400GBASE-SR16 Cabling

Similar documents
TECHN. Purpose. Background. to prepare the. A A Patch cord. horizontal infrastructure

500 m SMF Objective Baseline Proposal

MPO Technology Connectivity & Application

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

40G SWDM4 MSA Technical Specifications Optical Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications

Connectix Cabling Systems

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

100G-FR and 100G-LR Technical Specifications

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

10GBASE-LRM Interoperability & Technical Feasibility Report

400G-FR4 Technical Specification

Improved extinction ratio specifications. Piers Dawe Mellanox

Keyed LC Connector Solution A LANscape Solutions Product

802.3bj FEC Overview and Status. PCS, FEC and PMA Sublayer Baseline Proposal DRAFT. IEEE P802.3ck

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

Thoughts on 25G cable/host configurations. Mike Dudek QLogic. 11/18/14 Presented to 25GE architecture ad hoc 11/19/14.

DATA CENTER OPTICAL ASSEMBLIES TO SUPPORT QSFP, CFP AND CXP INDUSTRY STANDARD PINOUT CONFIGURATIONS

Arista 40G Cabling and Transceivers: Q&A

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

Comparison of options for 40 Gb/s PMD for 10 km duplex SMF and recommendations

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

50GbE and NG 100GbE Logic Baseline Proposal

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

40GBd QSFP+ SR4 Transceiver

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

ULTRA HIGH DENSITY SOLUTION GUIDE

100G SR4 TxVEC - TDP Update (D2.1 comment 94) John Petrilla: Avago Technologies March 2014

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

Empowering businesses through innovative network solutions.

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

40/100 Gb ETHERNET CABLING - A PERFECT STORM?

802.3bj FEC Overview and Status. 400GbE PCS Baseline Proposal DRAFT. IEEE P802.3bs 400 Gb/s Ethernet Task Force

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

Proposal for 400GE Optical PMD for 2km SMF Objective based on 4 x 100G PAM4

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

MPS Webinar Technical Series

100G PSM4 & RS(528, 514, 7, 10) FEC. John Petrilla: Avago Technologies September 2012

o-microgigacn Data Sheet Revision Channel Optical Transceiver Module Part Number: Module: FPD-010R008-0E Patch Cord: FOC-CC****

100G QSFP28 SR4 Transceiver

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

SECTION 4 TABLE OF CONTENTS

TP1a mask, noise and jitter for SRn

Product Specification 40BASE-SR4 QSFP+ Gen3 Optical Transceiver Module FTL410QE3C

QuickNet Fiber Cabling in the Data Center

Jacketed Fiber 900 µm. FC Ultra PC Blue boot represents ª 55 db reflectance. FC Angled PC. SC Ultra PC. SC Angled PC. LC Ultra PC.

Product Specification 40BASE-SR4 100m QSFP+ Gen2 Optical Transceiver Module FTL410QE2C

Ali Ghiasi. Nov 8, 2011 IEEE GNGOPTX Study Group Atlanta

Performance Methodology and Characterization of a Multi-Fiber Expanded Beam Lensed Optical Interconnect

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

IEEE P802.3bs D Gb/s & 400 Gb/s Ethernet 2nd Working Group recirculation ballot comments

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

HI-DEX PRODUCT SET DATASHEET

Meeting Notes Sept 23, 2012 IEEE Industry Connections HSE Consensus Ad Hoc

CAUI-4 Application Requirements

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

Opti Max Nodes Digital Return System

100GBASE-FR2, -LR2 Baseline Proposal

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

Stretch More Out of Your Data Centre s Multimode Cabling System

Optimax Field Installable Connectors and Installation Tool Kits

CATEGORY 6A CABLING SOLUTIONS

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Baseline proposal update

Installation. Step 1 Carefully unpack the package contents.

Everything you always wanted to know about HDBaseT*

Datasheet: MultiFiber Pro

CATEGORY 6A CABLING SOLUTIONS

IEEE P802.3bs D Gb/s & 400 Gb/s Ethernet Initial Working Group ballot comments

Product Specification 56Gbps 60/100m QSFP+ Optical Transceiver Module FTL414QB2C APPLICATIONS

The need for Encircled Flux, real or imaginary?

