Ultra flat Pool & Spa LED light OWNER S MANUAL Ultra flat shape wire VAC ON/OFF control NoAir PAR56 Retrofit
Table of contents Technical & General specifications Box contents Installation instructions Retrofit with PAR56 niche 6 color programs (only for lamps) Operation Wiring instructions Setup Wiring instructions Setup Troubleshooting Page Page 4 Page 5 Page 6 Page 7 Page 7 Page 8 Page 9 Page 0 page of
Technical specifications Reference Description Color Light output Power Nominal CCT PLS00 PLS00B Bulb + housing 575 lm 575 lm 5W 5W PLW00 PLW00B Bulb + housing 50 lm 50 lm 6 W 6 W PLS700 PLS700B Bulb + housing 450 lm 450 lm 5W 5W PLW700 PLW700B Bulb + housing 00 lm 00 lm 8W 8W PLS400B PLW400B 95 lm 850 lm W 9W PLW600 PLW600B Bulb + housing 00 lm 00 lm 9W 9W PLS600 PLS600B Bulb + housing 40 lm 40 lm 6W 6W Beam Angle Diameter Optic Nominal input Voltage Life time hrs Power factor For operation only with a safety isolation transformer 0 70 mm VAC > 5.000 h > 0,7 General specifications 4m non detacheable rubber cable included Maximum water temperature Ingress Protection Rate! Moonlight Pool lamps must be completely submerged into water during operation. Not doing so, will void warranty. +5 C (Lamps have to be kept out of ice zones) IP68 (measured at m) Optional: Stainless steel faceplate PZM70-RV-SS page of
Box contents Moonlight complete types: PLS00 PLW00 PLS700 PLW700 PLW600 PLS600 Moonlight types: PLS00B PLW00B PLS700B PLW700B PLS400B PLW400B PLW600B PLS600B page 4 of
Installation instructions No liner: Use gasket With liner: Use gaskets OR page 5 of
Retrofit with PAR56 niche 4 page 6 of
6 Color programs (only for lamps) 4 5 6 7 8 9 0 4 5 6 SUN WHITE RED GREEN BLUE GREEN-BLUE RED-GREEN BLUE-RED EVENING SEA EVENING RIVER RIVIERA NEUTRAL WHITE RAINBOW RIVER OF COLORS DISCO FOUR SEASONS PARTY warm white fixed color red fixed color green fixed color blue fixed color green-blue fixed color red-green fixed color blue-red slow animation red-blue slow animation red-green slow animation green-blue cold white slow animation blue-red-green program, followed by program 5 fast animation slow animation red-blue-green-violet fast animation Operation Synchronizing multiple lamps:. All lamps need to be connected to the same transformer. Turn the lamps ON for a few seconds. Turn them OFF for MINIMUM seconds, then switch back ON 4. Change the color times. Now they are synchronized Changing colors: Turn the lamps OFF and quickly back ON (max 0 sec OFF) Or use our optional remote controllers PL-REM(-60, -00). Memorizing the last color:. Select the desired color. Turn the lamps OFF for MINIMUM seconds. The chosen color has now been memorized page 7 of
Wiring instructions Setup Each lamp is connected to the transformer by a separate cable (Preferred for new installations) Max cable length 0VAC VAC 4m cable attached to lamp Separate cable (not included) Toroïdal transformer is preferred because of better efficiency MAX CABLE LENGTH BY CABLE SECTION LAMP TYPE,5 mm,5 mm 4,0 mm 6,0 mm VA TRANSFORMER (VAC) * PLS00(B) 70m 0m 80m 6 PLS400(B) 70m 0m 80m PLS600(B) PLS700(B) 60m 00m 60m 5 PLW00(B) 90m 50m 8 PLW400(B) 60m 00m 60m 6 PLW600(B) PLW700(B) 50m 85m 40m 0 * The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps. These cable lenghts are calculated with worst case voltage drops in the electrical wiring. page 8 of
Wiring instructions Setup All lamps are connected to the transformer via cable Max cable length 0VAC VAC JUNCTION BOX JUNCTION BOX 4m cable attached to lamp Separate cable (not included) Toroïdal transformer is preferred because of better efficiency LAMP TYPE PLS00(B) PLS400(B) QTY LAMPS 4 MAX CABLE LENGTH BY CABLE SECTION VA TRANSFORMER,5 mm 4,0 mm 6,0 mm 0,0 mm (VAC) * 0m 60m 5m 5m 80m 90m 60m 40m 40m 90m 65m 50m 0m 6 48 64 PLS700(B) PLW400(B) PLS600(B) 4 00m 50m 0m 5m 60m 80m 50m 40m 0m 80m 60m 0m 00m 5 50 75 00 PLW00(B) 4 50m 75m 50m 5m 0m 80m 60m 80m 0m 90m 50m 8 6 54 7 PLW700(B) PLW600(B) 4 85m 40m 5m 0m 40m 70m 45m 5m 00m 70m 50m 70m 0m 85m 0 60 90 0 * The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps. These cable lenghts are calculated with worst case voltage drops in the electrical wiring. page 9 of
Troubleshooting PROBLEM The Pool light is flickering or or lights up faint SOLUTION Check the output voltage at the transformer terminals. This voltage should be between VAC and VAC. Verify that the used transformer VA rating is sufficient for powering all connected lamps Verify if the cables that are used to connect the lamps to the transformer are correctly dimensioned (see tables p. 8-9) Check if there are no bad contacts or interruptions in the cables. Several pool lights in the pool show different color programs Make sure that all lamps are connected to the same VAC power line. Execute the synchronization procedure as explained on page 7. page 0 of
We, the undersigned, EC Declarations of Conformity Manufacturer: Address, City: Country: Propulsion Systems bvba Dooren 7, Merchtem BE- 785 Belgium Declaration the following apparatus: Product name: Model name: Used as: LED underwater Light Moonlight PLS00(B), PLS400(B), PLS700(B), PLW00(B), PLW400(B), PLW700(B) PLS600B, PLW600B Product description: and color LED lightings for swimming pools and similar applications. Conform with the essential requirements of the follow standards & directives: CE directives EU 94/0 EC 907/006 0/65/EU 004/08/EC 0/9/EU ECO Design REACH RoHS Electromagnetic Compatibility (EMC) WEEE waste electronic equipment Conformity with the following harmonised norms: EN60598- EN60598- - 8 EN5505 EN6457 EN6000- - / EN5049 EN 5058:0 General requirements and tests Luminaire Part : Luminaires for swimming pools & similar applications Emission Immunity Harmonics WEEE marking RoHS I hereby declare that the equipment above named has been designed to comply with the relevant sections of above referenced specifications. The unit complies with all applicable Essential Requirements of the Directives. Name: Marc Lamberts Position: GM Place: Brussegem, Belgium Date: /0/0 page of
Contact details Propulsion Systems bvba Dooren 7 785 Merchtem, Belgium Tel + 46 0 5 Fax + 706 59 60 www.propulsionsystems.be info@propulsionsystems.be 40-00-50 We reserve the rights to change all or part of the contents of this document without prior notice