Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Similar documents
Küba comfort DP. Draught-free ventilation and extremely quiet operation

Just cool with green: GEA Küba market SP. The new standard for basic refrigeration applications

Küba Blue Line Aircoolers Küba SG commercial

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Connectivity accessories by Nestor Cables

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

Product Data Sheet 4650 N-465

Forced Convection Laboratory Ovens

Immersion Pumps HCT (High Chem) sealless

SPECIFICATION. Spec No : VSS-1402-CS603B

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

STB Distribution Box Screw or IDC Type Indoor DP Outdoor DP Wall & Pole DP Pillar DP

Ultra Quiet Series Electric Air Handler

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Split System Air Conditioner

CME500 SERVICE PARTS

Magnetic Stirrers Magnetic Stirr

Product Data Sheet 8506 VW-691

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

CONCRETE CONSOLIDATION

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Product Data Sheet 4656 EZ

Contents. Introduction. Quality. Introduction. Introduction 2

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

Product Data Sheet 4656 ZW

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Model KBF 1020 Constant climate chambers with large temperature / humidity range

ULTRALOW TEMPERATURE FREEZERS -86 C

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

Tile saws - Masonry saws - Block saws

Type D mechanical diaphragm

Model KBF 115 Constant climate chambers with large temperature / humidity range

ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

PROCESS HEAT. From LE to LHS: How to benefit from Leister s new generation of air heaters. We know how.

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Agilent High Capacity RV Pumps & Roots Pumping Systems

Safe Enclosure Cooling

Air Conditioning Components and Equipments for Enclosures

SoliTherm. Control Cabinet Air Conditioning....wegweisend innovativ

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Air cooled Outdoor installation R-410A Hermetic Scroll Ice protection system FREE-COOLING HydroPack ECOBreeze Electronic expansion valve

TUC: Universal thermostat

istep STEPPER MOTOR PUMP

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

Series 8800 Radial Tip Fans Design 8812

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

3M Sensored Termination (15 kv) QX-T15I-vi1-E

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

Inter-Temp. Medium Profile Unit Cooler Publication No December, Medium to Large Walk Ins. Cooler & Freezer Applications

MIKRO POWER FACTOR CORRECTION COMPONENTS

Type: DILM25 10(24V50HZ) Article No.:

An impressive appearance

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Product catalogue 2010

POWER LINE BAR SERIES DA PL6 WW NORA

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

POWER MOLE SERIES DA GAO RGBT RADIX


POWER FACTOR CORRECTION

Type: DILM12 10(24VDC) Article No.:

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Dry Compressing Vacuum Pumps. Dry Com. CLAWVAC Claw Vacuum and Overpressure Pumps

MVSI-TS. Technical features

Roof-mounted Blue e+ cooling unit Integration solution VX25

DM 50 / DM / 2- component dosing and mixing system. engineering

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Immersion Pumps HCT (High Chem) sealless EN

Air Conditioners. CR Compact, Mid-Size and Full-Size Air Conditioners and Accessories

Series description: Wilo-Sub TWU 3 HS

15.0 Overview Cross Connection Cabinet KVS Overview Polyester Production Cross Connection Cabinet Unicab Vario 8

Features. Specifications. Finish. Notes

The supreme discipline

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED

Customised complete installations Series 400 Compact, ecological and economic. Polydos 460

M A R I N E B R I G H T S O L U T I O N S

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

Panel-Mounted Thermostat

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

VarioSynergic 3400 / 4000 / 5000 VarioSynergic / / MIG/MAG welding PERFECT WELDING

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Bimetal Temperature Switch

SR Series. Spring Return dosing pump D - mechanical diaphragm. The right dosing choice

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Air Flow Static Pressure Characteristics MU1238A MU1238B MU1238L. Static Pressure. Static Pressure. Speed [r/min] [Pa] Speed

Model ED 23 Drying and heating chambers Classic.Line with natural convection

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Transcription:

The space-saving helper in filling stations, gastronomy and the trade

The space-saving helper in the positive and negative range Straightforward mounting Integrated air baffle plate Extremely space-saving Type designation code 1 2 3 4 5 6 DF B E 07 1 D 1 Model range designation 2 Fin spacing 3 Electric defrost 4 Size 5 Number of fans 6 Generation Code [ 2 ]

Capacity range (for SC2) 1.5 kw 10 kw Content Application benefits for contractors and operators... 4 Basic version... 6 Temperature range (t L1 ) Technical data DFA (E)... 8-25 C 0 C +20 C Technical data DFB (E)... 8 Dimensions, weights, electric defrost, drain... 9 Number of fans to Variants... 10 Accessories... 11 [ 3 ]

