Interface sheet - Edan ST-1212 Stress - CPET ergometer

Similar documents
Interface sheet - Nihon Kohden 1550K - CPET Treadmill

Interface sheet - Korr Cardio Coach Monitor - CPET Ergometer

RF Solution for LED Display Screen

Mortara X-Scribe Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

C Module Description

LA-1440 and LA-4440 Sound Level Meter

Audio Design Associates (ADA)

Library ebooks and Your Sony ereader

RDS: The RDS, or Radio Data System, is supported in the g! interface where available.

RADIO FREQUENCY SYSTEMS

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

GWL/ Power Group Technology Solutions Stay Powered for the Future

Cardioline Cube Stress Tango M2 Interface Notes

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

2x50 ETHERNET MODULE

DVB-T USB SET-TOP BOX

Any feature not specifically noted as supported is not supported.

Setup Guide. Pandora Pluto. Color Management System. Rev. 1.1

R4 AIS Class B Transponder

Artistic Licence Engineering Ltd Firmware Version V3.03 Manual Revision V1-9

Philips StressVue Tango M2 Interface Notes

Setup Guide. Quantum Data 70x/80x Series. Video Generators. Rev. 1.1

Yellow Frog. Manual Version 1.1

Setup Guide. Flanders Scientific BoxIO. Rev. 1.1

KRS-V7A Programming Software for the Kenwood TM-V7A

User guide. DVB-S/S2 module D. TRIAX - your ultimate connection. TRIAX - your ultimate connection

Configuration Vestas VMP3500

Manual PVA 4307, PVA 4310, PVA 4316 Video conferencing loudspeaker

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

application software

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

VSP 168HD Quick Start

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

Setting up the communication between a Total Station and SiteMaster range of products

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Setup Guide. Panasonic BT-4LH310. Rev. 1.1

DVB-LR10. Compatible with Land Rover touch-screen navigation systems version 2

Scan Converter Installation Guide

with the Field-IQ Crop Input Control System

YAMAHA 03D SERIAL AUDIO MIXER

EEG A1452 SCTE-104 Inserter Frame Card

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

48 TV Caller ID TV CALLER ID

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Cable Tester Automation by Christopher E. Strangio, CAMI Research Inc.

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

C8000. switch over & ducking

Getting Started With the imx Developer s Kit

TransitHound Cellphone Detector User Manual Version 1.3

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

FS3. Quick Start Guide. Overview. FS3 Control

2013, 2014 Hewlett-Packard Development Company, L.P.

Guide For Setting Up Your Fortec Lifetime Ultra Receiver

RL3-PCM41. Compatible with Porsche Panamera from MY 2017 with PCM4.1 infotainment and 12.3inch monitor

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Setup Guide. SpectraCal ColorBox. (also eecolor) Image Calibration Processor. Rev. 1.1

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great

Laboratory stand description. Investigation of DVB-T/C/IPTV technologies

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

Setting up your Roland V-Drums with Melodics.

HITS QT/QT+ Setup Instructions for QSD/QHD Services using: Drake SCT2x4 Headend Transcoder 2 Satellites/4 Multiplexes

Quick Guide Book of Sending and receiving card

VL2-PC-HSD. Compatible with Citroen and Peugeot vehicles with SMEG or SMEG+ navigation with 4pin HSD LVDS connector on the monitor

VSP 198CVS Quick Start

Auxiliary states devices

Setup Guide. Teradek COLR. Rev. 1.1

DBS Installation Guide

1 Synchronising Xsens with the Delsys Trigno EMG System

DT1-LR10. Compatible with Land Rover touch-screen navigation systems version 2

PT1500MX / PT1550MX PT1555MU / PT1505MU Touch Screen LCD Monitors

YAMAHA 03D SERIAL AUDIO MIXER

Weschler AMT Software for the Enhanced Version Transformer Advantage

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Audio Integration Note

WCS-D800 Programming Software for the Icom ID-800

DT1-LR. for Landrover touch-screen navigation systems version 1

SXGA096 DESIGN REFERENCE BOARD

HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L

C Module Description

Smart Com Remote Diagnostics Manual - Rev 6

HD-1600 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

Footnotes and Endnotes

42 Freestanding Infrared Multi Touch Screen Kiosk User s Manual

More Skills 14 Watch TV in Windows Media Center

Using SignalTap II in the Quartus II Software

VGA to Video Converter ID# 424 Operation Manual

RC1-G Series Controller

Setup Guide. EIZO Monitors. Rev. 1.4

VL2-PC-HSD and NAL-PC-HSD. Compatible with Citroen and Peugeot vehicles with SMEG or SMEG+ navigation with 4pin HSD LVDS connector on the monitor

TF5 / TF3 / TF1 DIGITAL MIXING CONSOLE. TF StageMix User's Guide

Burdick Quest Tango M2 Interface Notes

Setup Guide. Blackmagic Design HDLink Pro. Rev. 1.1

Transcription:

Interface sheet - Edan ST-1212 Stress - CPET ergometer Service documentation Lode BV Zernikepark 16 NL 9747 AN Groningen The Netherlands t: +31 50 571 28 11 f: +31 50 571 67 46 @: ask@lode.nl www.lode.nl

Table of contents 1 - List of symbols used 2 - Validity 3 - Setup instruction Edan ST-1212 Stress ECG 3.1 - Cable selection 3.2 - Software Setup 3.3 - Ergometer Setup 4 - Setting up the hardware 4.1 - Connection overview 4.2 - Connecting with the usb cable 4.3 - Connecting with the RS232 cable 5 - Treadmill or ergometer with 3.5" touch screen unit 6 - Treadmill or ergometer with 7" touch screen control unit 7 - Nummerical Control Unit - Treadmill only 8 - Treadmill or Bicycle without control unit 8.1 - Device without control unit 8.2 - Ergometer setup 3 3 4 4 4 5 6 6 7 7 8 13 17 19 19 22

1 - List of symbols used Next Previous 2 - Validity This interface form covers * All OEM treadmills manufactured by Lode B.V. with the part number 939900/01/02/07/08/09/10 starting from serial #939900-20090001; * All Katana treadmills 9349XX-201X0001 * All Valiant treadmills starting with serial number 932900-20122XXX and 9329XX-20121XXX * All Valiant 2 treadmill starting with serial number 9389xx-20140001 If your treadmill or ergometer is not covered by this interface form please contact Lode service service@lode.nl 3/23

3 - Setup instruction Edan ST-1212 Stress ECG 3.1 - Cable selection 1. Connect the ST-1212 STRESS ECG isolation box to a PC. Connect the isolation box to the ECG sampling box. You will need the RS-232 cable (part no. 930730) to establish communication between the Lode Corival Ergometer and the PC. The layout is as showed in the picture. 2. Connect the cable to the ergometer as described in chapter "Hardware setup". 3. Connect the RS232 cable to the ST-1212 STRESS ECG. 3.2 - Software Setup 1. Switch on the ST-1212 STRESS ECG and start ST-1212 program. 2. Select Devicetype/Protocol on the System Setup interface. 3. Select Ergometer in the Device Type pull-down list. 4. Select Ergoline in the Device Model pull-down list. 5. Select the COM port to which the ergometer is connected. 6. Press the OK key. ergometer. The system is now ready to communicate with the 4/23

3.3 - Ergometer Setup The following protocol needs to be set in the Lode ergometer to communicate with the external equipment. Bicycle ergometer: Ergoline P10 The next chapters describe the procedures to setup these protocols depending on the type of ergometer. 5/23

4 - Setting up the hardware Lode ergometers have two ways of connecting external devices. The cable selection depends on the connection possibilities of the external device. The previous chapter tells you which cable you need. This can be a RS232 cable or a USB cable. 4.1 - Connection overview Connect the cable to the USB port if you are using a USB cable. Please note that you may have to install the FTDI driver on the external equipment. This procedure is only needed if windows fails to instal the driver automatically. You can find the driver on the Lode website under the Services tab. Locations: - For the Treadmill the communication ports are Located on the front side near the power switch. - For the bicycle ergometer the communication ports are located on the bottom of the bicycle. Tilt the ergometer on it's side to be able to acces these ports. Communication Module: Use the single RS232 port to connect the communication module to the external equipment. Legacy communication card (picture above -> 1 * USB, 2 * RS232) In case you are using a RS232 cable you must use the RS232 port closest to the USB connector, on the picture indicated with RS232 (1). 6/23

4.2 - Connecting with the usb cable If there is no other connection available you can also use a USB cable to connect. 1. You will need an USB A to B cable (Lode part no. 930916) to establish communication between the Lode ergometer and your stress system or ergospirometrysystem. See picture left. 2. Connect the cable to the Lode ergometer. 3. Connect the cable to the external device. 4.3 - Connecting with the RS232 cable Connecting with the RS232 cable 1. Depending on the external device you may need to use a straight RS232 cable (Lode part no. 930911) or a cross linked cable. The cable selection chapter specifies which cable is needed. 2. Connect the cable to the Lode ergometer. 3. Connect the cable to the external device. 7/23

5 - Treadmill or ergometer with 3.5" touch screen unit Start the Lode ergometer. During start up information about the ergometer, like the kind of device, the serial number and the connected modules is displayed. After initialisation the terminal mode is automatically displayed. Swipe with your finger over the screen as indicated with the red arrow in the picture to go to the main menu. 8/23

Select "Settings" to change settings of the device. You can choose your Language in the "Language" menu. The menu "Sleep Mode" sets a screensaver. The menu "Terminal Settings" lets you set the communication settings for external communication. The menu "Service" is only intended for service purposes to be executed by factory trainend personel. Select "Terminal Settings" to change the communication protocol. 9/23

