Laying of cables and lines in electrical installations and data networks

Similar documents
Cable installation guidelines

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

Processing Specification MiniBridge IDC

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

High Voltage Cables kv. Handling and Operating Instructions

Cables for robot applications

Flygt Submersible Motor Cables

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

Cyclo Series. user manual. MartinArchitectural

LED MODULES READYLINE DL

LED Driver Compact dimming

LED control gear Compact fixed output

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT. MTM Garments Ltd.

Test-Report chainflex

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

Figure 1: Device components

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

General Wiring and Installation Guidelines. Typical Mounting Installations Electrical Connections General Guidelines Common Questions & Answers

ABB i-bus EIB Universal dimmer 6155 EB for Installation

HDBT Installation Guide

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED

OPTICAL FIBRE CABLE NETWORK 2004/1

Gamma instabus. Technical product information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

LED Driver Compact fixed output

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

SWA Cable - BS5467 Steel Wire Armoured PVC Eland Product Group A9S

LED Driver Linear / area fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Underground Installation of Optical Fiber Cable by Pulling

LED Driver Compact fixed output

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Installation of Optical Fiber

Modular pulse operated latching relay 16 A

ELECTRICAL SAFETY INSPECTION REPORT

Automatic Test System AT-S + with STAR + Technology Features

ELECTRICAL SAFETY FOLLOW UP INSPECTION REPORT (8th) Factory Name Address Factory ID

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

MICROMASTER Encoder Module

Identification - electrical services

Numerous cables one solution: Serpa cable organization

Section Communications Optical Fiber Backbone Cabling

Newsletter

Pocket guide to cable management

NZQA unit standard version 3 Page 1 of 7. Demonstrate knowledge of telecommunications cable systems

RZ1-K BS EN XLPE LSZH Flexible Cable

3 Cleaning. 4 Technical data

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

CHAINFLEX CABLES TESTED FOR GUARANTEED PERFORMANCE

HD4K18GB-FO-xx-MM. HDMI 2.0 Active Optic Cables. Instruction Manual

HighBand 25. TrueNet Category 6 Solutions

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Operating Instructions Dimmer for V Incandescent Lamps

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

SECTION COMMUNICATIONS HORIZONTAL CABLING

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Installation Manual IPT Installation of skillet systems with 125 A track current. MV a-E.

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Triax TechInfo. Installing and pulling Fibre Optic cables

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

THE CABLE TRAY SYSTEM

Panel-mounting thermostats, type series EM

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Active Optical 4K HDR HDMI Cable

TENDER SUMMARY. Tender Title:

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

SECTION COMMUNICATIONS HORIZONTAL CABLING

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Ø 1000 * 588 mm 50 kg

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

User s Manual Model WF100 Extension Cable for EXA100

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

PREMIUM 5e F/UTP PRODUCTS

Tab 10 - The NESC and Underground Applications. Restricted Siemens Industry, Inc All rights reserved.

FIBER OPTIC CABLE PULLING

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

PROFIBUS Assembling Guideline Version 1.14 May 2015 Order No: 8.022

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Transcription:

Technical bulletin Laying of cables and lines in electrical installations and data networks Date: 08/2006 This technical bulletin provides you with information on specific technical subjects. It is based on the current rules and regulations and on our current test results. The contents of this document is not legally binding.

These days, our working practices are primarily based on the availability of electrical energy and connections to data networks. The cables necessary for this can stretch for several hundreds of metres or even for kilometres, in small or medium-sized scenarios. When laid in installation systems in walls, ceilings or underfloor areas, they form a dense network. For many reasons protection against electric shock, fire prevention and for reasons of functional safety the regulations from DIN VDE and from the German Insurance Association (VdS guidelines) contain stringent requirements for cables, their laying and handling and for the operation of electrical installations. Erection regulations for data networks (DIN EN 50173) control the structures and define their performance parameters. Regulations for cable laying inside and outside buildings are in preparation (EN50174). 1 Protection aims of standardisation The primary aims of the erection standards are: protecting lives preventing fires maintenance of functions 2 Fire protection Fire protection and fire protection measures are especially significant in the area of the electrical installations. Some of the main causes of fires in electrical cables are: high-resistance short circuits or faults to earth, e.g. on mechanically or thermally damaged cables faulty electrical connections (loose contact) breaks in the neutral wire incipient damage of insulation from over-voltages overloads heat build-up This list shows what impacts cable laying and later use of the cabling system can have on their operational safety. If, for example, cables are stressed by an overload, then this will shorten their lifespan (= insulation potential of the jacketing) greatly, resulting in short circuits and faults to earth. @ Rp / 07.08.06 / e_kabel und Leitungen in Starkstromanlagen.doc / Page 2 of 8

