arxiv: v1 [physics.ins-det] 2 Dec 2008

Similar documents
SciFi A Large Scintillating Fibre Tracker for LHCb

A new Scintillating Fibre Tracker for LHCb experiment

CAEN Tools for Discovery

SciFi A large Scintillating Fibre Tracker for LHCb

DEPFET Active Pixel Sensors for the ILC

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

An extreme high resolution Timing Counter for the MEG experiment Upgrade

Production and Development status of MPPC

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

TORCH a large-area detector for high resolution time-of-flight

Beam test of the QMB6 calibration board and HBU0 prototype

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Tests of Timing Properties of Silicon Photomultipliers

The ATLAS Pixel Detector

arxiv:hep-ex/ v1 27 Nov 2003

Solid State Photon-Counters

Application of Hamamatsu MPPC to T2K near neutrino detectors

PoS(PhotoDet 2012)018

FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD

THE ATLAS Inner Detector [2] is designed for precision

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode. R.Bellazzini - INFN Pisa. Vienna February

An extreme high resolution Timing Counter for the MEG Upgrade

The hybrid photon detectors for the LHCb-RICH counters

Silicon PhotoMultiplier Kits

The Silicon Pixel Detector (SPD) for the ALICE Experiment

Systematic study of innovative hygroscopic and non-hygroscopic crystals with SiPM array readout

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

ARDESIA: an X-ray Spectroscopy detection system for synchrotron experiments based on arrays of Silicon Drift Detectors.

arxiv: v1 [physics.ins-det] 1 Nov 2015

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Commissioning and Initial Performance of the Belle II itop PID Subdetector

A pixel chip for tracking in ALICE and particle identification in LHCb

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

LCOS-SLM (Liquid Crystal on Silicon - Spatial Light Modulator)

MPPC (multi-pixel photon counter)

Large photocathode 20-inch PMT testing methods for the JUNO experiment

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

Current status of Hamamatsu Si detectors mainly for High Energy Physics Experiments

Advances in multi-pixel Geiger mode APDs (Silicon Photomultipliers).

Sensors for precision timing HEP

The CALICE test beam programme

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

Small scintillating cells as the active elements in a digital hadron calorimeter for the e + e linear collider detector

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

SPATIAL LIGHT MODULATORS

3-D position sensitive CdZnTe gamma-ray spectrometers

Photon counting module

Note on the preliminary organisation for the design, fabrication and test of a prototype double-sided ladder equipped with MAPS

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

arxiv: v2 [physics.ins-det] 5 Feb 2018

Quick Report on Silicon G-APDs (a.k.a. Si-PM) studies. XIV SuperB General Meeting LNF - Frascati

HAPD and Electronics Updates

3 EXPERIMENTAL INVESTIGATIONS Caroline Robson. 3.1 Aims and Objectives. 3.2 Experimental Method Set Up of the Test Stand

CGEM-IT project update

Single-sided CZT strip detectors

li, o p a f th ed lv o v ti, N sca reb g s In tio, F, Z stitu e tests o e O v o d a eters sin u i P r th e d est sezio tefa ectro lity stem l su

A very brief review of recent SiPM developments

Status of the Timing Detector Plastic+SiPM Readout Option

Updates on the Central TOF System for the CLAS12 detector

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

A Large-Area Timing RPC

R&D of Scintillating Fibers for Intermediate Tracking and Bunch Id

Design of a Gaussian Filter for the J-PARC E-14 Collaboration

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

CMS Upgrade Activities

with Low Cost and Low Material Budget

A Cylindrical GEM Detector with Analog Readout for the BESIII Experiment. Gianluigi Cibinetto (INFN Ferrara) on behalf of the BESIIICGEM consortium

Riccardo Farinelli. Charge Centroid Feasibility

Single Photoelectron timing resolution of SiPM

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

Application of HDMI Cables as an MRI Compatible Single Cable Solution for Readout and Power Supply of SiPM Based PET Detectors

Prospect and Plan for IRS3B Readout

The field cage for a large TPC prototype

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

Terahertz focal plane arrays for astrophysics and remote sensing

Precision testing methods of Event Timer A032-ET

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

ASTROGAM Calorimeter: detector and FEE. Martino Marisaldi INAF IASF Bologna 1 st ASTROGAM Workshop, Roma Dec. 2013

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes

Performance of the MCP-PMT for the Belle II TOP counter

Review of the CMS muon detector system

Silicon Drift Detectors for the NLC

Focusing DIRC R&D. J. Va vra, SLAC

Advanced Front End Signal Processing Electronics for ATLAS CSC System: Status And Post Production Performance.

