Mini-spectrometers. RC series. Compact and low cost C11009MA, C11010MA: for installation into measurement equipment.

Similar documents
Mini-spectrometers. TM series. High sensitivity type (integrated with backthinned type CCD image sensor) C10082CA/C10083CA series

Mini-spectrometers. RC series. Compact and low cost C11009MA, C11010MA: for installation into measurement equipment.

MS series. Parameter Min. Typ. Max. Unit Driving voltage V Power consumption mw Video rate khz

Mini-spectrometers. TG series. High sensitivity type (integrated with backthinned type CCD image sensor) Optical characteristics

TM series. Trigger function included

Mini-spectrometer. TG series. Enhanced near infrared sensitivity type. C9405CB. High sensitivity in near infrared region

FT series. Spectral response range 790 to 920 nm Spectral resolution Typ. 0.4 nm

Mini-spectrometer. TG series. For near IR, integrating optical system, image sensor and circuit. C9406GC, C9913GC, C9914GB

TM series TM-UV/VIS-MOS

Mini-spectrometer. TG series. Enhanced near infrared sensitivity type. C9405CB. High sensitivity in near infrared region

Mini-spectrometer. TM series. Trigger function and a high sensitivity CMOS image sensor included. C11697MB. Optical characteristics

Mini-spectrometer. TF series. Compact and thin, built-in high-sensitivity CMOS image sensor for Raman spectroscopy C14214MA. Applications.

mini-spectrometer TG series Long-wavelength type (to 2.55 μm) nearinfrared C11118GA Optical characteristics (Ta=25 C)

Driver circuit for CCD linear image sensor

TF series. Spectral response range 340 to 830 nm Spectral resolution Typ. 2.3 nm

Driver circuit for CMOS linear image sensor

Variable gain and stable detection even at high gains

Driver circuit for InGaAs linear image sensor

Driver circuit for MPPC

Photon counting module

Driver circuit for CCD linear image sensor

Micro-spectrometer C12666MA. Finger-tip size, ultra-compact spectrometer head integrating MEMS and image sensor technologies.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

InGaAs multichannel detector head

Driver circuit for CCD linear image sensor

Optics modules. Absorbance measurement module with built-in photodiode array, optical elements, current-tovoltage. C13398 series.

Driver circuits for CCD image sensor

APD modules. Operates an APD with single 5 V supply (standard type, short-wavelength type) C12702 series.

Mini-spectrometer. SMD series C14384MA-01. High sensitivity in the near infrared region (to 1050 nm), ultra-compact grating type spectrometer

Photosensitive area (mm) 4 4. Peak sensitivity wavelength (nm) Supply voltage Dark state. Max. Vcc max. Tstg Min. Max. (ma) (V)

APD modules. APD module integrated with peripheral circuits. C12703 series. Selection guide. Block diagram

Mini-spectrometers. MS series. Ultra-compact mini-spectrometer integrating MEMS and image sensor technologies.

Applications. l Image input devices l Optical sensing devices

Designed for back-thinned CCD area image sensor

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

Application OCT. Dimensions (mm) Weight (g) Operating temperature* 1 Storage temperature* 1 λ=1.55 μm (V) (mw)

High-speed photodiodes (S5973 series: 1 GHz)

Peak sensitivity wavelength λp (nm) Photosensitive area (mm)

Signal processing circuit for 1-D PSD

MPPC modules. MPPC array modules for very-low-level light detection, 16 ch analog output. C13368/C13369 series (Analog output type)

Power supply for MPPC

Micro-spectrometer C12666MA. Finger-tip size, ultra-compact spectrometer head integrating MEMS and image sensor technologies.

Signal processing circuit for 1-D PSD

Driver circuit for InGaAs linear image sensor

Near infrared image sensor (0.9 to 1.7 µm) with high-speed data rate

Driver circuit for CCD image sensor

UV-LED MODULE. UV Irradiation Intensity Distribution Graphs

Signal processing circuit for 2-D PSD

Signal processing circuit for 2-D PSD

Power supply for MPPC

MPPC modules. Photon counting module with built-in MPPC. C series C10751 series. Selection guide

Reverse voltage VR max. Electrical and optical characteristics (Typ. Ta=25 C, unless otherwise noted) Short. Temp. S coefficient (A/W) of

PbSe photoconductive detectors

Infrared detector modules with preamp

APD module. Variable gain, stable detection even at high gain. C Applications. Features. Sensitivity vs.

