Sensopress LCD Special English

Similar documents
REGO Start&Go USER MANUAL

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LAUREL ELECTRONICS, INC.

Electronic converter for level transmitters MT03L Instructions manual

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

EXA PH200/400 and EXA PH202/402 Troubleshooting and Error Code Guide

SCALE & WEIGHT DISPLAYS

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Standard RS232 RS ma

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

MT03A Electronic converter for flow rate transmitters

K-BUS Dimmer Module User manual-ver. 1

AF-300 E11 Adjustable Frequency Drive

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

SY-MS121 SY-MS121-AP

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Henkel Installation Handbook LINEGUARD 2001

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

TABLE OF CONTENTS. Instructions:

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Process Transmitter RMA 422

All real signals have scale factor 10. Integer, Index and Logic has always scale factor 1.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Process transmitter RMA422

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Model IQ4-PC User Manual Revision Date:

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Digital Differential Pressure Gauge Switch 0.1 : 0.5 BAR USER GUIDE

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Hardware & software Specifications

STX Stairs lighting controller.

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Automatic Transfer Switch Control PLC Operator s Manual

Guided Wave Radar Level Meter

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

Technical data. General specifications. Indicators/operating means

Modular Lube Lubrication Systems System Controls

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Noise Detector ND-1 Operating Manual

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

ProVu PD6000 Process Meter

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Operation Manual TX20 1/8 DIN Microcomputer Based ph/orp Controller with relays

Standard signal metering in wall-mounting case

Transmitter Interface Program

DMP 331i / DMP 333i LMP 331 i

INSTRUCTIONS ASSEMBLAGE

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Digital Indicating ORP Meter AER-101-ORP. Instruction Manual

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

WELDING CONTROL UNIT: TE 450 USER MANUAL

ZIRCONIA OXYGEN ANALYZER CONVERTER

T775U Series 2000 Electronic Stand-Alone Controller

Level Measurement silometer FMC 420, FMC 423

Signet 2250 Hydrostatic Level Sensor

Operating instructions Electronic preset counter Type series 717

T775U Series 2000 Electronic Stand-Alone Controller

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

FLOW HUNTER II Open Channel Flow Meter Operation Manual

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

KNX Dimmer RGBW - User Manual

K3NX Process Meter OPERATION MANUAL

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Installation Guide. HDMI 4x1 Switcher

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

Wall-/Pipe-Mount Level Indicator

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

RF4432 wireless transceiver module

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

FLOMAT Electromagnetic Insertion Flowmeter

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

User Manual 19 LCD RP-919QD. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes.

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

Transcription:

Sensopress LCD Special English edition 2-09/2004 - code 5878 1/16

Sensopress LCD with sensor Power Supply Voltage 117 V~ 50 60 Hz 230V~ 50 60 Hz Code TSL00X0100 TSL00Y0100 Consumption 5,5 VA Display LCD 2x16 Operating Temperature 0 +50 C Storage Temperature -10 +60 C Operative Range -0.020 9 m H 2 O Max. Overpressure 20 m H 2 O Measurement Accuracy ± 1% FS Resolution 1 cm H 2 O Minimum obtainable Differential 2 cm H 2 O Output Relay 10A 250 V Available Channels n 1 Housing NORYL UL94V0 Dimensions mm 105x90x73 Weight gr. 450 Device + Sensor Weight Sensor Provided Sensor for Sensopress LCD Housing Stainless Stell(AISI 316) Brass Code PRS50B1A1M20000 PRS00B1A1M20000 Functioning Princple Ceramic Piezoresistive Capsule,calibrated and thermal compensated Dimensions mm 32x76 Weight gr 840 Cable PVC (2 Wires+ compensation tube) Cable Lenght Standard 20 meters Installation Submersible or External Operating Range 0 9 m H 2 O Max. Overpressure 20 m H 2 O Operating Temperature 0 50 C Power Supply Voltage 15 30 V 20mA max Output Current 4 20mA Rt=250 OHM max Stability +-0,3%f.s./year a 25 C Thermal Zero Shift Thermal Zero Span Notes +- 0,02%f.s: / C +-0,01%f.s./ C Can be used in all type of water with water ph between 5-9 For use in other kinds of liquids,contact the factory Sensopress is a high technology, electronic gauge and level regulator that can be used in sandy drinking water, in liquid food products, or with the help of adequate system solutions, in dirty and corrosive liquids. Measurements rely on a very sensitive pressure sensor, whose signal, transformed and processed by a microcontroller, is converted into "water column height" measured in centimeters. Note. In fact, all displayed values are in mbar. The correct value in cms of water can be obtained by increasing the pressure in mbar by 2 % (1.973 % at 4 C). edition 2-09/2004 - code 5878 2/16

