www.osram.com/prevaled PrevaLED Bar Preliminary Data sheet Benefits Dimension 280 x 55 x 6,3 mm (l x w x h) Designed for fixtures with round shapes Efficacy: Over 112 lm/w Consistent white light < 3 SDCM Modularity: 4 x 1000lm operated with OTp DALI 80/350 LS or 8 x 1000lm at OTp DALI 80/700 LS Application Office General illumination Technical operation data Product name Flux [lm] @ Tc 45 C* CCT [K] Typ. CRI SDCM Module P [W] Module [lm/w] @ Tc 45C L80 B50 [h] @ Tc 45 C** LEP1000830B 1 1000 3000 85 < 3 10.2 101 60,000 LEP1000840B 1 1000 4000 85 < 3 9.4 112 60,000 Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. * Tolerance for optical and electrical data: /10% **average Lifetime L80B50 (lumen maintenance) only Attention: due to NONSELV Concept the Light Engines has to be protected against physical contact in operation Technical Features Dimension (l x w): 280 x 55 mm Lumen package: 1000lm Color temperature 3000K and 4000K 32 LED per single module 1000lm Wire connection module to ECG & module to module Various fixation (M3 and M4 screw) possibilities enable good thermal contact Operation by dedicated OTp DALI 80/350 LS or OTp DALI 80/700 LS 1 target values PrevaLED Bar, January 2013 page 1 of 6
Minimum and Maximum Ratings Product Storage temperature [ C ] Tc max.* (@ typ. current) L80 B50 @ Tc max. 75 C LEP1000830B 20 85 75 C 45,000 h LEP1000840B 20 85 75 C 45,000 h The modules are designed for operation with OTp OPTOTRONIC ECG. *) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the light engine. The temperature of the LED module must be measured at the tcpoint according to EN605981 in thermally settled conditions with a temperature sensor. For exact location of the Tc point see drawing below. Luminous Flux over T c 106% 104% Phiv / Phiv Tc 35 C 102% 100% 98% 96% 94% 20 25 30 35 40 45 50 55 60 65 70 Tp / C valid for specified typical current Product name Typ. Current Typ. Forward Voltage LEP1000830B 108 ma 94 V LEP1000840B 100 ma 94 V Location of T c point T c T c point is located at the bottom side on the right of the module and marked with T c. PrevaLED Bar, January 2013 page 2 of 6
Average Lifetime (lumen maintenance) over Tc (case temperature) valid for specified typical current 80000 70000 Average Lifetime (h) 60000 50000 40000 30000 L80B50 20000 20 25 30 35 40 45 50 55 60 65 70 75 80 Tc ( C) Estimated average lifetime versus case temperature (indication only) Cable For connecting the module OSRAM recommend to use an AWG 20 (0.5mm²) solid wire cable, typical diameter for cable inclusive insulation ~2mm. Electrical Connection On module level String configuration 1 x 32 LED s for 1000lm PrevaLED Bar, January 2013 page 3 of 6
Wiring of ECG and modules ECG module module module module Example for 4 modules Current & Power for different parallel module configuration LEP1000830B LEP1000840B Number of modules Current Power* Current Power* 2 216 ma 20.4 W 200 ma 18.8 W 3 324 ma 30.6 W 300 ma 28.2 W 4 432 ma 40.8 W 400 ma 37.6 W 5 540 ma** 51.0 W** 500 ma** 47.0 W** 6 648 ma** 61.2 W** 600 ma** 56.4 W** 7 756 ma** 71.4 W** 700 ma** 65.8 W** 8 864 ma 81.6 W 800 ma 75.2 W * Electrical Power of modules @ Tc 45 C ** Target configuration with upcoming brightness bin PrevaLED Bar, January 2013 page 4 of 6
Drawings LEP10008x0B PokeIn Connector All dimensions: General tolerances: mm /0.15 if not specified PrevaLED Bar, January 2013 page 5 of 6
Safety Information The LED module itself and all its components must not be mechanically stressed. When handling the module without use of mountain screws avoid excessive force on the cover as it may be separated from the PCB. The integrated mounting and locking mechanism on the cover of the module is intended to center and lock a reflector. Excessive force on this mechanism may cause permanent damage to the module. The modules are intended for operation only with matching OPTOTRONIC of OTp series. To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 61347213, EN 55015, IEC 61547 and IEC 6100032 ENEC: 61347213 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. Please see the relevant brochure for more detailed information (see "Related and Further Information") OSRAM OPTOTRONIC electronic control gear complies to all relevant standards and guarantees safe operation. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Pay attention to standard ESD precautions when installing the module. Important information on photobiological safety is available in the application guide. Ordering codes Product group Product name EAN * SUnit * PrevaLED Bar LEP1000830B 4008321 852335 8 PrevaLED Bar LEP1000840B 4008321 852359 8 OPTOTRONIC OTp DALI 80/220240/350 LS 4008321 824882 25 OPTOTRONIC OTp DALI 80/220240/700 LS 4008321 824905 25 *) EAN: Ordering number per single module SUnit: Modules per shipping unit Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves. Assembly Information For optimum cooling a thermally conducting layer should be applied between module and heat sink. Further details and recommendation for mounting can be found in the application guide. Sales and Technical Support OSRAM GmbH Hellabrunner Strasse 1 D 81536 München Deutschland www.osram.com 49 89 62130 Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all OSRAM subsidiaries are listed with complete address and phone numbers. Related and Further Information PrevaLED Application Guide www.osram.com/prevaledlinear OPTOTRONIC Technical Guide www.osram.com/ecgdownloads OPTOTRONIC Data Sheets http://catalog.myosram.com PrevaLED Bar, January 2013 page 6 of 6