Operating instructions Through-beam sensor. OJ51xx / / 2004

Similar documents
Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Operating instructions Capacitive level sensor KNQ

Cylindrical Photoelectric Sensor CY-100 SERIES

Photoelectrics Through-beam Type PA18C.T..., DC

QUICK START GUIDE FLEXSLICE MODULES

Electrical connection

Electrical connection

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Electrical connection

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Light Curtain Type LA

Amplifier for fiber optics. Dimensioned drawing

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Sensor technologies Proximity sensors Series ST4. Brochure

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Electrical connection

Hip Hop Activity Box. Instruction Manual. Hip Hop Activity Box 22875, October 2018 Copyright ROMPA Ltd

LUT Luminescence scanners: Seeing what no-one else can

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Solid-State Digital Timer

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Operating and indicating elements. 4 x LED green Lighting LED = power and

Electrical connection

Technical data. General specifications. Indicators/operating means

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Amplifier for fiber optics. Dimensioned drawing

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

SU17 Series Fiber Optic Sensors

10 PDUs 19 PDUs Zero-U PDUs

Operating instructions Flow monitor. SAxxx / / 2015

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Type F70AB F70ABPN. Digital display. Simple operation featured

D12 Expert Series TEACH-Mode Fiber Optic Sensors

SPACESCAN SERIES SS 02

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

Photoelectric Sensors E3F2

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Sensor technologies Distance measuring sensors Series SM6. Brochure

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Sound to Sight Showtime

Owner s Manual LED COMMANDER 16/2

MINI-BEAM Expert Series Installation Guide Microprocessor-based TEACH mode photoelectric sensors¹

Absolute Encoders Multiturn

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Spectra/Chrom Chart Recorder from Spectrum Chromatography

Projector Lift. User Guide INSTALLATION OPERATION SETUP PROGRAM IR REMOTE FACTORY RESET

F70series. Variation. Excellent detection performance

Site Installation Model MP-8424

First Steps TM Baby Walker

Multi-functional safety relay modules PROTECT SRB-E

Level Measurement silometer FMC 420, FMC 423

FB10000 Error Messages Troubleshooting

16 Amp Electronic 24 Hour/7 Day Time Controller

W100L: Laser Sensor in Mini- Format

V 180 Series Photoelectric Switches

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

W 9-2: A Versatile, Complete and Compact Series

TDEPD. Field-Programmable Pressure Switch/Transducer with Integrated LED Display. Programming Sequence Manual

Installation Instructions Series 9000 DeviceNett PHOTOSWITCHr Photoelectric Sensors

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

KNX Dimmer RGBW - User Manual

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Orbit TM DIGITAL SHAKERS

TABLE OF CONTENT. Designation code. Selection chart range. Functional description. Applications. Sensors. Product overview.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

DLP600M 6+1 Relay Module for Heating and Cooling Plants

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Safety Light Curtain C 4000

Be sure to check the camera is properly functioning, is properly positioned and securely mounted, every time you operate your vehicle.

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Light Emitting Diodes (LEDs)

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Site Installation Model MP-8433

ULTRASONIC. Distance and Proximity Sensors. UFP / UPA Series. Key-Features:

SA1J-F: Full Color Fiber Optic Sensors

45LM Series Modules. 45LM Series Description. Timing Logic Functions. LED Signal Strength Display Function. 45LM Series Modules Specifications

WF next: Fork sensors for a wide range of applications

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Product information. Front-door station series with video for surface-mount

XB-68 RF Detector & Camera Finder

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

DLP200M 2 Relay Module for Heating and Cooling Plants

Tailgate module BEXPRO PRINS VSI

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

Q3X Laser Contrast Sensor

Transcription:

Operating instructions Through-beam sensor OJ5xx UK 7098 / 0 07 / 004

Contents Function and features... Installation... Installation of the supplied mounting fixture...4 Electrical connection...4 Setting of the sensitivity with stationary objects*...5 Setting of the sensitivity with moving objects*...6 Setting of the maximum sensitivity*...7 Electronic lock...8 Programming the output function*...8 Operation...8 Maintenance...8

Function and features The through-beam sensor detects objects and materials without contact and indicates their presence by a switched signal. Range: see type label. Installation side sensing* front sensing* UK : : receiver transmitter receiver transmitter ED push button * In the following sections installation and set-up are described using the example of the type with front lens. The functions of the units with side lens are identical. Fix the receiver (type OJE-...) in position with a mounting fixture. Align the transmitter (type OJS-...) towards the receiver and tighten in the same way. Maximum range is only possible with precise alignment.

