GIMOTA AG. Assembly Instructions GTM12 Series

Similar documents
HARTING Ethernet cabling cables and connectors, 4 wire

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

M23 RJ 45 M23 Profinet M16 (10pole)

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Atari PICO Composite Mod Board Installation Instructions:

CANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR

DLMP Installation Instructions

Devices. Signal reception socket outlets - TECHNICAL CHARACTERISTICS C - Pouyet C - IBM, Reichle & De Massari

DLMP-45/45R Installation Instructions

Assembly instructions

TE Connectivity DEUTSCH DL Series MIL-DTL Series III Connectors

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

BNC 75 Ohm RF-Connectors

Assembly Instructions

C 303-RF Tri-element Array Microphone Instructions

3 Cleaning. 4 Technical data

SECTION 7 -- CROSS-CONNECT SYSTEMS

FISCHER MINIMAX TM SERIES

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Control cabinet interface and cable entry systems

Digital Modulator Instructions

Copyright Black Box Corporation. All rights reserved.

RAIL D-SUB BACKSHELLS

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

DIAS power supply and DIC 221 fibre optic cable coupling module

Building a MidiBox LCD Cable

Site Installation Model MP-8424

K-LWLH1 2.0 m AA. K-LWLH m AA. K-LWLH m AA

Site Installation Model MP-8433

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

IL591 SECTION D Rev /2011. Tek-SAFE NC150R Area of Rescue Assistance System. Operation, Installation and Service Manual

Ultra-Grip 2 Crimp Connector Hand Tool Kit for Coaxial Cable Connectors, Powerpole Connectors, Insulated and Non-Insulated Crimp Terminals

-V- New. Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

VOYAGE EVENT RECORDER VER4000/VER4000-S INSTALLATION MANUAL. Issue 03. June Spec No

Non Magnetic Connectors

A0304 A0304. Audio Out. Audio In. 15 VDC IR In. IR In A0304. Audio & IR Control CAT5 Transceiver

VITALink Taped Splice Straight Through Crimp

BNCpro for 3G and Ultra-HD/4K

Highlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors

Grounding-type plugs and sockets K Product information

Magic Patch Patch Leads & Accessories

What really changes with Category 6

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

LAMPHOLDERS FOR LOW-VOLTAGE HALOGEN LAMPS

3 SLiC Aerial Closure with Rubber End Seal

8341LS PRODUCT SPECIFICATIONS MODEL 8341LS LED BASEBALL SCOREBOARD OUTDOOR SCOREBOARD. Baseball 10-Inning Line Score

Main Products. Cable Assemblies Wire Harnesses Raw Cables. Connectors

Instructions. Cable with Armor F CAUTION. October Rev A

Multi-Media Installation Guide

Enterprise Networks. Comms Room and Backbone. in DETAIL

Table 4-1: Rating Levels

AB-114 / AB-202 AB-404 / AB-301 AB-T2454 Multi-room audio distribution system AB-202

Satellite Dish Installation Manual (Ver. 2) 1

Telemetry Receiver Installation Guide

3M Better Buried Closures

Ultra-Grip Crimp Connector Hand Tool Kit for Coaxial Cable and Powerpole Connectors

Connectivity for Ethernet

National Wire and Cable and National Cable Molding Headquarters Los Angeles California

FOSC 450 C6 and D6 Closures

Telemetry Receiver Installation Guide

Cables for robot applications

Cable and Connector Product and Installation Manual


ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

DM-TX-201-C DigitalMedia 8G+ Transmitter. Supplemental Guide Crestron Electronics, Inc.

Installation Overview

NEW. Datasheet. Field wiring Cabtite Easy Cable Entry System!