3 Laying cables for electrical installations The laying of electrical cables are adequately regulated in DIN VDE 0100-520. Outside influences on the cable system should be avoided as far as possible in the installation. For this, the cables should be run through the cable management system, cable support systems, piping, within walls, using cable clips and also protected conductors should be used. Cables may be laid without protection in raised or cavity floors, provided that the mechanical loads do not exceed the limit values of the cables. 4 Influences on lines and cables Lines and cables are subjected to the following loads during installation and operation: thermal loads mechanical loads outside influences Thermal loads can include high ambient temperatures, temperatures resulting from electrical loads and installation. DIN VDE 0298 Part 4 contains guidelines for current carrying capacities. 5 Mechanical loads Mechanical loads can include tensile loads during installation and during subsequent changes to the electrical system, the bending radii and the fixing of the cables using clips, strain relief devices, etc. 5.1 Tensile load The tensile load of electrical cables during laying may not exceed 50 N/mm² for fixed installations and 15 N/mm² for movable resources (DIN VDE 0298 Part 3). This means that there is a maximum tensile load of 225 N on a cable of 3 x 1.5 mm² during installation. Excessive tensile forces cause the cable material to flow. Changes to the material structure and reductions in the cable cross-section led to increased current densities and heating of the cable, with premature ageing of the cable insulation. @ Rp / 07.08.06 / e_kabel und Leitungen in Starkstromanlagen.doc / Page 3 of 8

5.2 Bending radii The product standard DIN VDE 0298 Part 3 specifies the permitted bending radii for electrical cables, related to the average cable diameter. Permitted bending radii: For multiwire cables with plastic insulation: 4 x Ø For flexible, freely movable conductors: Ø = 8 to 12 mm: 4 x Ø Ø = 12 to 20 mm: 5 x Ø For flexible, fixed cables: Ø = 8 to 12 mm: 3 x Ø Ø = 12 to 20 mm: 4 x Ø If the bending radii are not maintained during cable laying, this can cause the material to stretch and compress, leading to changes in the mechanical structure of the cable, with the consequence that the electrical properties will be impaired. 5.3 Cable fastening The fastening of cables using clips, cable ties, strain relief devices, etc., must be carried out in such a way that the electrical properties of the cables and lines are not lost during operation at the expected loads (including overloads and short circuits). Flexible cables should be used for movable resources. In contrast to fixed laying, tensile forces must be expected at the clamping points due to the movement. For this reason, the electrical resources must be equipped with appropriate strain relief devices (e.g. cable grips on the unit cans). Their function is tested according to the product specification in DIN VDE 0606, in which a tensile force of 100 N (25x in the axis direction without jolts) is applied to the cable. After the test, the cable (jacketing) may not be damaged and may not have moved more than 2 mm within the strain relief device. @ Rp / 07.08.06 / e_kabel und Leitungen in Starkstromanlagen.doc / Page 4 of 8

6 Cables and lines for data networks Cables and lines for data networks are subject to special requirements regarding their transmission properties. The erection specification DIN EN 50173 defines the structure and the quality of a network for all three installation levels: primary, secondary and tertiary. After the system has been set up, the function and the transmission properties are measured using the specified parameters as proof of correct first installation. After subsequent changes to cabling, DIN EN 50173 requires a measurement of the transmission properties. During installation, the laying types, laying temperatures, tensile loads and permissible bending radii are specified for the cables. 6.1 Tensile loads The permissible tensile loads are laid down in the manufacturer's cable specifications and, for copper cables, range from 190 to 380 N, and from 100 to 500 N for fibre-optic cables, depending on the cable type and structure. 6.2 Bending radii DIN EN 50173 defines the bending radii for copper cables. Smallest bending radius during installation: 8x the cable diameter. Smallest bending radius after installation (only once): 4x the cable diameter. In the case of fibre-optic cables, the manufacturers specify a minimum bending radius of 30 mm for single wire cables. For bundled cables, bending radii of 15 to 20x the external diameter must be maintained. @ Rp / 07.08.06 / e_kabel und Leitungen in Starkstromanlagen.doc / Page 5 of 8

