IQ Analyzer 6400/6600 Series. Cutler-Hammer Power Management Products High End Metering Capabilities

Similar documents
MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

POWER MONITORS ENERIUM RANGE. Minimize your energy consumption and optimize your installation

We ve got the best technology to fit your power monitoring needs. Scenario works on all!

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Full Disclosure Monitoring

PowerLogic power-monitoring units

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

EC456 Power System Protection Lab #1 Overcurrent Protection Relay

User Manual Power and Harmonics Analyzer Model PQ3350

multi-function meters

User Manual. Power and Harmonics Analyzer Model PQ3350

Operating Instructions

SAPLING WIRED SYSTEM

DA E: Series of Narrowband or Wideband Distribution Amplifiers

BE3-GPR GENERATOR PROTECTIVE RELAY

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Certificate of Calibration

SINCE User Manual 7 DAY PROGRAMMABLE DIGITAL TIMER MODEL PS-100. The best solutions for automation and protection.

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Operating instructions Electronic preset counter Type series 717

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

PA9PLUS Portable Power Quality Analyzer

Application Note 11 - Totalization

Clamp 200 A AC/DC (+ V AC/DC + Ω)

SAPLING MASTER CLOCKS

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Modular Lube Lubrication Systems System Controls

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

SCALE & WEIGHT DISPLAYS

MULTIS L72. Operating instructions

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

D R M A X - 2 DDS FREQUENCY SYNTHESIZED DRM MW TRANSMITTER. User s Guide (Please read carefully before using for the first time!)

# Voltage Performance Monitor Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.

TED Pro Energy Monitoring and Control System

Advanced Test Equipment Rentals ATEC (2832)

Gamma instabus. Technical product information

Certificate of Calibration

LAUREL ELECTRONICS, INC.

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Selection Table. Ordering Information

Oscilloscopes for field applications

Electronic Pulse Counter Combination device

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

BUREAU OF ENERGY EFFICIENCY

Sapling Wired System. Synchronized Clock Systems

Ensemble QLAB. Stand-Alone, 1-4 Axes Piezo Motion Controller. Control 1 to 4 axes of piezo nanopositioning stages in open- or closed-loop operation

SINGLE ZONE CLIMATE ZONING SYSTEM. Technical Manual. Polyaire Pty Ltd

Sapling Wired System. The Sapling Company, Inc Republic Road Huntingdon Valley, PA P F

Automatic Transfer Switch Control PLC Operator s Manual

SMC 3000 Series Master Clock Installation Manual (V2) Table of Contents

HS-509 VIBRATION TRIP MODULE

Digital Input Modules for Compact FieldPoint

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

n Transient feature simulates voltage variations, brownouts and transient voltage conditions

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

M R X

SPECIFICATION NO Model 207 Automatic GTAW Welding System

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Process Transmitter RMA 422

Getting Started with the LabVIEW Sound and Vibration Toolkit

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

PRINCIPLES AND APPLICATIONS

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

HOBO H Energy Logger

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Digital output modules

ScopeMeter 190 Series Specifications

Intertie Protection M 3520

Re-defining the utility-scale inverter

PRODUCT MANUAL. Product Description. Waterproof 4 Channel DMX to RGB-W LED Controller

Generator protection relay

263 Series LED Bargraph Indicator and Controllers

Displays. 4.3 Digital TFT-LCD Module. 1. General Descriptions

A new generation of access control.

Inserting the batteries. Basic settings of the remote control

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

Series CT7N Bimetallic Overload Relays

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

GP-500 SERIES - Low Voltage

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Project Summary EPRI Program 1: Power Quality

Multifunction devices

Coherence Measurement between two Signals regarding Timing, Phase and Gain Application Note

G5-series AC Servo Drives with Built-in EtherCAT Communications Linear Motor Type

VIA 1.5 LED PENDANT DIRECT W W W. L U M E N W E R X. C O M

SAL Series Wireless Clock (V1)

Dissolved Oxygen Transmitter

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Manual PCE-830 power anlayser

ELECTRONIC HARMONICS METER RELAY

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

The DataView PowerPad III Control Panel

INSTRUCTION MANUAL POWER QUALITY ANALYZER

Work no. 2. Doru TURCAN - dr.ing. SKF Romania Gabriel KRAFT - dr.ing. SKF Romania

3124mb+ All Discrete 4 Channel Mic/Instrument Preamplifier with Stereo Mixer Operator s Manual

Transcription:

IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities

New IQ Analyzer Available May 2000 6400/6600 Series 2

Power Quality Monitoring Over 150 metered parameters for comprehensive diagnostics Assess trends, harmonics and waveforms to prevent process disruptions and equipment damage Isolate and diagnose power quality problems by analyzing historical metered data Control energy usage and costs via measurement, on-board data storage and time-of-use registers IQ Analyzer 3

Overview Revenue metering accuracy ANSI C12.16 ( 1% ) ANSI C12.20 ( 0.5% ) IEC 687 / Canada ( 0.5% ) Independent certification Time Of Use Registers Expanded event storage UL/CUL/CE (CSA applied for) New Display & Faceplate 4 Custom Display Screens 4

IQ Analyzer Key Features High-speed waveform capture Programmable event triggers 2 cycles @ 128 samples/cycle & 8 cycles @ 32 samples/cycle 11 channels of voltage & current information are saved Local display of waveform (6600 series only) Measures current and voltage through 50th harmonic Display harmonic spectrum on local display (6600 series only) 5

IQ Analyzer Key Features CBEMA/ITIC event display via PowerNet dv/dt trigger captures subcycle voltage disturbances (6600 series only) Communication flexibility: INCOM via IPONI Ethernet via EPONI & EPONIF RS-232 via RS232PONI Modbus via MPONI (Coming Soon!) 6

IQ Analyzer Key Features The IQ Analyzer stores 44 different minimum & maximum values including: Current Voltage Power Power Factor Frequency THD 7

IQ Analyzer Key Features On-board event data logging Auxiliary I/O capabilities Analog Outputs (3) 0-20mA/4-20mA 1% accuracy Analog Input (1) 0-20mA/4-20mA 1% accuracy Digital Inputs (3) optically isolated +30Vdc Digital Outputs (4) Form C contacts 10A @ 240Vac 8

IQ Analyzer Key Features Monitors L-L, L-N, L-G and N-G voltage PT ratios from 1:1 to 5,000:1 Monitors phase, neutral and ground current CT ratios from 5:5 to 10,000:5 Up to 40A continuous, 300A for 1 second Measures % Total Harmonic Distortion (THD) for current and voltage 9

New Features New Trending Capabilities 4 Independent trends Up to 6 parameters per trend Can chose from over 94 parameters Total of 90K bytes of storage Single parameter every 15 min. for 234 days Independent memory allocation for each trend Used with PowerNet for CBEMA/ITIC curve plotting utility 10

CBEMA Curve Utility 11

New Features New Trending Capabilities Sampling rate can be set from 8 cycles to 5040 minutes (3 1/2 days) Trend 1-3 can save data on a discrete input Trend 4 can save data on an event If the time period is set for an integer divisor of 60 the period starts at the next full hour. 12

New Features Data Logging Features Time & Reason for last 504 Events Any meter event is saved New Status Change Indicators Time of Alarms Power Up Resets Setting Changes INCOM Connection 13

New Features In addition to the data logging of the last 504 events last 10 Waveform Events are also stored The real time clock can be synchronized to the line to correct for long term errors (w/o PowerNet) Programmable CT Polarity Setting Change CT polarity from calibration menu Last event under Power Factor 14

New Features Time Of Use (TOU) Energy Registers 32 Schedules 8 Weekday - 8 Holiday 8 Saturday - 8 Seasons 8 Sunday Each schedule can change 9 times a day 4 Different utility rates Watt-hours, VAR-hours, VA-hours recorded 15

New Features TOU Demands Amps, Watts, VARS & VA 16

New Case Improvements Polycarbonate for higher durability & temperature Rugged outer edge Reset button changed from red to blue New Display Reverse mode, LED backlit LCD Yellow on black High reliability 17

Improvements Custom Screen Enhancements Allows programming of 7 parameters per screen Now 4 custom screens List of programmable items extended Clock Min/Max Values since last trend Magnitude THD (V and A) Displays each screen for 5 seconds 18

New IQ Analyzer Old IQA6000/6200 catalog numbers replaced with new 6400/6600 series IQA6410 - Separate Source PS IQA6420 - DC PS IQA6430 - Self Powered Three Phase PS IQA6610 - Separate Source PS w/waveform IQA6620 - DC PS w/waveform IQA6630 - Three Phase PS w/waveform 19

Support Material Instruction book changes to TD 17530B New Technical Data available TD.17.02A.T.E New Color Brochure available B.17C.01.S.E 20

Literature/Sales Tools/Getting Help www.ch.cutler-hammer.com/pmp Power Management Applications Support 800.809.2772 Power Management Sales Managers CHESS Power Automation Specialists Product Guide - PG.17.01A.T.E 21

Wrap UP Product Feedback PMPC Support Questions & Answers Thank You! 22