Operators Manual. TeleWeigh Wired. Model: by Fairbanks Scales, Inc All rights reserved Revision 1 09/07

Similar documents
Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

OMEGA SERIES COUNTING SCALE

Weighing Scale. 10key&12key User manual

TABLE OF CONTENTS. Instructions:

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

COMPLETE MANUAL For Personal Scale AV-200-EC-P Baby Scale AV-20-EC Chair Weigher VEH-200-EC.

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

AS-300D Series Smart Bench Scales Owner s Manual

For warranty service, please contact Microframe at: A technician will gladly assist you.

Operating Instructions Rev. No. 4.1 July 07, LTC and VITC Reader with Serial Interface TC 60 RLV

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

10MHz Source/Inserter

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SCALE & WEIGHT DISPLAYS

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC)

HD1-LX HDMI & IR Extender

Extra long-range RFID (proximity) card reader

Noise Detector ND-1 Operating Manual

Instruction Manual Model BlockUpconverter

APSPB PUSH BUTTON ZERO Installation Manual

Twin Beam Scale Operation Manual. April Specialists in Industrial Weighing

16-BIT LOAD CELL/DUAL STATUS INPUT

Honeywell HomMed Wireless Scale Quick Reference Guide

Dystrybucja i sprzedaż: Meditronik Sp. z o.o Warszawa, ul. Wiertnicza 129, tel. (+48 22) , fax (+48 22)

VGA & RS232 Extender SET over Single CAT5 with RGB Delay Control

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

SDC-500 Digital Optical Chopper Operating Instructions

ASP-FIBRS1 User Manual

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

4X70 PROFINET SYSTEM

OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

NS-3 RF Noise Source Operation Manual

Model: UHD41-ARC. Installation Guide

3-in 1- out DVI Switcher

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Model 7000 Model 7000XL

VNS2200 Amplifier & Controller Installation Guide

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Service Manual. Eclipse Scale Series. Model: PPI-HR5000 HR by Fairbanks Scales Inc. All rights reserved. Issue #8 7/03

Sprite TL Quick Start Guide

2070 PROFINET MODULE

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

ST60-DVC VTR CONTROLLER ST60-AG57 VTR CONTROLLER

4X1 Gefen TV Switcher. GTV-HDMI N. User Manual

Model: HD41-ARC. Installation Guide

Model /29S RF Splitter

PulseFlow FP100 Pulse to 4 20mA Flow Converter (Flow Rate Transmitter / Totalizer / Indicator)

Instruction Manual Model # Block Upconverter

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

HD1-DX HDMI Extender

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LBC-HDBT LINK BRIDGE TM HDBASET HDMI TRANSMITTER SYSTEM

ET-REMOTE DISTANCE. Manual of ET-REMOTE DISTANCE

Instruction Manual Model Downconverter

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT. MATERIAL: White 16lb (60g/m sq), uncoated, prefer recycled stock Ink: Black

4X50 ETHERNET SYSTEM

Edition 1, August 2011 Copyright 2011 Smart-e (UK) Ltd.

2013, 2014 Hewlett-Packard Development Company, L.P.

4x4 Component Matrix over CAT-5

VGA Extender LR EXT-VGA-141LR. User s Manual

UV232A-4S & UV232A-8S 4 or 8 Channel Splitter PC Video, Audio & RS232 over Twisted-Pair

Telesto Private Wire Modem Manual

Service Manual. NexWeigh. Weight Instrument by Fairbanks Scales, Inc. Revision 3 03/10 All rights reserved

INSTRUCTION MANUAL. MODEL Downconverter

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual 1T-CT-630 Series HDMI to CAT.6 Extender System

LED-DEC W07 REMOTE DISPLAY WIRELESS DECODER

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

Userfriendly Guide. For use with BT s Caller Display and Call Waiting Select Services

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Applied Measurements Ltd

Single Station Waterproof Timer

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Model No. ST100 VTR CONTROLLER

Model No. ST60-S (-SRN, -SRK, -DRN, -DRK)

TV Lift System Model CL-65 Installation Instructions

FPV PRO RACE EDITION TRI-DIVERSITY VIDEO CONTROLLER

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

user guide SLX-111 also available: SLX-100, SLX-214 transmitter & receiver pair tel: +44 (0) ,

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

EGE-IR Bi-directional Infrared Matrix

T UNITS Appendix II Setup Functions PRINT FORMAT FORMATTING MINIMUM SAMPLE SIZE FORMATTING MINIMUM ACCURACY...

