INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Similar documents
XTM72E & F Real-Time Clock Modules

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

7 Day Digital Light Switch with Optional Dusk Start

24Hour/7Day Electronic Timeswitch

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

7 Day Digital Programmer 3 Channel Surface Mount

16 Amp Electronic 24 Hour/7 Day Time Controller

7 Day Digital Programmer

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Philips LightMaster. KNX Timeclock Installation and Operation Manual

FW/S Digital time switch 2CDG120039R0011 D GB F I E NL. Installation and operating instructions FW/S DCF antenna GPS antenna SELV MENU

Digital Time Switch. Installation & Operating Instructions

7 Day Digital Time Switch

XTM72 Exerciser Timer Module

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

Digital Economy Seven Programmer

2 Hour Electronic Boost Timer

1. General Information:

Simply clever! The digital DIN-rail time switches by Grässlin

Radio-control universal dimmer (built-in type) Installation Instructions

1 Channel Multi-Purpose Programmer User Instructions

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

Operating instructions. Universal timer switch display

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

ST9100C User Guide. Features

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Dimming actuators GDA-4K KNX GDA-8K KNX

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.


Programmable time switches Multiple function - daily/weekly

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

USER MANUAL AL-Control 1 PRO

s w i t c h i n g c o n t r o l l i n g c o u n t i n g

Model IQ4-PC User Manual Revision Date:

DTL-4800P. Digital Real Time Recording VCR

WiFi Controlled Fused Spur Time Switch

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

Digital Real Time Recording VCR

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Operating instructions Electronic preset counter Type series 717

Schneider Industries SAS MTN5812../MTN MTN Time switch

USER & ENGINEER INSTRUCTION MANUAL

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

TDDFM14 OWNER S MANUAL

Tebis application software

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

EN Wireless programmable thermostat

Filter Control FS-201

DCP100 Digital Control Programmer Specifications

KNX Dimmer RGBW - User Manual

Comfort System T-32-P Universal Thermostat. Operation Manual

For installation queries contact Customer Services (0) TCR IP 4 Operating instructions

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Radio Thermostat Clock

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Preset counters, electronic

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Ambiflex MF620 USER GUIDE

Sevenlogic Comfort Timer Switch

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

Multifunction devices

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

New Times. AlphaRex 3 / MicroRex

Installation and Operation Manual. YMP Series Signal Programmer

Motion detector theluxa P300 KNX Motion detector theluxa P300 KNX

Hour Meters / Timers, electronic

ChannelPlus H17XL Series 2 User Operating Instructions

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Multifunction Digital Timer

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

Inserting the batteries. Basic settings of the remote control

Analog/digital watch Multi frequency reception, 4 digit LCD, 3 hands. Preliminary Specification

OPERATION AND MAINTENANCE

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

Flexible Counter Series in DIN size 24 x 48 mm

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

LARGE DIGITAL LED REAL TIME CLOCKS

Installation Instructions

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

Electrical connection

REMOTE DISPLAY WIRELESS DECODER MK II

Cronotermostato Digitale

Operations. BCU Operator Display BMTW-SVU02C-EN

UTH-170 Installation and Manual

SSPT724A Timer Quick Start Guide

21 Channel Light Show PWM LED Controller with Remote Control

Transcription:

SINGLE/TWO CHANNEL 24HR/7 DAY TIMER Cat No. TR671/TR672TOP INSTALLATION & OPERATING INSTRUCTIONS

TR671/TR672TOP 24Hr/7 Day 1/2 Channel Digital TOP Module (without Power Supply) Please read the instructions before using the product and retain for future use. The TR671/TR672TOP are electronic timer modules for OEM applications featuring Text Oriented Programming. Requires a 3V DC power supply. Please refer to www.theben.de/downloads/manuals/termina/ TR-671-672-top_GB.pdf for further information. 1 Overview per day of the programmed switching times 5 = Friday Channel statuses C1 or C2 are displayed alternatively ON/OFF Service voltage OK: Two flashing dots Power reserve mode: Three flashing dots Display of special functions: Hand ON/OFF Permanent ON/OFF Displayed only whensummer/ winter time changeover is activated Summer time Winter time Current days of the week 1 = Monday, 2 = Tuesday,... Selection e.g.: Auto, Prog,, Man, Abort Decision No means continue The decision Yes confirms the selection or programming