Applications Supermarkets Canteen kitchens Working / server areas Küba compact DF Application benefits for contractors and operators Apart from fruit, vegetables and dairy products, packaged deep frozen products have for many years also been standard fare for the retail food trade. It is imperative that the cooling chain and required temperature are maintained uninterrupted in storage. The size of the store and type of stored goods are decisive in the selection of air coolers. Discounter stores are characterised by high turnover of goods and storage times as short as 1-3 days. The frequency at which stores are accessed for removal and storage of goods is correspondingly high. The cooling power of the evaporator must be dimensioned correspondingly, ensuring that the indoor temperature distribution remains constant. The Küba compact DF (especially for small rooms) is optimal for these applications. The compact evaporator has the necessary cooling power to ensure the uniform distribution of air, thereby ensuring that the room temperature is maintained in all corners of the cold room. [ 4 ] Küba compact DF Küba Green Line

from the Küba Green Line production range Maximum hygiene in the cold room, optimal protection of the goods The Küba compact DF air cooler is deployed with an important objective in mind: to keep goods in the cold room fresh in an hygienic environment. The gastronomy cooling specialist compact DF therefore ensures that conditions are optimal right from the start hygiene and protection of produce are writ large: Fast, reliable and simple with the folding and removable parts of the housing. Unsurpassed compactness 315 mm Küba compact DF air coolers do their name proud. They are compact power packages. The compact DF has reliable built-in Küba temperature control in the positive and negative range to ensure reliable cooling performance with optimal utilisation of space. Best air guidance through built-in air baffle The integrated air baffle guides the cold air to the ceiling of the cold room and thereby far into the room. This even distribution of cold air ensures that the stored goods retain their natural appearance and their taste. Retention of their full value is therefore ensured. Küba compact DF Küba Green Line [ 5 ]

Basic version Casing Aluminium, Sendzimir zinc-plated steel, smooth High-grade powder coating RAL 9018 papyrus white Food-safe Easy to clean Best quality powder coated edges Drip tray can be folded down and unclipped Double drip tray Compact design Heat exchanger for direct expansion Heat exchanger with staggered tube system consisting of special copper tubes, drawn oxygen-free and inner finned according to DIN EN 12735-1,2 with 12 mm diameter and closed, pure-aluminum HFE fins Internal cleanliness according to DIN 8964 Fin spacing: A = 4.5 mm B = 7 mm Fins flared to form-fit the core tube Highly effective heat transfer and compact design Tubing: Cu-Special Fins: Aluminium End plates: Aluminium DFA: Flow distributor, with multiple injection DFB: Küba-CAL refrigerant distributor with multiple injection Electric defrost Heaters with CrNi steel sleeve Vapour-tight connections Mains voltage: 230 V-1/400V-3-Y Wired ready to connect in junction boxes Optimized tubular heater configurations ensure fast and even defrosting Fins flared to form-fit the core tube Aluminium heat pipes that ensure excellent heat transfer to the fins and thus effective defrosting cycles with optimized service life. [ 6 ] Küba compact DF Küba Green Line

Fans Available fan diameter: 300 mm Permissible motor ambient temperatures: -30 C bis +60 C 230 ±10% V-1~, 50 Hz/60 Hz With built-in protector, according to VDE provisions Fans are wired to an internal distribution box Protection class: IP44 Insulation class: B Operating values are the values of the built-in motor at +20 C, with an unobstructed air flow and a dry surface Controller: Phase control Transformer Delta/star Frequency converter Please observe the manufacturer s information! Motor label data * Type 50 Hz 60 Hz Ø mm rpm W A rpm W A DF 051-074 D 300 1,350 70 0.32 1,500 90 0.40 Motor data per fan * Data provided by the manufacturer Küba compact DF Küba Green Line [ 7 ]

