Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

Similar documents
Schiller AT-10 plus Tango M2 Interface Notes

Burdick Quest Tango M2 Interface Notes

Pulse Biomedical QRS-Card Tango M2 Interface Notes

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Philips StressVue Tango M2 Interface Notes

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

Cardioline Cube Stress Tango M2 Interface Notes

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Mortara X-Scribe Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

Honeywell HomMed Wireless Scale Quick Reference Guide

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

Agilent 87075C Multiport Test Set Product Overview

Obtain Power Measurements of a DOCSIS Downstream Signal Using a Spectrum Analyzer

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

IMPORTANT! This instruction guide explains how to install your CCTV system.

R Series Quick Reference Guide

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

J6 User Manual. User Manual. Multi-Screen Splicing Processor J6. Xi an NovaStar Tech Co., Ltd. Rev1.0.1 NS

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Camera Setup Instructions

Activity P32: Variation of Light Intensity (Light Sensor)

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

APM CALIBRATION PROCEDURE Rev. A June 3, 2015

M5-H002. Multiview T-35. DVB-T to PAL / 5 channels on all TV s

V 2.0 RD-8. Setup Guide. Revised:

COPYRIGHT NOVEMBER-1998

Table of Contents. Versa TILE & Versa DRIVE D2 Quick Start Manual

YAMAHA 03D SERIAL AUDIO MIXER

Amino. Digital Television. Sun City & Hilton Head Island

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

PXL2760MW LED LCD Monitor

F24X DSK Setup and Tutorial

Absolute volume control is also possible with SP Controls option Audio Follow Video Preamplifer.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Cisco/Scientific Atlanta 330 & 430. HD Television. Sun City & Hilton Head Island. Q u i c k TELEPHONE TELEVISION INTERNET WIRELESS SECURITY

Gordian. Multifunctional Power Distributor / Conditioner. v1.3

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Audio Design Associates (ADA)

FT991 and WSJT-X setup Let s set up the FT991 first 1. Click the Menu/Setup button and set the following menu items to these: i. 029 = 38400bps ii.

R-1580A Microwave Downconverter. Product Brochure

Manual. Simrad IS80 Heading Repeater HR80. English

ASSEMBLY AND CALIBRATION

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

THE FROG SERIES OPERATING MANUAL

PXL2470MW LED LCD Monitor

Model KT 53 Cooling incubators with thermoelectric cooling

Common Spatial Patterns 3 class BCI V Copyright 2012 g.tec medical engineering GmbH

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

0.01 (amplitude) The amplitude at 0.01s from QRS loop (angle) The angle at 0.01s from QRS loop

Specifications LED Display Video Controller VX4. Xi an NovaStar Tech Co., Ltd. Rev1.0.4 NS

SHOWLINE SL NITRO 510 LED STROBE LUMINAIRE SPECIFICATIONS.

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Video Effects Processor - VSL 201

TABLE OF CONTENTS. Set Top Box USER MANUAL

RMS 8424S Quick Start

3-in 1- out DVI Switcher

Hardware & software Specifications

FEATURES GUIDE. One Network Experience

PLL2210MW LED Monitor

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

REMOTE DISPLAY WIRELESS DECODER MK II

Model KT 170 Cooling incubators with thermoelectric cooling

Game Show Physiology

2002 Martin Professional A/S, Denmark.

Data Pattern Generator DG2020A Data Sheet

SHOWLINE SL PAR 155 LED LUMINAIRE SPECIFICATIONS.

MN9320A. Optical Channel Drop Unit. Independent Test Access Tool for Comprehensive DWDM Measurements

22" Touchscreen LED Monitor USER'S GUIDE

Specifications LED Display Video Controller VX4S

In-process inspection: Inspector technology and concept

Modbus for SKF IMx and Analyst

DXP A0808 Quick Start

PLL2710W LED LCD Monitor

Common Spatial Patterns 2 class BCI V Copyright 2012 g.tec medical engineering GmbH

JD725A Cable and Antenna Analyzer - Dual Port

RF Solution for LED Display Screen

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

PL2410W LCD Monitor USER'S GUIDE.

J.M. Stewart Corporation 2201 Cantu Ct., Suite 218 Sarasota, FL Stewartsigns.com

Digital Video Wall Control Box

DXI SAC Software: Configuring a CCTV Switcher. Table of Contents

Installing the P80 Console Media Adapter

Four-way Return Optical Receiver Manual. Transmitter OP-OR124RJ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 1)

Guide For Setting Up Your Fortec Lifetime Ultra Receiver

Scan Converter Installation Guide

DIGITAL VIDEO RECORDING (DVR) SERVICES

SHOWLINE SL BAR 640 LINEAR WASH LUMINAIRE SPECIFICATIONS.

