ect ect High Lines To ect Low Lines To 100 X1 & X2 & X3 * X2, X0 or X3, X0 *Lighting tap capacity is limited to 5% of nameplate rating distributed equally on either side of X0. 6 Series 63-63XXSH High ect to to to to to to to 6 Low ect ect High Lines To ect Low Lines To 32
8 Three Phase ection Diagrams 7 High Series 76-06XXSH No s ect ect High Lines To 100 Low ect ect Low Lines To 10 Series 63-61XXXSH High 600 ect to to to to to to to 6 Low ect ect High Lines To ect Low Lines To 100 X1 & X2 & X3 * X2, X0 or X3, X0 8 Series 63-66XXSH High ect to to to to to to to 6 Low ect ect High Lines To ect Low Lines To 11 High 600 Series XSH No s ect ect High Lines To Low ect ect Low Lines To 9 High 600 Series 76-01XXXSH No s ect ect High Lines To Low ect ect Low Lines To 100 X1 & X2 & X3 12 Series 63-60XXSH High 600 ect to to to to to to to 6 Low ect ect High Lines To ect Low Lines To *Lighting tap capacity is limited to 5% of nameplate rating distributed equally on either side of X0. 33
ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS
SECTION ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS 600 Volt Class, Encapsulated Single Phase and Three Phase Description and Applications... 8 Copper NEMA R Features... 8 Copper Single Phase Selection
More informationEncapsulated Distribution
Encapsulated Distribution Transformers Commercial & Industrial Single Phase and Three Phase HPS Fortress Commercial Encapsulated Transformers Applications & Features... 224 Single Phase Standard Specification...
More informationDry Type Transformers. Section 10. BuyLog Catalog 10-1
For more information on these products, order publications listed in Section 27. Find What You Need Faster - Page headings and table format make product selection easier. Easy Cross Reference - Frame size
More informationVentilated Distribution Transformers 6
Ventilated Distribution Transformers 6 General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 through 500. Indoor and outdoor models available.
More informationDry Type Transformers Section 10
For more information on these products, order publications listed in Section 27. Find What You Need Faster - Page headings and table format make product selection easier. Easy Cross Reference - Frame size
More informationGENESIS Indoor Air Conditioners
Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 68 68 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners
More informationM BTU/Hr Watts. Finish. Options
Spec-00607 CPH FX ( Protective Cooling Air Conditioners Indoor Air Conditioners M13 1000 BTU/Hr. 293 Watt M17 1800 BTU/Hr. 527 Watt Industry Standards Maintains U/cUL Type 12 rating when properly installed
More informationSECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.
SECTION 33 71 49.23 MEDIUM VOLTAGE CABLE INSTALLATION PART 1 GENERAL 1.1 SCOPE A. Work included in this Section: Medium Voltage Cable (4 kv and 12 kv) Installation and Termination. Removal and return of
More information120 V~ Feed-Through DIN Panels (and Accessories)
The Lutron family of DIN rail panels are designed to accept Lutron DIN power modules (DPMs). The compatible DPMs can be configured in the panel to control multiple load types to fit the size, lighting
More informationFeatures. Specifications. Finish. Notes
Spec-00732 BPH FX ( McLean Electronics Cooling Sealed Enclosure Cooling McLean Electronics Cooling: Sealed Enclosure Cooling SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt N36 / BTU/Hr.
More informationGENESIS Indoor Air Conditioners
PH FX ( Product Overview : Indoor Air Conditioners M28 Model M52 460 Volt 3-Phase Model M17 Model 74 74 Product Overview : The specifier s choice for cooling industrial process controls Indoor Air Conditioners
More informationPower Transformers & High Frequency Magnetics Your one source for all your magnetics needs!
