Easy and Quick "Checking Power" at the Worksite

Similar documents
ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Selector Switches 30-mm Selector Switches Universal Design. Emphasis on Color Coding, Workability, and Safety. Operation Unit Colors

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Solid-State Digital Timer

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Bimetal Temperature Switch

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Hybrid Chart Recorder 250 mm (10")

EVENT INPUT/OUTPUT MODULE [PUME]

Multifunction Digital Timer

Absolute Rotary Encoder E6CP

Model Number Structure

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Accessories. Servo Motors. Servo Motors B-47. Accessories

Digital Temperature & Analog Sensor. Analog Input Port. Digital Port. Front

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

General Specifications

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Photoelectric Sensors E3F2

Safety Light Curtains

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

HOBO H Energy Logger

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

USER S MANUAL. FX2N-8AD Analog input block

Absolute Encoders Multiturn

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

Wall-/Pipe-Mount Level Indicator

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

SCALE & WEIGHT DISPLAYS

POWER MONITORS ENERIUM RANGE. Minimize your energy consumption and optimize your installation

OM2000N INSTALLATION MANUAL

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Clamp 200 A AC/DC (+ V AC/DC + Ω)

MS2540 Current Loop Receiver with RS485 Communication

TeamWork Kits Installation Guide

AF-300 E11 Adjustable Frequency Drive

0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

LAUREL ELECTRONICS, INC.

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Gamma instabus. Technical product information

Modular Matrix Solution. Complete A/V Signal Control in One Expandable System.

High performance circuit breakers

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

ex 800 Series ematrix System

Getting started with

Standard RS232 RS ma

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Ultra Small Surface Mount Coaxial Connectors 1.4mm Mated Height

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

Detect Color and Shape for various inspection

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Getting started with

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

VBOX III 100Hz GPS Speed Sensor. User Guide. Page 1 of 21. VBOX III SPS User Guide

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

SIMATRIX NEO V2 Modular Video Matrix

Advantech Proudly Presents Professional Monitor Series

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Network Camera Operating Manual

Model ED 400 Drying and heating chambers Classic.Line with natural convection

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

Magnetic Sensor - Incremental EHP

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

ODW-621. RS-232 Point-to-point applications

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

LCD MODULE SPECIFICATION

DM1624, DM1612, DM812

02/11/2015

multi-function meters

VOB - data over Video Overlay Box

Micro-DCI 53ML5100 Manual Loader

Solis Export Power Manager

Lt DELTA USA, Inc

Luminaire installation box Surface-mounted box Ceiling installation box

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

VT-S730. Omron's 3D-SJI For Efficient Manufacturing of High-quality Products. Best the Minimum Q cost! PCB Inspection System VT-S730 NEW

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

Junior Max (JR Max ) Controller

Certificate of Calibration

Transcription:

N EW New-generation environmental sensor TM Series ZN-CTX2 (Logging unit) ZN- CTM (Dedicated CT unit) I do not want to stop the machine to just check power. Whene ver n eed ed, Do you have the concerns about power measurement? evel of electricity cons l e h um yt ptio ntif e ni d i mm n ca. worksite our at y ely iat ed yo u Easy and Quick "Checking Power" at the Worksite It's troublesome to install the measuring equipment, when you want to check power. It takes time to collect data. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. OMRON Corporation Tokyo, JAPAN Industrial Automation Company Authorized Distributor: Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-232 JD Hoofddorp The Netherlands Tel: (3)2356-8-300/Fax: (3)2356-8-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 6073-5302 U.S.A. Tel: () 847-843-7900/Fax: () 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 9967 Tel: (65) 6835-30/Fax: (65) 6835-27 OMRON (CHINA) CO., LTD. Room 22, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 20020, China Tel: (86) 2-5037-2222/Fax: (86) 2-5037-2200 Logging unit (actual size) OMRON Corporation 202 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. E49-E-0 02 Now this Clamp Type is available For more information

N EW New-generation environmental sensor TM Series ZN-CTX2 (Logging unit) ZN- CTM (Dedicated CT unit) I do not want to stop the machine to just check power. Whene ver n eed ed, Do you have the concerns about power measurement? evel of electricity cons l e h um yt ptio ntif e ni d i mm n ca. worksite our at y ely iat ed yo u Easy and Quick "Checking Power" at the Worksite It's troublesome to install the measuring equipment, when you want to check power. It takes time to collect data. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. OMRON Corporation Tokyo, JAPAN Industrial Automation Company Authorized Distributor: Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-232 JD Hoofddorp The Netherlands Tel: (3)2356-8-300/Fax: (3)2356-8-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 6073-5302 U.S.A. Tel: () 847-843-7900/Fax: () 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 9967 Tel: (65) 6835-30/Fax: (65) 6835-27 OMRON (CHINA) CO., LTD. Room 22, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 20020, China Tel: (86) 2-5037-2222/Fax: (86) 2-5037-2200 Logging unit (actual size) OMRON Corporation 202 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. E49-E-0 02 Now this Clamp Type is available For more information

