DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

Similar documents
DATA SHEET ML210 ML210_IT_EN_DS017REV12_IS

FLOMAT Electromagnetic Insertion Flowmeter

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Mechanical flow switch for On/Off control

Single Point Flow Monitor SW118 SW119

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

TFRH Hygienic RTD temperature sensor. CombiTemp TM

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Bimetal Temperature Switch

Pressure transmitter COMPACT IO-Link,

Selection matrix for electronic pressure switches

Inductive sensor NI3-EG08K-Y1-H1341

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Unipole and Multipole Connectors

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

PROPORTIONAL VALVES Sentronic plus

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

Inductive sensor NI10-M18-Y1X-H1141

Fiber Optic Splice Closure GPJ Instruction Manual

2.9 Sigma/ 2 Plunger Metering Pumps

Sensor technologies Proximity sensors Series ST4. Brochure

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SECTION 4 TABLE OF CONTENTS

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

GRUNDFOS alldos product information. The solution for complex dosing tasks

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

Capacitive sensor BCT5-S18-UP6X2T-H1151

Type D mechanical diaphragm

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO


DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Hygrotest 600. Instruction manual WH / WHT -20/+70 C DH / DHT -20/+70 C / DHT -20/+120 C PHT -20/+70 C / PHT -20/+120 C

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Welding equipment for the POLYSTIC system

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2)

mass flow meter for Gases

DMP 331i / DMP 333i LMP 331 i

Series SM ø12 mm. Inductive Position Transducer. ranges mm. linearity 0,2/0,3% ø12 mm, clamp-ø8 mm h6. out: AC, V, V, 4...

KVT Split cable glands

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

IMPAC Infrared Thermometers

Signet 2250 Hydrostatic Level Sensor

OPERATIONS MANUAL. ba76140e01 02/2013 CONDUCTIVITY CELL FOR ULTRAPURE WATER

Inductive sensor BI1.5-EG08K-Y1

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Installation instructions Cable transit device Roxtec RS ES Ex

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

lumenalpha spot Specification Sheet

Filters for Power Lines (Low Leakage Current)

Swiveling unit. Smooth and precise swiveling

NEW SWIVELING UNIT RSP-FLEX. Smooth and precise swiveling

ENC - LKE51 - L I B

KVT Split cable glands

Size B INDUSTRIAL STANDARD

Gear Pump Units For single-line centralized lubrication systems

WLS27 Multicolor LED Strip Light with EZ-STATUS

The full range of performance

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Flexible. Fast. Precise. PPU-E Pick & Place Unit

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Inductive sensor With analog output BI15-M30-LI-EXI

Photoelectrics Through-beam Type PA18C.T..., DC

2291 Guided Wave Radar Level Transmitter

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Level Measurement Point level measurement RF Capacitance switches

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

Model # of Colors Colors Input Connection 1 K90TLGRPQ 2 Green, Red K90TLGYRPQ 3 Green, Red, Yellow K90TLBGYRPQ 4 Blue, Green, Yellow, Red

EZ-STATUS WLS28-2 Multicolor LED Strip Light

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

COMPONENTS & COMPONENTS & ACCESSORIES

Level Measurement Point level measurement - RF Capacitance switches

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

General Specifications

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

LPUM - Local Power Unit General. Product Data Sheet January 2013 SD E06

TUC: Universal thermostat

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

EXPlora. Introduction

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Transcription:

DATA SHEET MS 3780

INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 OPTIONAL FEATURES 2 TECHNICAL DATA 2 OVERALL DIMENSIONS 3 LAYOUT 4 INSTALLATION 5 INSTALLATION RECOMMENDATIONS 6 SENSOR GROUNDING 7 SENSOR VERSIONS / JUNCTIONS BOX 8 SEPARATE VERSION 9 ACCURACY TABLE 10 HOW TO ORDER 11

1 di 13

TECHNICAL DATA Size for pipe line Ø OVERALL FEATURES Size 1 Ø 500mm Size 2 Ø 1000mm Size 3 Ø 2000mm Minimum conductivity Humidity Range Accuracy CE Certification 5 µs/cm 0 100% (IP 67) See relevant converter data sheet Yes STANDARD FEATURES Body material Nominal pressure Process connection Version protection rating Lining material/gasket Liquid temperature Electrodes material Size for pipe line Ø Nominal pressure Process connection Electrodes material Version protection rating Stainless steel AISI316 1600 kpa 1 Threaded end Compact IP67 PEEK/FPM -20 C 100 C compact version -20 C 130 C separate version Hastelloy C276 OPTIONAL FEATURES (CHECK FOR MORE DETAILS HOW TO ORDER ON LAST PAGE) Other on request Others on request Others on request Others on request Separate version (max 20m) IP 68 Separate version (max 500 m), with preamplifier IP 67 (OPT. IP 68) 2 di 13

