Inductive coupling. 10 mm +/-0.2 mm

Similar documents
TW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

TW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

Mobile data carrier TW-L49-46-F-B128

Read/Write Head TNLR-Q80L400-H1147L

Read/Write Head TNSLR-Q42TWD-H1147

Read/write head TN-CK40-H1147

Read/Write Head TN-CK40-H1147

Read/write head TN-M18-H1147

Read/Write Head TN-M30-H1147

Capacitive sensor BCT5-S18-UP6X2T-H1151

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Inductive sensor BI1.5-EG08K-Y1

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Inductive sensor With analog output BI15-M30-LI-EXI

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Inductive sensor NI3-EG08K-Y1-H1341

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM8

Rotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181

Inductive sensor NI10-M18-Y1X-H1141

EtherCAT Set in IP20 TI-BL20-E-EC-S-4

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT

Set for Simple I/O Communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-2

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC

BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P

The full range of performance

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Connectivity for Ethernet

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

Pressure sensors with display

UHF RFID Tag Data Sheet LXMS21ACNP-184

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

HARTING Ethernet cabling cables and connectors, 4 wire

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

MRX1 1. Getting to know your MRX1 wireless controller

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

PTC Series. Professional Temperature Calibrator PTC-155/350/425/660

Your Global Automation Partner. Ultrasonic Sensors

EX-IQ-Box Digital Signal Interface Module Specifications

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Product catalogue 2010

ATEX UHF RFID Long Range Reader with Integrated Antenna Zone 2 / 22 ISO

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

OM2000N INSTALLATION MANUAL

CML 700i Measuring light curtain with integrated control unit and interfaces for even simpler operation

DOGM GRAPHIC SERIES 128x64 DOTS

The HSMB-C110 is a right-angle package with the universally accepted dimensions of 3.2 x 1.0 x 1.5 mm. This part is ideal for

TUC: Universal thermostat

MultiDimension Technology (MDT) Geartooth Encoder is a non-contact incremental encoder for spindle rotation speed or displacement measurement.

Label Applicator HERMA 400

BML-M0 _-I -A _-... User's Guide

DDF-SE. Application example. Feed-through Stationary Rotary Feed-through. Max. speed 500 revs/ min. Air feed-through Up to 6x

Datasheet IVU.box.touch

Electrical connection

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Heating films. Articelnumber build:

Connectorized and Pre-Loaded HIGH PERFORMANCE CABLE CARRIER SYSTEMS

Speed sensor MiniCoder GEL 2471

Surface Mount Multilayer Ceramic Chip Capacitors for High Temperatures 200 C

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Ultra-Small Surface Mount Coaxial Connectors mm Mated Height

D2101V IP VIDEO DOOR STATION. Brushed Stainless Steel 1 Call button

High Frequency Ceramic SMT Chip Inductor SCL160808CS Series

Mini Gateway USB for ModFLEX Wireless Networks

D2102V IP VIDEO DOOR STATION. Brushed Stainless Steel 2 Call buttons

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

4-in-1 Motor Controller CAN

Installation instructions Cable transit device Roxtec RS ES Ex

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

R&S Spectrum Rider FPH Handheld spectrum analyzer

LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Easy programming Robust. Flexible. FPS Flexible Position Sensor FPS. Field of Application. Advantages Your benefit. Options and special Information

IMPAC Infrared Thermometers

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Electrical connection

MAGICSTRAP Technical Data Sheet Murata part number : LXMS31ACNA / LXMS31ACMD

CTC Series. Compact Temperature Calibrator

Transcription:

Data carrier for direct mounting on metal The mounting position (arrow) as well as the alignment of the data carrier towards the read/write head must be observed under all circumstances in order to achieve a maximum read/write distance When installed recessed in metal by 1 mm, the write/read distance reduces to % Extended storage temperature range: The tags must undergo adequate stress tests within the proposed temperature processes before deployment. The following stress test was performed on this data carrier: Cyclic temperature stress: min. at 20 C min. at 160 C. Number of tested cycles: 100T This successfully performed test does not imply suitability for a specific hightemperature application, but merely serves as proof of the basic usability. Type designation Ident no. 04 Data transfer Operating frequency Memory type Chip Memory Memory Freely usable memory Number of read operations Number of write operations Typical read time Typical write time Radio communication and protocol standards Inductive coupling 1.6 MHz EEPROM EM42SLIC 6 Byte Read/Write 128 byte unlimited 10 2 ms/byte ms/byte ISO 169 Minimum distance to metal Ambient temperature Storage temperature 0 mm -40 +8 C -40 +8 C 1 C, 1000 h 160 C Diameter Housing height Housing material Active area material Protection class 10 mm +/-0.2 mm 4. mm +/-0.mm open housing, potted Plastic, PPS, black IP68 Packaging unit Remark to product 1 Testing of the application under real operatdata carrier for direct mounting on/in metal. ing conditions is therefore essential, especiala recommendation for adhesives, the require- ly with read/write on-the-fly! ments of the FDA and the EU for incidental food contact can be requested from TURCK. This recommendation does not relieve the user of an examination with regard to the suitability for his application. Functional principle The HF read/write heads operating at a frequency of 1.6 MHz, form a transmission zone the size of which (0 00 mm) varies, depending on the combination of read/write head and data carrier. The read/write distances mentioned here only represent standard values measured under laboratory conditions and free from any influences caused by materials. The read/write distances of data carriers suitable for mounting in/on metal were determined in/on metal. Attainable distances may vary by up to % due to component tolerances, mounting conditions, ambient conditions and material qualities (especially when mounted in metal) Edition 20-0-1T1::9+02:00 EEPROM, memory 6 byte 1/ Hans Turck GmbH & Co.KG ñ D-442 Mülheim an der Ruhr ñ Witzlebenstraße ñ Tel. 0208 492-0 ñ Fax 0208 492-264 ñ more@turck.com ñ www.turck.com