Our Further Proposals on Power Checkup Quality Strong Support for Construction of a Monitoring System Power is indicated based on CT(current) Energy Temperature and humidity Minute differential pressure Thermo-Humidity Station Differential Pressure Station visualize Extra Energy Particles For monitoring of the power of an entire building What you do is just connecting CT. There is no need for wiring for voltage measurement. 5F KM50 Battery-powered, Fixed by Magnet and Ultra-thin F ZN-CTX2 OPTION Environmental Visualization Software Machine ZN-SW-S KM50 This software is recommended for real-time display (monitoring) of waveforms. Air conditioners Lighting equipment External power source is not necessary. Easy to mount with the attached magnet. Air particle sensor, Dust measurement type LAN Air conditioners Lighting equipment 2F Air particle sensor, Particle measurement type Machine Environmental information + are displayed in synchronization on a real-time basis KM20 For example, this software synchronizes "cleanliness (environmental information)" and "electric power for a clean room" in the display on a real-time basis. in manufacturing areas of a device Machine A Machine B Machine C Temperature and humidity Changes in cleanliness in a device Ultra-easy Way of Logging Electricity A single button operation logs, in block, the data on 3 KM series units. You can collect data from SD card while sitting in your office. Data on 3 units of KM series for electric power monitoring can be logged, in block to the SD card. Logging starts with one push of a button. Using an FTP (File Transfer Protocol) tool in the marketplace enables you to import the data saved on the SD card to your PC over a network. Temperature and humidity Waveforms are automatically scrolled in a clean room Differential pressure inside and outside of a clean booth Changes in electric power Particles Differential pressure in a device in a clean room The single push of a button starts recording. Sum and value recorded on each KM are displayed Air flow Particles inside a clean booth in a clean room It displays environmental information and electric power on a layout drawing in the worksite in a manner that enables you to understand them at a glance. There are two types of displays. This display pops up when an alarm is detected Debut of a Smart and Easy to use! This Monior easily solves troubles for measuring power! This software supports linkage with various software products in the marketplace. Alarm output terminal LAN port SD card slot Thanks to the automatic transfer function in Excel and the mail transmission function when an alarm is generated, data administration and monitoring of a worksite are made easier. LAN Easily connected with the attached cable Up to 3 units are connectable in RS-485 communication The attached software easily enables graphic representation of the saved data. You can set the connected KMs at a time by use of the special tool. Dedicated software Easy KM Manager for KM series is used for setting KMs. For example, displaying "cleanliness" and "electric power of an air conditioner" synchronously and at the same time, you can identify excess energy in relation to the given quality control standard. Then,improving operation and enhancing control allows you to reduce extra energy while maintaining an optimum quality level.and since both quality and energy are visualized, the influence to the quality and the effect of electric-energy cut down is obvious. Before energy-saving measures Electricity for air conditioning Energy-saving Supporting Equipment for Monitoring System Compact Power Sensor Smart Power Monitor Sensor network controller KM20-B40-FLK KM50-C-FLK KM50-E-FLK EW700-M20L Measurement on the primary side of the inverter Measurement on the primary side of the inverter Downsized Measurement of minute electricity Less expensive Pulse count for production and flow rate Electricity for air conditioning Air conditioner output is controlled according to the environmental quality Connects KM units up to 24 Collects every sensor data including KM series Environmental particles Environmental particles Extra energy Alerts you by mail if an abnormality is detected Carry-in of products Clamp type CT After energy-saving measures Reduced energy Operates at a constant output Particles control standard Split type CT Real-time monitoring on the map display is also available Visualization of Extra Energy, a Blind Side in Energy Saving The same software as that for the ZN-CTX2 is attached. It provides graphic representation of the data saved on the SD card and PC with ease. Bar graph indication of instantaneous electricity is also available! Cleanliness is maintained at a high level until products are carried in. Particles level is still under the standard level after the air conditioner turns down.

This single unit solves all the problems you have with power checking at your You can rely on it for your energy saving activity. Many of the currently used power meters are not suitable for easily measuring power of a variety of machines and distribution boards. As a result, the electric power of a great number of machines in worksites is left unmeasured. Our ZN-CTX2 solves such problems. It is the industry's first "portable power monitor for energy-saving activities at the worksite." It is "usable for anyone" "with ease" and indicates measurements "on site" immediately. This new concept-based ZN-CTX2 will make a great contribution to energy-saving activities at the worksite. There is no need to stop machines and production lines. Just setting the CT completes the preparation. Electrical power equivalent is caluclated on a real-time basis.* There is no need to stop the power supply. Current value (measured value) Electric Power value (equivalent value) Automatically calculated into electrical power equivalent. * Since electricity is calculated based on current value alone, a certain margin of error may result when fluctuations are present in voltage and power factors. Compact design with the battery-powered. It is installable anywhere. It works for a week on the battery.* It can be installed inside the distribution board using the magnet. * In sleep mode,battery life depends on the measurement environment as well as the type and performance of the given battery. Note: A manganese battery is not usable. It takes hardly any time to collect data. Easy logging and quick display Necessary data alone are logged Ranking can be displayed. Push the button for 3 seconds!

