Varia Tube THE SMALL AND POWERFUL CHAIN ACTUATORS RANGE

Similar documents
Product Data Sheet

RKSlimlift / EM. Two-stage lifting column

Emergency lighting units EM powerled

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

MVSI-TS. Technical features

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

WIRE CABLES PULL CABLES WR CONTROLS FLEXBALL ITALIANA CONDUIT FOR PULL CABLES WIRE FOR PULL CABLES

Single Point Flow Monitor SW118 SW119

Quick-disconnect cables. Adjustable mounting brackets

7 Lighting Technology

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

SPECIFICATION. Spec No : VSS-1402-CS603B

OpenAir. Air damper actuators for power and flexibility. Building Technologies

Pendant Light Fitting IEC Series 6470/2

Solenoid valves VZWD, directly actuated

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

10 PDUs 19 PDUs Zero-U PDUs

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

THE CABLE TRAY SYSTEM

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

Speed sensor MiniCoder GEL 2471

Everything becomes automatically more convenient! Discover the Ditec Entrematic automation.

DVS 4 # # Superb Point-Source Performance

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Label Applicator HERMA 400

CAVEX hygienic. Stainless steel gearboxes and gearmotors.

Catalogue Ignitors and power switches for HID

What s essential is invisible to the eye* *(Le Petit Prince) Antoine de Saint-Exupéry

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

BFT Bollards. A complete range of bollards

LED Driver Compact fixed output

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

LED Driver Linear / area fixed output

Bimetal Temperature Switch

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

KRF EMC Filters Installation, Operation and Maintenance Manual

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

Solenoid valves VZWD, directly actuated

Modular Lube Lubrication Systems System Controls

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

LED Driver Compact fixed output

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

T BTU/Hr Watts

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

R&S FK2900M HF Antenna Tuning Unit For stationary and shipboard applications

Designed to excel in a wide variety of sound reinforcement applications, the full range DVS 6-WH is an ultracompact 240-Watt surface mount

Revision 1.0 Parts List Salvador 1~, 3~

Absolute Encoders Multiturn

Siemens AG Safety along the complete line: SIRIUS 3SE7 cable-operated switches SIRIUS. Answers for industry.

Linealux L5 Linear Facade

Magnecraft Power Relays

Immersion Pumps HCT (High Chem) sealless

NetterVibration. Netter Electric External Vibrators Series NEG. Serving industry with vibration

Product Guide. Analog Panel Meters for use in Electrical Engineering Systems. M Series. Instruments clamping to 35 mm DIN rails W/P/ LSP BWQ BGQ

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

Series description: Wilo-Sub TWU 3 HS

Actuator for dampers ACCESSORIES. Actuators for air dampers control in ventilation and air-conditioning systems.

High performance circuit breakers

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Generator protection relay

Filters for Power Lines (Low Leakage Current)

2.9 Sigma/ 2 Plunger Metering Pumps

Pendant Light Fittings Series 6050

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

HighBand 25. TrueNet Category 6 Solutions

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

50 Hz 60 Hz VOLTAGE Connections

Panel-mounting Thermostats EM Series

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Innovation & Excellence. Index. Index. Innovation & Excellence. Introduction 4-5. Our Features 6-7. Applications

OMNIBLAST-E MODULAR LED FLOODLIGHTING SOLUTION FLEXIBILITY THROUGH MODULAR DESIGN SUPERIOR OPTICAL EFFICIENCY ADVANCED CONTROL OPTIONS

MIKRO POWER FACTOR CORRECTION COMPONENTS

CONCRETE CONSOLIDATION

Emergency lighting units EM powerled

Flat. Compact. Cost-effective. FWS Flat Change System

intro Automation for swing gates with leaves up to 4 m Kg, undergroung installation

Electromechanical Level Measurement Systems silopilot FMM 760, FMM 760 Z

Safety Light Curtains GuardShield

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

SQM40/41 Actuators for air and gas dampers

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Lt DELTA USA, Inc

Meteor Product Catalogue

Features. Specifications. Finish. Notes

Frequency Converter Fv

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LCS2 Cat. 6 RJ 45 Patch panels and units

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Transcription:

Varia Tube THE SMALL AND POWERFUL CHAIN ACTUATORS RANGE

Contents VARIA TUBE 3 TUBE LOCK 6 2 www.giesse.it

Varia Tube Varia Tube: The latest member of Giesse chains actuators family widens the supply of force (350N) and strokes (300, 600, 800 and 1000 mm) adapting to diverse kind of windows from outward and Bottom-Hung to dormer windows and domes. The external case made of aluminium contributes to an elegant design, while the compact dimensions (34,6 x 37) allow surface mounting with a minimal visual impact as well as recessed mounting and into curtain walls mounting Top-Hung Smoke and heat extraction system (RWA): entirely made of metal, Varia Tube is certified under EN 12101-2 and can be used for RWA installation Remarkably quiet (41 db) while maintaining high power standards. Due to accurate research, it has been possible to develop and combine an innovative gear motor with a new electronic concept of energy performance, so that the actuator gives the right power when required Sophisticated electronics equipped with a microprocessor allow to install the actuator in industrial as well as in domestic environments, where it can be easily connected with already existing devices to transmit window open / close signal Syncro technology (patented) permits to connect up to 8 Varia Tube actuators together to work in perfect synchronization, without any external devices When combined with the electromechanical Tube Lock and perimetrical hardware, it can form a burglar-resistant system and reaching a high thermal K through the perfect closing of the window Easy to install thanks to rapid release support brackets and fixing brackets (patented), to self-adjusting end stroke and immediate stroke selection through dip-switches Reliability tested through 10,000 cycle at maximum load. The actuators undertake 100% functional test before being delivered all over the world MADE IN ITALY Bottom-Hung Parallel Window Varia Tube 230 V AC Code Description 07875 Varia Tube 230 V 300 07876 Varia Tube 230 V 600 07877 Varia Tube 230 V 800 07878 Varia Tube 230 V 1000 07896 Varia Tube Syncro 230 V 300 07897 Varia Tube Syncro 230 V 600 07898 Varia Tube Syncro 230 V 800 07899 Varia Tube Syncro 230 V 1000 Varia Tube RWA 24 V DC Code Description 07804 Varia Tube RWA 24 V 300 07805 Varia Tube RWA 24 V 600 07806 Varia Tube RWA 24 V 800 07807 Varia Tube RWA 24 V 1000 07815 Varia Tube RWA Syncro 24 V 300 07816 Varia Tube RWA Syncro 24 V 600 07817 Varia Tube RWA Syncro 24 V 800 07818 Varia Tube RWA Syncro 24 V 1000 www.giesse.it 3

Varia Tube Technical data Power control over the entire stroke (stop in case of overload) Progressive starting (Soft start) and closing (Soft stop) Stroke end: electronic opening stroke-end with variable stroke that can be selected at any time using dip-switches, self-adjustment closing position and automatic regulation to the overlap Relax function: relaxation of mechanical parts after each stroke-end due to stop for power absorption The actuator can be connected in parallel and synchronised thanks to Syncro (patented) technology in compliance with Directive 2004/108 CE (EMC) and 2006/95 CE (B.T.) Grey painted (RAL 9006) aluminium case provided with white cable (230V) or grey cable (24V), metallic support and fixing brackets with without screws rapid release (patented) Four links in two-rows chain made of stainless steel to grant high resistance to corrosion and diverse weather conditions Table of force-stroke relation Pull Push 400 300 200 100 (N) (mm) 100 200 300 400 500 600 700 800 900 1000 Brackets Spare parts 05921 05922 05923 05920 05924 Code Description 05921 Bottom-Hung bracket 05922 Top-Hung bracket 05923 Top-Hung horizontal bracket Code Description 05920 Frame bracket (CP) 05924 Rapix fixing clip 4 www.giesse.it

34,5 72,5 51 23,8 37 43,6 24 V = 185 230 V = 245 300 24 V = 408 / 230 V = 468 600 24 V = 624 / 230 V = 624 800 24 V = 667 / 230 V = 727 1000 24 V = 764 / 230 V = 824 34,5 79,5 72,5 51 37 43,6 23,8 Varia Tube 230 V AC 24 V DC Syncro 230 V AC Syncro 24 V DC Pull force Push force Variable strokes Syncro technology (patented) 350 N 350 N (see table of force-stroke relation) 300 (100, 175) 600 (400, 500) 800 (600, 700) 1000 (800, 900) mm Power supply voltage 110 230 V AC 24 V DC 110 230 V AC 24 V DC Frequency 50/60 Hz 50/60 Hz Current at nominal load 0,23 A (230V) 0,80 A 0,23 A (230V) 0,80 A Power absorbed at nominal load 29 W 19,2 W 29 W 19,2 W Speed 11 / 9,6 mm/s 11 / 9,6 mm/s Stroke duration at nominal charge (open) Stroke duration at nominal charge (close) Yes Stroke 300 / 600 / 800 / 1000 = 28 / 54 / 72 / 90 s Stroke 300 / 600 / 800 / 1000 = 36 / 67 / 88 / 109 s Double electrical insulation Yes B.T. Yes B.T. Service type S 2 of 3 min Operating temperature -20 C +70 C Degree of protection for electrical devices Soft stop / start Relax function Frame rebated overlap self-learning Connection in parallel IP32 Yes Yes Self-determination of the position Power supply cable type and length H05VV-F 2 m FRR / 2 2,5 m Opening end stroke Closing end stroke Overload protection Yes Electronic through dip-switches At absorption of power At absorption of power Dimensions for 230V (strokes 300 / 600 / 800 / 1000) 34,6 x 37 L = 468 / 624 / 727 / 824 mm Dimensions for 24V (strokes 300 / 600 / 800 / 1000) 34,6 x 37 L = 408 / 624 / 667 / 764 mm Static holding force Weight 0,9 / 1,4 / 1,8 / 2,2 Kg 0,8 / 1,3 / 1,7 / 2,1 Kg 2000 N 0,9 / 1,4 / 1,8 / 2,2 Kg 0,8 / 1,3 / 1,7 / 2,1 Kg Connection with Tube Lock No Yes No Yes Data provided in these illustrations is not binding and subject to change without prior notice. www.giesse.it 5

