technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link

Similar documents
CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS

STRUCTURED CABLING SYSTEMS (SCS)

UC Copper / Fibre summary on USPs. Zoran Borcic, Axel Koplev

Volition TM RJ45 K5e Jacks

CATEGORY 5e CABLING SOLUTIONS

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

HARTING Ethernet cabling cables and connectors, 4 wire

Magic Patch Patch Leads & Accessories

Copper Solution Contents Cabinets Fiber Optic Solution

Class E A / Cat.6A Screened Coupler

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

PREMIUM 5e F/UTP PRODUCTS

Quickreference: Cat.6A EL / Class EA shielded. Horizontal floor cabling subsystem with shielded twisted pair technology

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

BTNS TM. FTP Compact Module

LCS2 Cat. 6 RJ 45 Patch panels and units

Quickreference: Cat.6 / Class E shielded. Horizontal floor cabling subsystem with shielded twisted pair technology

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

CAT5E NETWORK PATCH LEADS

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

LAN Cabling Systems Copper

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

C6 A modul and C6 A modul K. The new connection system for a wide variety of applications of course with Cat.6 A

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Table of Contents. Open Matrix System (OMS) 1-2

Quickreference: Cat.6A EL / Class EA unshielded. Horizontal floor cabling subsystem with unshielded twisted pair technology

TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)


CATALOGUE PRODUCT CATALOGUE CCS CONNECTIVITY & CABLING SYSTEM STRUCTURED CABLING SYSTEM. is a trademark of:

Volition TM Category 5e cable 100 Ω, FTP

C6Amodul and C6Amodul K. The connection system for a wide variety of applications of course with Cat.6A


What really changes with Category 6

Quickreference: Cat.6 A. unshielded. / Class E A. Horizontal floor cabling subsystem with unshielded twisted pair technology

PRODUCT INFORMATION. ETHERLINE EC Flex Cat.5e M8

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

Compact Module. Category 6 FTP Cabling System

Category 5e F/UTP Euroclass D ca Cables

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

LCS 2 RJ 45 Cat. 6A HD panels and units

Quickreference: Cat.6 / Class E unshielded. Horizontal floor cabling subsystem with unshielded twisted pair technology

btnet new products Modular and preloaded patch panels btnet

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

FUTURE PROOF YOUR CONNECTIONS

6-Connector- Channel-Link Class E A (STP)

TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

How to Implement PoE in Your Harsh Industrial Environment

SECTION TESTING OF COPPER CABLES

Belden IBDN System 10GX Enabling Technologies

Effective earthing of screened cables

DINTEK LAN Cabling Systems

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

Belden IBDN System 10GX The next level of cabling performance

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

Multi-Media Installation Guide

HDBT Installation Guide

Cat.6 4 Pair UTP Cable

Do you know if your Cat. 6 patch cord has been tested according to standards?

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

What Kind of Ethernet Cable Should I Use?

AMP CO Plus System Overview & Design Application Guide

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

PATCH CORDS, PLUGS & CABLES

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

GenSPEED Category 5e Cables 3

CAT5 VGA Extender. Mode 1 Mode 2

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Bus Cables & Industrial Ethernet Cables

Cabling systems for LAN Office, LAN Home, LAN Industry, Access/MAN/WAN networks, SAN. Competence in Cable Technology

Challenges for testing 10GBASE-T

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

Next Generation PoE Standards and Codes Update. Frank Straka Panduit Corporation

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

European Product Catalog2009 AMP NETCONNECT Building Networks

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

SECTION COMMUNICATIONS HORIZONTAL CABLING

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

HELLERMANNTYTON DESCRIPTION DIMENSIONS PKG. PART NO. (HXWXD) QTY. RE18 Residential Enclosure Base: 18 H x 14.1 W x 4 D 1 Cover: 19.5 H x 15.