worksite! Five Types of Dedicated CT units for Various Applications Clamp type CT is added to the lineup. Four types of split type CTs and a clamp type CT (200A) configure the lineup. The clamp type CT provides easy measurement in locations that are difficult for CTs of other types. LAN port Data logging through networks is available. Setting of the monitor is also possible. DC cable DC cable is available for long hours logging. Clamp type CT is detachable with the single touch of a button. ZN-CTS5-200A Measurment range:.2 to 240 A CT inside diameter: 23 dia. Downsized and less expensive split type CT ZN-CTS-5A Measurment range: 0.03 to 6 A CT internal diameter: 7.9mm dia. ZN-CTS-50A ZN-CTS-00A Measurment range: 0.3 to 60 A Measurment range: 0.6 to 20 A CT internal diameter: 9.5mm dia. CT internal diameter: 4.5mm dia. Refer to the List of specifications on applicable cable diameter. ZN-CTS-200A Measurment range:.2 to 240 A CT internal diameter: 24.0mm dia. Power Consumption Checkup covers Devices to Distribution Boards Changing the number of CTs connected to the branch cable enables measurement of single-phase 3-wire, three-phase 3-wire (unbalanced voltages in three-phase system) and three-phase 4-wire, too. Checkup of electricity on distribution boards is also supported. SD card slot You can easily collect logged data by using SD card. Alarm output terminal Alarms when an error occurs. Single-phase 2-wire Single-phase 3-wire Three-phase 3-wire Three-phase 4-wire Branch cable ZN-CTM-C Easy connection up to three CTs. + Dedicated CT (branch type) ZN-CTM[]-[][]A * Up to three CTs are connectable. Checkup at the Time and Behavior to Watch Out for Standby Electricity is also not Overlooked Display of cumulative electric power (equivalent value) When logging is started, the upper space displays the time and the lower space displays cumulative electric power (equivalent value). In this way, you can check electric power used from the start to the end of logging.you can set the logging conditions not only from the buttons but also by specifying the starting time or elapsed time. START STOP Automatic range selection function Our product is capable of measuring minute electric current that has been immeasurable by existing models. This feature enables you to check electricity consumption of a machine on standby. When the range is fixed (previous model) When automatic range selection is enabled Start your logging at the time to watch for Five minutes after Stop logging when the necessary data has been collected. Stop logging when one cycle of the target device is over or Current on standby is not measured and indicated as zero. Standby electricity is not overlooked! Starting time Ending time Elapsed time Note: If a measurement value becomes 5% or less than the rated current, the minute range is selected.

