Tectiv 220 Instructions for use

Similar documents
System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Operating instructions III / 2004

Figure 1: Device components

LUNA 129 star-time

Operating Instructions Dimmer for V Incandescent Lamps

Luminaire installation box Surface-mounted box Ceiling installation box

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

Product information. Front-door station series with video for surface-mount

Digital Economy Seven Programmer

Modular pulse operated latching relay 16 A

Operating Instructions. Room temperature controller with clock

Operating Manual. Basic Control BC16. two-channel for eco moon

ST56(M)EL/ST80(M)EL-ETNS(B)

Digital Time Switch. Installation & Operating Instructions

Gamma instabus. Technical product information

STX Stairs lighting controller.

Operating instructions. Universal timer switch display

Installation Guide VL-MV10. Model No.

2 Hour Electronic Boost Timer

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Aspect 2 Circuit Digital Scene Control

SceneStyle2 User Guide

DLP200M 2 Relay Module for Heating and Cooling Plants

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Schneider Industries SAS MTN5812../MTN MTN Time switch

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

16 Amp Electronic 24 Hour/7 Day Time Controller

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Optical Signal Devices. Free-standing Beacons

INSTRUCTION & INSTALLATION GUIDE

Warner Photoscanner MCS-500 Series LED Photoelectric Control

7 Day Digital Time Switch

Emergency lighting units EM powerled

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

WiFi Controlled Fused Spur Time Switch

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

Documentation on all Paxton products can be found on our web site -

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

Re:source. Communication Module. SAT Version. Dominating Entertainment. Revox of Switzerland. E2.00

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Standard signal metering in wall-mounting case

Emergency lighting units EM powerled

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

TRF STEP-DOWN TRANSFORMER USER MANUAL

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

Operating Instructions

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

7 Lighting Technology

Dimming actuators GDA-4K KNX GDA-8K KNX

Bimetal Temperature Switch

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

RKSlimlift / EM. Two-stage lifting column

7 Day Digital Light Switch with Optional Dusk Start

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Tri-level Control HF Sensor

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

CAMTO LTD. Arc detecting system DC/AC

Filters for Power Lines (Low Leakage Current)

18W Low Energy Dusk-Dawn Bulkhead E-290B

IP Roombox. Hotel Room Management

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Benefits. Applications

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Operating instructions

Sensor technologies Proximity sensors Series ST4. Brochure

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

INSTALLATION & USER GUIDE

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

of Switzerland of Switzerland Re:source FM Tuner Module Dominating Entertainment. Revox of Switzerland.

MclNTOSH MODEL C-4 and C-4P

LUT Luminescence scanners: Seeing what no-one else can

Kuhnke Technical Data. Contact Details

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Mosaic TM Dimmer 3 x 1000 W

Telemetry Receiver Installation Guide

Professional-Practice

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

MKH 8060 Directional studio microphone


CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

e 935 Instruction manual Stage Microphones

LUXFLEX STANDARD THIN & FLEXIBLE BACKLIGHTING. Indoor Series

774 white matt 1789 TR black matt 1789 TR ) Surface painted.

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

e 604 Instruction manual Stage Microphones

Operating instructions Electronic preset counter Type series 717

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

XV-Z SharpVision 3D DLP Front Projector

ArteorTM Dimmer 3 x 1000 W / /60

10 SERIES. Light dependent relays A

LED MODULES READYLINE DL

INSTRUCTION MANUAL. Controller CLT-500 / RG-500

Azatrax Model Railroad Track Signal Control - Single Track

Transcription:

GB Tectiv 220 Instructions for use With teach-in: accepts the current brightness as an operating point with the press of a button.

1

On. Off. All by itself. The Gira Tectiv 220 reacts to movement. As soon as someone enters the detection area and the brightness of the surroundings have fallen below the set level, the light switches on. This is practical when you get home in the evening. And, of course, because it scares away undesired guests. If movement is no longer detected, the light turns off again. The operating time can be adjusted: from 1 second to 30 minutes. And if you want the Gira Tectiv 220 not to react for 2 hours, it can be set to be constantly on or constantly off. Even the operating point can be easily changed: when the desired level of light is reached, just press a button and the operating point is saved. With Gira, your house is more comfortable, secure, and economic. You can find out what else Gira offers as one of the leading manufacturers of modern electrical installation systems in a good electrical supply store or in the Internet at www.gira.de 3

With all comfort. Teach in - easily save the twilight value Caution! With teach-in, the controller for the brightness level can not be on minimum and the Tectiv 220 cannot be switched off or subjected to the influence of foreign light (e.g. light shining from a window). Wait for the desired level of light and then: 1. Turn the dome to the left and remove it. 2. Press the red Teach-button for at least 3 s (do not touch lens!).the LED will begin to blink. 3. Replace the dome and turn to the right. After 1 minute, the value is saved; the LED no longer blinks. If the light was already switched on, it goes off and only turns on again with movement. The current brightness value is saved. Deleting saved value: turn the brightness controller to the left until it stops, then turn it to the right to the desired value. The red LED blinks 3 times for confirmation. 4

Switching with the attached buttons For example, to turn the light on when guest are coming. Or to switch it on for 2 continuous hours on the veranda. Then, the normal monitoring function is active again. Buttons: Press 1x Light ON for set operating time. Press 2x continuous-on for 2 hours. Press 3x continuous-off for 2 hours. When the button is pressed again, the operating condition of continuous-on or continuous-off is cancelled again. 5