UHD System ULTRA HIGH-DENSITY RACK-MOUNT FIBER CONNECTIVITY SYSTEM

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

Development of optical transmission module for access networks

DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES

SYSTIMAX Solutions InstaPATCH 360 Pre-Terminated Fiber Solution Guide

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

PAM8 Baseline Proposal

Challenges for testing 10GBASE-T

Mar11 Rev E

PMD & MDIO. Jan 11, Irvine, CA. Jonathan Thatcher, Clay Hudgins, IEEE 802.3ae. 10 Gigabit Ethernet

MOST - Roadmap Physical Layer & Connectivity from 150Mbps to 5Gbps

Maps of OMA, TDP and mean power. Piers Dawe Mellanox Technologies

FEC Architectural Considerations

PHORCE (standalone version)

MT Connect Pre-Terminated Fibre Cabling Systems

HDBaseT in AV Systems: 7 Basics for Successful Deployment. Dan Underbrink, RCDD Principal Applications Engineer Leviton Network Solutions

802.3bj FEC Overview and Status IEEE P802.3bm

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Fiber Optics Redefined

Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

IEEE P802.3cd Ad Hoc meeting October 26, 2016

جامعة مؤتة العطاءات املركزية توريد وتركيب وتشغيل أجهزة شبكات/كلية الزراعة. Central Tenders Mu tah University

Supplemental Measurements of System Background Noise in 10GBASE-T Systems

TeamWork Kits Installation Guide

Backplane NRZ FEC Baseline Proposal

Transcription:

400GBASE-SR16 Cabling Paul Kolesar, CommScope Robert Lingle, OFS Alan Ugolini, USConec IEEE P802.3bs September 2014

Supporters John Abbott, Corning Gary Bernstein, Leviton Mabud Choudhury, CommScope Chris Cole, Finisar Mike Dudek, QLogic Mark Gustlin, Xilinx Jack Jewell, Ind./CommScope Jonathan King, Finisar Dave Lewis, JDSU Sharon Lutz, USConec Alan McCurdy, OFS Richard Mei, CommScope Rich Mellitz, Intel Andy Moorwood, Infinera John Petrilla, Avago Rick Pimpinella, Panduit Rick Rabinovich, Alcatel-Lucent Steve Swanson, Corning Paul Vanderlaan, Berk-Tek LLC George Zimmerman, CME/CommScope 2

Outline Cabling standardization update MDI lane assignment proposal Compatibility with structured cabling Rationale for choosing an MDI connector Proposed content for clause xx.m.n* * Using xx for 400GBASE-SR16 clause number 3

MPO-16 Standardization TIA TR-42 draft ANSI/TIA-604-18 First ballot completed in June 2014 Comments on second ballot to be resolved at TR-42.13 meeting in October 2014 Second ballot advanced to national level Defines 16-fiber (1-row) and 32-fiber (2-row) plugs with flat end-faces only, and adapter Keyed differently than MPO to prevent accidental mating attempts IEC 86B New project initiated at May 2014 meeting 32-fiber 2-row flat end-face plug, and adapter See backup slides for details Standard to become addition to IEC 61754 series KEY 4

Production Status and Performance Data for 16f and 32f MPO connectors To meet evolving application requirements, MT fiber count has grown from single row of 4, 8, or 12 fibers to versions with 2 to 6 rows of 12-fibers Development of 1x16 and 2x16 MTs are another progression of technology US Conec has 1x16 and 2x16 MT ferrule production tooling Parts have been molded for performance qualification Initial MM performance measurements are underway Telcordia GR-1435 testing is scheduled 5

Structured Cabling Standardization ANSI/TIA-568.3 Defines array cabling polarity methods and components for duplex and parallel links in structured cabling In second ballot for D revision (to become ANSI/TIA-568.3-D) Comments to be resolved at October TR-42 meeting Comments submitted to allow other than 12-wide array cabling 16-wide infrastructure would be standardized if accepted 6

MDI Lane Assignment Definition required to ensure interoperability Parallel optics introduce more degrees of freedom that must be constrained for interoperable connectivity Optimal lane assignment will be compatible with structured cabling and conventional optics The same array polarity in cabling systems should support all array applications without replacement of permanent link cabling while adhering to standard signal routing conventions 7

400GBASE-SR16 Proposal for Lane Assignments Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx 400G-SR16 optical lane assignments for MDI receptacle when viewed looking into the receptacle with keyway feature on top. Transmitters occupy the top row and receivers occupy the bottom row. This is essentially a 16-wide version of 100G-SR10 MDI but with transmitters on top for better heat dissipation and no unused positions. 8