List of specifications Ordering Information Appearance Logging unit (rating) Product name Logging unit Power supply Dedicated CT unit Product name Branch cable (cable length.3 m) ZN-CTM-C ZN-CTM-5A ZN-CTM-50A Split type CT Connector: For connecting the branch cable Cable length: 0.2 m ZN-CTM-00A ZN-CTM-200A Clamp type CT Connector: For connecting the branch cable Cable length: 0.2 m ZN-CTM5-200A Guideline for selecting dedicated CT unit Branch cable ZN-CTM-C 2 2 3 * Up to three dedicated CTs for branch type are connectable to the branch cable.be sure, however, not to connect a CT of different rated current.correct measurement will be blocked. (Necessary quantity is indicated in the table) Example of use I need to know which machine consumes electricity most! Data is ranked in descending order of cumulative electric power. Logging of 0 minutes is carried out for each machine Cumulative value up to the stop Machine A Machine B Ranking Machine C Logging unit (rating) Primary side rated current Secondary winding Applicable frequency Insulation resistance Withstand voltage Protection element Allowable frequency of disconnection Inside diameter of clamp core Operating temperature and humidity range Storage temperature and humidity range Voltage of circuit used ZN-CTM-5A ZN-CTM-50A 5A 50 A ZN-CTM-00A ZN-CTM-200A ZN-CTM5-200A 00 A 200 A 200 A 3,000 turns 0 Hz to 5 khz Between output terminal and case: 50 MΩ minimum (500 VDC megohms) Between output terminal and case: 2,000 VAC minute 7.5 V clamp element 5,000 times 00 times 0 dia. 6 dia. 24 dia. -20 C to +60 C 85% maximum (no condensdtion or icing) -30 C to +65 C 85% maximum (no condensdtion or icing) Primary side rated current Primary side allowable input current Accuracy Measurement target frequency Recording values Applicable circuit ZN-CTX2-A Dedicated CT (5 A/50 A/00 A/200 A) 20% of rated current (Continue) ±2.0%FS± digit (Ambient temperature 23 C, rated input, rated frequency) * 50 Hz/60 Hz Current value, instantaneous power, integrated power consumption Single phase two-wire, single phase three-wire, three-phase three-wire, three-phase four-wire Stop Machine C The portable power monitor displays the cumulative electric power from the start to stop times producing records during this period as a single piece of data. 3:2 3:22 5:32 5:42 6:2 6:22 -A Power supply DC cable Current Consumption Operating Temperature Station unit Energy consumption from 8:00 to 9:00 is the most. Data is ranked in descending order of cumulative electric power. 24-hour logging in one batch Cumulative value during a specified durationof time Ranking 0 Screen display 8:00-9:00 no. 08:00 9:00-0:00 Cumulative value during a specified duration of time (30 minutes, hour or 24 hours) is finalized.the portable power monitor displays the cumulative electric power during a period of time as a single piece of data.(example: If you specify 30 minutes for the duration and continue logging for 24 hours, you will get 48 pieces of data.) no. 32kWh no.2 09:00 No.2 Time KM20-B40-FLK, KM50-C, KM50-E, KM00 3 units 7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays s, 2 s, 5 s, 0 s, 20 s, 30 s, min. Momentary power, Integrated power, Power factor, Sum of pulse input counts and 2 * Integrated power total sum, integrated momentary power, electricity rate total sum Continue mode*2, Ring mode *3 Alarm output (Photocoupler output) *4 Internal memory: approx. 200 data items (at maximum load); approx. 6800 data items *5 (at minimum load) SD card with SDHC compatibility (Save measured values, save and read setting values) DC input: 24 VDC±0% -A 4:00-5:00 Energy Viewer For checking the current use of electricity This software is suitable for displaying power consumption for a certain time unit such as minute, 30 minutes and 24 hours.its bar-graph representation is best suited for indicating cumulative electric power. You can change the display period with the one click. It allows past data to be displayed side by side for comparison. For example, you can display electric power of a different month on a daily basis for comparison. no.2 8kWh no.3 4:00 No.3 no.3 2kWh Precision Thermo-Humidity Logger ZN-THX-SA 80 ma max. Without Ethernet: -0 C to 40 C (no condensation or icing) With Ethernet: 0 C to 40 C (no condensation or icing) Operating Humidity 20% to 85% (no condensation or icing) Storage Humidity/Temperature -5 C to +60 C, 20% to 85% (no condensation or icing) Insulation Resistance 20 MΩ (500 VDC) Withstand Voltage 000 VAC, 50/60 Hz, min. Vibration Resistance 0 to 50 Hz, 0.7 mm double amplitude, acceleration: 50 m/s2 for each in X, Y and Z directions for 80 min*6 Shock Resistance 50 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each*6 Material ABS Degree of Protection IP30 Mounting Magnet mounting, screw mounting, hook, free standing Weight (in Package) Approx. 500 g Accessories Instruction Sheet, Startup Guide, Utility Disk (CD-ROM)*7, Alarm Output Connector*8, KM Dedicated Connection Cable(3 m), DC Cable, and Ferritecore. *: Only supported for KM50-C and KM50-E. *2: Automatically writes the data to the SD memory card when the internal memory reaches its capacity and continues recording until the SD card memory capacity reaches its limit. The unit stops operation if there is no SD memory card inserted when the internal memory reaches its capacity. (Recording can be resumed after inserting an SD memory card and outputting the data to it at a press of button.) *3: Continues the recording of the latest measured values until the internal memory reaches its capacity. (If the internal memory capacity exceeds the capacity, data is overwritten from the oldest one in the memory.) *4: Output when the integrated power upper limit specified in THR mode is exceeded. *5: The maximum load is applied when 3 KM50-@ units are connected; and the minimum load, when a single KM20-B40-FLK is connected. *6: The vibration resistance when mounted using the ZN9-EM0-S magnets (separately sold): 0 to 55 Hz, 0.3mm double amplitude, acceleration: 20m/s2 for each in X, Y and Z directions for 50 min. The installation place must be free from physical shock. *7: The Utility Disc includes SD Viewer software, Energy Viewer software and manual pdf. The provided software operating environment/os: Windows XP / Windows Vista / Windows 7; CPU: Intel-compatible processor.5ghz or higher; Memory: GB or more (Recommended: 2 GB or more) *8: OMRON's XW4B-02B-H connector. 0 MODE NORM Application example for a molding machine 0 Injection State of the machine is checked by its waveforms! * Cooling An overlap display shows at a glance the change before and after the improvement. This mode shows the power-consuming device states, which were invisible in normal mode. Takeoff Time High-speed logging mode This software allows you to display temperature and humidity data recorded with the Precision Thermo-Humidity Logger (ZN-THX-SA) at the same time in a line graph. I need energy-saving measures for a machine of high-speed operation (Several seconds for cycle of operation). Normal mode Memory Capacity (External) Power Supply -A Time zone No. Connectable Power Sensor/Monitor Max. Number of Connectable Power Sensor/Monitor Units Display Recording Interval Recorded data Operation Function Recording Mode External Output Memory Capacity (Internal) no.3 2kWh I need to know in which time zone electricity is consumed most! Accumulation reset mode Rating and performance Select the data you want to display and graphic representation of the data is readily available. Two Software Programs for Use in a Manufacturing Setting are bundled. Example of use High-speed logging mode Station unit Station unit Start the software and select the desired folder. The software identifies the data type and displays the data on the screen. no.2 5kWh no.3 6:2 No.3 Step3 no. 8kWh no.2 3:2 No.2 Time Example of use no. 5:32 Logged data is collected with an SD card and read to a PC. 23 dia. 480 VAC maximum Product name Machine B Step2 * An error of the dedicated CT is not included. Ordering Information Apperarance Screen display No. Stop Dedicated CT unit (rating and performance) Time zone Machine A 0 Start Step Machine B consumes the most! Normal cumulative mode Applicable circuits Single-phase 2-wire Single-phase 3-wire Three-phase 3-wire Three-phase 4-wire CT exclusive for branch type ZN-CTM-A (*) *: Momentary power and integrated power values are converted from the measured current. Correctly specify the number of used channels, applicable measurement target circuit, CT type, frequency, voltage and power factor. *2: The display turns OFF after 0 seconds of no user operation and recovers by a key operation when SLEEP mode is specified. LAN cannot be used when sleep mode is specified. *3: Automatically writes the data to the SD memory card when the internal memory reaches its capacity and continues recording until the SD card memory capacity reaches its limit. The unit stops operation if there is no SD memory card inserted when the internal memory reaches its capacity. (Recording can be resumed after inserting an SD memory card and outputting the data to it at a press of button.) *4: Continues the recording of the latest measured values until the internal memory reaches its capacity. (If the internal memory capacity exceeds the capacity, data is overwritten from the oldest one in the memory.) *5: Output when the integrated power upper limit specified in THR mode is exceeded. An alarm output is not available in SLEEP mode. *6: Nickel-metal hydride cells or alkaline dry cells can be used. Manganese battery cells cannot be used. *7: Battery life varies depending on the measurement environment, recording interval, operation mode as well as the battery type and performance. *8: Conditions: Two AAA nickel-metal hydride cells; Sleep mode; Continue mode; Recording interval: s; SD memory card: HMC-SD29; Operation temperature: 23 C ; and Automatic range selection off *9: The installation place must be free from physical shock when using mounting magnets. *0: The Utility Disc includes SD Viewer software, Energy Viewer software and manual pdf. The provided software operating environment/os: Windows XP / Windows Vista / Windows 7; CPU: Intel-compatible processor.5ghz or higher; Memory: GB or more (Recommended: 2 GB or more) *: Already installed on the product by factory default. *2: OMRON's XW4B-02B-H connector. Logged Data can be shown in a Graph immediately with the Attached Software. Simple and Convenient Check of Power ZN-CTM - A 7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays s, 2 s, 5 s, 0 s, 20 s, 30 s, min. Momentary power, Integrated power consumption Normal mode, Sleep mode *2, High-speed logging mode Continue mode*3, Ring mode*4 Alarm output (Photocoupler output) *5 Internal memory: approx. 6500 data items SD card with SDHC compatibility (Save measured values and converted values; save and read setting values) DC input: 24 VDC ± 0%; Power Supply Batteries: Two AAA batteries*6 80 ma max. Current Consumption Approx. week *8 Battery Life *7 Battery Supply: -0 C to 60 C (no condensation or icing) Operating Temperature 20% to 85% (no condensation or icing) Operating Humidity Storage Humidity/Temperature -5 C to +60 C, 20% to 85% (no condensation or icing) 20 MΩ (500 VDC) Insulation Resistance 000 VAC, 50/60 Hz, min.: Between the case and current input circuit Withstand Voltage With mounting screws: 0 to 50 Hz, 0.7 mm double amplitude, acceleration: Vibration Resistance 50 m/s2 for each in X, Y and Z directions for 80 min. With mounting magnets: 0 to 55 Hz, 0.3 mm double amplitude, acceleration: 20 m/s2 for each in X, Y and Z directions for 50 min. 50 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each *9 Shock Resistance ABS Material IP30 Degree of Protection Magnet mounting, screw mounting, hook, free standing Mounting Approx. 500 g Weight (in Package) Instruction Sheet, Startup Guide, Utility Disk (CD-ROM)*0 Mounting Magnets*, Accessories Alarm Output Connector*2, DC Cable, and Ferrite Core Battery/DC cable ZN-CTX2-A ZN-CTX2-A Connectable sensor Display Recording Interval Operation Function * Measurement Mode Recording Mode External Output Memory Capacity (Internal) Memory Capacity (External) Branch type Appearance Helpful for these cases Rating and performance Logging unit Check boxes are for you to display only the data you want to view. A buildup display helps identify a machine, time slot, day, etc. that consumes more power at a glance. Before improvement 2 MODE HISPD 3 SD Viewer This software is suitable for displaying changes in instantaneous power such as data being logged on a second basis. Time 0 The high-speed mode logs data every 00ms*. High-speed logging mode * Data logging at 60 Hz completes in 83 ms and 00 ms at 50 Hz. Normal mode After improvement For analysis of electricity on a second basis Cumulative display of electric power shows the difference in electric power before and after the improvement. Time The display is freely changeable depending on the length of cycle of the target of measurement.