Model No. ST60-SPS (-SRN, -SRK, -DRN, -DRK)

Metal Electrode Meter

VXF7 QUICKSTART GUIDE. 7" 4K Full HD HDMI/3G-SDI On-Camera Monitor

Quick Start Guide. Handheld Transmitter HHa-941. Digital Hybrid Wireless US Patent 7,225,135

Modbus for SKF IMx and Analyst

3.5 TFT LCD CCTV Service Viewer with Wristband

LAUREL ELECTRONICS, INC.

DH5e-V2. Delta 5 On-Camera 4K HDMI Monitor with 3D LUTs. Quick Start Guide. What s Included

Troubleshooting CS800/LC900 Bikes

QCA9-33 Active Combiner

Transcription:

Operators Manual TeleWeigh Wired Model: 27707 2007 by Fairbanks Scales, Inc. 51164 All rights reserved Revision 1 09/07

Amendment Record TeleWeigh Wired Document 51164 Manufactured by Fairbanks Scales Inc. 821 Locust Kansas City, Missouri 64106 Created 01/2007 Revision 0 06/2007 Preliminary Release Revision 1 09/2007 Document Release 09/07 3 51164 Rev. 1

Disclaimer Every effort has been made to provide complete and accurate information in this manual. However, although this manual may include a specifically identified warranty notice for the product, Fairbanks Scales makes no representations or warranties with respect to the contents of this manual, and reserves the right to make changes to this manual without notice when and as improvements are made. It is the responsibility of the requesting party to develop, maintain, install, and connect networking devices and general network connectivity as it applies to the originating party s network. No warranty or guarantee, expressed or implied, concerning the network, its design, its installation, or operational characteristics has been offered by Fairbanks Scales. Fairbanks Scales shall not be liable for any loss, damage, cost of repairs, incidental or consequential damages of any kind, whether or not based on express or implied warranty, contract, negligence, or strict liability arising in connection with the design, development, installation, or use of an intended network. Copyright 2007 This document contains proprietary information protected by copyright. All rights are reserved; no part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without prior written permission of the manufacturer. 09/07 4 51164 Rev. 1

Table of Contents SECTION 1: GENERAL INFORMATION... 6 Scale Description... 6 Scale Specifications... 7 Environmental Characteristics... 8 Standard Approvals... 8 Display 8 SECTION 2: INSTALLATION... 9 Unpacking and Setup... 9 SECTION 3: OPERATIONS... 10 Manual Zero Operation... 10 Modes of Operation... 11 Stand Alone Weighing Operations... 11 Weighing with Bidirectional Telecommunications... 12 Inquiry Cycle... 13 Response Table... 13 Rules for Responses... 14 Stable Weighment Cycle TW mode... 14 Transmission Cycle... 14 SECTION 4: SERVICE & MAINTENANCE... 15 Scale Maintenance... 15 Installing Batteries... 15 Finding the Best Location... 15 Cleaning the Scale... 15 External Connections... 16 Troubleshooting... 16 Scale Error Codes... 16 LCD Display Indications... 17 Audible Beep errors/signals... 17 Load left on Scale Error... 17 09/07 5 51164 Rev. 1