How Array Polarity Works TIA-568 describes three methods: A, B, C. ISO & CENELEC one. All produce the same signal routing with different sets of components Key application examples: cabling TxTx TxTx RxRxRxRx For 1-row applications, methods deliver lateral signal transposition (Tx to Rx) Supports 40G/100G-SR4 cabling RxRxRxRxRxRxRxRxRxRx TxTx TxTxTx TxTxTx TxTx For 2-row applications, methods deliver lateral and row transposition (Tx to Rx) Supports 100G-SR10 These signal routing conventions support all standard parallel applications including INCITS T11 10GFC 1200-Mx-SN4P-I and HIPPI-6400 9

-SR16 Compatibility with Cabling Legacy 12-fiber cabling can support 400G-SR16 consuming three cable subunits using: fan-out modules -SR16 xcvr 32-f cord fan-out tri-furcated equipment cords -SR16 xcvr 32-3x12-f cord 3x 12-f cable 3x 12-f cable fan-out 32-f cord 32-3x12-f cord -SR16 xcvr -SR16 xcvr Future 16-fiber cabling can support 400G-SR16 consuming two cable subunits using: bi-furcated equipment cords, analogous to100g-sr10 -SR16 xcvr 32-2x16-f cord 2x 16-f cable 32-2x16-f cord -SR16 xcvr 89% fiber utilization 100% fiber utilization 10

Top row: position 1 Bottom row: position 13 Top row: position 12 Bottom row: position 24 Equipment Cords (Type-B) Position 12 Position 1 Position 12 Position 1 1. Today s standard for 2-row applications on 12-fiber cabling MPO-16 Top row: position 1 Bottom row: position 17 Top row: position 16 Bottom row: position 32 Position 12 Position 1 MPOs 2. Example -SR16 cord for 12-fiber cabling Top row: position 1 Bottom row: position 17 Top row: position 16 Bottom row: position 32 Position 16 Position 1 Position 16 Position 1 3. Analog of today s standard (1.) but for 16-fiber cabling All adhere to standard of delivering lateral and row signal transposition 11

Connectivity Method B Supporting Parallel Signals for 1-plug x 2-row Applications Proposed -SR16 MDI on modulo-16 cabling would follow this same construct. Transceiver Top Bot Row Row Rx Tx Rx Tx : : : : Rx Tx Rx Tx Top Row: Position 1 Bottom Row: Position 13 PULL Top Row: Position 12 Bottom Row: Position 24 PUSH PUSH PUSH Position 12 Position 1 Position 12 Position 1 Key-up to Key-up Mated Connections PULL PULL B B Position 1 PULL Position 12 Position 1 PULL Position 12 PUSH PUSH Type-B:2-1 Array Patch Cords Type-B:1-1 Array Cables Transceiver Top Bot Row Row Rx Tx Rx Tx : : : : Rx Tx Rx Tx Top Row: Position 1 Bottom Row: Position 13 PULL Top Row: Position 12 Bottom Row: Position 24 PUSH Position 12 PULL PUSH Position 1 Position 12 PULL PUSH Position 1 B B Position 1 PUSH PULL Position 12 Position 1 PUSH PULL Position 12 Key-up to Key-up Mated Connections Example Optical Path 12

Breakout = Likely Primary App for Gen 1 The proposed -SR16 MDI can also function as a high-density (4x) 100G-SR4 interface Increases switch radix at 100G Facilitates densely interconnected DC architectures at 100G Likely to be a primary volume application Switch -SR16 Xcvr 4x 100G-SR4 Switch -SR4 Xcvr Switch -SR4 Xcvr Switch -SR4 Xcvr Note: 4x100G-SR4 breakout can also exist between -SR16 transceivers via structured cabling, but not via AOCs Switch -SR4 Xcvr 13

16-fiber Cabling Applications Modulo-16 cabling is a superior match to parallel applications compared to modulo-12 cabling Simpler or fewer fan-out assemblies for 100% utilization 32-lane solutions, bi-furcated cords -SR16 xcvr 32-2x16-f cord 2x 16-f cable 32-2x16-f cord -SR16 xcvr 16-lane solutions, simple cords 16-lane xcvr 16-f cord 16-f cable 16-f cord 16-lane xcvr 8-lane solutions, bi-furcated cords -SR4 xcvr -SR4 xcvr 2x8-16-f cord 16-f cable 2x8-16-f cord -SR4 xcvr -SR4 xcvr 14

Why choose an array connector at the MDI? Precedent established in clauses 86 and 95 Per proposed clause xx.m.n (see later), behind the MDI may be a receptacled PMD pigtailed PMD Selecting MDI connector does not restrict pigtail attachment to PMD Open to innovation PMD PMD Undefined Choosing an MDI connector removes ambiguity Assists in defining signal locations Provides end-users with guidance for cabling installation patch cord selection MDI 15

