BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P
|
|
- Louise Holt
- 5 years ago
- Views:
Transcription
1 On-Machine kompakt fieldbus I/O blokları CANopen slave 10, 20, 50, 125, 250, 500, 800, or 1000 kbps Two 5-pin M12 male receptacles for fieldbus connection 2 rotary coding switches for node-address IP 69K M12 I/O ports LEDs indicating status and diagnostics Electronics galvanically isolated from the field level via optocouplers Tip kodu İdent no digital PNP outputs, 24 VDC Max. 0.5 A per output Nominal system voltage System power supply Voltage supply connection Nominal current V+ Max. current V+ Admissible range Vo Nominal current Vo Max. current Vo 24 VDC fieldbus ve yedek güç ile 2 x M12, 4 pimli 30 ma 4 A 11 30VDC 100 ma 4 A Fieldbus transmission rate 10 kbps 1 Mbps Adjustment transmission rate Automatic detection Fieldbus address range Fieldbus addressing 2 dec. Rotary coding switches Fieldbus connection technology 2 M12 5-pin Fieldbus termination External Service interface RS232 interface Digital outputs Output type Type of output diagnostics Sensor supply (V SENS) Kanal başına çıkış akımı Çıkış voltajı Output delay Load type Load resistance, resistive Load resistance, inductive Lamp load Switching frequency, resistive Switching frequency, inductive Switching frequency, lamp load Kısa devre koruması PNP Channel diagnostics 24 VDC from supply voltage 0.5 A 24 VDC from supply voltage 3 ms Resistive, inductive, lamp load > 48 ò < 1.2 H < 3 W < 200 Hz < 2 Hz < 20 Hz evet 1 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
2 Boyutlar Mounting Ağırlık Housing material Muhafaza rengi Window material Material screw Material label Zemin etiketi malzemesi IP Derecesi 113 x 71 x 32.5mm 2 5,4 mm delik çapları, 1,7 Nm tork 390 ± 20 g Glass fiber reinforced nylon, nickel-plated connector siyah Lexan nikel kaplamalı pirinç Polikarbonat kaplamalı polyester Nickel-plated brass IP67 IP69K Operating temperature ºC Saklama sıcaklığı ºC Relative humidity 15 to 95% (non-condensing) Titreşim testi acc. to IEC Extended vibration resistance - up to 20 g (at 10 up to 150 Hz) For mounting on base plate or machinery Darbe testi acc. to IEC Electromagnetic compatibility acc. to IEC Onaylar CE, culus 2 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
3 CANopen Fieldbus cable (example): RSC RKC 572-2M ident-no. U0323 or RSC-RKC572-2M ident-no Digital Outputs Extension cable (example): RK 4T-2-RS 4T ident-no. U or RKC4T-2-RSC4T/TEL ident-no Wiring Diagram Auxiliary Power Extension cable (example): RKC 4.4T-2-RSC 4.4T ident-no. U5264 or RKC4.4T-2-RSC4.4T/TEL ident-no / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
4 Status: Station LED LED Color Status Description IO'lar KAPALI Güç kapalı KIRMIZI AÇIK Yetersiz güç beslemesi KIRMIZI YANIP SÖNÜYOR (1Hz) Sapma istasyonu konfigürasyonu KIRMIZI YANIP SÖNÜYOR (4 Hz) Modül veri yolu iletişimi yok YEŞİL AÇIK İstasyon TAMAM YEŞİL YANI SÖNÜYOR Kuvvet modu etkin ERR - OFF Normal operating mode RED ON CAN communication interrupted BUS GREEN ON NMT slave status operational ORANGE ON NMT slave status pre-operational RED ON NMT slave status stopped ERR & BUS RED FLASHING (4 Hz) Invalid node ID Status: I/O LED LED Color Status Description D * OFF Diagnostic disabled RED ON Station / module bus communication failure RED FLASHING (0.5Hz) Summarized diagnostic DO channels OFF Status channel x = 0 (OFF), diagnostic disabled 0 3 GREEN ON Status channel x = 1 (ON) RED ON Short-circuit/overload at channel x * D LED also indicates gateway diagnostic 4 / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
5 I/O Data Map OUTPUT BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit DO 1 3 DO 1 2 DO 1 1 DO / 5 Hans Turck GmbH & Co.KG ñ D Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel ñ Fax ñ more@turck.com ñ
EtherCAT Set in IP20 TI-BL20-E-EC-S-4
A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BLident M12 extension
More informationBL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog
More informationSet for Simple I/O Communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-2
Tip kodu İdent no. 1545074 Kanal sayısı 2 Boyutlar (W x L x H) 72.5 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between interface
More informationBL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 4 analog
More informationBL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog
More informationSet for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8
Type code Ident no. 1545077 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between
More informationCapacitive sensor BCT5-S18-UP6X2T-H1151
M18 1 threaded barrel Plastic, PA12-GF30 Teach-in and configuration via buttons on the device, pin 5 and IO-Link Wiring Diagram Functional principle Type designation Ident no. 2101100 Remark to product
More informationRead/Write Head TNLR-Q80L400-H1147L
For roller conveyors The approach direction of the data carrier can be both, diagonal as well as longitudinal to the read/write head. Rectangular, 80 x 400 mm, height 25 mm Active face on top Plastic,
More informationRead/Write Head TNSLR-Q42TWD-H1147
Rectangular, height 42.5 mm Active face on top Plastic, PA12-GF30 /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030424 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 610 mm Laser class 1, red, 655 nm, acc.
More informationUltrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151
Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 310 mm Laser class 1, red, 655 nm, acc.
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 100 mm Laser class 1, red, 655 nm, acc.
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 300 mm Laser class 1, red, 655 nm, acc.
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPhotoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ
Transmission of process value and parametrization via IO-link Cable with male end, PVC, M8 x 1, 4-pin, 150 mm Protection class IP67 LED, all-round visible Coaxial optics Sensitivity adjusted via teach
More informationUltrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD
ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment
More informationRead/write head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated only via BL ident
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationContactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 16 bits singleturn Process value in 32 bit telegram 3 error bits 16 bits singleturn 15
More informationPhotoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7
8 mm connector, 4-pin Visible red light Programming via teach cable or multi-function button Operating voltage: 10 30 VDC IO-Link 2 x PNP output, changeover contact Light/dark operation Wiring Diagram
More informationContactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length
More informationRead/Write Head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030006 Mounting conditions Non-flush Ambient temperature -25
More informationInductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151
Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog
More informationRead/write head TN-M18-H1147
Threaded barrel, M18 x 1 Chrome-plated brass Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated solely via BLident interface module M12 x 1 male,
More informationRadio Transmission System Point-to-point Gateway DX80G2M6S-PM8
External antenna (RG58 RP-SMA connection) Integrated signal strength indicator Configuration via DIP switch Modbus RTU communication, RS485 interface Deterministic data transmission Frequency hopping FHSS
More informationContactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationRead/Write Head TN-M30-H1147
Threaded barrel, M30 x 1.5 Chrome-plated brass /S2503 Connectors /S2500 Connectors Type designation Ident no. 7030004 Mounting conditions Non-flush Ambient temperature -25 +70 C Operating voltage 10 30
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationContactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151
Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output
More informationContactless encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED LED indicates measuring range Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024,
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationContactless encoder Ri360P0-QR24M0-HESG25X3-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. SSI output 25 bit, Gray-coded SSI clock rate: 62.5 KHz 1 MHz Single or multiturn,
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationRotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181
Clamping flange, Ø 58 mm Solid shaft, Ø 10mm x 20mm Optical measuring principle Shaft material, stainless steel Protection class IP67 on the shaft side -40 +85 C Max. 6000 rev/min (continuous operation
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationTW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission
EEPROM, memory 8 byte Functional principle The HF read/write heads operating at a frequency of 13.56 MHz, form a transmission zone the size of which (0 0 mm) varies, depending on the combination of read/write
More informationMobile data carrier TW-L49-46-F-B128
EEPROM, memory 128 byte Functional principle The HF read/write heads operating at a frequency of 13.56 MHz, form a transmission zone the size of which (0 500 mm) varies, depending on the combination of
More informationTW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission
FRAM memory 2 kb Functional principle The HF read/write heads operating at a frequency of 13.5 MHz, form a transmission zone the size of which (0 0 mm) varies, depending on the combination of read/write
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationInductive coupling. 10 mm +/-0.2 mm
Data carrier for direct mounting on metal The mounting position (arrow) as well as the alignment of the data carrier towards the read/write head must be observed under all circumstances in order to achieve
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationThe full range of performance
sensors sensors P sensors PS series series The full range of performance The sensors of this series cover all important pressure ranges from -1 +600 bar with an accuracy of 0.5% f.s.. Bar, psi and further
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationConnectivity for Ethernet
Industrial Ethernet standards such as Modbus TCP, EtherNet/IP, PROFINET and Ether- CAT have firmly established themselves in automation technology. These real-time Ethernet solutions differ both in terms
More informationtechnical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current
Inductive Sensors: high-temperature ü For ambient temperatures of up to +230 C ü With integrated electronics, up to +180 C ü With external electronics, up to +230 C ü Excellent long-term reliability (according
More informationPressure sensors with display
412 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 sensors P sensors PK series series Multifaceted pneumatic specialists The PK pressure sensors are especially designed for pneumatic
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationYour Global Automation Partner. Ultrasonic Sensors
Your Global Automation Partner Ultrasonic Sensors At TURCK, we understand that not every application is the same. That s why we dedicate ourselves to finding the optimal engineered solution for every application;
More informationDCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor
Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital
More informationADVANCED ultrasonic sensors with analog output. Dimensioned drawing
ADVANCED ultrasonic sensors with analog output Dimensioned drawing en 07-2017/02 50124880 4...20 ma 0...10 V 25 400mm 150 1300mm 15-30 V DC We reserve the right to make changes PAL_DMU418BX3LTVC_en_50124880.fm
More informationAbsolute encoders multiturn
The Sendix multiturn encoders 5868 and 5888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a maximum resolution
More informationAdvantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0
Advantys STB Standard Profibus DP Network Interface Module Applications Guide 890USE17300 Version 2.0 31002957 01 31002957 01 2 Table of Contents Safety Information....................................
