TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

Similar documents
TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

TORK MODEL DWZ100A 1 CHANNEL DIGITAL TIME SWITCH

TORK MODEL DZM200A 2 CHANNEL DIGITAL TIME SWITCH WITH MOMENTARY CONTACT

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

TDDFM14 OWNER S MANUAL

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Overview: Specifications: Installation Instructions:

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

SSPT724A Timer Quick Start Guide

Installation and Operation Manual. YMP Series Signal Programmer

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

Junior Max (JR Max ) Controller

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

User s Guide. ECx Features: Automatic Sprinkler System Timer

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

User s Guide. ECx Features: Automatic Sprinkler System Timer

Schneider Industries SAS MTN5812../MTN MTN Time switch

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

16 Amp Electronic 24 Hour/7 Day Time Controller

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Battery Operated Controllers

7 Day Digital Programmer 3 Channel Surface Mount

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

LCS-2. Low Voltage Lighting Control Relay Processing Panel. Operator s Manual

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

Radio Thermostat Clock

EasilyExpandable Up To 12 Stations. With 2-Station Plug-In Modules 3 Watering Programs With: GreenKeeper 212 Features:

Innovative Air Systems ABN When Calling For Support Quote:.doc

Master Time Clock MTC Users Manual

7 Day Digital Time Switch

PQ-Box 100 Quick Start Instructions

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Installation & Programming Manual. Please read before using this timer.

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

XTM72E & F Real-Time Clock Modules

Digital Time Switch. Installation & Operating Instructions

Digital Economy Seven Programmer

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

Movement Caliber Cal.5030D

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

Single Station Waterproof Timer

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

QUARTZ TIME RECORDER. Simplex 300 OPERATION MANUAL

GAUGEMASTER PRODIGY EXPRESS

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

EN Wireless programmable thermostat

1. General Information:

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

INSTALLATION, PROGRAMMING AND OPERATION MANUAL

Conference Speaker Timing System. Operating Instruction Manual

Electronic 2-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

DMX-LINK QUICK OPERATION

XTM72 Exerciser Timer Module

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

Single Axis Position Controller

Operating Manual. Basic Control BC16. two-channel for eco moon

Jamar Smart Hand Dynamometer

7 Day Digital Light Switch with Optional Dusk Start

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

1 Channel Multi-Purpose Programmer User Instructions

Programmable Room Thermostat With RF

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Movement Caliber Cal.Z60

Electronic Timer Control Day Astronomic Electronic Control

How do I delete a. Remove Here

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

[I] SELECTING ACTUAL TIME. )lf~ IMPORTANT: INSTALLER, Please leave this guide with the householder together with its Warranty card.

Master Clock Controller. User Guide. pyramidtimesystems.com

Simply clever! The digital DIN-rail time switches by Grässlin

Master Clock Controller. User Guide. pyramidtimesystems.com

) AMANO. ,i CINCINNATI ELECTRONIC TIME RECORDER EX 6000 SERIES

24Hour/7Day Electronic Timeswitch

Master Clock Controller. User Guide. pyramidtimesystems.com

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

PERFECT Operating Manual

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

INSTALLATION and OPERATING INSTRUCTIONS

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Sport-TIMER 3000 TM Instruction Manual

Users Manual. Models 96954, 96956, 96874, PN ra. dimensions: flat: w: 14" h: 5" finished: w: 7" d: " h: 5" proof no: 2. date:

Transcription:

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT FEATURES Single channel signal timer with 2 duration settings 288 signals in 5 minute increments 24 Hour scheduling with day omitting Battery back-up uses standard 9 volt non-rechargeable (not supplied). Lithium averages 450 hours of power outage; Alkaline averages 175 hours Manual activation or deactivation of signal Automatic daylight saving - user selectable Automatic leap year compensation AM/PM or 24 hour format - user selectable INSTALLATION UNIT IS TO BE INSTALLED BY A LICENSED ELECTRICIAN 1. To remove unit from enclosure: Push tab on right to swing unit to the left and remove. 2. Mount the enclosure at eye level using screws or other suitable fastening device. Bring supply and load wires in through bottom or side knockouts. DO NOT USE TOP. Input wires to controller must be dedicated i.e. no other loads connected to the same circuit. 3. Install a standard 9 volt lithium or alkaline battery (not supplied) by gently squeezing the right side of the battery cover on the front of the unit and pull to open. Pull out the battery connector and connect the battery. Reinstall battery cover. Lithium should be replaced every 3-5 years, Alkaline every year.

NOTE: Unit can be fully programmed using battery power only. 4. Reinstall unit by reversing step #1 above and connect wires to unit as per suggested wiring diagrams. See illustration on enclosure label. KEY FUNCTIONS DAY MONTH HOUR DATE MIN YEAR OVER- RIDE MODE SP DAY SIG SEC ENTER DAY/MONTH: Press to advance the day in the CLK and SKIP modes. Press to advance the month in the DATE mode. HOUR/DATE: Press to set the Hours in the CLK mode and in the Schedule SET mode. Press to advance date in the DATE mode. MIN/YEAR: Press to set the Minute in the CLK mode and in the schedule SET mode. Press to advance Year in the DATE mode. OVERRIDE: Press to execute or terminate a signal. MODE: Press to advance to next mode without affecting the display information. Sequence is: RUN, CLK, DATE, schedule SET, SIG 1, SIG 2, Skip (SP). In the SET mode, unit automatically reverts to the RUN mode if no entries are made for a short period of time. SP DAY: Press to set or delete SKIP days (those on which no signal schedule is executed) SIG/SEC: Press to select signal 1, signal 2, or no event - or to set the duration of signals in seconds. ENTER: Press to store the displayed information into memory. Information will not be stored until ENTER is pressed. NOTE: During settings, each press of the key will advance one number. For rapid advance, hold key in. 2