Content for Baseline Draft The following 4 slides use clause 86 and 95 content as basis with modifications for 400GBASE-SR16 and MPO-16 16

Content for Clause xx.m.n (1 of 4) xx.m.n Medium Dependent Interface (MDI) The 400GBASE-SR16 PMD is coupled to the fiber optic cabling at the MDI. The MDI is the interface between the PMD and the fiber optic cabling (as shown in Figure xx-a). The 400GBASE-SR16 PMD is coupled to the fiber optic cabling through one connector plug into the MDI optical receptacle as shown in Figure xx-b. Example constructions of the MDI include the following: a) PMD with a connectorized fiber pigtail plugged into an adapter; b) PMD with receptacle. 17

Content for Clause xx.m.n (2 of 4) xx.m.n.1 Optical lane assignments The sixteen transmit and sixteen receive optical lanes of 400GBASE-SR16 shall occupy the positions depicted in Figure xx-b viewed looking into the MDI receptacle with the connector keyway feature on top. The interface contains 32 active lanes within 32 total positions. The transmit optical lanes occupy the top row. The receive optical lanes occupy the bottom row. See clause xx.m.n.2 for MDI optical connector requirements. Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Tx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Rx Figure xx-b -- 400GBASE-SR16 optical lane assignments viewed looking into the MDI receptacle with keyway feature on top. 18

Content for Clause xx.m.n (3 of 4) xx.m.n.2 Medium Dependent Interface (MDI) requirements The MDI adapter or receptacle shall meet the dimensional specifications of ANSI/TIA-604-18 adapter designation FOCIS 18A-k-0. The plug terminating the optical fiber cabling shall meet the dimensional specifications of ANSI/TIA-604-18 female plug connector flat interface designation FOCIS 18P-2x16-1-0-2-2. The MDI shall optically mate with the plug on the optical fiber cabling. Figure xx-c shows an MPO-16 female plug connector with flat interface, and an MDI. The MDI connection shall meet the interface performance specifications of IEC 61753-1 and IEC 61753-022-2. NOTE Transmitter compliance testing is performed at TP2 as defined in xx.k.j, not at the MDI. 19

Content for Clause xx.m.n (4 of 4) KEY MPO-16 female plug connector flat interface MDI Figure xx-c MPO-16 female plug connector flat interface and MDI 20

400GBASE-SR16 Conclusions Is extension of existing technology* low risk, easy spec creation Supports breakout to 4x 100G-SR4 broad market potential MPO-16 standardization and development Progressing at pace suitable for P802.3bs Proposed lane assignment Is directly compatible with emerging MPO-16 standard Can be supported on legacy structured cabling without violating signal routing conventions or replacing permanent link cabling Can be easily supported on modulo-16 cabling Will drive modulo-16 cabling development better solution * See king_3bs_01a_0514 21

Thank You. Questions? 22

Backup Slides 23

MPO-16 2-row Plug Position Numbering Convention OFFSET Cut-away isometric view of plug components 24

MPO-16 Plug Outer Housing Dimensions 7.7 mm 12.6 mm Outer dimensions are same as MPO 25

Guide Pin/Hole and Fiber Hole 1-row ferrule end-face 550µm guide pin/hole Conventional 250µm fiber pitch 26

Guide Pin/Hole and Fiber Hole 2-row ferrule end-face 5.3mm alignment pin/hole separation Conventional 500µm row pitch 27

Method Char. 1) Key orientations of array terminations Array Polarity Methods Distinguishing Characteristics Char. 2) Fiber order at array terminations Char. 3a) Array cable and cord Type(s) in parallel channels Char. 3b) 2-fiber cord Type(s) in multi-duplex channels Char. 4) Array adapter Type A up / down consecutive A + B A-to-A + A-to-B A Type-A cables and cords B up / up transposed B A-to-B B Type-B cables and cords C up / down pair-flipped Type-C cables and cords C + B A-to-B A See next slide Extensions to the methods must follow these characteristics, as departure from these characteristics defines a new method. Source: TR4211-2010-09-011a 28

Array Cable & Cord Types TIA 568 defines three types (A, B, C) for 1-row and 2-row apps cables and 1-row cords 2-row cords (for 2-row apps) Type-A Consecutive fiber order (key-up to key-down) Type-B Transposed fiber order (key-up to key-up) Type-C Pair-flipped fiber order (key-up to key-down) Adjacent pairs flipped Specific concatenations of these assemblies define the three methods for parallel applications 29