Logged Data can be shown in a Graph immediately with the PC Software. Step Logged data is collected with an SD card and read to a PC. Step2 Start the software and select the desired folder. The software identifies the data type and displays the data on the screen. Step3 Select the data you want to display and graphic representation of the data is readily available. Two Software Programs for Use in a Manufacturing Setting are bundled. Energy Viewer For checking the current use of electricity This software is suitable for displaying power consumption for a certain time unit such as minute, 30 minutes and 24 hours.its bar-graph representation is best suited for indicating cumulative electric power. You can change the display period with the one click. It allows past data to be displayed side by side for comparison. For example, you can display electric power of a different month on a daily basis for comparison. Precision Thermo-Humidity Logger ZN-THX-SA This software allows you to display temperature and humidity data recorded with the Precision Thermo-Humidity Logger (ZN-THX-SA) at the same time in a line graph. An overlap display shows at a glance the change before and after the improvement. Check boxes are for you to display only the data you want to view. A buildup display helps identify a machine, time slot, day, etc. that consumes more power at a glance. Before improvement SD Viewer For analysis of electricity on a second basis This software is suitable for displaying changes in instantaneous power such as data being logged on a second basis. After improvement Cumulative display of electric power shows the difference in electric power before and after the improvement. The display is freely changeable depending on the length of cycle of the target of measurement. Note: Download the PC Software Station Utility Energy Viewer / SD Viewer ES) from the following OMRON website (http://www.fa.omron.co.jp/station-u-e).

Our Further Proposals on Power Checkup Strong Support for Construction of a Monitoring System For monitoring of the power of an entire building KM50 LAN 5F Air conditioners Lighting equipment Machine KM50 2F Air conditioners Lighting equipment Machine KM-N2 F Machine A Machine B Machine C The PC software easily enables graphic representation of the saved data. A single button operation logs, in block, the data on 3 KM series units. The same software as that for the ZN-CTX2 is available. It provides graphic representation of the data saved on the SD card and PC with ease. Data on 3 units of KM series for electric power monitoring can be logged, in block to the SD card. The single push of a button starts recording. Sum and value recorded on each KM are displayed You can set the connected KMs at a time by use of the special tool. Easily connected with the attached cable LAN port Alarm output terminal SD card slot Dedicated software Easy KM Manager for KM series is used for setting KMs. NOTE : Operation is guaranteed only for functionality related to Unit setting. NOTE 2: The Easy KM Manager does not support the KM-N-FLK, KM-N2-FLK, and KM-N3-FLK. Up to 3 units are connectable in RS-485 communication NOTE: To directly connect KM-N-FLK, KM-N2-FLK and KM-N3-FLK to the product, please purchase a separately sold dedicated connection cable ZN9-KMC30-N. Energy-saving Supporting Equipment for Monitoring System Compact Power Sensor Smart Power Monitor Sensor Network Server KM-N2-FLK KM50-C-FLK KM50-E-FLK EQ00-E Large Easy-to-read Displays Many Host Communications Methods Multi-address System Measurement on the primary side of the inverter Measurement of minute electricity Pulse count for production and flow rate Various sensors such as electricity, air flow rate, pulse. analog, temperature/humidity, particles can be connected. Number of connectable sensors: 224 units (LAN: 00 units/rs-485: 24 units)

