FEL Gun Test Stand (GTS) from construction to beam operations

Similar documents
Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

The SLAC Polarized Electron Source *

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

VERY HIGH VOLTAGE PHOTOEMISSION ELECTRON GUNS*

Operation of CEBAF photoguns at average beam current > 1 ma

Design Studies For The LCLS 120 Hz RF Gun Injector

Cathode Studies at FLASH: CW and Pulsed QE measurements

Results of recent photocathode studies at FLASH. S. Lederer, S. Schreiber DESY. L. Monaco, D. Sertore, P. Michelato INFN Milano LASA

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

High QE Photocathodes lifetime and dark current investigation

SLAC R&D Program for a Polarized RF Gun

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

Photo cathode RF gun -

Summary of recent photocathode studies

Screen investigations for low energetic electron beams at PITZ

The temperature management of photo cathodes at MAMI and MESA

Capability Improvements: Polarized Photoinjector*

JLab 10kW FEL Driver Beam Diagnostics

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Photocathodes FLASH: Quantum Efficiency (QE)

Review of Diamond SR RF Operation and Upgrades

Photoinjector Laser Operation and Cathode Performance

Technology Challenges for SRF Guns as ERL Sources in View of Rossendorf work

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

Program Risks Risk Analysis Fallback Plans for the. John T. Seeman DOE PEP-II Operations Review April 26, 2006

The Use of an Electron Microchannel as a Self-Extracting and Focusing Plasma Cathode Electron Gun

AREAL- Phase 1. B. Grigoryan on behalf of AREAL team

DEVELOPMENT OF A 10 MW SHEET BEAM KLYSTRON FOR THE ILC*

EPJ Web of Conferences 95,

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

TEST RESULTS OF THE 84 GHZ / 200 KW / CW GYROTRON

PHIN. Report on the Development of a Radio-Frequency Photo Electron Source with Superconducting Niobium Cavity (SRF Gun Realization)

Development of Multiple Beam Guns for High Power RF Sources for Accelerators and Colliders

Spear3 RF System Sam Park 11/06/2003. Spear3 RF System. High Power Components Operation and Control. RF Requirement.

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

Beam Losses During LCLS Injector Phase-1 1 Operation

Approved by: / / R. Battaglia 12/16/2016

PEP II Design Outline

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

Performance of the MCP-PMT for the Belle II TOP counter

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

LCLS Injector Technical Review

These are used for producing a narrow and sharply focus beam of electrons.

Current status of XFEL/SPring-8 project and SCSS test accelerator

Etching Part 2. Saroj Kumar Patra. TFE4180 Semiconductor Manufacturing Technology. Norwegian University of Science and Technology ( NTNU )

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

RF Power Generation II

Mechanical aspects, FEA validation and geometry optimization

THE X-RAY ADVANTAGE Pros and cons X-ray and Gamma

INFN Milano LASA News on Cathode Development

!"!3

Linac 4 Instrumentation K.Hanke CERN

e-vap 3kW Evaporation Sources

Lecture 17 Microwave Tubes: Part I

Electromagnetic Block Valves Direct Acting

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

Status of RF Power and Acceleration of the MAX IV - LINAC

LITE-ON TECHNOLOGY CORPORATION

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

Status of BESSY II and berlinpro. Wolfgang Anders. Helmholtz-Zentrum Berlin for Materials and Energy (HZB) 20th ESLS-RF Meeting

DARK CURRENT IN SUPERCONDUCTING RF PHOTOINJECTORS MEASUREMENTS AND MITIGATION

Pseudospark-sourced Micro-sized Electron Beams for High Frequency klystron Applications

High Rep Rate Guns: FZD Superconducting RF Photogun

A Unique Power Supply for the PEP II Klystron at SLAC*

A New 4MW LHCD System for EAST

THE CARE AND FEEDING OF CROWBAR THYRATRONS

A quick and dirty magnet design for the magnetized beam LDRD proposal Jay Benesch 10/16/2015