Technical data DFA (E) A 4,5 mm Type Rating Q 0 at 50 Hz. DT1. R404 A Cooling surface Air flow Air throw Tube volume Connections Sound Fans (Operational values at 50 Hz) Standard condition SC1 SC2 *** Inlet Outlet L WA Blade Current Per Fan kw kw m 2 m 3 / h m dm 3 Ø mm Ø mm db (A) Ø mm 230 ± 10% V-1 50 Hz rpm W A 1 2 3 4 DFA 051 D 2.6 1.8 6.9 950 9 1.4 10 x1.0* 12 x1.0 68 300 230 V -1 1,350 75 0.35 DFA 061 D 3.1 2.0 8.3 1,100 11 1.7 10 x1.0* 12 x1.0 68 300 230 V -1 1,350 75 0.35 DFA 071 D 3.7 2.4 12.3 1,035 11 2.5 10 x1.0* 18 x1.0 68 300 230 V -1 1,350 75 0.35 DFA 052 D 5.1 3.4 13.8 1,900 11 2.7 10 x1.0* 18 x1.0 71 300 230 V -1 1,350 75 0.35 DFA 062 D 6.3 4.1 16.6 2,200 13 3.2 12 x1.0** 22 x1.0 71 300 230 V -1 1,350 75 0.35 DFA 072 D 7.4 4.7 24.7 2,070 13 4.8 12 x1.0** 22 x1.0 71 300 230 V -1 1,350 75 0.35 DFA 063 D 9.4 5.9 24.9 3,300 15 4.8 12 x1.0** 22 x1.0 73 300 230 V -1 1,350 75 0.35 DFA 073 D 11.1 7.1 37.0 3,105 15 7.1 12 x1.0** 28 x1.5 73 300 230 V -1 1,350 75 0.35 DFA 064 D 12.6 8.0 33.2 4,400 18 6.3 12 x1.0** 28 x1.5 74 300 230 V -1 1,350 75 0.35 DFA 074 D 14.9 9.8 49.4 4,140 18 9.4 15 x1.0** 28 x1.5 74 300 230 V -1 1,350 75 0.35 Subject to modification. Standard condition t L1 t 0 DT1 NB 1 / SC 1 +10 0 10 NB 2 / SC 2 0-8 8 * Single injection ** Multiple injection via flow distributor *** Throw limit at 0.5 m/s Operating values are the values of the built-in motor at +20 C, with an unobstructed air flow and a dry surface Küba compact DF Technical data DFB (E) B 7 mm Type Rating Q 0 at 50 Hz. DT1. R404 A Cooling surface Air flow Air throw Tube volume Connections Sound Fans (Operational values at 50 Hz) SC2 SC3 *** Inlet Outlet L WA Blade Current Per Fan kw kw m 2 m 3 / h m dm 3 Ø mm Ø mm db (A) Ø mm 230 ± 10% V-1 50 Hz rpm W A 1 2 3 4 DFB 051 D 1.5 1.1 4.6 1,070 9 1.4 10 x1.0* 12 x1.0 68 300 230 V -1 1,350 75 0.35 DFB 061 D 1.8 1.5 5.5 1,300 11 1.7 10 x1.0* 12 x1.0 68 300 230 V -1 1,350 75 0.35 DFB 071 D 2.1 1.8 8.2 1,130 11 2.5 10 x1.0* 18 x1.0 68 300 230 V -1 1,350 75 0.35 DFB 052 D 2.9 2.2 9.2 2,140 11 2.7 10 x1.0* 18 x1.0 71 300 230 V -1 1,350 75 0.35 DFB 062 D 3.5 2.9 11.1 2,600 13 3.2 12 x1.0** 22 x1.0 71 300 230 V -1 1,350 75 0.35 DFB 072 D 4.1 3.5 16.5 2,260 13 4.8 12 x1.0** 22 x1.0 71 300 230 V -1 1,350 75 0.35 DFB 063 D 5.1 4.3 16.6 3,900 15 4.8 12 x1.0** 22 x1.0 73 300 230 V -1 1,350 75 0.35 DFB 073 D 6.2 5.3 24.7 3,390 15 7.1 12 x1.0** 28 x1.5 73 300 230 V -1 1,350 75 0.35 DFB 064 D 6.9 5.8 22.1 5,200 18 6.3 12 x1.0** 28 x1.5 74 300 230 V -1 1,350 75 0.35 DFB 074 D 8.5 7.0 33.0 4,520 18 9.4 15 x1.0** 28 x1.5 74 300 230 V -1 1,350 75 0.35 Subject to modification. Standard condition t L1 t 0 DT1 NB 2 / SC 2 0-8 8 NB 3 / SC 3-18 -25 7 * Single injection ** Multiple injection via Küba-CAL distributor *** Throw limit at 0.5 m/s Operating values are the values of the built-in motor at +20 C, with an unobstructed air flow and a dry surface [ 8 ] Küba compact DF Küba Green Line