Effective photosensitive* 2 area size. Storage temperature Tstg (mm) ( C) ( C) S φ0.2 φ0.5 S φ to to +100 S9075

Si PIN photodiodes. High-speed detectors with plastic package. Structure. Absolute maximum ratings

NMOS linear image sensor

Parameter Specification Unit Photosensitive area mm Package Glass epoxy - Seal material Epoxy resin -

Applications. Photosensitive area size. Storage temperature Tstg (mm) (mm 2 ) (V) ( C) ( C) S

Parameter Specification Unit Photosensitive area mm Package Glass epoxy - Seal material Silicone resin -

Si PIN photodiodes. High-speed detectors with plastic package. Structure. Absolute maximum ratings

New product of near infrared (to 900 nm) detection

RGB color sensor. Effective photosensitive area. Green, Red: 2.25 Blue : 4.5

Peak emission wavelength: 4.3 μm

Driver circuit for CMOS linear image sensor

Photodiode modules. C10439 series. Integrates photodiode for precision photometry with low-noise amp.

Photosensitive area size (mm) Reverse voltage VR max (V) R to +60

MCT photoconductive detectors

Driver circuits for photodiode array with amplifier

Effective photosensitive area. Photosensitive area size

These Si photodiodes have sensitivity in the UV to near IR range. They are suitable for low-light-level detection in analysis and the like.

M=100, RL=50 Ω λ=800 nm, -3 db

NMOS multichannel detector head

Effective photosensitive area (mm) Photosensitive area size

1-D PSD with small plastic package

Short wavelength type APD. Effective photosensitive area (mm) Effective photosensitive area size* 2

MPPC (multi-pixel photon counter)

Suppressed IR sensitivity

Peak emission wavelength: 3.9 μm

MCT photoconductive detectors

Si photodiode. Applicable to lead-free solder reflow and wide temperature range. S9674. Absolute maximum ratings

InAsSb photovoltaic detector

Low bias operation, for 800 nm band

Applications. Number of terminals. Supply voltage (op amp) Vcc

Parameter Symbol Specification Unit Photosensitive area - ɸ0.8 mm Package mm

Between elements measure. Photosensitive area (per 1 element)

Photo IC diode. Plastic package shaped the same as metal package. S SB. Absolute maximum ratings (Ta=25 C)

Accessories for infrared detector

CCD multichannel detector heads

Flat panel sensor C10500D-42 is a digital X-ray image sensor newly developed as a key device for real-time X-ray imaging.

CMOS linear image sensors

Photo IC diode. Wide operating temperature: -40 to +105 C. S MT. Absolute maximum ratings (Ta=25 C)

CCD multichannel detector heads

InAsSb photovoltaic detector

InGaAs PIN photodiode arrays

16-element Si photodiode arrays

Photosensor with front-end IC

All-in-one solutions For applications with imaging challenges, we offer a wide range of TDI solutions.

CMOS linear image sensor

Transcription:

Compact and low cost, : for installation into measurement equipment HAMAMATSU mini-spectrometer is a family of compact polychromators integrated with a reflection grating and a CMOS linear. Two types are available: mini-spectrometer modules (, ) with a driver circuit, and minispectrometer heads (, ) for installation into measurement equipment, which contain an optical system and an in a compact case. Mini-spectrometer modules have a USB port that connects to a PC for spectrum data collection. They come with sample software for setting measurement conditions, acquiring and saving data, and displaying data graphs, as well as with driver software and DLL. In mini-spectrometer heads, incident light is dispersed into a spectrum which is photoelectrically converted by the image sensor and output as video signals. Features Applications, (Module) Integrating spectrometer head and drive circuit Spectral measurement using PC No external power supply required: USB bus power A/D conversion: 16-bit Wavelength conversion factor * 1 is recorded in internal memory., (Head) For installation into measurement equipment Integrating optical system and into a compact case : 2 2 2 mm : 2 20 mm Low cost, Installation into measurement equipment Chemical measurement Visible light source testing Color measurement, etc., Installation into measurement equipment Chemical measurement Measurement of saccharic in fruits Various industrial measurements Selection guide Spectrometer module Product No. Product type Spectral response range Spectral Resolution (nm) (nm) RC-VIS-MOS 340 to 70 9 RC-SWNIR-MOS 640 to 50 Interface USB 1.1 Light input method fiber Spectorometer head (for installation into measurement equipment) RC-VIS-MOS 340 to 70 9 RC-SWNIR-MOS 640 to 50 - fiber *1: A conversion factor for converting the pixel number into a wavelength is recorded in the module. Calculation factor for converting the A/D converted count into the input light intensity is not provided. www.hamamatsu.com 1