FRONT PANEL of the Sensopress LCD Special The front panel of the Sensopress equipped comes with an LCD display, on which are visualized all the information relative to the device as well as three push buttons with which it is possible to interact and modify the parameters, establish the points of intervention at which to activate or deactivate a command relay of any kind of power equipment (pump, motor) or signal (lights, alarms etc...). The display of the device, when turned on, visualizes the name of the manufacturer, the version of the software and the name of the product: MAC3 V12 SENSORPRESS (FIG. 1) Fig.1 Sensopress presents seven functioning modes, in order: AUTO, LOW, HIGH, MANUAL, DISPLAY, PROTECT,CALIB. In the following table the name of the mode is indicated with its corresponding operation that is carried out: Modalità AUTO LOW HIGH MANUAL DISPLAY PROTECT CALIB Operazione eseguita Indicates: the level of water in the tank, high and low threshold Low threshold setting High threshold setting Manual setting of the eclectrovalve Regulator of the retroillumination of the display Insertion for the device protection Measurement of the water level scale. edition 2-09/2004 - code 5878 3/16

AUTO (fig.2) Relay position Auto mode Level measurement Low threshold High threshold Fig.2 After having turned on the device, the AUTO mode is the first to be visualized. The name of the mode (AUTO), the position of the relay (OFF O or ON ), the liquid level, measured in cm., in which the sensor is immersed (Lev:288 cm.), the low thereshold (Low: 027 ) and high threshold (High: 156) of the intervention established by the user. The buttons YES/+, NO/- are not in function. By pressing the button MENU on the display, the present mode and the request to transfer to another mode are indicated.(fig.3 Table 1) Present mode Request for transfert to another mode (table1) Fig. 3 Tab1e 1 Go to AUTO? Go to LOW? Go to HIGH? Go to MANUAL? Go to DISPLAY? Go to PROTECT? Go to CALIB? Once having picked out the mode that you wish to modify, by pressing the button YES/+you can access it. By pressing the button NO/- however, or by waiting about ten seconds, the device returns to the AUTO mode. edition 2-09/2004 - code 5878 4/16

SETTING THE HIGH AND LOW THRESHOLD Low Threshold, Low Mode ( fig. 4) Present mode High threshold Fig.4 Low threshold The LOW mode allows you to set the minimum point of intervention. On the display is shown the name of the mode (LOW), the present maximum threshold level defined by the user (HIGH:156 cm.) and the minimum threshold level to be set (LOW LEVEL: 031 cm.). By pushing the buttons YES/+, NO/- it's possible to increase or decrease the minimum threshold level desired. The minimum threshold level cannot excede the maximum level; if, by mistake, the minimum level should excede the high level, the value of the minimum threshold level will begin again from 000. With the button MENU the value inserted is memorized and the request to pass to a different mode is displayed on the front panel; if no button is pushed, the device returns to the AUTO mode after a few seconds. edition 2-09/2004 - code 5878 5/16

High Threshold, High Mode (fig. 5) Present mode Low threshold Fig.5 High Threshold The High mode allows you to set the maximum point of intervention. On the display is shown the name of the mode (HIGH), the present low threshold level (LOW: 031 cm) and the maximum level to be set (HIGH LEVEL: 156 cm.). By pressing the buttons YES/+, NO/- it's possible to increase or decrease the maximum threshold level desired; the maximum level must not be inferior to the minimum threshold level. If this level is reached, the device begins again from the point 899 cm.; with the MENU button the value that was inserted is memorized and the request to pass to a different mode is displayed on the front panel; if no button is pushed, the device returns to the AUTO mode after a few seconds. edition 2-09/2004 - code 5878 6/16