Section 1: General Information Scale Description Fairbanks Scales TeleWeigh Health Scale is designed for weighing people and communicating that information to a variety of devices, via RS232 communications. The scale has its own calibration parameters and a display for showing measurements and audible alerts for signaling the user. The scale is capable of working in a Stand Alone mode or BT mode - connected to a device which is equipped for Bidirectional communications by connecting to a computer, or connected to another RS232 device. Battery powered or by connecting to a device through the RS232 cable. Uses (4) AA Alkaline batteries. The DC voltage required from the RS232 port is 8-12 volts. The scale is equipped with an RS232 Output, including an 8 foot cable. A USB interface is not provided. A optional USB to RS232 converter at the peripheral device would be required. Battery power for the scale is required using a USB to RS232 converter. 09/07 6 51164 Rev. 1

Section 1: General Information Scale Specifications Operating Environment Home, Office, Light Industrial Dimensions 14 x 14 x 2 Weight Capacity 500 lbs / 226.8 kg Overall Weight Less than 10 lbs. without batteries Power 6VDC (4 AA Alkaline) 12VDC via RS232 cable Autoswitching Cable Ports: RS232 Connection One (1) RS232 Bidirectional Output 9600 Baud 8-bit Data No Parity One (1) Stop Bit Eight (8) foot attached cable DB9 female external Internal RJ45 Connection (27706) 8-12 VDC Overload Protection 50% of rated capacity Annunciators Lbs Kg Ready / Stable Materials Rigid metal platform frame Composite base Power On Start Switch Integrated Composite top-over platform Division Size 0.5 lbs / 0.2 kg Mode Switch (Located on under-side) Lb Kg BT (Bidirectional Telecommunications) ignored in customized state Zero Switch Used to Zero the scale up to 100% of capacity 09/07 7 51164 Rev. 1

Section 1: General Information Scale Specifications continued Calibration Switch Momentary switch places the scale into the Calibration Mode Smart Switch Integrated ON switch The scale will turn OFF when a predetermined time length expires. Load cell Interface Utilizes (4) internal load Cells. No external load cell interface Filtering Three levels, adjusted using Remote Communications Environmental Characteristics ESD 8kv IEC 1000-4-2 standards Vibration Per ISTA QATR FP-1-011 standards Shock Per ISTA QATR FP-1-011 standards Standard Approvals RoHS Every attempt has been made selecting components which are Pb-free and/or RoHS Compliant Display Display Type LCD, 1.25 in. Seven (7) segment display No backlight 4-digits plus annunciators CZ Upper-left corner C used in Test Mode Gross, Tare Net Gross only Lb and Kg Small diamond indicates which unit of measure Ready Stable Small diamond indicates when scale is stable Low Battery Displays LbAt 09/07 8 51164 Rev. 1

Section 2: Installation Unpacking and Setup 1. Remove the scale from the packing box. 2. On the bottom-side of the scale, move the switch to the appropriate setting. lb (Pounds) is used for Standard English Weighments. kg (Kilogram) is used for Metric Weighments. BT (Bidirectional Telecommunications) is used for relaying the weighment from the scale to the computer to the professional office. 3. Place the scale on a flat surface where it will be used. 4. If the scale is used for Stand Alone operations, and not needing computer access, it is now ready for use. NOTE: For Stand Alone operations, the Mode switch will be in the lb or kg position. 5. If the scale needs computer access, with the computer powered down, plug the RS232 (DB9) cable into the computer port, then re-start the computer. The weights may be viewed by enabling the Serial port with HyperTerminal or software which is available from Fairbanks. NOTE: For computer access or BT operations, the Mode switch must be in the BT position. 09/07 9 51164 Rev. 1

Section 3: Operations Manual Zero Operation The scale may need to be manually zeroed occasionally. The following procedure will perform a manual zero of the scale. 1. While the display is still active (thirty seconds), press the Zero Button. using an item such as a straightened paper clip or toothpick. This is the top hole on the bottom of the scale near the Mode Switch. 2. Once the switch has been pressed, place the scale on a flat surface where it will be used. 3. The scale will set itself to zero (0.0) and be ready for use. 09/07 10 51164 Rev. 1