Our Further Proposals on Power Checkup Quality Strong Support for Construction of a Monitoring System Power is indicated based on CT(current) Energy Temperature and humidity Minute differential pressure Thermo-Humidity Station Differential Pressure Station visualize Extra Energy Particles For monitoring of the power of an entire building What you do is just connecting CT. There is no need for wiring for voltage measurement. 5F KM50 Battery-powered, Fixed by Magnet and Ultra-thin F ZN-CTX2 OPTION Environmental Visualization Software Machine ZN-SW-S KM50 This software is recommended for real-time display (monitoring) of waveforms. Air conditioners Lighting equipment External power source is not necessary. Easy to mount with the attached magnet. Air particle sensor, Dust measurement type LAN Air conditioners Lighting equipment 2F Air particle sensor, Particle measurement type Machine Environmental information + are displayed in synchronization on a real-time basis KM20 For example, this software synchronizes "cleanliness (environmental information)" and "electric power for a clean room" in the display on a real-time basis. in manufacturing areas of a device Machine A Machine B Machine C Temperature and humidity Changes in cleanliness in a device Ultra-easy Way of Logging Electricity A single button operation logs, in block, the data on 3 KM series units. You can collect data from SD card while sitting in your office. Data on 3 units of KM series for electric power monitoring can be logged, in block to the SD card. Logging starts with one push of a button. Using an FTP (File Transfer Protocol) tool in the marketplace enables you to import the data saved on the SD card to your PC over a network. Temperature and humidity Waveforms are automatically scrolled in a clean room Differential pressure inside and outside of a clean booth Changes in electric power Particles Differential pressure in a device in a clean room The single push of a button starts recording. Sum and value recorded on each KM are displayed Air flow Particles inside a clean booth in a clean room It displays environmental information and electric power on a layout drawing in the worksite in a manner that enables you to understand them at a glance. There are two types of displays. This display pops up when an alarm is detected Debut of a Smart and Easy to use! This Monior easily solves troubles for measuring power! This software supports linkage with various software products in the marketplace. Alarm output terminal LAN port SD card slot Thanks to the automatic transfer function in Excel and the mail transmission function when an alarm is generated, data administration and monitoring of a worksite are made easier. LAN Easily connected with the attached cable Up to 3 units are connectable in RS-485 communication The attached software easily enables graphic representation of the saved data. You can set the connected KMs at a time by use of the special tool. Dedicated software Easy KM Manager for KM series is used for setting KMs. For example, displaying "cleanliness" and "electric power of an air conditioner" synchronously and at the same time, you can identify excess energy in relation to the given quality control standard. Then,improving operation and enhancing control allows you to reduce extra energy while maintaining an optimum quality level.and since both quality and energy are visualized, the influence to the quality and the effect of electric-energy cut down is obvious. Before energy-saving measures Electricity for air conditioning Energy-saving Supporting Equipment for Monitoring System Compact Power Sensor Smart Power Monitor Sensor network controller KM20-B40-FLK KM50-C-FLK KM50-E-FLK EW700-M20L Measurement on the primary side of the inverter Measurement on the primary side of the inverter Downsized Measurement of minute electricity Less expensive Pulse count for production and flow rate Electricity for air conditioning Air conditioner output is controlled according to the environmental quality Connects KM units up to 24 Collects every sensor data including KM series Environmental particles Environmental particles Extra energy Alerts you by mail if an abnormality is detected Carry-in of products Clamp type CT After energy-saving measures Reduced energy Operates at a constant output Particles control standard Split type CT Real-time monitoring on the map display is also available Visualization of Extra Energy, a Blind Side in Energy Saving The same software as that for the ZN-CTX2 is attached. It provides graphic representation of the data saved on the SD card and PC with ease. Bar graph indication of instantaneous electricity is also available! Cleanliness is maintained at a high level until products are carried in. Particles level is still under the standard level after the air conditioner turns down.