www.signaltransformer.com Power Transformers & High Frequency Magnetics Your one source for all your magnetics needs! Audio Battery Chargers Communication Dental Equipment Elevator Controls Fire & Safety
More informationT-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C
: Product Overview Keeps its cool during peak heat loads and hot weather A/C Indoor/Outdoor Air Conditioners Chapter Contents PRODUCT OVERVIEW T15 Model 800 BTU...43 Indoor/Outdoor Air Conditioners...42
More informationPCR AUTOMATIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationWLB SERIES HID Lighting for Hose Down Applications
WLB SERIES W LB HID Lighting for Hose Down Applications Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations NEMA 4X NSF Certified Food Equipment CUL Heavy Hose
More informationTX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)
CLIMAGUARD Air-to-Air Outdoor TX23 Models 14 W/ F (25 W/ C) TX33 Models 28 W/ F (50 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C) INDUSTRY STANDARDS ; Type 12, 4; 4X optional; File
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More informationXML LED X M L L E D. Explosionproof Linear LED Lighting
LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924
More informationN BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners
Spec-00732 F Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt INDUSTRY STANDARDS N36 / BTU/Hr. / Watt N28 BTU/Hr. Watt UL/cUL
More informationFile E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:
File E64388 Vol. 1 Sec. 106 Page 1 Issued: 1993-11-08 and Report Revised: 2011-06-01 DESCRIPTION PRODUCT COVERED: USR; Component - Appliance Filter, Models FN261#W-Y-XX-ZZ, FN9260#W-Y-XX- ZZ, FN9263#W-Y-XX-ZZ,
More informationIK10 IP68. Specifications. White (4 300 K typical) Warm white (3 000 K typical) Blue (470 nm) Other colors by request
1300 Industrial Road, Unit #19 San Carlos, CA 94070 FREE CALL 1-866-695-5862 US & Canada info@lumascape.com LS553LED Via Ingrade IP68 IK10 The LS553LED is a rugged, side emitting marker light constructed
More informationXR47-24 Models 24 W/ F (43 W/ C)
CLIMAGUARD AIR-TO-AIR INDOOR XR20 Models 4 W/ F (7 W/ C) XR29-08 Models 8 W/ F (14 W/ C) XR29-18 Models 18 W/ F (32 W/ C) XR47-24 Models 24 W/ F (43 W/ C) XR47-35 Models 35 W/ F (63 W/ C) XR60-55 XR60-84
More informationWCHE BTU/Hr Watts
763.576.3200 SPEC-00754 F763.422.2211 THERMAL MANAGEMENT SEALED ENCLOSURE COOLING HEAT EXCHANGERS Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD AIR-TO-WATER INDOOR WCHE01 2968 BTU/Hr. 870 Watts WCHE04/WCHE06
More informationXR47-24 Models 24 W/ F (43 W/ C)
763.576.3200 Spec-00620 F763.422.2211 Cooling Sealed Enclosure Cooling Heat Exchangers Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD Air-to-Air Indoor XR20 Models 4 W/ F (7 W/ C) XR29-08 Models 8
More informationN43 N36 N28. Sealed Enclosure Cooling Air Conditioners
SPECTRACOOL NARROW INDOOR/OUTDOOR N43 N36 N28 11000 BTU/Hr. / BTU/Hr. BTU/Hr. 3223 Watt / Watt Watt INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop
More informationXR47-24 Models 24 W/ F (43 W/ C)
Heat Exchangers CLIMAGUARD Air-to-Air Indoor XR20 Models 4 W/ F (7 W/ C) XR29-08 Models 8 W/ F (14 W/ C) XR29-18 Models 18 W/ F (2 W/ C) XR47-24 Models 24 W/ F (4 W/ C) XR47-5 Models 5 W/ F (6 W/ C) XR60-55
More informationEXLUX ECOLUX C-LUX 6480 Series
EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent
More informationModel Material Lamp type LED color Voltage Distribution Lens
4426 SERIES LED Wet Niche Swimming Pool DMX Color Changing CATALOG NUMBER NOTES TYPE Specifications L: 10-3/8 264 mm W: 11-1/4 286 mm H: 11-1/4 286 mm Weight lbs 11 1/4" (286) 8 7/8" (225) 1" (25) 1 3/8"
More informationWCHE BTU/Hr Watts
763.576.3200 SPEC-01037 A763.422.2211 COOLING SEALED ENCLOSURE COOLING HEAT EXCHANGERS Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD AIR-TO-WATER INDOOR HEAT EXCHANGERS WCHE01 2968 BTU/Hr. 870 Watts
More informationCR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.
763.576.3200 Spec-00614 I763.422.2211 Sealed Enclosure Cooling Air Conditioners Sealed Enclosure Cooling Air Conditioners PROAIR Harsh Environment CR23 1600 BTU/Hr. 469 Watt CR29 2700 and 4000 BTU/Hr.