Section 3: Operations Modes of Operation The two basic modes of operation are Stand Alone Weighing Operations, and Weighing with Bidirectional Telecommunications. Stand Alone Weighing Operations Stand Alone Weighing Operations occur when the Mode switch is in the lb or kg position. It will also occur if the BT position is selected and the RS232 device does not communicate with the scale 1. On the bottom-side of the scale, move the switch to the one of these settings. lb (Pounds) is used for Avoirdupois Weighments. kg (Kilogram) is used for Metric Weighments. 2. Once the switch is selected, place the scale on a flat surface where it will be used. 3. Stand on the scale to momentarily to activate the scale and its display. 4. After its warm-up test, the scale should display zero (0.0) 5. Stand on the scale to obtain the weight. 6. Once the weight is stable, the scale will beep twice (2) indicating the weight has been captured 7. Step off the scale. The displayed weight is held on the display for about ten (10) seconds. 8. After the ten (10) seconds, the scale will briefly try to re-zero itself for the next weighment, provided there is less than ten (10) pounds on scale. 9. If a new weighment is not detected, the scale will automatically turn off after 30 seconds and the weighing process is complete.. 09/07 11 51164 Rev. 1

Section 3: Operations Weighing with Bidirectional Telecommunications Upon power-up, the scale transmits an ENQ 05hex character through the RS232 port, which allows a connected RS232 device to customize the scale. The connected device that handles the data is usually a computer. Regardless of the switch on the bottom-side (lb, kg or BT), the scale is in one of these two modes. This mode transmission depends upon whether or not there is a response after the ENQ message. If no response is received within five (5) seconds, the scale reverts to Stand Alone Weighing. If the scale is customized, on Power-up, the bottom-side mode switch is ignored. The last value for Units, Filter Factor, Output Rate and Transmission Mode is used 09/07 12 51164 Rev. 1

Section 3: Operations Inquiry Cycle 1. Upon a successful Power up Sequence, the scale will transmit an ENQ 05hex out of the RS232 port. 2. The scale will then wait five (5) seconds for a response. 3. If a response is returned, it will be acted upon per the Response Table below. Response Table Possible replies 0dhex = carriage return CAL DEF F# * M Or * TW, TP or TC * UL or UK * Z Scale action taken If the transmission mode is TP, transmit the current weight on the scale in the current units. There will be no ACK transmitted for this command but if the mode is not TP, a NAK will be transmitted. Weight string transmitted will be 11 characters <STX>PWWWWWUUS<ETX><CS> <STX> = 02hex = start of text P = Polarity WWWWW = weight string including decimal and leading spaces UU = units, either lb or kg S = stable weight reading, S for stable, U for unstable or motion on scale <ETX> = 03hex = end of text <CS> = Check Sum This string may also be <STX>LOW BATTERY<ETX><CS>, <STX>UNDERLOAD<ETX><CS> or <STX>OVERLOAD<ETX><CS> in an error condition. Enter calibration mode. Load default settings. Units = lbs, Filter factor = 2 = medium, Transmission mode = TW, output rate is slow or 500ms and the timer is reset.this takes the scale out of a customized state. Change to filter #, either 1, 2, or 3 where 1 = light, 2 = medium, 3 = heavy. Default will be 2 = medium. Transmit the current mode including units, filter setting and transmission mode. Example ULF3TW <CS> Output rate for TC/continuous mode. r is to be F for fast or S for slow. Fast = 200ms, slow = 500ms between outputs. Change to transmission mode indicated. TP and TC mode do not allow the scale to power down. -TW = Use the Stable Weighment Cycle (default or Stand Alone Weighing mode) -TP = Use a polled interface similar to the Ultegra using a Carriage Return. -TC = Continuously transmit the weight on the scale per the output rate setting. Change to units in response. Default will be lb. Zero the scale. 09/07 13 51164 Rev. 1