20,1 TFT. For VDC and touchscreen versions. Jakob Hatteland Display AS. : JH20T01M20-UserManual. Description: Internet release for customers.

SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL.

HSR-1 Digital Surveillance Recorder Preliminary

SHOWLINE SL PUNCHLITE 220 LED LUMINAIRE SPECIFICATIONS.

2 Connect your video source

Transcription:

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes To setup Tango M2 with your stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232 Cable used to communicate with your stress system. This cable enables the stress system to prompt Tango M2 when it needs a BP measurement, and allows the Tango M2 BP reading to be transferred to the stress system s display and reports. o Case 12, Case, 15, Case 16, and older Centra Systems SunTech Part Number = 91-0012-00 Connection Ends: Stress System Connection 25 pin male Tango M2 Connection 9 pin female o Newer Centra Systems SunTech Part Number = 91-0013-01 Connection Ends: Stress System Connection 9 pin female Tango M2 Connection 9 pin female Marquette Case 12, Case 15, Case 16, and Centra Tango M2 Interface Notes Page 1 of 6

ECG Trigger Cable provides the ECG signal from the stress system to the Tango M2. o SunTech Part Number = 91-0011-01 o Connection Ends: Stress System Connection BNC male Tango M2 Connection BNC male Tango M2 Monitor RS-232 Connection Part # 91-0012-00 or 91-0013-01 ECG Trigger Connection Part # 91-0011-01 2. Connect the RS-232 Cable For Case 12, Case, 15, Case 16, and older Centra Systems From: the RS-232 connection on the rear panel of the Tango M2. To: the 25 pin AX-2 RS-232 port on the back of the stress system. For newer Centra Systems From: the RS-232 connection on the rear panel of the Tango M2. To: the 9 pin AUX/RS-232 port on the back of the stress system. Marquette Case 12, Case 15, Case 16, and Centra Tango M2 Interface Notes Page 2 of 6

3. Connect the ECG Trigger Cable From: the BNC External ECG connection on the rear panel of the Tango M2. To: the Pulse 1 connection on the back of the stress system. *Note If Pulse 2 is open, follow the instructions in Step 4 below for replacing Pulse 1 with Pulse 2. Alternatively, you may use a splitter cable, SunTech Part Number = 91-0053-01. 4. Tango M2 Monitor Setup a. When the operating screen is displayed, press the SELECT button once. This will bring up the MAIN MENU screen. b. Using the UP or DOWN arrows, highlight MONITOR SET UP and press the SELECT button. c. Using the UP or DOWN arrows, highlight STRESS SYSTEM and press the SELECT button. d. Using the UP or DOWN arrows, scroll through the list until Case 12, Case 15, Case 16, or Centra is highlighted and press the SELECT button to confirm the choice. e. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. 5. Stress System Setup a. Turn on the Centra, and the main menu is displayed. b. Using the trim knob, choose EXERCISE. c. At the Exercise screen, choose EXERCISE TEST. d. At the Pre Test screen, select MORE. e. Select LOAD. f. Select TASK and this will display the TASK FILES screen. g. Select DESIGN, wait a few seconds, and the DESIGN MENU will be displayed. h. Select DESIGN SET-UP PARAMETERS and the SET UP SCREEN will be displayed. i. Select LOAD. j. Select TREADMILL 60 HZ. k. Select EDIT, turn the trim knob to CONTINUE, and press the knob. l. Turn the trim knob to CONTINUE and press the knob again. Repeat this three more times and you will be at OUTPUTS screen. m. Turn the trim knob to PULSE 1 and set to QRS; set the WIDTH to 50 msec; set BD DEV to MEI 1950. n. Turn the trim knob to CONTINUE and press the knob. o. Turn the trim knob to CONTINUE and press the knob again. p. Select SAVE and select DISK (not DISKETTE). Marquette Case 12, Case 15, Case 16, and Centra Tango M2 Interface Notes Page 3 of 6