,,, Structure of, The, are offered in small size, low-cost units achieved by integrating optical components into a glass body. The reflective grating mounted on the glass body is a plastic-molded replica grating. Optical component layout Slit Grating Image sensor Glass body Collimating function Focusing function KACCC034EB Optical characteristics RC-VIS-MOS RC-SWNIR-MOS Parameter (Spectrometer module) (Spectrometer head) (Spectrometer module) (Spectrometer head) Unit Spectral response range 340 to 70 640 to 50 nm Spectral resolution Max (Spectral response half width) * 2 9 nm Wavelength reproducibility * 3 ±0.5 nm Wavelength temperature dependence 0.05 nm/ C Spectral stray light * 2 * 4-30 db Broadband stray light * 2 * 5-25 -23 db *2: Depends on the slit opening. Values were measured with the slit listed in the table General ratings / Absolute maximum ratings. *3: Measured under constant light input conditions *4: When monochromatic light of λ=550 nm (, ) or λ=50 nm (, ) is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured at a wavelength 40 nm longer or shorter than the input wavelength. *5: The ratio of the transmittance in the transmitting wavelength region of an optical filter (/: OG530, /: RG50) to that in the blocking region Electrical characteristics Parameter (Spectrometer module) (Spectrometer head) (Spectrometer module) (Spectrometer head) Unit A/D conversion 16-16 - bits Integration time 5 to 000-5 to 000 - ms Interface USB 1.1 - USB 1.1 - - General ratings/absolute maximum ratings Parameter (Spectrometer module) (Spectrometer head) (Spectrometer module) (Spectrometer head) Unit Dimensions 55 (W) 4 (H) 0 (D) 2 (W) 2 (H) 2 (D) 55 (W) 4 (H) 0 (D) (W) 20 (H) 2 (D) mm Built-in head - - - Image sensor Infrared enhanced type (S37-256N) - Number of pixels 256 pixels Slit * 6 70 (H) 550 (V) 70 (H) 2500 (V) μm Optical N.A. 0.22 - core diameter 600 μm Optical fiber connector SMA905 - Operating temperature * 7 +5 to +40 C Storage temperature * 7-20 to +70 C *6: Entrance slit aperture size of the incorporated *7: No condensation 2

,,, Dimensional outlines (unit: mm, tolerance unless otherwise noted: ±0.5) (4 ) M2.6 depth 3 1 ± 5 (2 ) M2.6 depth 5 Flexible board VIS Spectrometer 55 21 2 45 4 14 2 2 0 ± 3.5 KACCA0240EA.5 ± 0.2 KACCA0241EA (4 ) M2.6 depth 3 (2 ) M2.6 depth 5 1 ± 5 Flexible board SWNIR Spectrometer 55 2 45 0 4 KACCA0242EA 2 ± 3.5.5 ± 0.2 20 KACCA0243EA Connection example (transmission light measurement) Light to be measured is guided into the entrance port of through an optical fiber and the spectrum measured with the built-in is output through the USB port to a PC for data acquisition. There are no moving parts inside the unit so stable measurement are obtained at all times. An optical fiber that guides light input from external sources allows a flexible measurement setup. Light input method For mini-spectrometer head (, ), an SMA connector is attached with the other end of the optical fiber. Light can be easily guided by hooking up this connector to the SMA receptacle of an external unit. If the optical fiber connected to mini-spectrometer is shorter than needed, an optical fiber of the desired length can be added by connecting a relay unit. PC Visible fiber light source (Halogen lamp) USB cable Minispectrometer A9762-01 (sold separately) SMA connector Quartz cell (For holding liquid sample) KACCC046EA 3

,,, Optical fibers for light input (A9762-01, A9763-01) As optional accessories for use with mini-spectrometer modules (, ), HAMAMATSU provides UV-VIS (UV resistant) and VIS-NIR optical fibers (core diameter 600 μm). The mini-spectrometer heads (, ) integrate an optical fiber. Type No. Product name Applicable mini-spectrometer Core diamater (μm) A9762-01 UV-VIS optical fiber (UV resistant) 600 A9763-01 VIS-NIR optical fiber 600 Specification N.A.=0.22 Length 1.5 m, both ends terminated with SMA905D connector N.A.=0.22 Length 1.5 m, both ends terminated with SMA905D connector Electrical connections with an external circuit (, ) The flexible printed circuit board protruding from the head or module is used make electrical connections to an external circuit. Thickness: 0.3 6 ± 0.5 4 ± 0.5 Mating connectors: FH12-20S-0.5SV vertical type (Made by HIROSE electric) FH12 52745-2090 horizontal type (Made by MOLEX).5 ± 0.2 Black tube Unit: mm KACCC0261EA Pin No. Terminal Pin Terminal I/O Discription name No. name I/O Discription NC - No connection NC - No connection NC - No connection GAIN I Gain setting NC - No connection A.GND - Analog GND EOS O EOS (end of scan) signal A.GND - Analog GND A.GND - Analog GND ST I Sensor scan start signal A.GND - Analog GND CLK I Sensor scan sync signal H-CMOS compatible VIDEO O Video signal output SDA O Thermosensor output signal A.GND - Analog GND SCL I Thermosensor driver signal A.GND - Analog GND D.GND - Thermosensor digital GND +5 V I Power supply of : +5 V VCC I Power supply of thermosensor: +3.3 V Note: Pins 4 to and 12 to 16 are connected to the. For information on drive specifications, refer to S377/S37 series datasheet. Pins 17 to 20 are connected to the internal thermosensor (DALLAS DS1775R). 4