Dimensions, weights, electric defrost, drain Type Dimensions Electrical defrost 230 V-1 / 400 V-3-Y Weights (net) Weights (gross) H B T L E 1 E 2 F W min Coil DF A/B DF A/B E DF A/B DF A/B E D Drain mm mm mm mm mm mm mm mm kw kg kg kg kg inch DF 051D 268 872 626 612 530-171 100 1.1 20 20 23 23 G ¾ DF 061D 268 972 626 612 630-171 100 1.2 23 23 26 26 G ¾ DF 071D 268 972 626 612 630-171 100 1.2 25 25 28 28 G ¾ 1 Subject to modification. DF 052D 268 1,372 626 612 1,030-171 100 1.8 32 32 54 54 G ¾ DF 062D 268 1,572 626 612 1,230-171 100 2.1 37 37 60 60 G ¾ DF 072D 268 1,572 626 612 1,230-171 100 2.1 40 40 63 63 G ¾ DF 063D 268 2,172 626 612 1,830 629 171 100 3.0 52 52 88 88 G ¾ DF 073D 268 2,172 626 612 1,830 629 171 100 3.0 56 56 92 92 G ¾ DF 064D 268 2,772 626 612 2,430 1,229 171 100 3.9 68 68 108 108 G ¾ DF 074D 268 2,772 626 612 2,430 1,229 171 100 3.9 75 75 115 115 G ¾ 2 3 4 The dimensions are only valid for the standard model design! Note the differences in dimension among versions and accessories. Dimensional drawings for compact DF (1-4 motors) 11,5 L W min 11,5 E 1 315 H±5 B ±5 D T 368 714 E 1 B ±5 E 1 E 2 B ±5 E 1 E 2 B ±5 Küba compact DF Küba Green Line [ 9 ]

Variants Motor-Variants Construction-variants V 1.33 Fans, silent version Fans 230V±10% V-1~ 50/60 Hz; 1.100 rpm Reduced air volume flow Lower sound power level V 1.50 EC fans with fixed speeds Fixed fan speed at optimal operating point V 1.52 EC fan with controllable speed Fans adjustable V 2.05 Water / brine circulation With a large number of distributors (small pressure drop) V 2.06 Water / brine circulation With a small number of distributors (large pressure drop) CO 2 -Variants V 7.45 CO 2 -Direct expansion up to 45 bar operating pressure Protection against corrosion V 7.60 CO 2 -Direct expansion up to 60 bar operating pressure V 6.01 Corrosion protection 1 Tubing: Copper Fins: Aluminum, epoxy-resin-coated End plates: Aluminum protective coating Casing: Aluminum/zinc coated steel, protective coating on both sides V 6.04 Corrosion protection 4 Tubing: Copper Fins: Aluminum, epoxy-resin-coated End plates: Aluminum Casing: Aluminum/zinc coated steel, protective coating on on one side [ 10 ] Küba compact DF Küba Green Line

+ Küba compact DF Accessories Accessories Electric heater DFHR For air coolers with forced-draft fans, for assembly on site. Suitable for air conditioning, or heating, in the winter. For optimal heat transfer, the heater rods are fitted in Cu tube sleeves. Fully powder-coated (RAL 9018) 230 ± 10% V-1~ or 400 ± 10% V-3~ -Y Heater rods with CrNi steel sleeve Vapour-tight connections Connecting cable 1.0 mm 2 x 1000 mm Casing: steel, continuous hot-dip zinc coated Fins: aluminium Tube sleeves: Cu Selection table & dimensions: For type Description Dimensions Weight Current Capacity H L kg A kw DF 051 D DFHR 500 210 500 1.4 3.7 0.8 DF 061 D DFHR 600 210 600 1.7 4.2 1.0 DF 071 D DFHR 600 210 600 1.7 4.2 1.0 DF 052 D DFHR 1000 210 1,000 2.4 7.5 1.7 DF 062 D DFHR 1200 210 1,200 2.9 8.3 1.9 DF 072 D DFHR 1200 210 1,200 2.9 8.3 1.9 DF 063 D DFHR 1800 210 1,800 4.2 12.5 2.9 DF 073 D DFHR 1800 210 1,800 4.2 12.5 2.9 DF 064 D DFHR 2400 210 2,400 5.6 16.3 3.8 DF 074 D DFHR 2400 210 2,400 5.6 16.3 3.8 Note: Operate only when the air cooler fans are running, to prevent the cold storage ceiling from overheating. Please observe the corresponding safety guidelines. Küba compact DF Küba Green Line [ 11 ]

www.brand-change.com GEA Küba GmbH Kühler Weg 1 82065 Baierbrunn Deutschland Tel.: ++49 (0) 89 / 744 73-0 Fax: ++49 (0) 89 / 744 73-107 kueba@gea.com www.kueba.de Copyright 2015 GEA Küba GmbH 0094.392BR.DFCD.EN Status as of 08 / 2015 Subject to technical changes