Read/write heads Dimensions Type designation Ident - no. TB-M-H1 Read-write distance Transfer zone Minimum distance between two read-write heads Recommended (mm) length width offset [mm] 4 4 12 4 12 4 12 4 1 9 1 9 1 1 1 1 1 1 1 120 1 120 0001 TB-EMWD-H1 0224 TN-M-H1 0002 TN-EMWD-H1 022 TN-M-H1/C 028 TB-M-H1 000 TB-EMWD-H1 0221 TN-M-H1 0004 TN-EMWD-H1 0222 TN-M-H1/C 0 TN-CK40-H1 0006 TN-CK40-H1/C Edition 20-0-1T1::9+02:00 02 2/ Hans Turck GmbH & Co.KG ñ D-442 Mülheim an der Ruhr ñ Witzlebenstraße ñ Tel. 0208 492-0 ñ Fax 0208 492-264 ñ more@turck.com ñ www.turck.com

Read/write heads Dimensions Type designation Ident - no. HT-IDENT-H1 Read-write distance Transfer zone Minimum distance between two read-write heads Recommended (mm) length width offset [mm] 1 120 24 8 2 2 80 40 40 2 2 80 40 40 2 2 80 40 40 20 42 240 20 42 240 20 42 240 4 4 4 026 TN-Q-0.1-RS4.4T 02 TNSLR-Q80WD-H1 04 TNSLR-Q80WD-H1/C0 021 TNSLR-Q80WD-H1/ C 10000112 TNSLR-Q42TWD-H1 0424 TNSLR-Q42TWD-H1/C1 022 TNSLR-Q42TWD-H1/C 0 TB-Q08-0.1-RS4.4T 0 TB-Q08-0.1-RS4.4T/C 08 Edition 20-0-1T1::9+02:00 TB-Q08-0.1-RS4.4T/C4 06 / Hans Turck GmbH & Co.KG ñ D-442 Mülheim an der Ruhr ñ Witzlebenstraße ñ Tel. 0208 492-0 ñ Fax 0208 492-264 ñ more@turck.com ñ www.turck.com

Compatible handhelds PD-IDENT-HF-RWBTA (0601) Handheld for mobile reading and writing to data carriers. Equipped with WLAN 802.11a/b/g/n and Bluetooth; incl. docking station with power supply, USB cable, and TURCK RFID Software TA-HF. PD-IDENT-HF-S2D-RWBTA (0602) Handheld for mobile reading and writing to data carriers. Equipped with WLAN 802.11a/b/g/n, Bluetooth and 2 D barcode scanner; incl. pistol grip, docking station with power supply, USB cable, and TURCK RFID software TAHF. Edition 20-0-1T1::9+02:00 PD-IDENT-HF-L1D-RBUP-SMART (064) Handheld for mobile reading and writing to data carriers. Keyboard functions (HID) for wireless transmission of data via Bluetooth (also to IOS devices) or USB. Barcode 1 D laser scanner and only three buttons for ease of use. 4/ Hans Turck GmbH & Co.KG ñ D-442 Mülheim an der Ruhr ñ Witzlebenstraße ñ Tel. 0208 492-0 ñ Fax 0208 492-264 ñ more@turck.com ñ www.turck.com

Mounting instructions The left figure shows how the read/write head must be aligned towards the data carrier. As an example here the read/write head TNSLRQ42TWD-H1 is shown (instructions valid for all suitable read/write heads). The orientation of the data carrier (arrow) is to be observed. A: Recommended distance B: Maximum distance C: Length of the transmission zone at recommended distance The corresponding values are listed in the table. To achieve the largest possible distance, the data carrier must be positioned off-center to the read/write head, or rather move along the housing edges during the readwrite process. The figure on the right shows the typical spread of a data transmission zone Glueing the data carrier: Step 1: First, mill a sufficiently large bore hole (see drawing) Step 2: Fill the hole with sufficient adhesive or potting material Step : Press the data carrier into the hole. Observe the orientation of the data carrier (see arrow) A subsequent alignment of the data carrier in the hole is not possible. Edition 20-0-1T1::9+02:00 Step 4: In order to avoid holes and undercuts, first, led harden the adhesive after inserting the data carrier. This also avoids any unintentional rotation of the data carrier. Then, fill up with adhesive and flush with the surface. / Hans Turck GmbH & Co.KG ñ D-442 Mülheim an der Ruhr ñ Witzlebenstraße ñ Tel. 0208 492-0 ñ Fax 0208 492-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description Drawing R10-M Zeichnung R10-M Bore is to insert the data carrier into metal Edition 20-0-1T1::9+02:00 Example of application ApplikaApplication example overhead conveyor system tionsbeispiel 6/ Hans Turck GmbH & Co.KG ñ D-442 Mülheim an der Ruhr ñ Witzlebenstraße ñ Tel. 0208 492-0 ñ Fax 0208 492-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use Edition 20-0-1T1::9+02:00 This tag corresponds to the requirements for simple apparatus according to EN 6009-,.12.2 and may, under certain conditions, be used in the Ex area. The requirements of EN 6009- must be observed in this case. / Hans Turck GmbH & Co.KG ñ D-442 Mülheim an der Ruhr ñ Witzlebenstraße ñ Tel. 0208 492-0 ñ Fax 0208 492-264 ñ more@turck.com ñ www.turck.com