,,, Dedicated software (, ) Installing the dedicated software package (containing sample software, device driver, DLL)* into your PC allows running the following basic tasks: Measurement data acquisition and save Measurement condition setup Module information acquisition (wavelength conversion factor, polychromator type, etc) Graphic display Arithmetic operation Pixel number to wavelength conversion Dark subtraction Comparison calculation with reference data (transmittance, reflectance) Gaussian approximation (peak position and count, FWHM) Note: This product cannot operate with the software that comes with the mini-spectrometer TM or TG series. *: Compatible OS: Microsoft Windows Professional Edition 2000 (SP3 or later) and XP (SP1 or later) Device driver and DLL for controlling hardware are also provided. You can develop your own measurement programs by using a software development environment that includes Microsoft Visual C++ and Visual Basic* 11. The DLL provides functions such as USB port open/close, measurement condition setup, measurement data and module information acquisition. *11: Operation of the device driver and DLL has been verified only with Microsoft Visual C++ and Visual Basic. Microsoft Visual C++ and Microsoft Visual Basic are either registerd trademarks or trademarks of Microsoft Corporation in the United States and other countries. Measurement examples (1) White LED and 3-color LED measurements () (2) Reflected light from color paper () 000 Relative reflectance with 0 % being equal to reflectance of white plate A/D count 30000 25000 20000 15000 000 5000 White LED 0 300 0 400 450 500 550 600 650 700 750 00 Wavelength (nm) 3-coior LED KACCB00EA Relative reflectance (%) 0 90 0 70 60 50 40 30 20 0 340 Blue Green Wavelength (nm) Red 390 440 490 540 590 640 690 740 790 KACCB02EA Accessories (, only) USB cable Dedicated software (sample software, device driver, DLL) The and conform to the European EMC directives (Applied standard: EN 61326-1 Class B). 5

,,, Mini-spectrometer line-up Type No. C02CA C02CAH C02MD C03CA C03CAH C03MD C9404CA C9404CAH C9404MC C9405CA C9405MC C9406GC C9913GC C9914GB C1111GA TM series TG series TG series Type TM-UV/VIS-CCD TM-UV/VIS-CCD High resolution TM-UV/VIS-MOS TM-VIS/NIR-CCD TM-VIS/NIR-CCD High resolution TM-VIS/NIR-MOS TG-UV-CCD TG-UV-CCD High resolution TG-UV-MOS TG-SWNIR-CCD TG-SWNIR-MOS TG-NIR Non-cooled type TG-cooled NIR-I Low noise (cooled type) TG-cooled NIR-II Low noise (cooled type) Spectral response range (nm) 200 400 600 00 00 1200 1400 1600 0 2000 2200 2400 2600 200 to 400 200 to 00 320 to 00 500 to 10 900 to 1700 10 to 2200 TG-cooled NIR-III Low noise (cooled type) 900 to 2550 Spectral resolution Max. (nm) 6 1* 6 7 Image sensor Back-thinned type CCD (λ=320 to 900 nm) Back-thinned type 1* CCD (λ=320 to 900 nm) Back-thinned type 3 CCD Back-thinned type 1* CCD 3 5 Back-thinned type (λ=550 to 900 nm) CCD 5 NMOS linear (λ=550 to 10 nm) 7 20 InGaAs linear * Typ. For installation into measurement equipment Spectral response range (nm) Spectral resolution Type No. Type Max. Image sensor 200 400 600 00 00 1200 1400 1600 0 2000 2200 2400 2600 (nm) RC-VIS-MOS Spectrometer module RC-SWNIR-MOS Spectrometer module RC-VIS-MOS Spectrometer head RC-SWNIR-MOS Spectrometer head 340 to 70 340 to 70 640 to 50 640 to 50 9 9 Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. 2009 Hamamatsu Photonics K.K. www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Solid State Division 1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 4-55 Japan, Telephone: (1) 53-434-3311, Fax: (1) 53-434-514 U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 69, Bridgewater, N.J. 007-09, U.S.A., Telephone: (1) 90-231-0960, Fax: (1) 90-231-121 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr., D-2211 Herrsching am Ammersee, Germany, Telephone: (49) 0152-3750, Fax: (49) 0152-265 France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 912 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294, Fax: (44) 1707-325777 North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171 41 Solna, Sweden, Telephone: (46) -509-031-00, Fax: (46) -509-031-01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-9-1-733, Fax: (39) 02-9-1-741 Cat. No. KACC1157E01 Mar. 2009 DN 6