List of specifications Ordering Information Logging unit Appearance Branch cable (cable length.3 m) Split type CT Connector: For connecting the branch cable Cable length: 0.2 m Clamp type CT Connector: For connecting the branch cable Cable length: 0.2 m Guideline for selecting dedicated CT unit Applicable circuits Single-phase 2-wire Single-phase 3-wire Three-phase 3-wire Three-phase 4-wire ZN-CTM-5A ZN-CTM-50A ZN-CTM-00A ZN-CTM-200A ZN-CTM5-200A Primary side rated current Secondary winding 5 A 50 A 00 A 3,000 turns 200 A 200 A Applicable frequency Insulation resistance Withstand voltage Protection element 0 Hz to 5 khz Between output terminal and case: 50 MΩ minimum (500 VDC megohms) Between output terminal and case: 2,000 VAC minute 7.5 V clamp element Allowable frequency of disconnection 00 times 5,000 times Applicable wire diameter * 7.9 mm dia. maximum 9.5 mm dia. maximum 4.5 mm dia. maximum 24.0 mm dia. maximum 23.0 mm dia. maximum Operating temperature and humidity range Storage temperature and humidity range Voltage of circuit used -20 C to +60 C 85% maximum (no condensation or icing) -30 C to +65 C 85% maximum (no condensation or icing) 480 VAC maximum * If you use a flat cable, select the cable based on the dimensions of the CT. Ordering Information Station unit Apperarance Station unit Product name Rating and performance Station unit Branch cable ZN-CTM-C * Up to three dedicated CTs for branch type are connectable to the branch cable.be sure, however, not to connect a CT of different rated current.correct measurement will be blocked. Connectable Power Sensor/Monitor Max. Number of Connectable Power Sensor/Monitor Units Display Recording Interval Recorded data Operation Function Recording Mode External Output Memory Capacity (Internal) Memory Capacity (External) Power Supply Logging unit Dedicated CT unit Branch type Product name ZN-CTX2-A -A Power supply Battery/DC cable Appearance Product name Dedicated CT unit (rating and performance) ZN-CTM-C ZN-CTM-5A ZN-CTM-50A ZN-CTM-00A ZN-CTM-200A ZN-CTM5-200A CT exclusive for branch type ZN-CTM-A ( * ) 2 2 3 (Necessary quantity is indicated in the table) Power supply DC cable -A KM50-C/E, KM00, KM20-B40-FLK, KM-N-FLK, KM-N2-FLK, KM-N3-FLK 3 units 7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays s, 2 s, 5 s, 0 s, 20 s, 30 s, min. Momentary power, Integrated power, Power factor, Sum of pulse input counts and 2 * Integrated power total sum, integrated momentary power, electricity rate total sum Continue mode*2, Ring mode *3 Alarm output (Photocoupler output) *4 Internal memory: approx. 200 data items (at maximum load); approx. 6800 data items *5 (at minimum load) SD card with SDHC compatibility *6 (Save measured values, save and read setting values) DC input: 24 VDC±0% Rating and performance Logging unit (rating) Connectable sensor Display Recording Interval Operation Function *2 Measurement Mode Recording Mode External Output Memory Capacity (Internal) Memory Capacity (External) Power Supply Current Consumption Battery Life *9 Operating Temperature Operating Humidity Storage Humidity/Temperature Insulation Resistance Withstand Voltage Vibration Resistance Shock Resistance Material Degree of Protection Mounting Weight (in Package) Accessories Logging unit (rating) Primary side rated current Primary side allowable input current Accuracy Measurement target frequency Recording values Applicable circuit * An error of the dedicated CT is not included. Current Consumption Operating Temperature Operating Humidity Storage Humidity/Temperature Insulation Resistance Withstand Voltage Vibration Resistance Shock Resistance Material Degree of Protection Mounting Weight (in Package) Accessories ZN-CTX2-A ZN-CTM - A 7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays s, 2 s, 5 s, 0 s, 20 s, 30 s, min. * Momentary power, Integrated power consumption Normal mode, Sleep mode *3, High-speed logging mode Continue mode*4, Ring mode*5 Alarm output (Photocoupler output) *6 Internal memory: approx. 6500 data items SD card with SDHC compatibility *7 (Save measured values and converted values; save and read setting values) DC input: 24 VDC ± 0%; Batteries: Two AAA batteries*8 80 ma max. Approx. week *0 Battery Supply: -0 C to +60 C (no condensation or icing) 20% to 85% (no condensation or icing) -5 C to +60 C, 20% to 85% (no condensation or icing) 20 MΩ (500 VDC) 000 VAC, 50/60 Hz, min.: Between the case and current input circuit With mounting screws: 0 to 50 Hz, 0.7 mm double amplitude, acceleration: 50 m/s 2 for each in X, Y and Z directions for 80 min. With mounting magnets: 0 to 55 Hz, 0.3 mm double amplitude, acceleration: 20 m/s 2 for each in X, Y and Z directions for 50 min. 50 m/s 2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each * ABS IP30 Magnet mounting, screw mounting, hook Approx. 500 g Instruction Sheet, Startup Guide, Mounting Magnets*2, Alarm Output Connector*3, DC Cable, and Ferrite Core *: In high-speed logging mode, data is recorded in 83 ms at 60 Hz and in 00 ms at 50 Hz. *2: Momentary power and integrated power values are converted from the measured current. Correctly specify the number of used channels, applicable measurement target circuit, CT type, frequency, voltage and power factor. *3: The display turns OFF after 0 seconds of no user operation and recovers by a key operation when SLEEP mode is specified. LAN cannot be used when sleep mode is specified. *4: Automatically writes the data to the SD memory card when the internal memory reaches its capacity and continues recording until the SD card memory capacity reaches its limit. The unit stops operation if there is no SD memory card inserted when the internal memory reaches its capacity. (Recording can be resumed after inserting an SD memory card and outputting the data to it at a press of button.) *5: Continues the recording of the latest measured values until the internal memory reaches its capacity. (If the internal memory capacity exceeds the capacity, data is overwritten from the oldest one in the memory.) *6: Output when the integrated power upper limit specified in THR mode is exceeded. An alarm output is not available in SLEEP mode. *7: An OMRON HMC-SD29 SD Memory Card or an SDHC Class 4 or higher memory card is recommended. *8: Nickel-metal hydride cells or alkaline dry cells can be used. Manganese battery cells cannot be used. *9: Battery life varies depending on the measurement environment, recording interval, operation mode as well as the battery type and performance. *0: Conditions: Two AAA nickel-metal hydride cells; Sleep mode; Continue mode; Recording interval: s; SD memory card: HMC-SD29; Operation temperature: 23 C ; and Automatic range selection off *: The installation place must be free from physical shock when using mounting magnets. *2: Already installed on the product by factory default. *3: OMRON's XW4B-02B-H connector. ZN-CTX2-A Dedicated CT (5 A/50 A/00 A/200 A) 20% of rated current (Continue) ±2.0%FS± digit (Ambient temperature 23 C, rated input, rated frequency) * 50 Hz/60 Hz Current value, instantaneous power, integrated power consumption Single phase two-wire, single phase three-wire, three-phase three-wire, three-phase four-wire -A 80 ma max. Without Ethernet: -0 C to 40 C (no condensation or icing) With Ethernet: 0 C to 40 C (no condensation or icing) 20% to 85% (no condensation or icing) -5 C to +60 C, 20% to 85% (no condensation or icing) 20 MΩ (500 VDC) 000 VAC, 50/60 Hz, min. 0 to 50 Hz, 0.7 mm double amplitude, acceleration: 50 m/s 2 for each in X, Y and Z directions for 80 min*7 50 m/s 2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each*7 ABS IP30 Magnet mounting, screw mounting, hook Approx. 500 g Instruction Sheet, Startup Guide, Alarm Output Connector*8, KM Dedicated Connection Cable(3 m), DC Cable, and Ferritecore. *: Only supported for KM50-C and KM50-E. *2: Automatically writes the data to the SD memory card when the internal memory reaches its capacity and continues recording until the SD card memory capacity reaches its limit. The unit stops operation if there is no SD memory card inserted when the internal memory reaches its capacity. (Recording can be resumed after inserting an SD memory card and outputting the data to it at a press of button.) *3: Continues the recording of the latest measured values until the internal memory reaches its capacity. (If the internal memory capacity exceeds the capacity, data is overwritten from the oldest one in the memory.) *4: Output when the integrated power upper limit specified in THR mode is exceeded. *5: The maximum load is applied when 3 KM50- units are connected; and the minimum load, when a single KM20-B40-FLK is connected. *6: An OMRON HMC-SD29 SD Memory Card or an SDHC Class 4 or higher memory card is recommended. *7: The vibration resistance when mounted using the ZN9-EM0-S magnets (separately sold): 0 to 55 Hz, 0.3mm double amplitude, acceleration: 20m/s 2 for each in X, Y and Z directions for 50 min. The installation place must be free from physical shock. *8: OMRON's XW4B-02B-H connector.

