ServicePlus S17R Series 2 User Operating Instructions

Similar documents
CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

ChannelPlus H17XL Series 2 User Operating Instructions

Electronic 7 User Operating Instructions

1 Channel Multi-Purpose Programmer User Instructions

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

7 Day Digital Programmer

ST9100C User Guide. Features

7 Day Digital Programmer 3 Channel Surface Mount

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Programmable Room Thermostat With RF

7 Day Digital Light Switch with Optional Dusk Start

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Comfort System T-32-P Universal Thermostat. Operation Manual

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Waterline Room Controller - Type WLCT3

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

TDDFM14 OWNER S MANUAL

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

Radio Thermostat Clock

ST625TX Digital Room Thermostat

WiFi Controlled Fused Spur Time Switch

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

16 Amp Electronic 24 Hour/7 Day Time Controller

Digital Economy Seven Programmer

Digital Time Switch. Installation & Operating Instructions

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

USER & ENGINEER INSTRUCTION MANUAL

7 Day Digital Time Switch

24Hour/7Day Electronic Timeswitch

User interface. Abbreviations / Meanings

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

Inserting the batteries. Basic settings of the remote control

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

EN Wireless programmable thermostat

2 Verify that the green light

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

[I] SELECTING ACTUAL TIME. )lf~ IMPORTANT: INSTALLER, Please leave this guide with the householder together with its Warranty card.

7 DAY DIGITAL LIGHTSWITCH WITH OPTIONAL DUSK START INSTALLATION & OPERATING. Cat No. ZV700 INSTRUCTIONS

1. General Information:

A digital version of this document is available to download and submit online at ADDRESS POST CODE

SceneStyle2 User Guide

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

Operating instructions. Universal timer switch display

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

Ducasa Digital Programmer

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

External RF programmable room thermostat 411

Operation Guide 6022 ENGLISH

XTM72 Exerciser Timer Module

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Aspect 2 Circuit Digital Scene Control

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

Installation & Programming Manual. Please read before using this timer.

Instructions Manual


User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Arduino Nixie Clock Classic Rev4 and Rev5 All In One Modular Rev2

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

Battery Operated Controllers

XTM72E & F Real-Time Clock Modules

Arduino Nixie Clock Modular Rev3

INSTRUCTION MANUAL COMMANDER BDH MIG

Instruction Manual for Programmable Digital Timer

DLP200M 2 Relay Module for Heating and Cooling Plants

Sample BD Tech Concepts LLC

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary... 5

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

Slimline Digital Electric Radiator. Step by Step Programming Guide

Master Time Clock MTC Users Manual

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

Electronic lubrication control unit

WELDING CONTROL UNIT: TE 450 USER MANUAL

INSTRUCTION MANUAL DLC400BP DIGITIAL LIGHTING CONTROLLER FOR TECHNICAL SUPPORT: USA

Philips LightMaster. KNX Timeclock Installation and Operation Manual

Operations. BCU Operator Display BMTW-SVU02C-EN

Arduino Nixie Clock Modular Rev3

Sample BD Tech Concepts LLC

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

Addendum: Rain Dial Installation and Programming Guide Update

--o.. tl. D NEXT ON/CfF Ct»V.[] D USER INSTRUCTIONS. + Simple change to 5 day/2 day mode ON. FP75-7 day programmer with separate outputs for

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

User Guide. Color Touchscreen Programmable Thermostat. ComfortSense Model: 13H /2017 Supersedes

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

SCENEMASTER 3F QUICK OPERATION

HD Digital Set-Top Box Quick Start Guide

Arduino Nixie Clock Classic Rev4 and Rev5 All In One

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Evolution Digital HD Set-Top Box Important Safety Instructions

T2210HD/T2210HDA 21.5 Wide-Screen LCD Monitor User Manual

SPIRIT. SPIRIT Attendant. Communications System. User s Guide. Lucent Technologies Bell Labs Innovations

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

Registers type ILR7XX and ILR7XXT

The smart valve with 3 Independent programs + 2 extra modes

Transcription:

ServicePlus S17R Series 2 User Operating Instructions Single Channel Timeswitch The Horstmann ServicePlus S17R timeswitch will allow up to 3 ON/ settings per 24 hours on a weekly schedule and has a 1 hour manual boost and advance button to temporarily override current settings. There is also a programming switch allowing permanent selection of: /ON// Additionally, the ServicePlus timeswitch gives an advance warning of the annual boiler safety check due date. 1

The ServicePlus S17R Timeswitch The simple instructions contained in this user guide are designed to help with the programming and operation of the unit. 1 14 15 2 16 10 3 11 12 13 9 4 5 6 7 8 1 SET indicator - RUN is the normal position 2 Time of day 3 Switch period symbol 4 SET button 5 BOOST or adjust (-) button 6 ADVANCE or adjust (+) button 7 button 8 SELECT or COPY button 9 System ON indicator 10 SET positions 11 PROGRAMME positions 12 BOOST symbol 13 ADVANCE symbol 14 AM/ symbol 15 Day of week indicator 16 PROGRAMME indicator 2