OVERALL DIMENSIONS 82 L 104 60 1" 118 3 di 13

LAYOUT 1 2 3 4 5 POS. 1 SCREW M6x16 2 GROWER Ø6 DESCRIPTION 3 JUCTION BOX COVER 4 O-RING 4400 5 SCREW M4x6 6 PCB FOR SEPARATE VERSION (NORMAL OR PREAMPLIFIER) 7 JUCTION BOX MAIN HOUSING 8 CABLEGLANDE PG9 9 O-RING 155 10 SCREW M5x10 11 GROWER Ø5 12 SENSOR MS3770 6 7 9 10 11 8 2 1 13 GASKET PTFE 12 13 4 di 13

INSTALLATION - Cut the Ø 1" jacket as in picture 1 (dimensions in pic. 6) - ATTENTION: consider the necessary over-metal for the welding operation (pic. 2) - Align longitudinally the connector box with the pipe line axis (pic. 5) - Tighten the nut with a spanner keeping the alignment (pic. 4). The fixing of the nut must guarantee the sealing of the gasket Z=L-S-1/8D-32 Spanner40mm Pic. 1 Z - weld the jacket to the pipe line Flow direction 2,0 Recommended operative dimensions for 1" screw 1 Gas Seals side 2,5min. 20,0 Pic. 2 - Place gasket into the sensor - Insert the sensor into the Ø 1" nipple Over-metal Jacket Pipe SIZE SIZE 1 SIZE 2 Pic. 4 Pic. 5 DN RANGE DN 80 up to DN 500 DN 80 up to DN 1000 L 176 244 SIZE 3 DN 80 up to DN 2000 462 Sensor L Sensor installed Gasket 1 jacket Pipe line Pic. 3 D (internal) 1/8D S Pic. 6 5 di 13

INSTALLATION RECOMMENDATIONS In vertical installations an ascending flow is preferable. For vertical installations with descending flow direction contact the manufacturer Avoid a partially empty pipe, during operation the pipe must be either completely full of liquid or completely empty Install the sensor away from bends and hydraulic accessories MOUNT VALLEY DN See table 5 DN Install the sensor away from bends and hydraulic accessories DN Disturbance upstream from the measuring point Min upstream straight length expressed in multiples of pipe diameter. Table according data from UNI10727_1998 Valid for a measurement at the point of mean axial velocity Valid for a measurement on the axis of the pipe 90 elbow or a t-bend 50 25 Several 90 coplanar bends 50 25 Several 90 non- coplanar bends 80 50 Total angle convergent 18 to 36 30 10 Total angle divergent 14 to 28 55 25 Fully opened butterfly valve 45 25 Fully opened plug valve 30 15 6 di 13

SENSOR GROUNDING For the correct operation of the meter the sensor and liquid must be equipotential. ALWAYS connect sensor and converter to the ground. For grounding with a cathodic protection pipe, please contact the manufacturer. 7 di 13

SENSOR VERSIONS / JUNCTIONS BOX 1 2 3 4 A PAINTED ALUMINIUM B AISI 304 PRICE LIST OPTIONS A B G A-4 F A-3 JUNCTION BOX TYPE (surface finish) Without junction box, converter connected on the connections box A-1 A-2 only for ML110 N Q U S T P R K Y W V J A-2 with preamplifer A-4 with preamplifer B-1 (raw) B-2 only for ML110 (raw) B-4 (raw) B-3 (raw) B-2 with preamplifer (raw) B-4 with preamplifer (raw) B-1 (polished) B-2 only for ML110 (polished) B-4 (polished) B-3 (polished) B-2 with preamplifer (polished) B-4 con preamplificatore (finitura lucidata) 8 di 13

SEPARATE VERSION Conductivity (µs/cm) 200 150 100 50 ML145/255 SP/SL MV110 ML110 ML210 5 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Cable lenght (m) Note: It is recommended to install the connection cables away from, or protect against sources of electromagnetic noise. The minimum conductivity of the liquid medium to ensure correct functionality of the empty pipe detection is 20 µs/cm 9 di 13