Installation of the supplied mounting fixture Secure the mounting fixture with the screws supplied, then slide the unit into the slot of the fixture until the spring clicks home. To remove the unit press the spring down with a screwdriver and slide the unit out. Electrical connection Isolate power Then connect the unit. Programming of the output function by push button or programming wire (see page 8). Receiver DC PNP 4 teach BN WH BK BU teach 4

Receiver DC NPN 4 teach Transmitter DC BN UK BU Core colours: BN = brown, BU = blue, BK = black, WH = white. Commissioning The through-beam sensor is supplied ready to operate (plug and play) set at the max. sensing range. This is sufficient if the through-beam sensor can operate with maximum excess gain (highest contrast). The following setting procedures should only be necessary in less straightforward applications, for example if partly transparent objects must be detected. Setting of the sensitivity with stationary objects* Activate the programming mode of the unit. Press for about s until the red ED flashes. The red ED goes out; the yellow and green EDs flash alternately. The unit is in the programming mode. Set the sensitivity with object. Press once The yellow and green EDs go out for approx. s, then flash again alternately. 5

Set the sensitivity without object. Press once The yellow and green EDs go out for approx. s. After approx s the green ED is on. The unit is in the operating mode. You can also proceed in reverse order: first setting without the object, then with the object. * The sensitivity can also be set in exactly the same way using the programming wire (pin / WH). To activate the functions the programming wire is connected for the appropriate time to (pin / BN) for PNP units or to - (pin / BU) for NPN units. Feedback: If setting was not successful via the programming wire, the output will switch for s. The unit then reverts to the operating mode with the sensitivity unchanged. If the setting of the sensitivity is not possible (e.g. object signal and background signal are about the same), the red ED flashes after step for approx. s. The unit then passes into the operating mode with the sensitivity being unchanged. If the setting button is not activated for 5 minutes during the programming process, the unit passes automatically into the operating mode with the sensitivity being unchanged. Setting of the sensitivity with moving objects* Activate the programming mode of the unit. Press for about s until the red ED flashes. The red ED goes out; the yellow and green EDs flash alternately. The unit is in the programming mode. 6

Allow objects to pass through the detection area during the measurement (about s) (number of the objects between min. 8 Hz and max. switching frequency). Press once. The yellow and green EDs go out for approx. s, then flash again alternately. Allow objects to pass through the detection area during the measurement (about s) (number of the objects between min. 8 Hz and max. switching frequency). UK Press once The yellow and green EDs go out for approx. s, after approx. s the green ED is on. The unit is in the operating mode. * The sensitivity can also be set in exactly the same way using the programming wire (pin / WH). To activate the functions the programming wire is connected for the appropriate time to (pin / BN) for PNP units or to - (pin / BU) for NPN units. Feedback: If setting was not successful via the programming wire, the output will switch for s. The unit then reverts to the operating mode with the sensitivity unchanged. If the setting of the sensitivity is not possible (e.g. object signal and background signal are about the same), the red ED flashes after step for approx. s. The unit then passes into the operating mode with the sensitivity being unchanged. If the setting button is not activated for 5 minutes during the programming process, the unit passes automatically into the operating mode with the sensitivity being unchanged. Setting of the maximum sensitivity* Go into the programming mode (step ). Interrupt the light beam. Press the setting button twice (see steps and ). * The maximum sensitivity can also be set in exactly the same way using the programming wire (pin / WH). To activate the functions the programming wire is connected for the appropriate time to (pin / BN) for PNP units or to - (pin / BU) for NPN units. 7

Electronic lock Activate the lock by connecting the programming wire for about 5 s 0 s*. Deactivate the lock by connecting the programming wire again for 5 s 0 s*. * To activate the functions the programming wire (pin / WH) is connected to (pin / BN) for PNP units or to - (pin / BU) for NPN units for the appropriate time. Programming the output function* Press for 0 s. The red ED starts to flash fast after s. Then the yellow and green EDs flash alternately. After 0 s all EDs go off, the output function has changed from light-on mode to dark-on mode (or vice versa). * The output function can be programmed in exactly the same way using the programming wire (pin / WH). To activate the functions the programming wire is connected for the appropriate time to (pin / BN) for PNP units or to - (pin / BU) for NPN units. Operation Check the safe functioning of the unit. Display by EDs. ED green is lit ED yellow is lit ED red is lit EDs yellow + red Unit is ready for operation. Output is switched. Error in object detection, e.g. maladjustment, soiling of the lenses. Flash alternately, Hz: output short-circuited. Flash alternately, Hz: internal malfunction (output is not switched). Maintenance Keep the lens of the sensor free from soiling. For cleaning do not use any solvents or cleaning agents which could damage the plastic lenses. 8