MANUAL SETTING MANUAL MODE (fig.6, fig.7) present mode Relay position OFF Fig.6 Request for transfert to relay ON Present mode Relay position ON Fig.7 Request for transfert to relay OFF On the display is shown the name of the mode (MANUAL) and the position of the relay (RELE: OFF, RELE: ON). In the MANUAL mode, by pushing the button YES/+, it's possible to intervene on the rele (relay), moving from ON to OFF and vice versa. The button NO/- is disabled. With the button MENU the request to pass to another mode is displayed. NOTE: Attention: in the MANUAL mode the device does not return to the AUTO mode. edition 2-09/2004 - code 5878 7/16

REGULATION DISPLAY DISPLAY mode (fig. 8) Present mode Retroillumination Turned ON Fig. 8 Present mode Power save mode Fig. 9 The DISPLAY mode allows you to control the state of the backlighting of the display. When turning on the device the backlighting is inserted and will turn itself off automatically after five minutes of non use. By pressing the YES/+ key, it s possible to set up the backlighting mode. By using the formulation in fig. 8, the backlighting is continuous, whereas when set up as in fig. 9, it is time scanned (an elapse of 5 min. from the last button pushed). The timer that reactivates the backlighting that is time scanned starts again by pushing any key. On the other hand, with the MENU key you pass to the request to change mode; if no key is pressed, the device returns to the AUTO mode. edition 2-09/2004 - code 5878 8/16

INSERTING THE PROTECTION SETTING Protection Mode (password: NO/-,YES/+,YES+,YES/+,NO/-) The password of the device is inserted at the factory and cannot be modified. In the PROTECT Mode there is the possibility of activating or deactivating the protection of the device in such a way as to impede non authorized personnel to modify the parameters; when the device is turned on the protection of the device is deactivated. On the display you will see shown PROTECT: DISABLED if the protection is deactivated, PROTECT: ENABLE if the protection is activated. To activate the protection it is necessary to: (fig. 10) Protection turned on Fig. 10 1. Enter PROTECT mode 2. Press the YES/+ key until the wording PROTECT: ENABLE appears(protection turned on) 3. Press MENU key to memorize Once the password has been activated, it will be requested every time you wish to change a parameter. To disable the protection proceed as follows: (fig. 11) Protection disabled Fig. 11 1. Return to the PROTECT mode 2. Enter the password pressing the YES/+,NO/- Keys in the following sequence: NO/-,YES/+, YES/+,YES/+, NO/-, 3. Press the YES/+ key until the word PROTECT:DISABLED appears (protection disabled) 4. Press Menu key to memorize edition 2-09/2004 - code 5878 9/16

PASSWORD entry Fig. 12 NOTE: If you decide to activate the protection device, to access each mode on the display the words ENTER-PASSWORD will be visualized (fig. 12), that is to say that a password made up of five characters will be requested to be introduced with the combination of the buttons YES/+ amd NO/-; if the combination is correct, you will be able to access that mode and thus, modify it; if the combination should result incorrect, you will not be able to effect any change. The password is inserted in the factory with the sequence NO/-, YES/+, YES/+, YES/+, NO/-. It can not be modified edition 2-09/2004 - code 5878 10/16