SRF-gun Development Overview. J. Sekutowicz 17 th September, 2015 SRF15, Whistler, Canada

CATHODE-RAY OSCILLOSCOPE (CRO)

This work was supported by FINEP (Research and Projects Financing) under contract

Technology Challenges for SRF Guns as ERL Source in View of BNL Work

Hollow Cathode and Thruster Discharge Chamber Plasma Measurements Using High-Speed Scanning Probes

Correlation of Hollow Cathode Assembly and Plasma Contactor Data from Ground Testing and In-Space Operation on the International Space Station *

CHAPTER 9. Actives Devices: Diodes, Transistors,Tubes

Performance Characteristics of Steady-State MPD Thrusters with Permanent Magnets and Multi Hollow Cathodes for Manned Mars Exploration

Improvements in Gridless Ion Source Performance

Drift Tubes as Muon Detectors for ILC

Light Emitting Diodes

Low Frequency Gyrotrons for Fusion

High-Current Hollow Cathode Development *

DESIGN AND TECHNOLOGICAL ASPECTS OF KLYSTRON DEVELOPMENT

P-224: Damage-Free Cathode Coating Process for OLEDs

BEAM DIAGNOSTICS IN THE CNAO INJECTION LINES COMMISSIONING

TESLA FEL-Report

RF Upgrades & Experience At JLab. Rick Nelson

Thyratrons. High Energy Switches. Features. Description

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

INSTALLATION STATUS OF THE ELECTRON BEAM PROFILER FOR THE FERMILAB MAIN INJECTOR*

SPEAR 3: Operations Update and Impact of Top-Off Injection

Photocathode activity for. P. Michelato

vacuum analysis surface science plasma diagnostics gas analysis

Product Data Sheet 4656 EZ

Suppression of Timing drift between laser and electron beam driven photo-cathode RF gun

The hybrid photon detectors for the LHCb-RICH counters

Experimental Astrophysics Group, Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

Transcription:

FEL Gun Test Stand (GTS) from construction to beam operations Carlos Hernandez-Garcia for the FEL team CASA Beam Physics Seminar June 19 2008

The DC photocathode gun Outline The enclosure and all other systems (HVPS, drive laser, beam line, instrumentation and control, etc ) Putting all the pieces together at the same time Commissioning and operations Finally, electron beam!...but Surface Charge Limit comes along

The FEL Gun Test Stand (GTS) housing a copy of the Upgrade FEL DC photocathode gun has been built for Testing gun high voltage performance with coated electrodes for field emission suppression Dedicated operations for electron beam characterization at high charge Characterizing photocathode lifetime with improved methods and materials for better vacuum conditions A semi-load lock system for increased productivity during cathode change-out and for testing different cathode materials

The FEL and the GTS guns are identical in design and dimensions except for two features: 1. The anode plate in the GTS gun is used as a mirror for reflecting off the drive laser and illuminating the photocathode at a 40 degree angle, instead of a mirror further downstream inside the beam line used in the FEL gun. Incoming drive laser beam Anode/mirror plate 12 inches

2. The electrodes in the GTS gun are coated with a field emission suppression film. The support tube electrode starts as a single block of cross-forged, vacuum arc re-melt stainless steel. Then it is machined, hand-polished, cleaned and plasma-sputtering coated Support tube, 12.4 MV/m Ball cathode, ~ 8 MV/m GaAs wafer ~6.0 MV/m Note: Field strengths calculated for 500 kv 25 cm

SiOxNy films have demonstrated field emission suppression by more than 5 orders of magnitude compared to bare polished stainless steel electrodes (27 μa at 16 MV/m)* I (pa) 180 160 140 120 100 80 Electrode # 1 (2001)* Electrode # 2 (2001)* Electrode # 3 (2003) Electrodes # 4,5 &6 (2006) 60 40 20 0 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 E (MV/m) N. D. Theodore et al., IEEE TRANSACTIONS ON PLASMA SCIENCE, VOL. 34, NO. 4, AUGUST 2006, pp 1074-1079. * C. Sinclair et al., Proceedings of the 2001 Particle Accelerator Conference, Chichago, pp.