Telegärtner AMJ Shielded 10 Gigabit Ethernet System

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

Preferred ordering guide for NETCONNECT

384A Adapter Installation Instructions

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Continuous Flex Data Cable

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

BUS UNITRONIC BUS CAN

SECTION 7 -- CROSS-CONNECT SYSTEMS

HDBaseT Installation Guide

Transcription:

technicalreport Data communication technology 09/2018 Classic structure 2-connector link Ethernet transmission with twisted pair cables Limiting factors for links > 100 m Example structure of a 2-connector link > 100 m Summary Data Communication & Networks LEONI Kerpen GmbH Zweifaller Strasse 275 287 52224 Stolberg Germany Phone +49 2402 17-1 Fax +49 2402 75154 MegaLine Connect100 Class E A links over 100 metres in length Anyone who has ever been confronted with Class E A links >100 m in the channel will be familiar with the problem of attenuation, pair cross talk and signal distribution speed. Since the length of a link is no longer an exclusion criterion for measurements, links > 100 m can now be measured as PASS. In order to achieve optimum success, care should be taken to ensure to use the right components. Otherwise the process can quickly result in frustration and additional costs. In addition, long links should be carefully planned and their usefulness assessed. The pages that follow describe the feasibility of an extra-long link and look at why the choice of the right components is absolutely critical datacom@leoni.com Subject to technical changes without notice. LEONI Kerpen GmbH LEONI technicalreport 09/2018 1

technicalreport MegaLine Connect100 Classic structure 2-connector link Patch bay / patch panel Wall outlet Horizontal cable Patch cords/ patch cables Permanent Link 5 m 90 m 5 m Patch bay horizontal cable wall outlet Channel 100 m Patch cord patch bay horizontal cable wall outlet connecting cable Connection cable Definition of a channel: 5 m patch cord/patch cable 90 m horizontal cable 5 m patch cord/patch cable Plug and jack components according to IEC 60603-7 or RJ45 (Registered Jack 45) Ethernet transmission via twisted pairs STANDARDS EIA/TIA 568 (USA) ISO/IEC 11801 (International) EN 50173 (Europe) IEEE 802.3 EIA / EUR 568 ISO / IEC 11801- EN 50173 Bandwidth Application Cat. 5 Cat. 5 Class D < 100 MHz 100Base HS Cat. 5e Cat. 5e Class D < 100 MHz 1000Base / T Cat. 6 Cat. 6 Class E < 250 MHz 1000Base / T Cat. 6A Cat. 6 A > Class EA < 500 MHz 10GBase / T Cat. 7 Class F < 600 MHz 10GBase / T Cat. 7 A > Class FA < 1,000 MHz 10GBase / T Cat. 8 > Class G < 2,000 MHz 25/40GBase-T Cat. 8.1 Class G 2,000 MHz 25/40GBase-T Cat. 8.2 Class G 2,000 MHz 25/40GBase-T UNSHIELDED In Europe, unshielded cables are generally used for structured cabling up to Category 6. When installing cables on cable trays, a larger distance from neighbouring cables has to be observed due to the lack of shielding. Typical signs of unshielded cables: separation of the wire pairs by means of a plastic cross and close twisting of the wire pairs. The main aim here is to suppress pair crosstalk of the signals, which can cause transmission disruption (NEXT / FEXT). The lack of shielding means these cables are easy to strip and assemble. What is more, the cables can be used in buildings with an older electrical installation, even if the earthing is not clearly identifiable. SHIELDED Shielded cables are mainly used in Europe for structured cabling from Category 6+ upwards. The shielding is available in various types. In Europe, both the individual wire pairs are shielded (by means of foil shielding) as well as all four wire pairs together (by 2 LEONI technicalreport 09/2018

technicalreport MegaLine Connect100 UNSHIELDED SHIELDED Overall shielding Conductor Conductor Conductor Bare copper wire, AWG 23/1 PE Pair 4 pairs separated by a cross element Conductor Bare copper wire, AWG 23/1 PE Pair 4 pairs with foil shielding PVC / LSZH Overall shielding Tinned copper braid PVC / LSZH means of foil shielding or braided shielding). As a result of this cable structure, cable designs currently exist which support a frequency of 2,000 MHz. The shielded cables also meet the requirements of the new Categories 8, 8.1 and 8.2. Pair crosstalk (NEXT / FEXT) of the signals is suppressed by means of wire pair shielding. The entire shielding suppresses crosstalk between different cables installed at a short spacing from one another. This allows these cables to be organised on cable trays in greater packing density. Typical features of these cables are the low level of twisting of the wire pairs and the support for frequencies from 300+ MHz, as well as high-quality connectivity. These cables are given preference in new buildings, office areas and data centres. Cat. 6A U/UTP Cat. 6A U/FTP Cable types compared Cat. 7 S/FTP Maximum class EA EA F FA Pair shielding Overall shielding Cat. 7A S/FTP Type Wire diameter in AWG 23 23 23 22 Type Frequency [MHz] 550 600 1000 1500 Type NEXT at 500 MHz [db] 29 61 97 105 Type Signal distribution speed [%] of light speed (NVP) 65 80 80 80 Max. DC resistance / 100 m 8 8 7.5 5.7 Standard Coupling attenuation up to 1000 MHz n/a 65 85 90 LEONI technicalreport 09/2018 3