CALIBRATION OF THE LEVEL WATER SCALE: The instruments that leave the MAC3 plant are calibrated, that is to say that they are able to measure the water level in the field of measurement forseen and with the specifics indicated by MAC3. With this in mind, no intervention on the part of the user is required. For various reasons, such as the derating of the components, the substitution of the sensor, a variation in the position of the sensor, etc., the need to effect a new calibration may be necessary. This can be effected, upon request, by the MAC3 technicians. A useful alternative that can be used is an operation that is furnished with the device with just this purpose in mind, thanks to which the user can autonomously effect a calibration. You must have the possibility to subject the pressure sensor to two levels that are the most precise possible, as specified here as follows: CALIB In the CALIB mode, you can save the reading effected by the sensor subjected to zero level and subjected to the maximum level (can be selected between 100Cm and 900Cm). In this way, the reading results to be correct in the entire forseen field of measurement. When accessing this mode you have the visualizzation as seen in fig. 15. By pressing the MENU button it's possible to select one of the submenus as shown in fig. 15, 16, 17 passing ciclycally. Fig. 15 Fig. 16 Fig. 17 edition 2-09/2004 - code 5878 11/16

"SAVE PRESS ZERO" mode (fig. 15) Make certain that the sensor is subjected to the zero level. It's possible to save the reading of the sensor by pressing the YES/+ button.if the operation has been successful you should have the visualizzationas seen in fig. 18; otherwise you will have the visulizzation as seen in fig. 19: in the case of an unsuccessful attempt a default value is used. That assures an acceptable measurament bat obviously not as good as when the calibration has been sucessful The failure may be due to a real level that is not admissible as a zero level, or some anomaly in the subsystem that makes the pressure measurement. Fig. 18 Fig. 19 The "100cm 900 cm Y" mode (fig. 16 ) By pressing the YES/+ button, it is possible to select the maximum level at which the calibration is made, cyclically. When fig. 16 is visualized, the system is predisposed to save a value that it considers to be 900cm.. When fig. 20 is visualized, the system is predisposed to save a value that it considers to be 100cm.. In this case, by pushing the MENU button, it is possible to select one of the submenus shown in the fig. 15, 20, 21, by passing cyclically from one to the other. edition 2-09/2004 - code 5878 12/16

Fig. 20 Fig. 21 The " SAVE 900 cm." mode (fig. 17 ) or "SAVE 100 cm." mode (fig. 21 ) Make certain that the sensor is subjected to the level indicated (900cm. or 100 cm.). It's possible to save the reading of the sensor by pressing the YES/+ button. If the operation has been successful you will have a visualization as in fig. 22; on the contrary you will have a visualization as in fig. 23: in the case of a failure in the operation a default value is used. That assures an acceptable measurament bat obviously not as good as when the calibration has been successful. The failure may be due to a real level that is quite different from the one indicated, or due to some anomaly in the subsystem that makes the pressure measurement. Fig. 22 Fig. 23 With the NO/- button you can return to the AUTO mode; this takes place if no button is pushed. edition 2-09/2004 - code 5878 13/16

ELECTROMAGNETIC INTERFERENCES : If the device is placed in an environment where there is a lot of electromagnetic noise present, or if the contacts of the relay, supply some particular loads, the device may show some strange anomalies. The software is able to take measures to restore the correct functioning. In particular, in the AUTO mode, the display is reset at regular intervals of 9 seconds. This is the maximum duration of a written message deteriorated due to NOISE. In the case of particularly strong inductive loads, that is, when the disturbances are such that there are frequent anomalies, we suggest the use of a snubber circuit connected in parallel to the contact of the load. You make a snubber circuit by mounting a resistor in series to a condenser. Fig. 24 shows an example of the wiring diagram. Reccomended values: R1=47 Ohm ½ W, C1= polyester 0,1uF 250 Vac. Fig. 24 Power supply edition 2-09/2004 - code 5878 14/16

SERIAL CONNECTION (Optional) The Sensopress has the possibility of being connected to a computer by means of a serial port RS232; the data transmitted from the device can be visualized with the demonstrative software Sensopress LCD Special (fig. 13) which can be downloaded from the MAC3 website www.mac3.it Fig.13 It's also possible to use any communication software while keeping in mind the following parameters: Byte per second (bps) 300 Data bit 8 Parity none Stop bit 1 Flow control none RS232 standard connections DB9 Connectors Sensopress output 2 13 TX 5 15 GND Welding view edition 2-09/2004 - code 5878 15/16

ELECTRICAL DIAGRAM Sensor Power Supply edition 2-09/2004 - code 5878 16/16