Tube Lock Tube Lock is the electric lock specially designed to automatically open / close the multi-point locking system of Top-Hung, Bottom-Hung and parallel windows, in combination with Varia Tube 24 V chain actuators. The presence of locking points along the perimeter of the window significantly increases its air-water-wind tightness. Tube Lock features reduced dimensions (25 26 mm) with recessed installation inside a slot in the window frame, without visual impact. Top-Hung Tube Lock is quiet and is equipped with advanced electronics. Tube Lock works in combination with Varia Tube 24 V actuators: at the opening signal, the lock releases the locking points before the actuator starts to work, whereas it blocks the locking points once the window is brought to closing. The push / pull force (600 N 850 N at start) ensures high operational reliability even with a high number of locking points. Bottom-Hung Plus Quiet and powerful Can be combined in parallel with up to 8 Tube Locks with Syncro units of the Varia Tube actuator range In compliance with Directive 2004/108 CE (EMC) and 2006/95 CE Tested 10,000 cycles at maximum load Technical features 600 N thrust force Integrated electronic control of the opening / closing sequence Power supply voltage: 24 V DC Stroke selectable (18 or 36 mm) by dip switch Finishing: silver anodised Parallel Window 18 Rotating pawl driver 18 External case in extruded aluminium Very small case size Electronic control by micro-processor. Self-lubricating gears Rotating fixing bracket Dip switch housing 6 www.giesse.it

Matching actuators Varia Tube RWA 24 V Tube Lock 24 V DC item 07809 Push and pull force Stroke Power supply voltage Current at nominal load Power absorbed at nominal load No-load speed Maximum no-load stroke duration Double electric insulation 600 N 850 N at start 18 mm / 36 mm 24 V DC (20,4 30 V AC) 0,85 A during the opening / closing 1,2 A for amperometric block ~ 20 W 5 mm/s 4 s (18 mm) 7.2 s (36 mm) Very low tension Duty rate 30% Service Case material Operating temperature S2 1 minute Aluminium alloy extrusion -20 C +70 C Degree of protection for electrical devices IP 40 Opening / closing stroke end Operating with chain actuators Operating without chain actuators Silicone cable Overload protection in open / close Electronically set Selectable Selectable 3 x 0,5 mm 2 2,00 m Supply cut due to power overload Dimensions (mm) 25,5 x 25,5 x 357 Weight (kg) 0,56 Connectable with Data provided in these illustrations is not binding and subject to change without prior notice. Varia Tube RWA 24 V DC Varia Tube RWA Syncro 24 V DC www.giesse.it 7

ENGINEERED COMPONENTS FOR THE FENESTRATION INDUSTRY Schlegel Sealing Systems Giesse Hardware Systems GIESSE S.p.A. A Company of Schlegel International Via Tubertini, 1 40054 Budrio (BO), Italy Tel: +39 051 8850000 Fax: +39 051 8850001 Email: info.it@schlegel.com Care has been taken to ensure that the contents of this publication are accurate, but GIESSE and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only. All dimensions are in mm and are nominal. GIESSE reserve the right to change specification without prior notice. GIESSE s names and logos and all related trademarks (including GIESSE, GIESSE symbol, C.H.I.C., Giesse NP, NP symbol, GOS and QID ), trade names and other intellectual property are the property of Schlegel Acquisition Holdings Limited trading as Schlegel International and cannot be used without its express prior written permission. All rights reserved. Schlegel Acquisition Holdings Limited trading as Schlegel International 2017. U0755001 05/2017 www.giesse.it www.schlegel.com