technicalreport MegaLine Connect100 Limiting factors for links > 100 m of the wire pairs (twisted pair) The twisting of the wire pairs can mean that the propagation delay differs according to the cable design. Because of this, certification by class might involve the permitted propagation delay being exceeded. This will limit the possible link length in the channel. Cables with less twisting enable longer link lengths than heavily twisted cables. Cable attenuation Signal strength decreases along the length of the link. Cables with a small wire cross-section attenuate the signal more than those with a large cross-section. In the same way, cables with close twisting of the wire pair exhibit a higher level of signal attenuation than cables with less intense twisting of the wire pairs. Cable crosstalk (AXT Alien X-Talk or Alien Crosstalk) Just as individual wire pairs can influence each other inside the cable, individual cables can also impact on each other. Here again, as with wire crosstalk, shielded cables have higher performance reserves and frequency ranges. S/FTP cables offer the best performance figures. As a result, these are given preference as a construction product for a diverse range of installations. Connectivity A link is only as good as its weakest component. Connectivity of a low category or quality may prevent a potentially better result. They normally compensate the signals too strongly so as to allow longer links > 100 m. The best performance figures here are to be found in Category 7 A components. Crosstalk between the wires or wire pairs Cross talks are interference signals between the different wires or wire pairs. If the interference signals are too strong, signal transmission may be disrupted and the connection may be lost. An attempt to suppress this can be made by using unshielded cables with increased twisting of the individual wires and wire pairs, though here it is only possible achieve frequencies of 500 MHz max. For higher frequency ranges, the cable has to exhibit shielding of the wire pairs (PIMF Pair In Metal Foil) and also overall shielding (foil, braided). One exception here is the Cat. 8 cables according to the EIA/TIA standard, which build on Category 6A-F/UTP cable designs and are specified up to 2,000 MHz. However, this reduces the potential link length for Class G applications to 30 m. Assembly Imprecise or incorrect assembly of cable components impairs signal quality. The better the components are assembled on the cable, the better the signal quality. Manufacturer specifications and installation instructions must be observed at all times. When measurements are carried out to detect various transmission classes, e.g. Class E A, it is important to ensure good levels for crosstalk, insertion loss and wiring resistance. High levels (db) for crosstalk and insertion loss, low and even figures (Ω) for wiring resistance. 4 LEONI technicalreport 09/2018

technicalreport MegaLine Connect100 Example structure of a 2-connector link > 100 m Patch bay / patch panel Wall outlet Horizontal cable Patch cords/ Patch cables Permanent Link 2 m 116 m 2 m Patch bay horizontal cable wall outlet Channel 120 m Patch cord patch bay horizontal cable wall outlet connecting cable Connection cables Definition of a channel: 2 m patch cord/patch cable 116 m horizontal cable 2 m patch cord/patch cable Components used: 116 m horizontal cable LEONI MegaLine G12-150 S/F Category 7 A, Class F A Wire diameter AWG22, 1500 MHz Horizontal cable with assembled modules: fitted at both ends with ARJ45 jack modules from the LEONI MegaLine Connect100 system Category 7 A, Class F A, electrical performance figures as for IEC 60603-7-71 2 m patch cable as hybrid cable ARJ45 RJ45 LEONI MegaLine Patch 6 A E A ARJ45 -RJ45 Category 6 A, Class E A Summary AWG 22 Category 7 A / 8 components PoE / 4PPoE (PoE++) Link length > 100 m thereby saving intermediate distributors In order to ensure longer links >100, it is important to use highquality products wherever possible. Shielded Category 7 A cables with a high frequency range and shielding allow links of a total length of up to 120 m (channel link) with high-quality 7 A components. No satisfactory result was achieved with standard Category 6 A components, since compensation of the components was too high and the performance reserves were lacking. Collapsed backbone applications for incorporating additional connectivity and wireless LAN access points can best be realised using components of Category 7 A, Class FA. Both cables and components are standardised and available on the market, giving users maximum flexibility. This simplifies the use of connection points with PoE, PoE+, 4PPoE (PoE++). Planners and users can save costs by doing without intermediate distributors, while also doing away with additional weak points and manipulation points. LEONI technicalreport 09/2018 5