The latest version of the gun chamber was machined out from a single bead of vacuum arc re-melt, cross forged 316 LN Stainless Steel for low out-gassing rate

The chamber was vacuum fired in-house at 400 Celsius for 160 hours to desorb hydrogen from the walls

Phil Adderley and Marcy Stutzman reported the lowest Hydrogen out-gassing rate ever to be measured at JLab after the vacuum firing FEL gun ROR 2.0E-5 Pressure (To 1.8E-5 1.6E-5 1.4E-5 1.2E-5 1.0E-5 8.0E-6 6.0E-6 4.0E-6 2.0E-6 0 slope = 2.59E-11 Torr/sec Volume: 92.65 liters Surface: 16100 cm^2 Outgassing rate 1.49e-13 TorrL/scm^2 0 1E+5 2E+5 3E+5 4E+5 5E+5 6E+5 7E+5 8E+5 Time (seconds)

The gun assembly was done in a clean room over the ARC building. It was transported to the GTS in September 2006 and attached to a temporary vacuum chamber

The GTS enclosure was built from the FEL mechanical and HVAC room adjacent to the vault by adding concrete shielding FEL GTS

The GTS enclosure, which had to be fitted with PSS/LPSS, lighting, electrical power, LCW, Nitrogen lines, is not very large Gun SF6 tanks Gun Beam line Drive Laser Roll-up door HVPS tank Sliding concrete shield door

and filled up very quickly with the gun, the HVPS tanks, the drive laser, the beam line, and everything else that had to be installed in parallel with the gun attachment to its final vacuum chamber inside a clean room

Some rigging and ingenuity were in order to bring the high voltage power supply tank, the gun, and the rest of the equipment into the GTS thorough the roll-up door

The old IR Demo 500 kv, 5 ma DC high voltage power supply (HVPS) was refurbished and reassembled in the GTS for powering up the gun Ferrari 308 GTS Note: any resemblance in color is mere coincidence

The gun SF6 tanks were made in-house. Great accomplishment for the JLab machine shop achieving the aluminum welding certification

The Drive Laser table had to be hung up from the ceiling to provide more room for the gun tanks and the people working around the gun

A new transfer system for moving the SF6 from the gun and HVPS to the storage bag was designed and built with pneumatic valves and electronic controls

The Personnel Safety System/Laser Personnel Safety System and all of the Instrumentation and Controls were customized for the GTS

Cameras and viewers were installed and with specially developed software provided excellent images of the cathode, the electron beam and the laser spot Picture of the 25 inch diameter GaAs wafer Electron beam image on a viewer screen

The FEL Antares drive laser was modified, installed, commissioned and finally operated for producing electron beam

The beam line is very basic now, but will be improved with multi-slits and a kicker cavity for longitudinal beam profile measurements 120 cm

Before commissioning Performed Hazard Analysis (Radiation, ODH, EHS&Q, etc) Wrote Operating Safety Procedure Each system owner wrote Standard Operating Procedures (Drive Laser, SF6 transfer system, HVPS, PSS/LPSS, Concrete shield door, etc) Performed hot checkout of all systems

Drive Laser commissioning Mounting optical table on ceiling Designing and installing laser hutch with HEPA filter Installing electrical power and water cooling for the power supply Design and installation of transport system Due to 40 degree angle of incidence on cathode, the transport system was designed to produce a flat wave front at the cathode surface Plenty of energy per pulse, about 100 micro-joules LPSS had to be fully functional before drive laser commissioning

High voltage conditioning Date Event 12/06/2007 Started HV operations, achieved 85 kv 12/07/2007 Started 3-shift operations with marvelous staffing response from the FEL team, achieved 130 kv 02/01/2008 Achieved 485 kv, punched-through ceramic insulator 02/08/2008 Fixed leak but re-opened at 485 kv 02/28/2008 Ensured gun performance at 460 kv. Declared HV conditioning done It took 22 days, or 528 hours, to go from 130kV to 485kV, that s ~0.75 kv per hour In contrast, the FEL gun took about 80 man-hours to condition to 420 kv with the slowest pace at 3 kv/hour Field emission suppression coating might have contributed to excessive gas desorption during high voltage conditioning compared to FEL bare electrodes Conditioning was slowed down by resistor breaking down, HVPS control chassis problems, PSS radiation detector malfunction,