User Manual RTHDBT402PT & RTHDBT402PR

Volition TM RJ45 K5e Jacks

SUHNER QMA SUBMINIATURE CONNECTORS

Connecting cables for valves, Sub-D Type codes

Term 1 Grade 11 -Task Sheet 2. Group: N/A (Not Applicable) Finishing Time: Make a CAT5 cable. Picture 1. Picture 2

By CHANNEL VISION. Flush Mount Amplifier A0350

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles

LCS 2 RJ 45 Cat. 6A HD panels and units

TE Connectivity DEUTSCH ACT Series MIL-DTL Series III Composite Connectors

Leading Provider of Cable Management Solutions. M8 & M12 Cordsets & Accessories

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B

C 303W-RF Tri-element Array Microphone Instructions

HIGH SPEED MULTIPOLE CAT 6A CONNECTORS

Preventing Fieldbus Physical Layer Problems

CONNECT. Connecting all your devices effectively

btnet new products Modular and preloaded patch panels btnet

INSTALLATION GUIDE FOR THE MOTOR

TeamWork Installation Guide

In-Wall Control Mount for ipod Touch

Follow The Leader In Shielded Technology

Kramer Electronics, Ltd.

Electromechanical Relays

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

Replacing the PanelMate epro PS, PanelMate epro PS EE, and PanelMate epro PS OD 7685x-12 Series Backlight Assembly

AGRO. The Cable Glands.

KVT Split cable glands

PYROTENAX TERMINATION KITS COMMERCIAL WIRING. For Pyrotenax copper sheathed mineral insulated (MI) wiring cable

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

Instructions for WiP Relay Block Kit

Transcription:

GIMOTA AG Assembly Instructions GTM12 Series 2015

2015 Gimota AG, Chrummacherstrasse 3, 8954 Geroldswil, Switzerland. This Assembly instruction replaces all previous instructions. Product data are provided without guarantee and are for information only. All data are subjected to alteration. Valid from 05.2015 All rights reserved. Without permission from Gimota AG it is not permitted to reproduce this instruction or concerning extracts.

1 Installation Instructions GTM12 / GTB12 1.1 Assembling instruction GTM12- / GTB12-4 pole Push the coupling nut, cable gland and the screen contact spring onto the cable. [] Strip off the cable insulation sheath by 24 mm. Cut the metal shielding braid for 10-15 mm. [] Strip the wires to a length of 4.5-5.0 mm. The use of the GIMOTA wire stripper GIW ACK is recommended. [] bucket side. [] The use of the crimping tool GIW-AFM8 with the GIMOTA positioning adaptor GIW-AFM8-SK2/2 is recommended. Positioning adaptor dimension pin contact = 14.75mm W socket contact = 19.50 mm Selector W on GIW-AFM8 = 6 th position. Push adapter over the cable. [] shown below into the contact carrier (5) (Ethernet-standard). [] GTM12-D-4-MP / GTM12-D-4-FS / GTB12-D-4-MP Pin version Socket version Contact occupancy PNO - PROFInet ODVA - ETHERNET/IP Contact 1 TD+ yellow white-orange Contact 2 RD+ white white-green Contact 3 TD- orange orange Contact 4 RD- blue green (5) Insert the pre-assembled ethernet cable with the contact carrier - in compliance with the coding check mark (notch) - fully into the M12- front-module (6) and screw it on the adapter (*). [] Slide the screen contact spring on the cable shield up to the stop in the adapter. It is important to make sure that the feet of the screen contact spring standing firmly on the braided shield. [] Fully push the cable gland into the adapter, so that the feet of the screen contact spring come to lie under the cable gland and firmly press on the braided shield. to screw GIW DM12-MS14 the coupling nut to the adapter (*). (6) GTM12 Assembly Instructions Gimota AG 05/15 1

1.2 Assembling instruction GTM12-8 pole Push the coupling nut, cable gland and the screen contact spring onto the cable. [] Strip off the cable insulation sheath by 24 mm. Cut the metal shielding braid for 10-15 mm. [] Strip the wires to a length of 6.0-6.5 mm. The use of the GIMOTA wire stripper GIW ACK is recommended. [] bucket side. The use of the crimping tool GIW-AF8M with the GIMOTA positioning adaptor GIW-AF8M-SK2/2 is recommended. [] Positioning adaptor dimension = 15.25mm Selector W on GIW-AF8M = 6 th position. W Push adapter over the cable. [] shown below into the contact carrier (Ethernet-standard). [] 1 8 2 1 3 8 7 4 6 5 GTM12-A-8-MP Pin version, front view Contact Contact Contact 1 blue/white Contact 5 green/white Contact 2 brown/white Contact 6 orange/white Contact 3 brown Contact 7 blue Contact 4 orange Contact 8 green Insert the pre-assembled ethernet cable with the contact carrier - in compliance with the coding check mark (notch) - fully into the M12- front-module (5) and screw it on the adapter (*). [] (5) Slide the screen contact spring on the cable shield up to the stop in the adapter. It is important to make sure that the feet of the screen contact spring standing firmly on the braided shield. [] Fully push the cable gland into the adapter, so that the feet of the screen contact spring come to lie under the cable gland and firmly press on the braided shield. to screw the coupling nut to the adapter (*). 2 GTM12 Assembly Instructions Gimota AG 05/15