More informationYour Global Automation Partner. Ultrasonic Sensors. Operating Instructions
Your Global Automation Partner RU CK40 RU CP40 Ultrasonic Sensors Operating Instructions Contents 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com Contents 1
More informationPSI-MOS-RS232/FO 850 E Serial to Fiber Converter
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationFibre Optic Modem ODW-611
Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.
More informationLXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O
Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number
More informationLONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationDATA SHEET Panorama Rudder Indicator, TRI-2
DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationStandard RS232 RS ma
1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision
More informationSERIES 400 SERIES 620
x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationPROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS
INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More informationLONWORKS Fibre Optic Router
LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS
More informationFiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements
NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected
More informationLVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:
HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement
More informationPRINCIPLES AND APPLICATIONS
GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,
More informationCEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)
7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN) produced according to ISO 9001: 2000 Ver. 0.2/11.04.2006 Art.-Nr.: 104 057 E 1 / 8 7-Segment Double
More informationSTBART0200K standard analog input kit STB - 2 I - 15 bits + sign
Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationAdvantys STB DATA SHEET. Advantys STB Output Module. Description. Features
Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The
More informationLASER. Laser-Position-Transducer. LLD Series. Key-Features:
LASER Laser-Position-Transducer LLD Series Key-Features: Content: Technical Data.2 Technical Drawings...2 Types Of Output...3 Configurationsoftware...4 Order Code...5 Options & Accessories.5 - Measurement
More informationDigital output modules
Appendix 374 Digital output modules Order number Figure Type DO 8xDC 24V 2A DO 16xDC 24V 1A DO 16xDC 24V 2A DO 16xDC 24V 0.5A manual operation General information Note - - - - Features 8 outputs, in groups
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationMB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN
Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically
More informationMID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J
MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance
More informationSupply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red
EnOcean-DALI-Controller, series BL, light controller Interfaces: 1x DALI Master, 1x EnOcean Master bi-directional Supply voltage: 230 V AC, for ERCO DALI track The EnOcean-DALI-Controller BL-201-05-868
More informationEVENT INPUT/OUTPUT MODULE [PUME]
PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm
More informationMX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en
MX1609 T Thermocouple amplifier Type T Data sheet Special features 16 inputs (electrically isolated) Thermocouple mini type T Measuring point identification Data rate up to 300 Hz 8 internal cold junction
More informationINSTALLATION & USER GUIDE
INSTALLATION & USER GUIDE Digidim 458 8-Channel Dimmer STEP 1 Assemble Dimmer Unit STEP 2 Mount Dimmer Chassis STEP 3 Electrical Installation STEP 4 Attach Module and Make Connections STEP 5 Replace Cover
More informationENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:
ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental
More informationFibre optic router for TP/FT-10 LRW-112PP
Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT
More informationMBUS 10 RS232 TO MBUS LEVEL CONVERTER
Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit
More information1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.
ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read
More informationDATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.
Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features
More informationManual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12
R60722.0002 - Index 3 Analog (U/I) Manual Absolute multiturn encoder Order code: 8.M36X1.XXXX.XX12 Order code: 8.M3661R.XXXX.XX12 Order code: 8.M5861.XXXX.XX12 Publisher Kübler Group, Fritz Kübler GmbH
More informationE6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm
Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationSlot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON
Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationOrdering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.
Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous
More informationAssembly. Front view. LEDs. Parametrization interface. Power Bus
otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit
More informationEZ-LIGHT K50 Modbus Series Multicolor Indicators
EZ-LIGHT K50 Modbus Series Multicolor Indicators Datasheet Rugged, compact multi-color indicators in several package types Built-in flashing and strobing capability High intensity models for outdoor applications
More informationInstruction Manual. Universal Flow Controller Model 261 / 261-EC-01
Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation
More informationOrdering details. Approval. Classification
Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation
More information