Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

Similar documents
GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Mining and Petrochemical Fiber Optic Cables

FREEDM Loose Tube Interlocking Armored Cables

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

HI-DEX PRODUCT SET DATASHEET

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Industry solutions: Broadcast

Cable Installation Tips

Product Catalogue. Fibre Optic Cable

Cable Installation Tips

Game on! Plug n play. Plug and play with PryTerms our pre-terminated fibre optic cables. Read more

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Empowering businesses through innovative network solutions.

OPTICAL FIBRE CABLE NETWORK 2004/1

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

DIAMOND Fiber Optic Components

SPECIFICATION. Optical Fiber Cable

SECTION 4 TABLE OF CONTENTS

OPTICAL CABLE FIBER-LAN INDOOR

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

FIBRE OPTIC CABLE SOLUTIONS

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Mini-breakout & Mini-bundle cable. Riser cabling solution

INDUSTRY SOLUTIONS: MINING

The World Of Professional Fiber Optics. safe flexible reliable

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

LD Series High Performance Loose Tube Fiberoptic Cables

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Singlemode Patch Cords and Pigtails

Ø 1000 * 588 mm 50 kg

Micro duct Cable with HDPE Sheath for Installation by Blowing

SOLO ADSS Short-Span Cables, Fibers

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

Detailed Specifications & Technical Data

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Connectix Cabling Systems

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

Jacketed Fiber 900 µm. FC Ultra PC Blue boot represents ª 55 db reflectance. FC Angled PC. SC Ultra PC. SC Angled PC. LC Ultra PC.

LIIN-25 FO Pigtail FC (0.9mm)

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

D131x-apbpmslc TECHNICAL DATA. Fiber Optic Patch Cords Simplex LSZH. Description. Features & Benefits

Structured Cabling. Product Line Brochure

for FOSTEC INC. 1/ 15

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

TECHNICAL SPECIFICATION

Gear up for the future.

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

Empowering businesses through innovative network solutions.

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Seal Kits for BUDI Enclosures

Min Dynamic Bend mm. Min Static Bend mm. EF 008 Uni4 L STA LU FS. EF 008 Uni8 L STA LU FS. EF 008 Uni12 L STA LU FS. EF 008 Uni16 L STA LU FS

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

IP-LINX Fiber :: X-XXXX

Fiber Optic Patchcords & Cable Assemblies. Exclusive CD edition March 2006

NO MORE LOOSE ENDS PRE-TERMINATED FIBER CABLE: FAST. TESTED. READY TO GO (BBOX) BLACKBOX.COM/PRETERMFIBER

MPS Webinar Technical Series

Jumpers & Pigtails. Fiber Type OM1, OM3, OM4, 0S1/OS2. Polarity Correction SC and LC duplex clip allows for polarity correction

GATOR PATCH. The ultimate fiber distribution terminal

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER

PreCONNECT Mobile PRODUCT INFORMATION

Preferred ordering guide for NETCONNECT

LTX Optical Distribution Panels. Ordering Guide

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

IP-LINX. Installation Guide

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Fibre Optic Cable & Connector Guide

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Revision No. 4 Page No. Page 1 of 7

Number of Fiber 6 Core 12 Core. Part Number

Number of Fiber 12 Core 24 Core 48 Core. Part Number

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

SECTION FIBER OPTIC STATION CABLES

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor.

Compact Module. Category 6 FTP Cabling System

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Active Optical 4K HDR HDMI Cable

CATEGORY 5e CABLING SOLUTIONS

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

Transcription:

Page /7 Illustrations Product description Pre-terminated installation cables (VIK) are fiber optic cables with connectors on one or both ends that are made in manual singleitem production at METZ CONNECT in Blumberg by respecting highest quality demands. Combined with breakout cables (BO) they are suitable for indoor and outdoor use. VIKs are often used together with OpDAT patch panels (types PF, PA, fix, slide). They allow a rapid and easy to install point-to-point connection. Thus, installation time and cost are considerably reduced compared to an installation requiring splicing and pigtails or a cabling with different patch cords. Characteristics: Number of fibers: 2, 4, 6, 8, 2, 6 and 24 Pre-terminated with connector types LC, SC, ST and E2000 Available as cable coil or on wooden drum (depends on length and cable type) With or without pull-in aid 00% testing of insertion loss and return loss, delivered with measuring protocol Areas of use: Building backbone (floor cabling) Fiber-to-the-Desk Cabling in data centers

Page 2/7 Structure Fanout Bend protection Breakout cable Connector individual cable PG fixation kit (as an option) Label with serial number Pull-in lug Pull-in aid Breakout cables Breakout cables are designed for universal cabling systems. They are made of individual cables (dia. 2.0 mm) in one cable jacket. The individual cables are symmetrically grouped around a central element so that the cable always has a round cross section. The cables are UV resistant, flame retardant, halogene-free and metal-free, water-resistant and moisture resistant. Primarily they are designed to be laid in conduits and ducts in indoor areas; but for shorter distances they may also be used outdoors. All used optical fibers are bend insensitive. PG fixation kit The PG fixation kit is available as an option and is used to fix the VIK securely for example in a patch panel. When ordering the VIK with pull-in aid the PG cable gland is included in delivery.

