REVERSUS/ REVERSUS ENT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving UNIT A A A

Similar documents
Roof-mounted Blue e+ cooling unit Integration solution VX25

ALPAN W Compact DTV Transmitters 3-4U 19 HE DIGITAL ANALOG

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

Model KT 53 Cooling incubators with thermoelectric cooling

Product Data Sheet 4656 ZW

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

EVF 300 series. Controllers for electric bread and pizza ovens, with touch-keys, in split version and which can be integrated into the unit.

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

Product Data Sheet 8506 VW-691

Küba comfort DP. Draught-free ventilation and extremely quiet operation

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Product Data Sheet 4656 EZ

An impressive appearance

TUC: Universal thermostat

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

MIKRO POWER FACTOR CORRECTION COMPONENTS

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

Owner's Manual. TOUCH SCREEN CONTROLLER for Air Conditioning Control System. Model BMS-CT5120UL. English

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KBF 115 Constant climate chambers with large temperature / humidity range

A3H series. Energy and cost efficient solutions for the most demanding applications. Multi-stage. Roots pumps

Data Sheet - DARWIN temperature controllers

Swiveling unit. Smooth and precise swiveling

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

NEW SWIVELING UNIT RSP-FLEX. Smooth and precise swiveling

Forced Convection Laboratory Ovens

ErP ROOF UNITS - ROOFMASTER STOF VERTICAL FEATURES ELECTRICAL SUPPLY AMBIENT TEMPERATURE RANGE SIZES MATERIAL AND DESIGN

ECOLINE UM 045 UMP 045 UMPC 045 Oil service simple, quick and compact with integrated particle monitor

KRF EMC Filters Installation, Operation and Maintenance Manual

MS2540 Current Loop Receiver with RS485 Communication

Model KT 115 Cooling incubators with thermoelectric cooling

ANTHEM NOW SHIPPING MRX 710 AND MRX 510 A/V RECEIVERS No trade offs: high-end performance with ease of integration.

Model ED 23 Drying and heating chambers Classic.Line with natural convection

New output class 1600 W

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

ED5229GT-E Series. Page 1 of 8

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

Küba compact DF. The space-saving helper in filling stations, gastronomy and the trade

Duo 65 C, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Air cooled Outdoor installation R-410A Hermetic Scroll Ice protection system FREE-COOLING HydroPack ECOBreeze Electronic expansion valve

ED5229GT-E/GTRE Series

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Model KBF 720 Constant climate chambers with large temperature / humidity range

SAUTER flexotron RDT405 Manual

SoliTherm. Control Cabinet Air Conditioning....wegweisend innovativ

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

NH/NV8600 UHF Transmitter Family

Analogue HD Monitoring Set: 8-Channel Video Recorder + 4 Outdoor Cameras

Product Data Sheet 4650 N-465

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

ULTRALOW TEMPERATURE FREEZERS -86 C

TOSHIBA Industrial Magnetron E3328

49 inch Full HD 3.5mm Ultra- Narrow Bezel 24/7 Tiling Support with DisplayPort or DVI video wall Commercial Display CDX4952 Ultra-narrow Bezel

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

Model KT 170 Cooling incubators with thermoelectric cooling

EEEEE MOOVI EEEEE EEEEE EEEEE EEEEE MOOVI. Product. PLUS TECHNICAL FEATURES ACCESSORIES DISCOVER U-LINK

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Product catalogue 2010

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

THALNA. 600W Air Cooled DTV Transmitters HE UHF 1HPA

ROOF FANS RANGE INDUSTRIAL VENTILATION NEW

User Manual RTHDBT402PT & RTHDBT402PR

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

llen-bradley 194R-HM4-NFPA3

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

Programat P310. Economical firing performance. Top-quality results. The user-friendly furnace. Now with new OSD display

HDBaseT Extender Set 100m User Guide

intro Automation for swing gates with leaves up to 4 m Kg, undergroung installation

Agilent High Capacity RV Pumps & Roots Pumping Systems

PROPORTIONAL VALVES Sentronic plus

E-VENT. The turnkey plasma cutting machine. Technica l progress in the design

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

GPON EDFA with WDM for IP(OLT) Wavelengths Multiple Optical Outputs

MAGNETOSTICTIVE TRANSDUCER

PLEASE READ THIS PRODUCT MANUAL CAREFULLY BEFORE USING THIS PRODUCT.