2 Description 1 or 2-channel digital time switch 42/28 memory locations with free formation of day blocks for both channels and separate programming of On and Off times. 32/21 memory locations with free formation of day blocks for both channels and separate programming of On and Off pulse switching times. Pulse length adjustable from 1-59 seconds. Or 16/10 memory locations for programming cyclic switching times on channel 1 or 2. Pulse and pause times can be adjusted from 1 second up to 99 minutes and 59 seconds Combination of cyclic switching, pulse switching and switching times possible Simple operation by means of integrated text line in the LCD display with only 4 keys Switching mode preselection for manual On and Off functions without influencing the automatic program sequence Switching status correction by subsequent review of inputs or changing the clock or switching time Continuous ON/OFF switching separate for each channel (maximum priority) Fully automatic summer/winter time changeover according to MEZ, GB, USA or freely programmable changeover regulation, can alternatively be disabled Power failure monitor to switch off switching outputs in case of a power failure. This is indicated by three flashing dots in the display Date-related vacation switching mode (OFF) to interrupt the automatic program separately for each channel Random function separately for each channel Backlighting Terminal Diagram Panel Cutout (Panel thickness 3mm Max.) R 0.5mm 45.5mm Block Diagram 39.5mm

3 First Contact 1. Activate with 3V DC: Select your National language and then enter the actual date and time. 2. Activate the clock, select the national language: By pressing the or key select your national language. Store your selection by pressing the key. 3. For programming, viewing or deleting: First of all read the text display. Menu selection: Select by pressing the Prog key. Confirm by pressing. By pressing the key select the desired menu e.g. New, View or Delete. Confirm your selection by pressing. Set or change: by pressing or. Store by presssing. To display the switching times: In the menu View, press the key several times. Selection of National Language Initial operation According to version According to version The decision Yes, confirms the selection or programming. The decision No, means continue. Set or amend by pressing the or keys. RESET (only in case of emergency): If you perform a RESET of the timer, the individual settings will be deleted. The programmes switching times remain intact. Press the RES key with a pointed object for approx. 1 second.

Specifications 4 Operating voltage VCC 3.0VDC ±10% NAK 3.0VDC ±10% Current consumption IVCC During operating processes appr. 700µA Automatic return to Auto mode after appr. 90 secs Auto-Mode appr. 25µA Additionally per actuated channel appr. 30µA Additionally with NAK=1 appr. 350µA INAK appr. 50µA Time basis Quartz 32768 Hz Accuracy < 1 Sec. per day at 20 C Shortest switching time 1 minute Switching precision accurate to the second Language group D - F - GB - I - E - NL Preset summer/winter time EU Configuration 1F 7D 40 2F Operating temperature -10 C... 65 C Switching output C1,C2 Open collector Off max. 55VDC at 0mA per channel On 0.2VDC at max. 4mA per channel ICmax 4mA Pmax 160mW at 20 C Connection 5-pole flexible lead, length appr. 125mm, without plug Backlighting: VLED+; VLED- IF appr. 14mA (max. 20mA at 25 C) UF appr. 8V (e.g. using series resistor) Connection 2-pole flexible lead, length appr. 90mm, without plug Switching mat Colour blue PANTONE 286C, Imprint black RAL 7035

Programming the Switching Time Switching times for lighting systems, machines, ventilation systems, alarm systems etc. Formation of day groups: If the same switching times are active on several days of the week, they occupy just one memory location 42 memory locations are available, e.g. Monday - Friday 7.30 hrs ON. Group formation: In answer to the text question Copy, decide by pressing the key that the day program should be copied to another day of the week. When programming an ON and OFF switching time, e.g. 9 AM, a switch-off at 9 AM always has priority. Program review: Following programming the timer makes a program review back to midnight and then sets the correct switching status. 5 Example: Example: Switching on the lighting of a sports hall on Mon., Tues., Thurs., Fri. from 7.30h until 12h. Programming example: Select PROG by pressing the key. Store your selection by pressing the key. Select NEW by pressing the or. Store your selection by pressing the key. Select channel C1 or C2 by pressing or. Store your selection by pressing. Select ON or OFF by pressing or. Set the hours and minutes by pressing the or key. Store selection by pressing. To store one day of the week only: Select weekday by pressing or. Select store by pressing. Store by pressing. To copy to other days of the week: Store COPY by pressing. Select weekday by pressing or. Store by pressing. To leave out a day of the week, skip by pressing the key. Finally select the STORE display by pressing. Store your selection by pressing.