Page 3/7 Structure Fanout Generally the fanout has always the same length. The length is 0,8 m from cable divider to end. The individual pre-terminated fanout cables are graded in length when pull-in aids are used, then the shortest length is about 50 cm. Fanout protections Bubble wrap If no other protection was defined the bubble wrap is always supplied as fanout protection. All fanout cables have the same length (about 0.8 m). Bubble wrap is a simple mechanical protection during transport and installation. The bubble wrap should not be used to pull the cable into cable ducts or conduits! Pull-in aid The pull-in aid is used to pull the cable into cable ducts or conduits. Mechanically it is the most resistant fanout protection: crush-resistant, available with protection class IP50 and easy to disassemble.

Page 4/7 Specifications up to 4 fibers up to 2 fibers up to 24 fibers Cable Cable type I-V(ZN)HH Color: OS2 = yellow, OM3= aqua, OM4= violet, OM5= lime green Cable structure (number of fibers) 4 2 24 Outer diameter 7.5 mm 2.5 mm 4.5 mm Cable weight 60 kg/km 60 kg/km 20 kg/km Min. bending radius (installation/operating) 75 mm / 30 mm 50 mm / 250 mm 75 mm / 280 mm Flame retardant according to IEC 60332--2 Fire behavior Halogene-free according to IEC 60754- Smoke density according to IEC 6034-2 Fixation Type of fixation PG3.5 PG6 PG2 Drilling for fixation 2.0 ± 0.2 mm 23.0 ± 0.2 mm 28.8 ± 0.2 mm Fanout Individual core 2.0 mm, tight buffered fiber Length if graded (with pull-in aid) Length if not graded (with bubble wrap) L Fmax 560 mm 6 fibers: 620 mm 8 fibers: 680 mm 2 fibers: 800 mm L Fmin 500 mm 500 mm 500 mm 800 mm Marking Numbered, = L Fmax Pull-in aid Max. outer diameter 37 mm Delivery Length L G to 40 m 4 to 40 m 4 to 650 m 6 fibers: 920 mm 24 fibers: 60 mm Cable coil, packed in foil and cardbox Drum dia. 600 mm, packed in cardbox Drum dia. 600 mm, packed in foil on pallets

Page 5/7 Dimensions Without PG cable gland Length Länge L G L G Length Länge L G With PG cable gland Length Länge L G Length Länge LL G

Page 6/7 Used fiber types MaxCap-BB-OM3 MaxCap-BB-OM4 WideCap-OM5 BendBright XS ISO/IEC 80 / EN 5073 OM3 OM4 OM5 OS2 IEC 60793-2 -0 A.a.2-0 A.a.3-0 A.a.4-50 B..3 und B6_b ITU-T G.657.A2, G.657.B2 G.65. G.65. G.65. and G.652.D Attenuation 850 nm 3,0 db/km 3,0 db/km 2,5 db/km - 300 nm,0 db/km,0 db/km 0,7 db/km - 30 bis 625 nm - - - 0,38 db/km Used connectors SC LC ST E2000 IEC 6754-4 6754-20 6754-2 6754-5 Insertion loss (against master) MM ) SM 2) Max. Typ. Max. Typ. 0.3 db 0.5 db 0.3 db 0.5 db 0.3 db 0.5 db Return loss MM PC polishing > 35 db > 35 db > 35 db > 35 db SM UPC polishing > 50 db > 50 db > 50 db > 50 db APC polishing > 65 db > 65 db - > 65 db ) IEC6300-3-4 method C that means the measured value is valid for both connectors without fiber attenuation 2) IEC6300-3-4 method B that means the measured value is valid for the individual connector without fiber attenuation Please note that the insertion loss of the OpDAT VIK consists of connector and fiber attenuation. With great lengths the fiber attenuation may be the main part of the insertion loss.

Page 7/7 Order information 9 = OS2 8 = OM5 7 = OM4 5 = OM3 = Bubble wrap on one end (for cable end B without connector) 2 = Bubble wrap on both ends 5 = Pull-in aid IP50 one end 6 = Pull-in aid IP50 both ends E = without G = with Breakout Fiber type Fanout protection PG fixation kit 52 B X X X X X X X X X X Number of fibers Cable end A and B Length L G 02 = 2 fibers 04 = 4 fibers 06 = 6 fibers 08 = 8 fibers 2 = 2 fibers 6 = 6 fibers 24 = 24 fibers Please note: These cables will be manufactured according to your specifications. They can therefore neither be exchanged nor returned. Technically, it is not possible to produce all possible combinations. Just use our cable configurator available on our web site at www.metz-connect.com/en/cable-configurator. There you can find all variants available. J = LC K = LC APC E = SC F = SC APC A = ST P = E2000 Q = E2000 APC 0 = without connector 00 = m... 650 = 650 m