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Series 3000 Dual Cast Transmitter

M R X

Philips CoralCare FAQ

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Features. Specifications. Finish. Notes

Catalogue Ignitors and power switches for HID

Systems and components for industrial enclosures. Edition 2018/1

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Transcription:

indoor air quality and energy saving TECHNICL DT UNIT CTR8-PH + sonda CO /VOC/U.R. 2 CTR8-PH + sonda CO 2/VOC/U.R. UNIT ENTLPICO ENTLPICO CONTROL CLSS CONTROL CLSS + sonda CO 2/VOC/U.R. B + sonda CO /VOC/U.R. 2 B B + B C D E F G REVERSUS/ REVERSUS ENT HET RECOVERY VENTILTION UNITS for RESIDENTIL BUILDINGS

REVERSUS Residential ventilator unit with dual flow and high yield heat recovery. PERFORMNCE Equipped with a counter current heat exchanger in thermoplastic material (polystyrene) and electronic backward blade ventilators. The total bypass as standard allows favourable climatic conditions to be taken advantage of outside the building for free cooling (or free heating) in automatic mode. STRUCTURE REVERSUS is manufactured using a self-supporting structure in 23 mm thick sandwich panels, insulated in polyurethane foam. The external t part of the structure is manufactured in plastofilmed sheet metal in grey, while the internal part is in luzinc, material that ensures high resistance against corrosion. Inside, REVERSUS is in expanded polypropylene, material that ensures a high level of thermal insulation between air flows. The access to filters (F7 for the renewed air flow and G4 for the extraction air flow) is particularly easy thanks to the two specific openings on the front panel. REVERSUS, is also available in enthalpy version. Is prepared for installation inside buildings with an ambient temperature between C and 45 C. It can be installed on a wall with connections for renewal air and expulsion on the upper part; for connections to supply and extraction ducts, you can choose to use the connections available on the top or bottom of REVERSUS (or both). CONTROLS REVERUSUS was supplied with an electric box and control system; it is available in a version equipped with EVO-PH control and a version equipped with EVOD-PH-IP control prepared for complete integration in home automation systems (Modbus protocol with Ethernet connection or, on request, with the addition of connection RS485). The new version of our control systems enables extremely easy and rapid passage from a control system to another, even after installation with the single replacement of the remote panel. The EVO-PH control has a coloured, backlit touch screen interface with intuitive viewing of the working status of the machine. It enables precise adjustment of ventilator speed and has a weekly, time schedule for automatic management of the ventilators. It can be controlled by an external switch to activate the booster function, it can automatically adjust the air flow rate if connected to an air quality probe, it can manage any air post treatment accessories, it automatically manages the bypass and prevents heat exchanger freezing by managing the speed of the ventilators or, if installed, an electrical pre-heating resistor (optional accessory outside the machine); it signals to the user the need to replace the filters (the clogging status of the filters is monitored by a pair of different pressure switches, supplied as standard) or an anomaly, indicating the origin. With the addition of optional accessories (COP kit and CV kit installed on the channel) you can manage the ventilation machine in constant pressure or constant flow rate mode. The EVOD-PH-IP control has the same characteristics as the EVO-PH version with the addition of Modbus communication protocol which allows full control of the machine by the supervision software of the home automation system. The implemented webserver allows interaction with the machine, even with an internet browser of a device connected (even from remote) to the home automation system in which the machine is inserted. For a more complete view of the characteristics of the control panels, please read the specific manuals 2