More informationFile E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS
File E322469 Project 4786125262 December 11, 2013 REPORT On DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS Lutron Electronics Co Inc Coopersburg, Pa Copyright 2013 UL LLC UL LLC authorizes
More informationSurge Protective Device
Surge Protective Device Series RE - Residential TYPE Whole house surge protection Blue indicator LED 50 ka surge current strength Optional electrical noise filter Five year warranty Protect residence from
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationCast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)
30A 400A (30 200A Load Breaking), Maximum 600VAC/250VDC Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion-Proof Interlocked Receptacles Cast Aluminum Circuit Breaker Interlocked
More informationAdaptabel AC Single Stroke Bells
Adaptabel AC Single Stroke Bells PLC Compatible 332 Series > Completely assembled, all hardware supplied > Universal Adaptaplate mounts directly on surface or electrical box > Shockproof die cast housing
More informationSAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations
LED Class I, Division 2, Groups A, B, C, & D Class II, Divisions 1 & 2, Groups E, F & G Class III UL 1598A Marine Outside Type UL 1598 Wet Locations UL 844 Hazardous Locations UL 8750 LED Safety Tested
More informationWCHE BTU/Hr Watts
Spec-00754 B Sealed Enclosure Heat Exchangers Sealed Enclosure Heat Exchangers CLIMAGUARD Air-to-Water Indoor WCHE01 2968 BTU/Hr. 870 Watts WCHE04/WCHE06 7506/10577 BTU/Hr. 2200/3100 Watts WCHE14 22861
More information1 Power Protection and Conditioning
Power Protection and Conditioning MCR Hardwired Series Power Line Conditioning with Voltage Regulation The MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected
More informationSQM40/41 Actuators for air and gas dampers
SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The
More informationOWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel
OWNERS MANUAL Revision 1.8 09/01/2002 OWNERS MANUAL Page 2 of 12 AR-1202 UNIT DESCRIPTION The AR-1202 consists of a processor and 12 dimmer channels of 2.4KW each. Each dimmer channel is protected by a
More informationChamp-Pak Wall Pack Luminares
Restricted Breathing Cl. I, Div. 2 & Zone 2 ( S826) ( S826TB) Cl. III & Simultaneous Presence Marine & Wet Locations The first low-profile wall pack designed specifically for hazardous areas. The Eaton
More informationSign Illuminating Products. Plastic Sign Fluorescent Ballasts HID Sign Ballasts T5, T8, T12 Electronic Ballasts
Sign Illuminating Products Plastic Sign Fluorescent Ballasts HID Sign Ballasts T5, T8, T12 Electronic Ballasts The Sign Of A Leader Signa is the newest brand in sign solutions yet weʼre part of a company
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationHypnotica is Color Changing Series
PRODUCT SUMMARY PRODUCT FEATURES Slender, low profile Smooth, even light output Compatible with any 512 controller or any RDM (Remote Device Mangement) controller Controllable in 6 increments Applications:
More informationGOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET
PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination
More informationICS Digital Menu. Installation Guide Version 1.1
ICS Digital Menu Installation Guide Version 1.1 Installation Overview This document was written to assist technicians and electricians in installing the ICS Digital Menu. A thorough understanding of electrical
More informationSign Illuminating Ballasts
Sign Illuminating Ballasts A Complete Range Of Solutions From The Name You Trust Universal Lighting Technologies ( Universal ) is known throughout the sign business as a company that can set and meet today
More informationT BTU/Hr Watts. T BTU/Hr Watts. Finish. Accessories. Options
T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts Industry Standards UL/cUL Listed; Type 12, 3R,
More informationUltra Quiet Series Electric Air Handler
Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationEC7000, EC7004 and EC7005 Single Channel Electronic Time Controls
http://waterheatertimer.org/paragon-timers-and-manuals.html#ec Replacement timer http://waterheatertimer.org/intermatic-et-series-timers-and-manuals.html#et1700 EC7000, EC7004 and EC7005 Single Channel
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationlumenalpha spot Specification Sheet
Client Project name Order# Type Qty FEATURES AND BENEFITS Physical Housing material: extruded aluminum Available in or 8 sections Finish: black or white Ceiling mounting: surface or recessed Wall mounting:
More informationT BTU/Hr Watts
763.576.3200 Spec-00734 H763.422.2211 Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts
More informationMagnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A
72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature
More informationAriadni Dimmer For 250W CFL/Led, 600W Inc/Hal, or Lutron Hi-Lume A-Series Lte Led Driver, Clamshell Packaging In White
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AYCL253PHWH 1P 3WY 120V DMR Lutron Catalog Number Manufacturer Description Weight per unit Product Category Features actuator
More informationTRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES
1.0 SCOPE TABLE OF CONTENTS 2.0 CABLES SPLICES 2.1 Definitions 2.2 Scope of Specifications and Drawings 2.3 General Requirements 2.4 Routing Cables 2.5 Connectors 2.6 Conductor Connections 2.7 Heat Shrinkable
More informationT BTU/Hr Watts
T-SERIES Mid-size Outdoor T29 4000 BTU/Hr. 1173 Watts T43, 8000, 10000 BTU/Hr., 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts T53 19000 BTU/Hr. 5567 Watts INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R,
More informationSplit System Air Conditioner
Residential & Light Commercial HVAC Split System Air Conditioner 1 R-410A, 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons
More informationWFH SERIES Fluorescent High-Bay Lighting for Hazardous Locations
WFH SERIES W FH Fluorescent High-Bay Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C, & D Class II, Division 2, Groups F & G Class III UL Listed for Wet & Hazardous Locations CUL Listed
More informationInstallation and Operation Manual. YMP Series Signal Programmer
Installation and Operation Manual YMP Series Signal Programmer February 2006 YMP Series Clock/Signal Programmer Installation and Operation Manual YMP Series Clock/Signal Programmers YMP YMP02 YMP04 YMP06
More informationSystem Satellites Acoustimass Module. 2.5" (64 mm) full-range driver (per satellite) 5.25" (133 mm) dual voice coil low frequency driver
Key Features Subwoofer/satellite systems that deliver high fidelity and extendedbandwidth reproduction of voice and music for a wide range of installed applications, including retail, restaurant and hospitality
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2007-05-23 Page 1 of 3 Report Reference # E135803-A37-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power
More informationSINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS
SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical
More informationElectronic Timer Control Day Astronomic Electronic Control
Electronic Timer Control - 365-Day Astronomic Electronic Control Item ET90215CRE / EAN-Code PRODUCT DESCRIPTION The ET90000 Series combines powerful and intuitive scheduling with truly maintenance-free
More informationIP65. Specifications. White (4 300 K typical) Blue (470 nm) On-site or factory-programmable brightness. Black Silver Polished copper.
1300 Industrial Road, Unit #19 San Carlos, CA 94070 FREE CALL 1-866-695-5862 US & Canada info@lumascape.com Cassia Wallmount IP65 52 CUTOFF The is a compact, fixed position, direct/indirect accent used
More informationAYCL253PBR Ariadni 250W Led 3WAY Dimmer Brown
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AYCL253PBR Ariadni 250W Led 3WAY Brown Lutron Catalog Number Manufacturer Description Weight per unit Product Category
More informationFilters for Power Lines (Low Leakage Current)
Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures
More informationSmart-Encoder : Optical Incremental
1. Introduction The Smart-Encoder effectively eliminates multiple encoder part numbers by bringing intelligence and security to its design. In seconds, a four-digit LED display with two push-buttons enables
More informationTOKISTAR. TokiLux TOKISTAR LIGHTING
TOKISTAR TokiLux TOKISTAR LIGHTING TokiLux Systems T okilux is a compact high-performance LED luminaire for use as an indirect light source within tight architectural details and a variety of casework
More informationIndyGo Facility Upgrades Project 35671EE
SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for
More informationSCALE & WEIGHT DISPLAYS
The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters
More informationLARGE DIGITAL TEMPERATURE LED DISPLAYS
LARGE DIGITAL TEMPERATURE LED DISPLAYS THERMOCOUPLE & PT100 (RTD) INPUTS Alarms and Retransmission Output 0-10Vdc, 4-20mA, RS-232, RS-485, Modbus, ASCII INDOOR OR OUTDOOR USE 3, 4, 5, Digits with Decimal
More informationMHB BTU/Hr Watt
763.576.3200 Spec-00613 J763.422.2211 Sealed Enclosure Cooling Air Conditioners Sealed Enclosure Cooling Air Conditioners GENESIS Top-Mount Indoor HB16 8000 BTU/Hr. 2051 Watt MHB11 2200-4000 BTU/Hr. 645-1172
More informationAC1036. Definite Purpose Contactors
Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous
More informationType Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US
Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand meets FCC
More informationBE3-GPR GENERATOR PROTECTIVE RELAY
BE3-GPR GENERATOR PROTECTIVE RELAY Behind-the-Panel Mounting Semi-flush Mounting Basler Electric s BE3-GPR generator protective relay offers multiple protective features in a single package. Its microprocessor-based
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More informationMIKRO POWER FACTOR CORRECTION COMPONENTS
MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR REGULATOR Steps 6, 8, 12, 14 Voltage 1 4V AC Frequency 0 and 60 Hz Detection method Displacement Power Factor Input current A Modes Automatic,
More informationNessie Coils for VDH and VDHT valves
Data Sheet Nessie Coils for VDH and VDHT valves Introduction The coils for the Danfoss High-Pressure Systems valves are high-performance and reliable coils based on more than 50 years manufacturing of
More informationPower and Control T YPE BY RAVI GANATR November/December IAEI NEWS
Power and Control 26 1999 November/December IAEI NEWS T YPE BY RAVI GANATR This article discusses how the requirements in both the installation code and the product standard are utilized to manufacture
More informationModel Number Structure
Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control
More informationSeries CDP2 Definite Purpose Contactors
Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air
More informationCatalogue Ignitors and power switches for HID
Catalogue 2012 Ignitors and power switches for HID Overview Product overview Ignitor matrix Standards Page 6 Page 7 Page 8 Product information Ignitors and power switches for HID Page 9 Superimposed-pulse
More informationHarmonic correction unit (HCU2)
Technical Data TD156001EN Harmonic correction unit (HCU2) Harmonic correction units (HCU2) Contents Description Page Product description.... 2 Advantages.... 2 Features, benefits, and functions.... 2 Catalog
More informationChannel Cable Tray - Accessories
Splice Plate The Splice Plate has the standard 4-hole pattern for all cable channel. Provided with straight sections and fittings. 9(*)-1043 3 (76) 9(*)-1044 4 (101) 9(*)-1044-6 6 (152) Horizontal Adjustable
More informationLow Voltage Power Panel
GE EntellEon * Low Voltage Power Panel Ratings & Accessories These instructions do not cover all details or variations in equipment, nor do they provide for every possible contingency that may be met in
More informationLinatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance
The Linatron -M is a modular system. The control console, modulator, and RF unit are common to all model configurations. Only the X-ray head changes to match the application. The Linatron - M is designed
More informationAir Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed
Cooling Fans MU Series Slim-Line, General-Purpose s 4.69 in. 1.5 in. thick ( 119 mm 38 mm thick) Ambient Temperature: 14 F to 14 F ( 1 C to 6 C) Operating Voltage Range: 1% Materials Frame: Die Cast Aluminum
More information3 Cold Shrink Products
3 Cold Shrink Products Low Voltage Splices 0-600V (1000V rated) 279 Cold Shrink Splices (0-1000V) 279 Cold Splicing Products 279 Resin Splices 0-600V (1000V rated) 281 Resin 284 3M 8420 and 8430 Series
More informationTOKISTAR TOKISTAR LIGHTING
L i g hts tr ing s TOKISTAR TOKISTAR LIGHTING Lightstrings T okistar Lightstrings are a system of sockets wired in parallel and permanently attached to flexible, commercial-grade wire. All-weather construction
More informationMagnum Panel Systems. UL1741 Interconnection System Equipment. The Powerful Difference
Magnum Panel Systems UL1741 Interconnection System Equipment The Powerful Difference MMP Mini Magnum Panel The MMP Enclosure The MMP shown with inverter (sold separately) and optional remote and backplate.
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationNova T* Controls. Nova T*
Nova T* s This series of classic thin-profile linear-slide dimmers and switches offers the following standard features: Square Law Dimming Voltage compensation (not applicable to NTCL-250) Power-failure
More informationEXLUX ECOLUX 6480 Series
EXLUX ECOLUX 6480 Series L I G H T I N G 6000 6008 6400 6408 6600 6608 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent
More informationNW Neutral White 4000K, 70 min. CRI. 70LA LEDs, 350mA. 85LA LEDs, 350mA. CW Cool White 5700K, 70 min. CRI. 105LA LEDs, 530mA
Project: Site & Area Location: Cat.No: Type: Gullwing LED Qty: Notes: Small, GL13 Philips Gardco Gullwing LED GL13 area luminaires combine LED performance excellence and advanced Gardco LED thermal management
More informationBulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page
3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7
More information