Section 3: Operations Inquiry Cycle, Continued Rules for Responses If a response is received, it will be processed and no weight will be transmitted (unless it is a CR and mode is TP). One response will be processed at a time. Responses may be received in any transmission mode. Changing from TP/TC Mode to TW Mode resets the 5 second timer so that other settings may be changed before a weight is transmitted. *Setting the filter factor, output rate, transmission mode or units through the serial port puts the scale in a customized state. In the customized state, the lb/kg/bt mode switch (located on the underside) is ignored on Power-up. The scale may be taken out of the customized state by reception of the DEF Command through the serial port or by using the spare switch. Stable Weighment Cycle TW mode After a successful Power up Sequence and Inquiry Cycle, the scale is in a Weighment Mode. The display shows either the current weight or 0.0. To preserve battery life, the user has thirty (30) seconds to step on the scale, After thirty (30) seconds, if no weight is detected or if the weight is unstable, the scale powers-down. If weight is detected and once the weight is stable, it is captured and displayed on the LCD. A dual audible beep indicates the end of the weighment cycle. In the event that the scale incurs an error condition, it is indicated on the display along with an audible alarm. Transmission Cycle The Transmission Cycle is the data transfer to a computer or other device, and then on to the Professional Office (if applicable). Only the weighment information is transmitted, which consists of the weight data and units. 09/07 14 51164 Rev. 1

Section 4: Service & Maintenance Scale Maintenance Installing Batteries 1. To install the four (4) AA Batteries, lift the compartment lid. 2. Match the correct poles and insert two batteries in one direction, then two in the other direction. 3. Replace the battery cover. Finding the Best Location Place the scale on a flat, solid, level floor, close enough to the computer that the cable is out of the way of regular operations. Keep the scale in a location completely away from all high water, such as lowlying areas that may flood or near any drain pipes. Cleaning the Scale Use a moist cotton cloth to clean the scale. If spray cleaner is needed for shoe sole marks, squirt it into the cloth, and not directly onto the scale. Use only tap water in the cloth to wipe off the scale s clear plastic display. 09/07 15 51164 Rev. 1

Section 4: Service & Maintenance External Connections 1. Plug display interface cable into the scale base where marked. 2. Plug the RS 232 interface cable into the computer, if required. Internal Connection RJ45 8-pin connector PCB J6 Wiring Wire Output 1 RX 2 TX 3 +12VDC 4 GND 8 Shield External Connection DB9 Female Wiring Wire Output 2 TX 3 RX 5 GND 9 +12VDC NC Shield Troubleshooting Scale Error Codes There are several error conditions and operational steps indicated by the scale. Not all are applicable in every sequence. Some errors are indicated using audible beeps and some are shown on the scale display. Listed below are the error conditions and their indication that have been defined to this point. 09/07 16 51164 Rev. 1

Section 4: Service & Maintenance LCD Display Indications Displayed Text or Enunciator All LCD Segments ON Motion/Stable Annunciator Lb Annunciator Kg Annunciator Description The scale is initializing its hardware Hardware test to check for a malfunctioning display. Scale battery requires changing Weight is stable on the scale Displayed weight is in pounds Displayed weight is in kilograms Weight Under Capacity Weight Over Capacity Calibration sequence successful Error in Calibration sequence Audible Beep errors/signals Number of Beeps Display message 1 or 2 Weight value and stable indicator on 7 Description Scale is ready for the weighment. Weight measurement is stable and captured. Short chirps at 5 second intervals for 30 seconds. Weight is left on scale, and On switch contact closed. Load left on Scale Error To preserve battery life, the Load Left On Scale error operation is implemented. This happens when the scale is turned on due to weight placement on the scale. The scale executes either Stand Alone Weighing or weighing the Bidirectional Telecommunications Cycle. After completion of either cycle, if a load is still sensed on the scale, it signals an alarm by chirping (short beeps) every five (5) seconds for a duration of thirty (30) seconds. This alarms users that there is weight on the scale, compromising the battery s life. 09/07 17 51164 Rev. 1

Manufactured by Fairbanks Scales, Inc. 821 Locust Kansas City, Missouri 64106 www.fairbanks.com TeleWeigh Wired Operator Manual Document 51164