Assembly. The ideal place At a height of 2.4 m (optimum range). Perpendicular to the direction of travel (greatest sensitivity). Free of vibration and not directly over a lamp. Without shadows (walls, fences). Free from sources of disturbance (blank out bushes moved by the wind, streets that are heavily traveled, paths of pets). L external line Cable entry UP PE protective conductor N Neutral line Design-Ring (can be shifted 3 times, depending upon cable entry AP/UP) brightness (Teach-)button Sensitivity controller Brightness controller Operating time controller Switched Output Dome Cable entry AP Lens LED 6

Practical assembly Caution! Installation and assembly of electrical devices may only be carried out by an electrician. Switch the supply voltage off! Necessary screws, pins, and drilling template are included. 1. Drill according to the drilling template (Ø 6 mm). 2. Punch out cable entry (do not use a knife!). 3. Insert cable and screw on socket. TOP / OBEN must be on top with ceiling mounting in the direction of the area to be detected. 4. Electrical connection according to the diagram (see page 12/13). Do not place lines across terminals! Otherwise, the upper part can not engage. 5. With AP cable entry: Remove appropriate covers for the cable entry. 6. Put on upper part and engage audibly (guides!). 7. Turn the dome to the left and remove (bayonet). 8. Adjust lens, with ceiling mounting, pivot 90. 7

Adjustment and test. Adjustment, dimming, walking test 1. For the walking test, turn the brightness and operating time controller to T. The sensitivity controller cannot be set on min.. If the full range is not desired, grasp the lens by the lens bracket and tilt it down a little. If necessary, turn it to the side. Caution! Carry out the walking test with the dome removed. Check the detection area by pacing it off. With each detection, the LED will light up. If necessary, correct the alignment of the lens. 2. blank out sources of disturbance: To do this, mask off the appropriate segments on the lens with the matching segments of the included screen. If this is not enough, reduce the sensitivity with the controller. 3. Set operating time: 1 second to 30 minutes. 4. Set brightness: 3 to 1000 Lux or day operation. Recommended: 15 Lux (middle position of the brightness controller). Subsequent correction: see Teach-in (Teach-in of the brightness level is not possible during the walking test). 5. Attach dome and turn to the right until it stops (The Tectiv 220 can only be operated with a dome). 8

Data meant for an installation height of 2.4 m Classification of the segments Near Medium Far Background monitoring Near Medium Far Background monitoring Background monitoring Near approx. 0 to 3 m Middle approx. 3 to 9 Far approx. 9 to 16 m 16 m 24 m 9

Additional possibilities. Adjustment as a passage detector Operating time and sensitivity at min., brightness at max. With movement, the system is briefly switched on for 1 second and then switched off again (e.g. for a gong). After that, movement is not registered for 9 seconds. Switching the LED off and on The movement detection is signaled by the LED. This can be switched off or on again by pressing twice on the Teach-button, as needed. 10

Disassembly. Tools needed: screwdriver, tip width 4 mm. 1. Push design ring forward until it stops. 2. place the screwdriver in both holes ➀ ➁ (one after the other) and pry on the guides slightly in the direction of the design ring. 3. Pull off Tectiv 220 simultaneously with the lever movement ➂. 11

Connection diagrams. L N PE T L N Connection with buttons Press 1x: Light ON for set operating time. Press 2x: continuous-on for 2 hours. Press 3x: continuous-off for 2 hours. continuous-on / continuous- OFF returns to normal monitoring function after 2 hours. T = Button (opener) L N PE Reversing switches Replace existing reversing switches with buttons. Function as already described under Button. T L N T = Button (opener) T 12

L N PE T L N With 2 OFF switches With S1, the Tectiv 220 is deactivated and with the S2 the light is deactivated. During activation, the S1 is used for switching, not the S2. S1 S2 S = switch L N PE Parallel switching Parallel switching of several Gira Tectiv 220. T L N With the parallel switching the switching capacity is not increased. T = Button (opener) L N 13

Technical data. Nominal frontal range approx. 16 m (installation height 2.4 m) Nominal lateral range approx. 12 m (installation height 2.4 m) Detection area 220, can be reduced with screen Recommended assembly 2.4 m height Nominal voltage ~ 230 V, 50 Hz All-or-nothing relay 16 A Starting current up to 100 A Switching capacity filament lamps 2500 W HV halogen lamps 2500 W fluorescent lamps 1200 W Power input approx. 1 W (deactivated condition) Power input approx. 5 W (activated condition) Surrounding temperature -25 C to +55 C Make-time approx. 1 second up to 30 minutes Brightness detector 3 up to 1000 Lux and daily operation Additional functions passage detector, Teach-in, Light on, continuous-on/ continuous-off. Degree of protection IP 55 Connections L, N, PE, L(tm) 1.5 to 2.5 mm² Note: Take high peak inrush current under load into consideration! Not suitable for alarm systems because it is not secure against sabotage! 14

Manufacturer s guarantee. We guarantee our devices notwithstanding the claims of the final consumer toward the dealer resulting from the purchase contract as follows: 1. Our guarantee includes the correction or resupply of a device (according to our discretion) if the function of the device is limited or nonexistent due to proven material or manufacturing errors. 2. The claim deadline is oriented according to our generalterms of sales. Compliance with the claim deadline is to be demonstrated by voucher of the purchase date by means of an included invoice, delivery note, or similar documents. 3. The purchaser is definitely responsible for the costs of transport. Please send the device to our central customer service site postage-free with a description of the defect. Gira Giersiepen GmbH & Co. KG Service Center Dahlienstraße 12 D- 42477 Radevormwald The CE-mark is a unofficial market sign, which deals solely with the government body and includes no assurance of characteristics. 15

Gira Giersiepen GmbH & Co. KG Postfach 12 20 42461 Radevormwald Germany Telefon: 00 49 / 2195 / 602 0 Telefax: 00 49 / 2195 / 602 339 Internet: www.gira.de E-Mail: info@gira.de 4817 11 10 08/00