q. The message, FILE NAME IN USE is displayed. Turn the trim knob to REPLACE and press the knob. You should now be back at the SET UP screen. r. Select RETURN. s. Select SYSTEM INITIALIZATION and press the trim knob. The message, Name of the set up file to be used when stress program is started: is displayed. t. Press the trim knob to SELECT SET UP FILE NAME. u. Select TREADMILL 60 MHZ and press the trim knob. v. The cursor will be at DEVICE TO INITIALIZE:DISK. Press the trim knob to select DISK and press the knob. Go to OK? And press the knob. Go to YES and press the knob again. w. At CONTINUE, press the knob. The system will save the set up and return to the DESIGN MENU. x. Select RETURN. After a few seconds, you will be back at the main test screen. To Check That All Was Saved: a. Press the trim knob and select WRITER. b. Select PRINT. c. Select SET-UP. The unit will now print out the system configuration. Review outputs to make sure the parameters are set as follows; Pulse 1 = QRS, 50 msec BP DEV = MEI 1950 Marquette Technical Support = 1.800.558.5120 FAQs for Tango M2 Q. The Tango M2 displays a Status Message. What does it mean and what do I do? A. See the elibrary within your Tango M2 for quick troubleshooting tips. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Status Messages. You can also look in the Tango M2 User Manual under the Status Messages & Alarms section for details on each Status Message and solution. Q. The Tango M2 monitor returns a result of 0/0 after blood pressure (BP) measurements. What do I need to do to get a BP reading? A. There are certain noisy conditions where the Tango M2 cannot accurately measure BP. When the Tango M2 encounters these situations, it returns a reading of 0/0. Microphone placement is critical for reliable operation of the Tango M2; there are many places to find cuff placement help. a. See the elibrary within your Tango M2 for quick cuff placement tutorials. You can find the elibrary under the Main Menu; select Monitor Setup E-Library Tutorials. b. Look in the Tango M2 User Manual under the Using Tango M2 during a Stress Test section for details on each type of cuff; the Orbit-K and the Single Patient Use (SPU) kit. c. Follow the instructions in the Cuff Tutorial (located on the SunTech Medical website under Support Customer Technical Support Video Tutorials) for correct microphone placement. Q. Can I use a heart rate or blood pressure simulator to test whether the Tango M2 is working correctly with my stress system? Marquette Case 12, Case 15, Case 16, and Centra Tango M2 Interface Notes Page 4 of 6

A. You cannot use a heart rate or blood pressure simulator to test whether the Tango M2 is working with your stress system. The Tango M2 monitor requires that the ECG signal and the Korotkoff sounds, collected by the microphone in the cuff, originate from the same source, meaning the patient. Q. How can I adjust the brightness of the Tango M2 display? A. You can adjust the contrast of the Tango M2 display by following these steps: 1. When the operating screen is displayed, press the SELECT button once. This will bring up the Main Menu screen. 2. Using the UP or DOWN arrows, highlight Monitor Setup and press the SELECT button. 3. Using the UP or DOWN arrows, highlight Brightness and press the SELECT button. 4. Using the UP or DOWN arrows, modify the contrast of the screen. When you are finished, and press the SELECT button to confirm the choice. 5. Using the UP or DOWN arrows, select EXIT twice to return to the operating screen. Q. How can I get MAP on my Tango M2? A. Register your Tango M2 Monitor online or through mail to receive MAP as a function on your Tango M2 monitor. Please note that due to FDA Regulations MAP is not available to the United States market. On the web go to SunTechMed.com Support Sales Support Product Registration Q. How do I clean the Orbit-K cuff after a stress test? A. You can do either of the following: 1. Use a medical grade mild disinfectant wipe on the cuff or spray a cleaning solution onto a cloth and wipe the cuff. Afterwards, lay flat or line dry. 2. Remove the bladder and microphone from the outer shell of the Orbit-K cuff. Machine wash the shell in warm water with a mild detergent (50-140 F or 10-60 C). Lay flat or line dry the cuff. Do not place the cuff in a dryer. Q. My Tango M2 displays a message, Please VERIFY CALIBRATION or Equipment Maintenance and Calibration Required. What do I do? A. Verification of Pressure Calibration is required every year to maintain the accuracy of the Tango M2 s BP readings. You will need to contact your local SunTech Medical Service Center for help. In addition, the following items will be needed to verify calibration. Equipment Required: 1. Calibrated electronic manometer or equivalent. 2. 500mL volume or the Orbit-K Adult Plus cuff wrapped around something that will not break or crush (no glass). 3. Hand Inflation Bulb with bleed valve. 4. Tubing, Tee pieces, and miscellaneous connectors or you can order the T-Tube Kit (SunTech Part # 98-0030-00). Marquette Case 12, Case 15, Case 16, and Centra Tango M2 Interface Notes Page 5 of 6

Service Centers: For customers in the Americas SunTech Medical, Inc. 507 Airport Boulevard Suite 117 Morrisville, NC 27560-8200 USA Phone: +1.919.654.2300 +1.800.421.8626 (toll free within US) Fax: +1.919.654.2301 Email: CustomerService@SunTechMed.com For customers in Europe, the Middle East, Africa, Asia, and the Pacific SunTech Medical, Ltd. Oakfield Industrial Estate Eynsham, Oxfordshire OX29 4TS UK England Phone: +44 (0) 1865.884.234 Fax: +44 (0) 1865.884.235 Email: CustomerService@SunTechMed.com Marquette Case 12, Case 15, Case 16, and Centra Tango M2 Interface Notes Page 6 of 6