Sensors for the CMS High Granularity Calorimeter

Transcription:

arxiv:0812.0454v1 [physics.ins-det] 2 Dec 2008 A Scintillating Fiber Tracker With SiPM Readout G. Roper Yearwood a, B. Beischer a, Ch.-H. Chung a, Ph. v. Doetinchem a, H. Gast a, R. Greim a, T. Kirn a, S. Schael a, N. Zimmermann a, T. Nakada b, G. Ambrosi c, P. Azzarello c, R. Battiston cd, C. Piemonte e a I. Physikalisches Institut B, RWTH Aachen University, 52074 Aachen, Germany b Ecole Polytechnique Fédérale de Lausanne, Dorigny, CH-1015 Lausanne, Switzerland c Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, 06123 Perugia, Italy d Università degli Studi di Perugia, Dipt. di Fisica, 06123 Perugia, Italy e Fondazione Bruno Kessler - Istituto per la Ricerca Scientifica e tecnologica, 38050 Trento, Italy We present a prototype for the first tracking detector consisting of 250 µm thin scintillating fibers and silicon photomultiplier (SiPM) arrays. The detector has a modular design, each module consists of a mechanical support structure of 10 mm Rohacell foam between two 100 µm thin carbon fiber skins. Five layers of scintillating fibers are glued to both top and bottom of the support structure. SiPM arrays with a channel pitch of 250 µm are placed in front of the fibers. We show the results of the first module prototype using multiclad fibers of types Bicron BCF-20 and Kuraray SCSF-81M that were read out by novel 32-channel SiPM arrays from FBK-irst/INFN Perugia as well as 32-channel SiPM arrays produced by Hamamatsu. A spatial resolution of 88 µm ± 6 µm at an average yield of 10 detected photons per minimal ionizig particle has been achieved. Figure 1. One optical hybrid with 4 Hamamatsu MPPC 5883 SiPM arrays. 1. Tracker Module Prototypes A design for a modular charged-particle tracking-detector made up from scintillating fibers with silicon photomultiplier (SiPM) readout has been proposed for the PEBS balloonborne spectrometer[1]. Each module is built around a mechanical support from a 10 mm thick Rohacell foam layer contained between two 100 µm thin carbon fiber skins. Two ribbons made from round multi-clad scintillating fibers with a nominal diameter of 250 µm are glued to the mechanical support, one onto the top and one onto the bottom. Each ribbon consists of 5 layers of fibers. One layer consists of approximately 128 fibers which are placed with a nominal pitch of 275 µm. The fiber layers of a ribbon are staggered by half of the fiber pitch. The fiber ribbons are glued with a Stycast epoxy loaded with 20 % 33 %TiO 2 to prevent optical crosstalk between the fibers. Optical readout hybrids (Fig.1) consisting of four linear SiPM arrays on a PCB board are placed on top of the polished fiber ends on both sides of the fiber module. Each fiber is read out by a SiPM array on one end and either covered by a mirror on the other side. 1

2 Table 1 Tested Silicon Photomultiplier Arrays. Type PDE λ peak /nm DCR /khz act. area/mm 2 no. channels U bias /V Hamamatsu MPPC 5883 50% 450 200 8.0 1.1 32 71.0 FBK-irst 2007 25% 500 550 8.0 1.1 32 32.5 Table 2 Tested Scintillating Fibers. Type λ peak /nm /mm SCSF-81M[6] 437 0.230 ± 0.011 BCF-20[7] 492 0.241 ± 0.014 1.1. Silicon Photomultiplier Arrays Two types of SiPM arrays were available for testing (Tab.1). The Hamamatsu MPPC 5883[2] achieves a higher photon detection efficiency (PDE) at a lower dark count rate (DCR) compared to the FBK-irst 2007[3,4] due to its reduced number of pixels (80 pixels per channel for the MPPC 5883 compared to 110 pixels for the FBK-irst 2007) and a subsequently smaller relative dead area within the active area due to metallizations and quenching resistors[5]. The MPPC 5883 is covered by a 275 µm thick layer of optical glue. The FBK-irst 2007 comes without protective glue layer on top. 1.2. Module Production and Precision Two different types of fibers have been used during the production of the prototype modules (Tab.2). The thickness of the scintillating fibers is measured optically during the first step of the module production. The tested Bicron BCF-20 fibers are elliptic with an eccentricity of approximately ε = 0.5 while the Kuraray SCSF-81M fibers are round. The measured tolerances for the fiber diameter are approximately 15% of the mean diameter for both types of fibers. Five layers of fibers are wound onto a drum with a helical groove using a CNC winding machine. The drum has a diameter of 200 mm and the grooves have a pitch of 0.275 mm. Following the completion of each layer, an adhesive is applied to the fiber layer. After the adhesive has cured, the five fiber layers are cut and straightened out in order to obtain a 600 mm long fiber Figure 2. The test setup used during the beamtest 2008. ribbon. Two ribbons are glued to the module support and the fiber ends are polished. The precision of the fiber placement is determined using a regular image scanner to take a picture of the fiber ends. The SCSF-81M fiber ribbons show the better mechanical precision. The fibers within one layer are placed with a pitch of 275 µm and a precision (rms) of 19 µm. For the BCF-20 fiber ribbons a pitch of 273 µm and a precision of 37 µm were measured. The worse precision can be explained by the fact that the thickness of the BCF- 20 fiber frequently exceeds the groove pitch of the drum used to wind the fiber ribbon thus forcing other fibers within the ribbon into disarray. 2. Beamtest 2008 The first module prototype was tested with a 10 GeV secondary proton/pion beam at the T9 beam line of the PS accelerator at CERN. The testbeam setup (Fig.2) consisted of two trigger