PERFORMNCES (UNI EN 13141-7) The unit must be ducted properly: UTEK authorizes the use only according to its performance diagram shown into this catalogue The claimed performances are guaranteed only by UTEK original filter low pressure loss Pressure Power Serie1 Nominale Ref Serie6 Serie8 Ref P Pressure [Pa] ir flow Portata (m3/s)[m 3 /s],,2,4,6,8, 7 6 5 4 3 2 2 18 16 14 12 8 6 4 2 Power [W] 5 15 2 25 3 35 4 ir flow Portata (m3/h) [m 3 /h] Pressure Power Serie5 Ref Reference Serie2 P Ref Serie8 Serie4 Pressure [Pa] ir flow [m³/s],,2,4,6,8,,12 8 7 6 5 4 3 2 4 35 3 25 2 15 5 Power [W] 5 15 2 25 3 35 4 45 5 ir flow [m³/h] 3

Pressure PERFORMNCES (UNI EN 13141-7) The unit must be ducted properly: UTEK authorizes the use only according to its performance diagram shown into this catalogue The claimed performances are guaranteed only by UTEK original filter low pressure loss REVERSUS ENTHLPIC 1 Power Serie1 Ref Serie5 Serie6 Serie8 Ref P Pressure [Pa] ir flow Portata [m³/s] [m 3 /s],,2,4,6,8, 7 6 5 4 3 2 2 18 16 14 12 8 6 4 2 Power [W] 5 15 2 25 3 35 4 ir flow [m³/h] 3 /h] REVERSUS ENTHLPIC 2 Pressure Power Serie5 Ref P Nominale Ref P ir flow [m³/s] Pressure [Pa],,2,4,6,8,,12 8 7 6 5 4 3 2 4 35 3 25 2 15 5 Power [W] 5 15 2 25 3 35 4 45 5 ir flow [m³/h] 4

HET RECOVERY PERFORMNCE (sensible efficiency) Values refered to the following conditions(uni EN 13141-7): Tbs external air 5 C; U.R. esternal 72%; Tbs enviorment 2 C; U.R. enviorment 28% REVERSUS REVERSUS ENTHLPIC Efficiency % ir flow [m³/s],,2,4,6,8,1,12,14 97 94 91 88 85 82 79 5 15 2 25 3 35 4 45 5 ir flow [m 3 /h] 5

TEST LEKGE /ENTHLPIC LEKGE OUTDOOR INDOOR INDOOR LEKGE OUTDOOR OUTDOOR INDOOR TEST CONDITIONS Positive pressure 25 Pa Negative pressure 25 Pa Pressure difference Pa TEST LEKGE /ENTHLPIC TEST CONDITIONS Positive pressure 25 Pa Negative pressure 25 Pa Pressure difference Pa CLSS 1 1 1 CLSS 2 2 2 NOISE LEVEL REVERSUS/REVERSUS ENTHLPIC Lw Sound power level taken in accordance to UNI EN ISO 3447 /ENTHLPIC Fans MX REF NOISE FROM THE CSE (db) 125 Hz 25 Hz 5 Hz Hz 2 Hz 4 Hz 59,6 65,6 64, 55,3 5,1 45,5 54,2 61, 54,7 46,9 41,1 35,5 8 Hz 49,4 39,3 L db() w 63,7 56, /ENTHLPIC NOISE IN THE DUCTS (db) Fans 125 Hz 25 Hz 5 Hz Hz 2 Hz 4 Hz 8 Hz L db() w MX 52,6 66,2 63,8 56,1 53,5 53,1 63,7 66,5 REF 47,7 6,7 56,7 47,4 43,7 42,4 46,7 57,2 /ENTHLPIC Fans MX REF NOISE FROM THE CSE (db) 125 Hz 25 Hz 5 Hz Hz 2 Hz 4 Hz 59,2 59,2 66,8 59,8 59, 49,1 51,3 59,4 56,9 51,9 5,5 39,5 8 Hz 37,6 28,1 L db() w 66,5 58,5 /ENTHLPIC NOISE IN THE DUCTS (db) Fans 125 Hz 25 Hz 5 Hz Hz 2 Hz 4 Hz 8 Hz L db() w MX 61,5 63,4 69,8 65,9 64,3 56,8 5,8 71, REF 54,1 6,1 6,8 57,1 56,4 48,3 42,1 62,8 ELECTRICL DT MTCHING FN UNIT REVERSUS/ENTHLPIC Power** Supply Current max. Insulation class Supply Current max. /ENT 2 X 85W 23 V, 5/6 Hz 1F 2 X,75 IP 54 classe 23 V, 5 Hz 1F 1,6 /ENT 2 X 17W 23 V, 5/6 Hz 1F 2 X 1,65 IP 54 classe 23 V, 5 Hz 1F 3,5 ** Fan data, it s referred to the global absorbed power graph of the machine in the working point 6