Date Event Operations 03/05/2008 First cathode ~ 2% QE but with very poor lifetime 03/13/2008 Conditioned cathode 250kV, first attempt for beam failed (magnet trim rack was off) 03/14/2008 First beam at 300kV, 110 pc with 1.5 μj 03/24/2008 Beam at 325 kv, 150 pc with 25 μj 03/26/2008 Beam at 350kV, 600 pc with 25 μj of drive laser energy 04/01/2008 Second cathode ~ 5% QE 04/02/2008 Beam at 350kV, 600 pc with 0.5 μj of drive laser energy 04/09/2008 Beam at 325kV, 1000pC with 2.5 μj of drive laser energy (picoamper-meter was clipping measurement at 600 pc) 05/06/2008 Third cathode, achieved 15% QE after realizing anode/mirror absorbs 50% of incident laser light

Got beam, but why all that laser energy per pulse to get it out from the cathode? If the cathode is 1% QE, then the energy per pulse needed to produce 1 nc is 0.25 μj Even if QE is 0.1%, laser energy should only be 2.5 μj But we needed 2.5 μj instead with a 1% QE cathode! Are they QE measurements orders of magnitude off?

We checked the QE scanner measurements by mapping the cathode QE with the electron beam on a viewer. To eliminate space charge effect, the cathode was illuminated with a DC laser at very low fluence. QE measurements for both the DC and the scanner lasers were within 10% of each other Picture of the laser beam spot on the cathode Electron beam image on the viewer screen mapping the laser beam spot on the cathode

Is it space charge limit, I=KV 3/2? No, there is no dependence on voltage over 250kV

QE~1.0% But it is Surface Charge Limit When the photocathode is excited with high densities of light (near the bandgap), the total photoemitted charge is not proportional to the light intensity QE~0.1% 0.5 1 1.5 2 2.5 QE(%) λ Q( nc) = E( μj 124 ) 1 2 3 4 5

Is there a way to lessen the SCL effect on GaAs photocathodes? We are preparing to take more data as a function of Quantum Efficiency The drive laser transport system is also being modified to change the spot size on the cathode and take data as a function of illuminated area Literature on surface charge limit suggest to increase the dopant density (nominal is Zn@10 19 /cm 3). This is something that could be tested once the semi-load-lock system is installed

Finally What was not accomplished Improve vacuum conditions due to large leak on 14-inch flange Install and operate semi-load-lock system Install Brewster windows and Molybdenum anode plate with reflective coating for enhanced reflectivity Operate gun at 500 kv due to punch-through ceramic leak at 485kV Measure beam emittance and longitudinal profile What is next Study SCL as a function of laser spot size and QE Install and commission multi-slit and kicker cavity Replace damaged ceramic with improved version (bulk resistivity) Install and commission semi-load-lock system Demonstrate reliable gun operation at 500kV Study SCL on GaAs with higher dopant density???

The GTS is the result of a fantastic team effort. Congratulations to all!! The entire FEL team The Safety Systems Group Radiation Control Group Vacuum Group Installation Group Survey and Alignment Group ESH&Q Division

Backup

Semi-load-lock A design of a semi-load lock system for replacing cathodes without perturbing system the gun chamber vacuum has been completed and fabrication awarded to McAllister Inc. This system will also allow recesiation without opening the SF6 tank, shortening the process from 3.5 to 600.5 incheshours. Bellows The bellows are extended to retract the cathode stalk and the valve is closed Valve 12 inches The bellows are compressed to insert the cathode stalk with the valve open. The compressed bellows fit within the corona shield

High voltage conditioning