1.3 Assembling instruction GTM12- / GTB12-4 pole, 100 Push the coupling nut, cable gland and the screen contact spring onto the cable. [] Strip off the cable insulation sheath by 38 mm. Cut the metal shielding braid for 20 mm. [] Push the 100 angle adapter over the cable. Strip the wires to a length of 4.5-5.0 mm. The use of the GIMOTA wire stripper GIW ACK is recommended. [] bucket side. The use of the crimping tool GIW-AF8M with the GIMOTA positioning adaptor GIW-AF8M-SK2/2 is recommended. [] Positioning adaptor dimension pin contact = 14.75mm W socket contact = 19.50 mm Selector W on GIW-AF8M = 6 th position. shown below into the contact carrier (Ethernet-standard). [] Pin version Socket version GTM12-D-4-MP-100 / GTM12-D-4-FS-100 / GTB12-D-4-MP-100 Contact occupancy PNO - PROFInet ODVA - ETHERNET/IP Contact 1 TD+ yellow white-orange Contact 2 RD+ white white-green Contact 3 TD- orange orange Contact 4 RD- blue green Insert the pre-assembled Ethernet cable with the contact carrier - in compliance with the coding check mark (notch) completely into the M12 module (5).Screw the M12 module on the adapter with a spanner (max.2.5mm thickness) SW14. (*) The use of the GIMOTA spanner GIW DM12-MS14 is recommended. [] Slide the screen contact spring on the cable shield up to the stop in the adapter. It is important to make sure that the feet of the screen contact spring standing firmly on the braided shield. [] Fully push the cable gland into the adapter, so that the feet of the screen contact spring come to lie under the cable gland and firmly press on the braided shield. to screw GIW DM12-MS14 the coupling nut to the adapter (*). GTM12 Assembly Instructions Gimota AG 05/15 3

1.4 Assembling instruction GTM12-8 pole, 100 Push the coupling nut, cable gland and the screen contact spring onto the cable. [] Strip off the cable insulation sheath by 40 mm. Cut the metal shielding braid for 20 mm. [] Push the 100 angle adapter over the cable. Strip the wires to a length of 6.0-6.5 mm. The use of the GIMOTA wire stripper GIW ACK is recommended. [] bucket side. The use of the crimping tool GIW-AF8M with the GIMOTA positioning adaptor GIW-AF8M-SK2/2 is recommended. [] Positioning adaptor dimension = 15.25mm Selector W on GIW-AF8M = 6 th position. W shown below into the contact carrier (Ethernet-standard). [] 8 1 2 1 3 8 7 4 6 5 Pin version, front view GTM12-A-8-MP-100 Contact Kontakt Contact 1 blue/white Contact 5 green/white Contact 2 brown/white Contact 6 orange/white Contact 3 brown Contact 7 blue Contact 4 orange Contact 8 green Insert the pre-assembled Ethernet cable with the contact carrier - in compliance with the coding check mark (notch) completely into the M12 module (5).Screw the M12 module on the adapter with a spanner (max.2.5mm thickness) SW14. (*) The use of the GIMOTA spanner GIW DM12-MS14 is recommended. [] Slide the screen contact spring on the cable shield up to the stop in the adapter. It is important to make sure that the feet of the screen contact spring standing firmly on the braided shield. [] Fully push the cable gland into the adapter, so that the feet of the screen contact spring come to lie under the cable gland and firmly press on the braided shield. to screw the coupling nut to the adapter (*). 4 GTM12 Assembly Instructions Gimota AG 05/15

GIMOTA AG Chrummacherstrasse 3 CH-8954 Geroldswil Tel. +41 44 749 30 10 Fax +41 44 749 30 15 info@gimota.ch www.gimota.ch