Manual Overrides BOOST FUNCTION - 1 hour temporary override The boost facility will allow the user to boost the system which is currently for 1 hour. To indicate the boost being activated BOOST will be shown on the display for the duration of the boost period. The system ON indicator will also be illuminated. Press BOOST button: Your system will be boosted for 1 hour At any time during a BOOST period press BOOST again to return to normal programming RUN CLOCK PROG BOOST Advance Function Brings forward the next on or off operation The advance facility will allow the user to advance the system to ON when currently or switch the system when currently ON. To indicate the advance feature being activated ADVANCE will be shown on the display until the next programme switching time. The system ON indicator will also be illuminated. Press ADVANCE button once to move to the next ON/ time To cancel the advance press the ADVANCE button again. This will return the unit to its normal programme RUN CLOCK PROG ADVANCE 3

Override Facilities With the ServicePlus S17R timeswitch operating in the normal running mode it is possible to alter the functionality of the programme by means of the SELECT button. The options include; Auto - Timeswitch follows all programmed ON and times. All day - Timeswitch operates from 1st ON time until 3rd, ignoring all switching times in between. 24hrs - Timeswitch will be constantly ON. Off - Timeswitch will be constantly, there is the ability to turn off the heating during the summer without altering the programme times. Boost is still available. All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user. The diagram below illustrates how to alter the setting, it assumes that the programme is in the mode to begin with. Press SELECT once. goes from to Press SELECT again. goes from to Press SELECT again. goes from to Press SELECT again. goes from to Timeswitch will operate from 1st ON until 3rd period Timeswitch will be continuously ON Timeswitch will be continuously will return to normal ON and times 4

Setting Time of Day and Date The ServicePlus S17R timeswitch has a built in clock and calendar. This will mean that you will need to enter the date as well as the time on initial set up or if the factory re-set has been used. Having done this, the clock will automatically adjust for BST/GMT time changes throughout the year. Press the set button until the set indicator is next to the clock position to adjust to adjust the to set to set the the hour minutes the date month to set the year Once the year is set and the button is pressed the process is complete and the display will return to the run position Check that the correct time and day are showing in the display. If the wrong day is showing in the display that would indicate that the date has not been set correctly and the above process should be repeated 5

Setting the On and Off Times To alter these settings please proceed as follows:- Press the SET button until SET indicator is next to PROG position Use PLUS and MINUS to adjust day Use PLUS and MINUS to adjust 1st ON time Use PLUS and MINUS to adjust 1st time Press Press Press Repeat this process for 2nd and 3rd settings Enter the 3rd time and the word COPY is displayed To follow the copy route and repeat all programmed times for another day go to 1 To set independent times for other days go to 2 1 PLUS and MINUS to select day required COPY. IN is displayed to confirm the copy. Repeat for other days as required To transfer to independent times for other days go to 2 or to finish programming press the SET button until the SET indicator is in the RUN position 2 Press. plus and minus to select the day required. Set 1st, 2nd and 3rd times as before. To repeat for other days go to 2, to copy go to 1 To finish programming press the SET button until the SET indicator is in the RUN position 6 Default Time settings 1st ON 1st 2nd ON 2nd 3rd ON 3rd 6.30AM 8.30AM 12.00 12.00 4.30 10.30 The default time settings shown above are preset at the factory NB. The factory default settings for the 2nd ON/ times are both set at 12:00pm (midday) which cancels this ON period giving 2 ON/ periods for the day. If a midday ON period is required set the 2nd ON and times accordingly. If not press twice.

Resetting the r Electronic equipment can in some circumstances be affected by electrical interference. If the programmer s display becomes frozen or scrambled; or if you wish to revert back to the default time settings please reset by pressing the SET and SELECT together as shown below. After initial installation it is advisable, before programming the ServicePlus for the first time, to reset the unit. Resetting can only be achieved with the power ON by pressing the SET and SELECT together. This will return the programmer to the factory set default times. Press the SET and SELECT together then release the and the programmer will return to preset factory settings SET SELECT General Information BATTERY The programmer is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank, after 3 days the current time of day will be lost. These measures are to prolong the battery life. SERVICE AND REPAIR This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide shown above. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician. 7

What is a programmer?... an explantion for householders. rs allow you to set On and Off time periods. Some models switch the central heating and domestic hot water on and off at the same time; while others allow the domestic hot water and heating to come on and go off at different times. Set the On and Off time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen On and Off heating periods, or be permanently off. The time on the programmer must be correct. Some types have to be adjusted in Spring and Autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, Override, Advance or Boost. These are explained in the manufacturer s instructions. The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature. The above explanation also applies to your timeswitch, which operates as a single circuit programmer. Email: sales@horstmann.co.uk Website: www.horstmann.co.uk Horstmann Controls Limited, Bristol BS4 1UP 8 Leaflet number P84353 Issue 1