7 Planning and installation A permanent, functional electrical installation for electrical installations and data networks is dependent on the proper installation according to the standard. The basis for this is the planning, which is not specified during the design phase (i.e. how many connections at any given point) but during later use. 7.1 Cables and lines in electrical installations When using lines and cables in raised floors, there are, as specified earlier, no special cable laying requirements. So-called open laying is recognised as the most practical form of installation, providing that the laying regulations are complied with. This means that cables may be pulled for the purpose of installation and the identification of specific cables, although complete connection units (unit cans with installation units) may not be pulled through cavities on account of the high loads for cables and terminals. The relatively low permissible tensile loads for the cables mean that there may be damage to cables and lines, on account of the expected obstacles, such as other laid cables, pipes, double butt supports otherwise found, with the possible risk of damage. 7.2 Cables and lines in data networks In the field of data networks, cabling should be carried out with great care, to ensure future usage and high transmission rates. Data lines for static network cabling (not patch cables) change their transmission properties after mechanical loads from pulling, bending and relaying. Common faults and longer response and reaction times due to more frequent (automatic) data transmission repeats can be tangible and visible consequences of the changes. After first installation, always try to avoid pulling the data cables @ Rp / 07.08.06 / e_kabel und Leitungen in Starkstromanlagen.doc / Page 6 of 8

Appendix overview of standards and guidelines Safety standards DIN VDE 0100 DIN VDE 0107 DIN VDE 0108 DIN VDE 0113 DIN VDE 0116 DIN VDE 0132 DIN VDE 0160 Erection of low-voltage installations with rated voltages up to 1,000 V Low-voltage installations in hospitals and medical rooms outside hospitals Low-voltage installations and safety power supplies on construction sites Safety of machinery electrical equipment of machines Electrical equipment for furnaces and ancillary equipment Measures to be taken in the event of fire in or near electrical installations Electronic equipment for use in power installations Guidelines VdS 2025 VdS 2097-8 Cable and line systems, guidelines on damage prevention Installation ducts and cable systems with function maintenance Erection regulations DIN VDE 0100-520 Wiring systems DIN EN 50173 Requirements for generic cabling systems EN 50174 Installation of cabling systems Cable product regulations (for heavy-current installations) DIN VDE 0250 Cables, wires and flexible cords for power installation DIN VDE 0250-816 Heat-resistant silicon hose lines DIN VDE 0267 Halogen-free cables with improved fire characteristics DIN VDE 0276 Power cables DIN VDE 0298 Application of cables and insulated lines in power installations DIN VDE 0472 Testing of cables and insulated lines Product definitions DIN VDE 0603 and DIN VDE 0606 DIN VDE 0604, DIN VDE 0634 DIN VDE 0605 DIN VDE 0606, DIN VDE 0609 DIN VDE 0619 Consumer units and meter panels Cable ducting systems Conduit system for electrical installations Connecting devices Cable glands @ Rp / 07.08.06 / e_kabel und Leitungen in Starkstromanlagen.doc / Page 7 of 8

Reference sources for standards and definitions DIN VDE Normen VDE-Verlag GmbH Merianstrasse 29 63069 Offenbach or Beuth-Verlag GmbH Burggrafenstrasse 4 10 10772 Berlin VBG regulations Carl-Heymanns Verlag KG Luxemburger Strasse 449 50939 Cologne MLAR Publication in DIBt communications Deutsches Institut für Bautechnik Kolonnenstrasse 30L 10829 Berlin DIBt communications can be obtained from Verlag Ernst & Sohn Bühringstrasse 310 13086 Berlin VdS guidelines Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Amsterdamer Strasse 174 50735 Cologne @ Rp / 07.08.06 / e_kabel und Leitungen in Starkstromanlagen.doc / Page 8 of 8