3 counters, two spare double-sided silicon strip detectors from the AMS silicon tracker project[8] as a beam telescope and the fiber module prototype. The fiber module consisted of one SCSF-81M fiber ribbon and one BCF-20 fiber ribbon. Two optical hybrids were used during the beamtest to read out the fiber module prototype, one with four FBK-irst 2007 and another one with four MPPC 5883s. The MPPC 5883s were coupled directly to the fibers, for the FBK-irst 2007 a nominal air gap of 100 µm was left between fibers and SiPMs to prevent damage to the array surface. The beam telescope offered a spatial resolution of approximately 30 µm in the x-coordinate and 10 µm in the y-coordinate. The fiber module prototype could be rotated around the x-axis in order to simulate different angles of incidence. For the readout of the SiPM arrays, electrical hybrid boards based on the IDEAS VA32/75 readout chip[9] with 32 channels, a dynamic range of 36fC and a shaping time of 75 ns were developed. The gain of the SiPM arrays used is in the range of 10 6, therefore the SiPM signals had to be attenuated by a factor of 150 using a resistor network prior to sending them to the VA32 chip. The VA32/75 is compatible to the readout chip used for the AMS silicon tracker project so the same readout electronics required for the AMS silicon tracker was used to read out the optical hybrids[10]. 3. Test Results Single-track events with isolated hits in both Si strip detectors are selected offering the particle position in x and y in the fiber module (x p, y p ). From each of the SiPM array channels we have the amplitude u in ADC counts. The average position y f (x) of the fibers connected to one SiPM array channel with respect to the beam telescope is determined using the mean amplitude u(x p, y p ) averaged over all events which were recorded for one configuration. The straight line y f (x) = ax + y 0 that maximizes dx u (x, ax + y 0) gives the most probable fiber position. y f (x) is used to distinguish between the signal spectrum S(u) and the pure noise spectrum S d (u) of the SiPM array (Fig.3). The signal spectrum which depends on Figure 3. The noise spectrum and the signal spectrum for particle tracks near the measured SiPM channel position for one channel of a MPPC 5883. the gain G of the SiPM, the width σ 0 representing the electronic noise in the SiPM and readout chain, the variance of the gain σg 2, pedestal amplitude u 0 and the probability p(n) to measure n pixel discharges during one sampling is described by: S(u) = n=0 ( ) p(n) exp (u u n) 2 2πσn σn 2 where u n = u 0 + n G and σ n = σ0 2 + n σ2 G. The gain G and the pedestal position u 0 are determined from the signal spectrum. They are used to determine probability to see n fired pixels for the dark spectrum p d (n). Assuming that the number of random noise discharges n d during one sampling follows the poisson distribution Π(n), the mean number of noise pixel discharges n d is determined from Π(0) = p d (0). The pixel crosstalk probability ξ [11] which leads to a deviation of p d (n) from poisson statistics for n 1 is determined as ξ = 1 p d(1) Π(1). The MPPC 5883 had a much higher pixel crosstalk probability during the Beamtest at a lower DCR as shown in (Tab.3).