Select the Communication protocol as desribed in "Ergometer setup" chapter. Select "Default" for the baudrate. 10/23

Select "RS232" or "USB" depending in which cable you have connected to the Lode ergometer. Select the button with the house to go back to the main menu. 11/23

Select "Terminal" to set the ergometer in terminal mode. Your device is now ready for external control. 12/23

6 - Treadmill or ergometer with 7" touch screen control unit Start the device. Information about the device is shown on the display during boot mode. After boot up the device shows the Test window or main menu. To access the menu from the Test window you need to swipe the graph area of the touch screen as indicated in the picture. *Note that for this instruction the graphic view for a Lode Corival is used. The view for a treadmill might difer a bit but the procedure is the same. 13/23

Select "settings" to go to the settings menu. Scroll down using the red marked scroll button and select "Terminal". Select the communication protocol ad described in the "Ergometer setup" chapter. Use the scroll button to view the complete list. 14/23

Select "Default" for the baudrate. Select "RS232"or "USB" depending on the type of cable that you connected to the Lode ergometer. 15/23

Press the home button on the left bottom corner and select "Terminal". Your ergometer is now ready for external communication. on. It will boot directly into terminal mode. *optional* Your ergometer can be set to boot up in terminal mode. Follow these steps to activate this function: - Go to the settings menu - Select "Default Start Menu" - Select "Terminal" - Switch the ergometer off and 16/23

7 - Nummerical Control Unit - Treadmill only 1. Press and hold key #1 and #2 as shown on "Figure 1" for 10 seconds. 17/23

2. Press the enter key #4 until the display shows terminal 0 3. By using the "+" and "-" keys for the grade adjustment #3 you can change the "0" behind terminal to "1" to activate the Terminal mode. 4. Press enter #4 and "prot id" will be shown on the display, for Lode protocol this should be set to "1". Set the protocol as described in the "Ergometer setup" chapter. The following protocols can be selected Lode = Lode protocol track = Trackmaster communication protocol UUood = Woodway communication protocol HPcoS = HP Cosmos communication protocol ge = GE protocol 5. Press enter #4 and "baudrate" will be displayed to set the correct baudrate, select "0" for auto select. The following baudrates can be set: Baudrate = 0 (Autoselect dependent on protocol-id) 2400; 4800; 9600; 19200; 38400; 57600 6. Press enter #4 and "interface" will be displayed, you can choose the communication port which you would like to select. Interface = CIM interface choice. Select "RS232" or "USB" depending on the cable that you connected to the treadmill. 0 = RS232 1 = RS232-AUX 2 = USB 7. Press enter #4; the next step "Neg Elev" is read only and is "1" when a negative elevation option has been added to the treadmill, without a negative elevation option this value shows "0". Neg Elev = Negetive elevation (read-only) 0 = not present 1 = present Press the stop button #2 on the control unit or wait 10 seconds to leave the settings menu and let your changes take effect. 18/23

8 - Treadmill or Bicycle without control unit 8.1 - Device without control unit In case the device does not have a control unit the correct protocol can be set from a computer by using the Lode Service Manager tool that can be downloaded from the Lode website if you are a registered user. http://lode.nl/en/product/getdownload/469 Connect an USB cable from the computer to the USB port of the treadmill or use a RS232 cable from the computer to the RS232 port Start the Lode Service Manager and login with the same account details that you use to login on the website. 19/23

1. Select Terminal 2. Choose Setup to select the COM port on which the device is connected. 3. Select preset Lode Bus Service Protocol 4. Press OK 5. Press Break 6. Switch the device off, wait 10 seconds 7. Switch the device on The screen as shown left should show up within 5 seconds after powering up. 20/23

A menu is showed. use the nummerical keys to make your selection. The next menu will automatically come up when a number is pushed. Select settings (1) and choose the protocol as described in the "Ergometer set-up" chapter. Choose which port you want to use RS232 (0) or USB (1) This setting refers to the type of cable that you have connected to the Lode ergometer. Select default for the baudrate. Note that Default should always be selected unless different specified by your dealer. 21/23

Select the kmh/kmh (1) conversion for if you are using the Trackmaster protocol. If you are using a protocol other than Trackmaster select "no conversion" (0). Select "Disable" (0) for Global communication timeout. 8.2 - Ergometer setup The following protocol needs to be set in the Lode ergometer to communicate with the external equipment. Bicycle ergometer: Ergoline P10 The next chapters describe the procedures to setup these protocols depending on the type of ergometer. 22/23

Press "Y" to save the new settings and restart the device. Your device is now ready for use with the external controller. Note that the device is automatically switched to terminal mode when no manual controller is present at the device itself. 23/23