SETTING THE UNIT SELECT AM/PM OR 24 HOUR MILITARY FORMAT Upon powering up the unit, model number 180S appears on the screen. The LCD will next display 12H which is an automatic (AM/PM) format. Press ENTER to keep AM/PM format or press HOUR key to alter 24 hour (Military) format and then press ENTER. Once the ENTER is pressed, unit goes to RUN mode You can recognize that the unit is in the RUN mode when the real time (including seconds) is displayed. SU AM OFF NOTE: Once you select and ENTER the above format (either AM/PM or 24 hour military), you can not alter it without removing all power to the unit by disconnecting the battery and line power. 3

TO SET CLOCK Press MODE key; display shows CLK. SU AM CLK Press DAY/MONTH key to select today s day. Press HOUR key to set present hour (check AM/PM). Press MIN key to set present minutes. Press ENTER key. Unit now stores present time. Seconds are set at zero. DAYLIGHT SAVING The user may select either standard U.S. option or no daylight saving at all. 1. U.S. OPTION: Daylight saving is automatically set when entering the current month/date/year. The unit will add one hour on the first Sunday in April, and subtract one hour on the last Sunday in October. You never need to look up the tables, or enter the spring and fall correction dates yourself. 2. NO DAYLIGHT SAVING: The unit will not be configured for daylight saving time correction by not entering the month/date/year. TO SET DATE NOTE: ENTER ONLY IF AUTOMATIC DAYLIGHT SAVING IS DESIRED. IF NOT REQUIRED, DO NOT SET DATE. INSTEAD, SKIP THE FOLLOWING SECTION AND PRESS MODE KEY UNTIL DIS- PLAY SHOWS SET. 4

Press mode key until display shows DATE. DATE Press MONTH key to select month. Press DATE key to set today s date. Press YEAR key to set present year. Press ENTER key. Unit now stores present date. Note: If unit has correct entry for the calendar, then the unit will go into the SET mode. If the calendar has an incorrect entry, then the unit will stay in the DATE mode, with MM--YY displayed, signifying that the date does not correspond with the month, and/or year, i.e. Feb. 31,1996. If this occurs, set the correct date, and then press ENTER. TO SET SCHEDULE For convenience, write out your desired schedule on a separate piece of paper. If display does not show SET then press MODE key until display shows SET. The display will show 12:00 AM. AM SET 1. Press HOUR key to set hour (check AM/PM) 2. Press MIN key to set minutes Note: Minutes advance in intervals of 5 because scheduling execution has 5 minute resolution. 5

3. Press SlG/SEC key to set signal 1 or signal 2. (Actual duration of signals will be set later.) 4. Press ENTER key to store the signal event. REPEAT ABOVE STEPS FOR ALL DESIRED SIG- NAL EVENTS Note: After each event is entered, the clock (in the set mode only) automatically advances 5 minutes. 5. Press MODE key to return to RUN mode. TO SET SIGNAL DURATIONS 1. Press MODE key until display shows SIG 1 and 00. 2. Press SIG/SEC key to set duration time in seconds (1-99). 3. Press ENTER key to store the information. Display now shows SIG 2. 4. Again press SIG/SEC key to set duration time in seconds (1-99). Press ENTER key. TO SET SKIP DAYS 1. Press MODE key until display shows SP 2. Press DAY/MONTH key and SU starts flashing. 3. If you want Sunday to be a skip day, press SP DAY key and SU will remain solid. Next day (MO) will begin flashing. If you do not want Sunday to be a skip day, press DAY/MONTH key to advance to the first desired Skip Day. Then press SP DAY key. 4. If you want to delete a previously set skip day, press DAY/MONTH key to advance to that day - then (when Flashing) Press SP DAY key to delete it. Summary: SP DAY key sets a flashing day as a SKIP day and also eliminates a constantly displayed day from Skip day status. DAY/MONTH key advances the days. 6

5. When all selected skip days are displayed as constant. Press ENTER key. Unit goes to run mode and clock shows real time. Skip day(s) will flash when its day of the week is reached. 6. To skip schedules on all days (such as for vacation shut-down) press the SP DAY key when unit is in the run mode. Current day of the week will flash and a D will appear in the upper right display. To resume normal schedule, press SP DAY key again. REVIEW/MODIFY SCHEDULE: 1. Press MODE key until display shows SET. The first chronological event will be displayed. 2. Press ENTER repeatedly to continue reviewing the other scheduled events. After all are displayed, unit will show 12:00 AM and new entries may be made. 3. To modify an event, press mode key until display shows SET. Then press ENTER key until the scheduled event is displayed. Then press the SlG/SEC key to change to SIG 1, SIG 2, or blank which indicates delete entirely. PRESS ENTER KEY AFTER EACH MODIFICATION. SKIP DAYS: Press Mode key until display shows SP. All of the skip days are displayed as solid. To modify, use DAY/MONTH and SP DAY keys. (See section TO SET SKIP DAYS ). OVERRIDE: Override can only be executed when unit is in the run mode and is accomplished by pressing the OVER- RIDE key. When pressed, duration time of signal 1 will be executed. If no specific duration had been set for signal 1, then it will sound for 1 second. If either signal 1 or signal 2 are in progress when OVERRIDE key is pressed, then the signal will be terminated. 7 MLI-91(A) TORK 1 GROVE STREET, MT. VERNON, NY 10550 TEL: 914-664-3542 FAX: 914-664-5052