Inductive sensor With analog output BI15-M30-LI-EXI

Similar documents
Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI10-M18-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Capacitive sensor BCT5-S18-UP6X2T-H1151

Read/Write Head TN-M30-H1147

Read/write head TN-M18-H1147

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Read/write head TN-CK40-H1147

Read/Write Head TN-CK40-H1147

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Read/Write Head TNSLR-Q42TWD-H1147

Read/Write Head TNLR-Q80L400-H1147L

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Rotative measurement Incremental rotary encoder Ri-10S10C-2B4096-H1181

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Photoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Photoelectric sensor Photoelectric Sensor for Plastic Fibers DF-G1-KS-Q7

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM8

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

TFRH Hygienic RTD temperature sensor. CombiTemp TM

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT

TFRN Industrial RTD temperature sensor. CombiTemp TM

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

TFRN Industrial RTD temperature sensor. CombiTemp TM

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

APPLICATIONS. Automatic warehouse. Trasportation lines

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC

APPLICATIONS. Automatic warehouse. Trasportation lines

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

EXPlora. Introduction

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Pendant Light Fitting IEC Series 6470/2

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

The full range of performance

TFR5 Room or outdoor temperature sensor. CombiTemp TM

3 Cleaning. 4 Technical data

PMG. Vibration Energy Harvesters

DMP 331i / DMP 333i LMP 331 i

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

BL compact Fieldbus Station for CANopen 4 Digital PNP Outputs BLCCO-4M12MT-4DO-0.5A-P

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Pressure transmitter For applications in hazardous areas Model IS-3

>Inductive and CATALOG. Capacitive Sensors

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Photoelectrics Through-beam Type PA18C.T..., DC

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

7 Lighting Technology

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Quality products from a single source

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

TW-R30-K2. FRAM memory 2 kb. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

EtherCAT Set in IP20 TI-BL20-E-EC-S-4

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Connectivity for Ethernet

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Photoelectric Sensors E3F2

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

PROPORTIONAL VALVES Sentronic plus

Cylindrical Photoelectric Sensor CY-100 SERIES

SERIES 400 SERIES 620

>Inductive. REFERENCE guide. Proximity

Inductive coupling. 10 mm +/-0.2 mm

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

RSCC. Load cells. Special features. Data sheet

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

TW-R16-B128. EEPROM, memory 128 byte. Functional principle The HF read/write heads operating at a frequency of MHz, form a transmission

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

>Inductive and. REFERENCE guide. Capacitive Sensors

I Ex-protected connectors exlink I

Transcription:

ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation Ident no. 1535554 Measuring range [A B] 2 mm 10mm mm Mounting conditions Flush Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeatability ð 1 % of measuring range A - B ð 0.5 %, after warm-up 0.5 h Linearity deviation ð 5 % Temperature drift ð ± 0.06 % / K Ambient temperature -25 +70 C For explosion hazardous areas see instruction leaflet Measuring Range Operating voltage Residual ripple Isolation test voltage Short-circuit protection Wire breakage/reverse polarity protection Output function Current output Load resistance current output Measuring sequence frequency 14 30 VDC at the electrical connection of the sensor ð 10 % U ss ð 0.5 kv yes no/ Complete 2-wire, Analog output 4 20 ma ð [(U B -14 V) / 20 ma] kò 140 Hz Approval acc. to KEMA 03 ATEX 1122 X Issue no. 4 Design Threaded barrel,m30 1.5 Dimensions 64 mm Housing material Metal, CuZn, Chrome-plated Active area material Plastic, PA12-GF30 End cap Plastic, EPTR Max. tightening torque housing nut 75 Nm Electrical connection Cables Cable quality 5.2 mm, Blue, LifYY, PVC, 2m Cable cross section 2 x 0.34 mm 2 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 751 years acc. to SN 29500 (Ed. 99) 40 C Packaging unit 1 1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Distance D Distance W Distance T Distance S Distance G 60 mm 27 mm 3 x B 45 mm 54 mm Diameter active area B Ø 30 mm 2 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description IM33-14EX-CDRI 7560015 Isolating transducers; 1-port; power supply of 2-wire measuring transducers with HART communication as well as connection of active 2-wire and passive 3-wire transmitters, SIL2 according to IEC61508 BST-30B 6947216 Fixing clamp for threaded barrel devices, with dead-stop; material: PA6 QM-30 6945103 Quick-mount bracket with dead-stop; material: Chrome-plated brass Male thread M36 x 1.5. Note: The switching distance of proximity switches can be reduced by the use of quick-mount brackets. MW-30 6945005 Mounting bracket for threaded barrel devices; material: Stainless steel A2 1.4301 (AISI 304) BSS-30 6901319 Mounting bracket for smooth and threaded barrel devices; material: Polypropylene 3 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories Type code Ident no. Description IM33-11EX-HI 7506443 Isolating transducers; 1-channel; power supply of 2-wire measuring transducers with HART communication as well as connection of active 2-wire and passive 3-wire transmitters 4 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 2 D (Group II, Category 1 G, electrical equipment for gas-atmospheres and category 2 D, electrical equipment for dust atmospheres) Marking (see device or technical data sheet) É II 1 G Ex ia IIB T6 Gb und É II 2 D Ex ia IIIC T85 C Db nach EN 60079-0, -11 Local admissible ambient temperature -25 +65 C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 5 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com