6 Permanent ON or OFF Random or Holiday program Random ON Effect of the random program: The random program causes the timer to switch between programmed pairs of switches (ON and OFF). The random on an off times range between approx. 10 mins. and 120 min. The random time always begins with OFF. Symbol flashes when the random program is effective. Effect of the holiday program: The holiday program has the effect that the timer does not switch on the connected consumer unit between the programmed start and finish (stipulation of year, month, day). Start and finish of the program is always midnight on the day that is programmed. Example: 25.3. national holiday. Programming: start 25.3. finish 25.3. If the holiday program is active, the corresponding channel and holiday symbol are displayed flashing on the automatic menu. Read the text display first of all In the menu Man, select by pressing the or key the function manual, permanent, random or holiday. Confirm your selection by pressing the key. To cancel a function: Select the function clear. Store your selection by pressing. Example: Random start 19.30 h ON Random OFF Example: Random finish 6.00 h OFF Via the automatic menu Auto only Press the two keys for approx. 1 s. Manual preselection: Press keys simultaneously. Channel C1 or C2 switches alternately ON or OFF. Symbol appears. Manual preselection is corrected again by the stored program. Press both keys for approx. 2 s. Permanent ON OFF Cancellation of manual preselection/ permanent switching: Briefly press the keys shown above.

Pulse program e. g.: for breaktime signals, ventilation systems, flushing systems, bell controls etc. Effect of the pulse program: The pulse time can be set within the range 1 to 59 seconds. Symbol flashes as long as the pulse program is active. Switch-off delay Example: Switch off at 17.30 h 15 s Switch-on delay Example: Switch-on at 7.00 h 15 s 7 Program: 7.00 until 17.30 h and pulse at 17.30 h pulse ON, duration 15 s Program: To switch on from 7.00 until 17.30 h and pulse, OFF at 7.00 h pulse duration 15 s Day group formation If the same pulse switching times are effective on several days of the week, they occupy one pulse memory location only, e.g.: Mon., Tues.,Wed., Fri., pulse time 7.30 h. 32 memory locations are available for pulse programming. Viewing the pulse times Only possible in the menu PULSE. Always read the text display first of all. You will be provided with programming help. Confirm your selection by pressing the key.

Cycle program Cyclically recurring time functions within the scope of a timer, e.g. slow flashing indicator, water treatment, advertisement lighting Effect of the cycle program: The clocking and pause times can be set separately. The settable times are max. 99 minutes and 59 seconds. The cycle program has the effect that between two programmed times, day of week start and day of week finish, the cycle program is active. The cycle program always begins with a switch on. 16 memory locations are available to you. The symbol flashes when the cycle program is active. duration 8 Example cycle start: Monday 7.30 h ON pause Example cycle finish: Friday 16.30 h OFF Viewing the cycle times: Possible in the menu Cycle only! N.B.: If two cycle times are programmed in which the start and finish times overlap, it is always the cycle time that starts first that is executed. Example: Cycle time 1, programmed from: Mo to Thu Cycle time 2, programmed from: Tue to Fri. Only cycle time 1 is effective, cycle time 2 is not accepted. Brightness variations at lighting installations may arise in the cycling mode. In this case actions to reduce these effects have to be taken (for example reduction of the load or extension of the cycle time). More than five switching operations per minute are not admissible without additional EMC interference measures. Select by pressing the key Cycle. Store your selection by pressing the key. Set cycle start by pressing the keys or. Store your selection by pressing the key. Set cycle duration (Min./sec.) by pressing the keys or. Store your selection by pressing the key. Set cycle pause (Min./sec.) by pressing the keys or. Store your selection by pressing the key. Set cycle finish by pressing the keys or. Store your selection by pressing the key.

Setting/correcting the date and time summer/winter time Automatic summer/winter time correction According to version the timer is preprogrammed ex-works complete with the change-over. Should you switch off the automatic facility or wish to alter it, first of all read the text display. Select by pressing or. Store by pressing. Summer/winter time setting freely programmable. By entry of month and week e.g. Month 3 = March Week 4 = last week in the month Note: In sum/win free Prog the time change is set automatically at Sunday 2 AM. Time change is not available. 9 Read the text display first of all. Select by pressing the key or key. Store by pressing the key.

Individual deletions 10 Pin code The device can be locked against unauthorized use with a 4 digit code number. Select the Manual menu using or. Confirm with the button. Selection WITH PIN Select WITH PIN using or. Confirm with the button. Make note of any desired 4- digits number. Select the first digit of your 4 digit code using or. Confirm the entered digit with. Select further digits as described using or. Confirm each selected digit with the button. The device is locked 90 sec. after the last keystroke and can only be operated after the correct PIN code is entered. Selection WITHOUT PIN Select WITHOUT PIN using or. Confirm with the button. If a PIN code has been activated, the timer can no longer be activated without a valid PIN code after a RESET. The device must be sent in!

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. THREE YEAR 3 GUARANTEE HELPLINE 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com