4 Table 3 Measured SiPM properties Type p d (0)/% ξ/% FBK-irst 2007 93 ± 2 7 ± 3 MPPC 5883 96.8 ± 0.6 32 ± 3 Figure 5. The average cluster amplitudefor 3 different SiPM arrays from the beam test against the y-coordinate for normal particle incidence. Figure 4. The mean shape of a signal cluster for a single MPPC 5883. as a seed for the signal cluster. Next all channels j with α(j) > 0.5 are recursively added to C if the neighbouring channel already belongs in C. To calculate the cluster amplitude A(C) which equals the number of detected photons, the pixel crosstalk and the limit on the dynamic range of each SiPM array channel imposed by the limited number of pixels N pix has to be corrected for. Using the 3.1. Light Yield The photon output of the scintillating fibers for a single particle track illuminates multiple SiPM array strips (Fig.4). The distribution of photons on the SiPM array is smeared because the fiber pitch does not match the array readout pitch and because of the optical gap between SiPM array and fiber (100 µm for the FBK-irst 2007 and 275 µm of optical glue for the MPPC 5883). Therefore signal clusters C were detected for each event and array selecting the channel i 1,.., 32 with the highest normalized amplitude α(i) = u(i) u0(i) G(i) Figure 6. The fitted track residuals for one MPPC 5883 reading out SCSF-81M fibers. channel amplitude corrected ( for the limited ) dynamic range α c (j) = N pix ln 1 α(j) N pix and the correction term for pixel crosstalk X = 1 ξ αc(j) 1 ξ gives us A(C) =. The average number j C α c(j) X of photoelectrons for normal incidence is 9.6 ± 1.2 for the combination MPPC 5883 and SCSF-81M, 5.3 ± 0.6 for the combination FBK-irst 2007 and SCSF-81M and 1.9 ± 0.2 for BCF-20 fibers read out by the FBK-irst 2007 (Fig.5). 3.2. Spatial Resolution The particle position from the fiber module y m is determined for all signal clusters C with a cluster amplitude A(C) > 0.5, the channel ampli-

5 array channels as well as smearing the position information carried by photons emitted by the scintillating fibers as has been studied by a dedicated Monte-Carlo simulation based on GEANT4[12] (Fig.7). These results indicate that a significant improvement in the spatial resolution is possible for the combination MPPC 5883/SCSF-81M if the thickness of the glue layer on top of the MPPC 5883 was reduced. 4. Conclusion Figure 7. The spatial resolution for the MPPC 5883/SCSF-81M prototype measured during the beamtest and the expected effect of reducing the thickness of the 0.275 µm thick glue layer according to Monte-Carlo simulations. tudes α c (i) of the channels i, the measured average position y f,i (x) of the fibers connected to the channel i and the x-coordinate of the particle x p from the beam telescope as: y m = i C α c(i)y f,i (x) A(C). The residuals y = y m y p (Fig.6) are then fitted with the sum of two Gaussians f( y ) = ( ) ( ) 2πσ1 c 1 exp 2 y + c2 2σ1 2 2πσ2 exp 2 y. The resulting rms of the distribution f is the spatial 2σ2 2 res- c1σ1 olution of ρ = 2+c2σ2 2 c 1+c 2. Based on a Monte- Carlo simulation, the contribution of the beam telescope and multiple scattering within the setup are calculated to be 38 µm which is dominated by multiple scattering. The resulting spatial resolutions are 88 µm±6 µm at an efficiency of ɛ = 0.99 for MPPC 5883/SCSF-81M and 110 µm ± 16 µm at an efficiency ɛ = 0.91 for FBK-irst 2007/SCSF- 81M subtracting the effect of the beam telescope. Tracks which are not passing in front of the central region of the SiPM array (Fig.5) are not considered for these results since in these cases part of the light signal is shared with neighbouring SiPM arrays. The gap between fiber and SiPM is suspected to play a role in optical crosstalk between SiPM The MPPC 5883 SiPM arrays and SCSF-81M fibers show the best overall performance among the tested components with a spatial resolution of 88 µm±6 µm and about 10 detected photons for a MIP. The SCSF-81M fiber offers better mechanical properties as well as the higher light output by almost a factor 3 compared to the tested BCF- 20 fiber. The primary cause of the worse spatial resolution and efficiency measured for the FBKirst 2007 is the lower number of detected photons compared to the MPPC 5883. This effect is due nearly a factor two lower geometrical fill factor of the FBK-irst arrays. A new array has been designed at FBK-irst in 2008 with two times higher filling factor, optimized for fiber tracking. The spatial resolution of the fiber module prototype can be improved by optimizing the coupling between SiPM and fiber. REFERENCES 1. H. Gast et al., NIM A, 581, pp. 151-155 (2007) 2. Hamamatsu Photonics K.K., Japan 3. C. Piemonte, NIM A, 568, pp. 224-232 (2006) 4. C. Piemonte, R. Battiston et al., IEEE Trans. Nucl. Sci. 54, pp. 236-244 (2007) 5. R. Greim et. al., these proceedings 6. Kuraray CO., LTD., Japan 7. Saint-Gobain Crystals, France 8. J. Alcaraz et al., NIM A 593, pp. 376-398 (2008) 9. IDEAS ASA, Norway 10. B. Alpat, NIM A, 439, pp. 53-64 (2000) 11. N. Otte, JINST TH 003 (2007) 12. S. Agostinelli et al., NIM A, 506, pp. 250-303 (2003)