Optional Appearance Product name Mounting magnet (A set is attached to ZN-CTX2 and ZN-CTX2-A.) DC cable Straight type (2 m) (A magnet is attached to ZN-CTX2-A and -A.) Right angle type (2 m) ZN9-EM0-S ZN9-ED0-S ZN9-ED02-S Appearance Product name Special Cable (3 m) (One included with the or -A.) ZN9-KMC30 Special Cable (3 m) For direct connection to KM-N-series Power Monitor. Environmental Visualization Software * * 2 Wave Inspire ES ZN9-KMC30-N ZN-SW-S * Operating environment/os: Microsoft Windows 7 (32 bit/64 bit)/microsoft Windows 0 (32 bit/64 bit) CPU: Intel convertible processor GHz minimum Memory: GB minimum (2 GB or greater is recommended) *2 Supportable version is Ver. 2.2. or later. External dimensions (Unit: mm) Tolerance class IT6 applies to the dimensions unless otherwise specified. ZN-CTX2-A -A Screw hook hole Mounting screw hole 2-M3, 4 mm in depth Battery chamber* 7.2 Dedicated CT unit/ connection cable connector Power supply input terminal 49.4 48.6 2-M3 40 60 2-4 dia. Reset switch 24.6 0.7 56.8 Display Alarm output terminal MODE key Select key (upper direction) Select key (lower direction) SET/REC/STOP key 60±0.2 40 ZN-CTM-5A ZN-CTM-50A ZN-CTM-00A ZN-CTM-200A CT Hole Dimensions 0 R5 7.9 7.4 R8 5.57 CT internal diameter 0 dia. 40 25.3 33 39 CT Hole Dimensions 0 R5 9.5 8.5 40.5 25.5 R7.5 7.5 22.9 28.9 CT internal diameter 0 dia. 37.4 29.4 CT internal diameter 6 dia. 52.5 35.5 44.9 55.9 CT internal diameter 24 dia. 4.3 55 75.7 3 6 48 3 3 CT Hole Dimensions 6 R8 4.5 R9 4.2 46 30.5 CT Hole Dimensions 24 24 R0 R8 Standard length 0.2 m Standard length 0.2 m Standard length 0.2 m Standard length 0.2 m ZN-CTM5-200A 06 33 Outside diameter 47 dia. and internal diameter 23 dia. 23 Screw hook holes dimensions Mounting hole process dimensions LAN port SD card slot *The battery chamber does not open for. Standard length 0.2 m ZN-CTM-C Standard length.3 m Sensor head connector CT connector

N EW New-generation environmental sensor TM Series ZN-CTX2 (Logging unit) ZN- CTM (Dedicated CT unit) I do not want to stop the machine to just check power. Whene ver n eed ed, Do you have the concerns about power measurement? evel of electricity cons l e h um yt ptio ntif e ni d i mm n ca. worksite our at y ely iat ed yo u Easy and Quick "Checking Power" at the Worksite It's troublesome to install the measuring equipment, when you want to check power. It takes time to collect data. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. OMRON Corporation Tokyo, JAPAN Industrial Automation Company Authorized Distributor: Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-232 JD Hoofddorp The Netherlands Tel: (3)2356-8-300/Fax: (3)2356-8-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 6073-5302 U.S.A. Tel: () 847-843-7900/Fax: () 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 9967 Tel: (65) 6835-30/Fax: (65) 6835-27 OMRON (CHINA) CO., LTD. Room 22, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 20020, China Tel: (86) 2-5037-2222/Fax: (86) 2-5037-2200 Logging unit (actual size) OMRON Corporation 202 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_8 058 Printed in Japan Cat. No. E49-E-0 02 Now this Clamp Type is available For more information