ACCURACY TABLE e % 0,1 m/s 0,33 ft/sec 0,5 m/s 1,64 ft/sec 5,0 m/s 16,4 ft/sec 10,0 m/s 32,8 ft/sec speed 0,4 m/s (1,2 ft/s) e = +/- A % (reading value) speed < 0,4 m/s (1,2 ft/s) e = +/- (B/V) % (reading value) minimum flow (l/s): DN x DN x 0,008/1000( DN expressed in mm ) where: e = ACCURACY V = WORKING SPEED (A and B values: see below table according to CONVERTER model) SPEED A B (Speed m/s) B (Speed ft/s) 2 0,8 0,24 Reference conditions: Constant flow rate during the test Pressure: >30 kpa Flow condition : fully developed flow profile Zero stability +/- 0,005 % ID accuracy: mean value better than 1%, IDmin/IDmax>0,98 10 di 13

HOW TO ORDER MS 3780 code 1 Suitable for piping diameter 1 Suitable for diameter < / = 500 mm. 2 Suitable for diameter < / = 1000 mm. 3 Suitable for diameter < / = 2000 mm. 9 Suitable for diameter: to be specified Sensor and electrodes material / lining A A Sensor material AISI316, Peek lining, electrodes in Hastelloy C276, gasket in FKM, NEK in SS AISI 304 Z Connection type 1 Sensor material: to be specified 1 1" female threaded connection 0 Connection: to be specified Number and electrodes material A A B G F N Q U S T P R K Y W V J Compact version, IP67 protection rate Separate version, Painted Aluminum JB, protection rate IP68, standing immersion with 1,5 m of head water - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, Painted Aluminum JB, N 1 connectors IP 68 suitable for fast cable connections - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, Painted Aluminum JB, N 2 connectors IP 68 suitable for fast cable connections - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, Painted Aluminum JB, PREAMPLIFIER*, protection rate IP67 - (DEFINE THE CABLE LENGTH MAX 500 m-add THE COST ) Separate version, Painted Aluminum JB, PREAMPLIFIER*, N 1 connectors IP 68 suitable for fast cable connection - (DEFINE THE CABLE LENGTH MAX 500 m-add THE COST ) Separate version, AISI 304 JB RAW, protection rate IP68, standing immersion with 1,5 m of head water - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, AISI 304 JB RAW, with N 1 connectors IP 68 suitable for fast cable connections - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, AISI 304 JB RAW, N 2 connectors IP 68 suitable for fast cable connections - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, AISI 304 JB RAW, PREAMPLIFIER*, protection rate IP67 - (DEFINE THE CABLE LENGTH MAX 500 m-add THE COST ) Separate version, AISI 304 JB RAW, PREAMPLIFIER* N 1 connectors IP 68 suitable for fast cable connections to - (DEFINE THE CABLE LENGTH MAX 500 m-add THE COST ) Separate version, AISI 304 JB POLISHED, protection rate IP68, standing immersion with 1,5 m of head water - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, AISI 304 JB POLISHED, with N 1 connectors IP 68 suitable for fast cable connections - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, AISI 304 JB POLISHED, N 2 connectors IP 68 suitable for fast cable connections - (DEFINE THE CABLE LENGTH - ADD THE COST ) Separate version, AISI 304 JB POLISHED, PREAMPLIFIER*, protection rate IP67 - (DEFINE THE CABLE LENGTH MAX 500 m-add THE COST ) Separate version, AISI 304 JB POLISHED, PREAMPLIFIER* N 1 connectors IP 68 suitable for fast cable connections to - (DEFINE THE CABLE LENGTH MAX 500 m-add THE COST ) MS3780-1A1A (Example of Complete code for order) 11 di 13

12 di 13

ISOIL INDUSTRIA S.p.A. HEAD OFFICE SERVICE Via Fratelli Gracchi, 27 isomagservice@isoil.it 20092 Cinisello Balsamo (MI) Tel +39 02 66027.1 Fax +39 02 6123202 vendite@isoil.it If you want to find the complete list of our distributors access at the following link: http://www.isoil.com/u_vendita.asp If you want to find the complete list of our distributors access at the following link: http://www.isoil.com/u_vendita.asp BEFORE returning any material, please contact our SERVICE at the e-mail adress: isomagservice@isoil.com Due to the constant technical development and improvement of its products, the manufacturer reserves the right to make changes and/or modify the information contained in this document without notice. AZIENDA CON SISTEMA DI GESTIONE QUALITA CERTIFICATO DA DNV GL