Revision History. SDG2000X Firmware Revision History and Update Instructions

Similar documents
Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Advanced Test Equipment Rentals ATEC (2832)

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

4 MHz Lock-In Amplifier

BER MEASUREMENT IN THE NOISY CHANNEL

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4

LeCroy Digital Oscilloscopes

2 MHz Lock-In Amplifier

The Measurement Tools and What They Do

QUAD LFO MANUAL V SE 14TH AVENUE PORTLAND OR USA

ASYNCHRONOUS COUNTER CIRCUITS

Rack-Mount Receiver Analyzer 101

Experiment 7: Bit Error Rate (BER) Measurement in the Noisy Channel

PicoScope 6407 Digitizer

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

Fluke 190-Series II Firmware Upgrade V11.44

Agilent Technologies. N5106A PXB MIMO Receiver Tester. Error Messages. Agilent Technologies

Agilent 6000 Series Oscilloscope Demo Guide

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

PB-507. Advanced Analog & Digital Electronic Design Workstation Instruction Manual. Revision: 2/2014

DSM GHz Linear Chirping Source

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Manual for the sound card oscilloscope V1.41 C. Zeitnitz english translation by P. van Gemmeren, K. Grady and C. Zeitnitz

Digital Storage Oscilloscopes 2550 Series

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

Application Note 11 - Totalization

Signal Stability Analyser

This guide gives a brief description of the ims4 functions, how to use this GUI and concludes with a number of examples.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Transmitter Interface Program

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

Instrument Firmware Release Notes

C ch optical MADI & AoIP I/O. MASTER mode: A C8000 frame may be clocked via MADI input or AES67 network. AoIP Dante Brooklin II OEM module

Advanced Skills with Oscilloscopes

C Module Description

HD-A60X Series Asynchronous-Synchronous operate manual

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

PulseCounter Neutron & Gamma Spectrometry Software Manual

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

Troubleshooting Your Design with the TDS3000C Series Oscilloscopes

PowerMonic. FAQs [2/12]

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

C Module Description

User Manual. SDS2000 Series Digital oscilloscope UM01020-E03A 2015 SIGLENT TECHNOLOGIES CO., LTD.

MODULAR DIGITAL ELECTRONICS TRAINING SYSTEM

SPG700 Multiformat Reference Sync Generator Release Notes

Datasheet SHF A

PicoScope 6407 Digitizer

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

SigPlay User s Guide

2 MHz Lock-In Amplifier

Department of Communication Engineering Digital Communication Systems Lab CME 313-Lab

Advanced Test Equipment Rentals ATEC (2832)

User Manual. This document applies to firmware version 2.2 and above.

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

013-RD

Spectrum Analyser Basics

Experiment 4: Eye Patterns

imso-104 Manual Revised August 5, 2011

SDS1000C Specifications

SPG8000A Master Sync / Clock Reference Generator Release Notes

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

S I N E V I B E S FRACTION AUDIO SLICING WORKSTATION

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

IP LIVE PRODUCTION UNIT NXL-IP55

QPHY-USB3 USB3.0 Serial Data Operator s Manual

Introduction. NAND Gate Latch. Digital Logic Design 1 FLIP-FLOP. Digital Logic Design 1

WVR500 Waveform/Vector Monitor

fxbox User Manual P. 1 Fxbox User Manual

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Additional instructions Memograph M, RSG45 Advanced Data Manager

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone

TG700 TV Signal Generator Platform Release Notes

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

25 MHz Digital Storage Oscilloscope

Setup. Connecting to a DMX Interface

Marks and Grades Project

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Broadcast Television Measurements

Getting Started with the LabVIEW Sound and Vibration Toolkit

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

ControlSpace Designer software 5.1

Patchmaster. Elektronik. The Pulse generator. February 2013

Digital Video Recorder

Measurements on GSM Base Stations According to Rec

Static Timing Analysis for Nanometer Designs

Major Differences Between the DT9847 Series Modules

ADE-32 OCTOCONTROLLER

DW Drum Enhancer. User Manual Version 1.

Agilent Error Performance Analyzer Quick Reference ( ) This booklet is intended as a handy reminder of the fundamentals of BER

Transcription:

Revision History Date Version Revision 2/28/2018 2.01.01.23R8 Optimized calibration and PV process on the production line. 8/29/2017 2.01.01.23R7 1. Supported system recovery from U-disk. 2. Fixed a bug which may cause the generator report a false over voltage alarm when start-up. 3/23/2017 2.01.01.23R3 1. Allow 0 Hz for CH Frequency In MOD Modes PM, AM, DSB-AM, ASK, PSK 2. Allow MOD frequency > CH Frequency In MOD Modes PM, DSB AM, ASK 3. Allow DSB-AM, AM MOD Modes In TrueArb Mode 4. Up Followed by Down Sweep Mode is Supported in Linear Sweep (No Change for Log Sweep) 5. Added ARB waveform name to display, allowing user to know what Arb waveform is loaded 6. Fixed some bugs a) Arb Waveforms In DDS Mode Have One (Small) Glitch Per Cycle b) Built in Ramp waveform has a flat spot issue at the rising slope zero crossing right at the SYNC pulse. c) Power Up Last Does Not Remember SRate/Frequency Setting d) MOD Type = DSB AM Has Amplitude Issues 9/30/2016 2.01.01.22R5 1. Permit setting the frequency to 0. 0 Hz would mean that the DDS accumulated phase word would be held/not change with time. 2. Fixed some bugs a) Single Channel AM Modulation Output Amplitude Is 9.3% Low b) Manual trigger can not trigger both channels at the same time c) SW bug regarding the modulation with noise d) Frequency Coupling/Phase Lock Does Not Work in TrueArb e) Instrument Powers Up With Wrong Waveforms f) TrueArb mode CH Coupling Bug When Entering Samples/Sec g) Display graphic error for displayed wave shape h) Can not save the last state after the update 6/16/2016 2.01.01.21R2 1. Added Waveform Combination function, to support combining ch1 and ch2 from internal to generate complex signals such as sine + noise and two-tone. The set path: Utility Output Setup Wave Combine 1 / 6

Date Version Revision 2. Added mode selection: Pase-Locked and Independent. In Pase-Locked mode the generator resets both channels every time the frequency is changed to maintain synchronization automatically. In Independent mode the generator will not reset any channel when the frequency is changed; the phase difference between channels is random. The set path: Utility mode 3. Fixed some bugs i) Can not delete files with illegal characters j) In burst mode, press the soft key for cycles, it changes to infinite right off the bat k) External modulation input inverted compared to convention l) Can not remember the clock source setting m) Some unexpected glitches when enabling the output or change the parameters 1/16/2016 2.01.01.17R5 1. Added statistic function in counter mode NOTE: After 2. Supported using method 2 from our "generating being updated to this release, mulitphase waveforms" application note (refer to http://www.siglentamerica.com/prodcut-pxzl.aspx?id=9 the generator 0&tid=16&T=2) to synchronize 2 units of SDG2000X cannot be 3. Fixed some bugs backward to n) A bug in file system could cause the generator previous never startup releases any o) DHCP does not run at power up more p) Channel lock phase can be wrong in modulation sometimes q) Error in calculation of frequency deviation in counter mode r) Instrument does not allow CH1 and CH2 to both use the external input for the modulation source simultaneously in tracking mode s) Downward compatibility of.xml state file t) Unable to delete files with uncommon character(s) in their names 11/30/2015 2.01.01.16R2 1. Added phase deviation option in channel tracking mode 2. Optimized the User Interface, including save/recall, arb, etc. 3. Supported long pressing the Output key to switch the load between 50ohm and HiZ 4. Supported to autosave the imported binary file (*.bin). 5. Fixed some bugs 2 / 6

Date Version Revision a) Unexpected change on Phase difference between channels in sweep mode when switching the style between linear and log b) Channels not aligned when the frequency of one channel is integral multiple of another c) Wrong sweep profile when using manual trigger d) Unexpected reset on output when setting illegal parameters e) Unstable waveform at the beginning of after enabling the output f) Display error when switching between TrueArb and DDS in Arb mode g) Frequency deviation display problem in Counter mode h) Wrong project name in system information i) When pressing the waveform button, the parameter button flashes j) Unable to set variable load value without touch screen k) Unexpected digit jumping when setting parameters with the knob l) Set CH2 to invert and then do a system -> default, the option will return to normal, but the signal will stay inverted. 9/30/2015 2.01.01.15R2 1. Supported adjustable noise bandwidth 2. Supported harmonic 3. Added some built-in arbs, so the number of arb types increased to 196 4. Fixed some bugs 8/27/2015 2.01.01.12R1 The first formal release 3 / 6

Compatibility between Versions Source Object Compatibility Version Version 2.01.01.23R7 2.01.01.23R8 Tested. 2.01.01.23R5 2.01.01.23R8 Tested. 2.01.01.23R3 2.01.01.23R8 Tested. 2.01.01.22R5 2.01.01.23R8 Tested. 2.01.01.21R2 2.01.01.23R8 Tested. 2.01.01.17R5 2.01.01.23R8 Tested. 2.01.01.16R2 2.01.01.23R8 Not Tested 2.01.01.15R2 2.01.01.23R8 Not Tested 2.01.01.12R1 2.01.01.23R8 Not Tested 4 / 6

Update Instructions WARNING: DO NOT shut off the instrument until the update is completed. 1. Copy the update file (*.ads) to a FLASH type U-disk, and then connect the U-disk to the USB host port of the instrument. 2. Press the Utility key on the front panel, and then softkey System ->Page 1/2 -> Firmware Update, to enter the interface of the file browser. 3. Select USB Device thru the knob on the front panel, press Browse, and then select the correct ads file using the knob 5 / 6

4. Press Recall to start the update. A progress bar is displayed during the update. After the update is completed, the generator will restart automatically. WARNING: DO NOT shut off the instrument until the update is completed. 6 / 6