72 36 13 718 13 15 DIMENSIONS (mm) WEIGHT (kg) Weight Reversus 1 : 43 kg Weight Reversus 2 : 45 kg Weight Reversus enthalpic 1 : 48,28 kg Weight Reversus enthalpic 2 : 5,28 kg 13 33 Ø15 12 5 767 Ø1/2"gas 288 13 13 INSTLLTION REVERSUS/ENTHLPIC WLL INSTLLTION imum required space for maintenance (mm) 77 5 7

INSTLLTION REVERSUS/ENTHLPIC STNDRD SIPHON 185 Ø 26 95 Ø 32 VLUES CCORDING REGULTION (UE) N. 1253/214 MODEL MX IR FLOW [m³/s] REF IR FLOW [m³/s] REF PRESSURE [Pa] SPI [W/(m³/h)] LEKGE MX CONTROL CONTROL FCTOR SEC [kw h/(m².a)],91,63 5,294 4,% (external) 4,% (internal) CTR8-PH 1 (manual control) -73,7 (cold) -35,7 (average) -11,3 (hot),95 (clock control) -75, (cold) -36,8 (average) -12,3 (hot) + probe CO2 /VOC/U.R.,85 (central demand control) -77,4 (cold) -38,8 (average) -14,1 (hot),128,96 5,334 2,6% (external) 2,6% (internal) CTR8-PH 1 (manual control) -69,6 (cold) -33, (average) -9,4 (hot) + probe CO2 /VOC/U.R.,95 (clock control),85 (central demand control) -71,1 (cold) -34,3 (average) -1,5 (hot) -74, (cold) -36,7 (average) -12,6 (hot) VLUES CCORDING REGULTION (UE) N. 1253/214 MODEL MX IR FLOW [m³/s] REF IR FLOW [m³/s] REF PRESSURE [Pa] SPI [W/(m³/h)] LEKGE MX CONTROL CONTROL FCTOR SEC [kw h/(m².a)] ENTLPICO,96,67 5,39 3,7% (external) 3,7% (internal),95 (clock control) -74,2 (cold) -36,2 (average) -11,8 (hot) + probe CO2 /VOC/U.R.,85 (central demand control) -76,6 (cold) -38,3 (average) -13,7 (hot) ENTLPICO,126,88 5,453 2,8% (esterno) 2,8% (interno) + probe CO2 /VOC/U.R.,95 (clock control),85 (central demand control) -67,7 (cold) -3,9 (average) -7,2 (hot) -71,3 (cold) -33,9 (average) -9,9 (hot) 7

Dear Customer Thanks for your attention to the product UTEK, designed and manufactured to ensure the real values to the User : Quality, Safety and Savings on working. UTEK S.r.l. Made in italy UTEK reserves the right to at any time the necessary changes to improve products without prior notice. the Dealer REVERSUS/REVERSUS ENTHLPIC_216_2_EN HET RECOVERY VENTILTION UNITS for RESIDENTIL BUILDINGS UTEK S.r.l. Via Provinciale,3 233 Mazzo di Valtellina (So) Italy Tel.+39 342 86231 Fax +39 342 86229 www.utek-air.it utek@utek.it