Honeywell. Manual DFRC. RF Remote Control Decorative Fire

Similar documents
GreenParking. Commissioning guide. GreenParking

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

EN Wireless programmable thermostat

Inserting the batteries. Basic settings of the remote control

Room thermostat Instructions for Use. For the user. Instructions for Use. geotherm

TDDFM14 OWNER S MANUAL

Programmable Room Thermostat With RF

Waterline Room Controller - Type WLCT3

2 Verify that the green light

Ducasa Digital Programmer

ST625TX Digital Room Thermostat

7 Day Digital Programmer

Radio Thermostat Clock

User Guide. Color Touchscreen Programmable Thermostat. ComfortSense Model: 13H /2017 Supersedes

LCD Thermometer / Clock S No. 1253

7 Day Digital Programmer 3 Channel Surface Mount

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

ST9100C User Guide. Features

Installation & Programming Manual. Please read before using this timer.

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

Electronic 7 User Operating Instructions

USER MANUAL Model: A5

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

Instructions Manual

Aspect 2 Circuit Digital Scene Control

USER & ENGINEER INSTRUCTION MANUAL

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Satellite Receiver. Chapter REMOTE CONTROL USING THE MENUS USING TEXT FIELDS. About Your Satellite Receiver. What you ll find in this chapter:


MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

Digital Timer. 1 About your Slimline Digital Timer. 2 Mechanism Dimensions. Cat No. D817SLIMDP Instruction Manual

COMFORT COMFORT CALL OWNER S MANUAL CALL SYSTEM P/N P BASE STATION & RF WIRELESS MODULE. Complete Control from TOTALINE

The Parts of The System

Automate Pulse Set-Up Instructions

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Comfort System T-32-P Universal Thermostat. Operation Manual

Atlas SCR. User Guide. Thyristor and Triac Analyser Model SCR100

Single Station Waterproof Timer

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

EXTERNAL. A digital version of this document is available to download and submit online at ADDRESS POST CODE

Master Time Clock MTC Users Manual

NT-9600 Wireless Barcode Scanner. Introduction

REMOTE DISPLAY WIRELESS DECODER MK II

1 Channel Multi-Purpose Programmer User Instructions

ServicePlus S17R Series 2 User Operating Instructions

Ambient Weather WS-01T-C Color Changing Wireless Temperature Night Light with Ambient Backlight (Console Only) User Manual

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

WS-6002U Atomic Clock. Instruction Manual

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

Ambient Weather WS-01T Color Changing Wireless Temperature Night Light with Ambient Backlight User Manual

DIGITAL SET TOP BOX STB 7017 INSTRUCTION MANUAL

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

Quick Setup 1 Unpack the projector

Operating instructions. Universal timer switch display

Please read this manual before using the C961 Display. Suzhou Bafang Electric Motor Science-Technology Co., LTD

Digi-Wave DLR-50. Digital Receiver. user guide MAN156D

Operating Manual for Clock / Auxiliary Displays for VHX systems

INSTRUCTION MANUAL DAFM2

Interactive HD-receiver

AE SERIES GPS MASTER CLOCK SYSTEMS

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

TU-8A. 8 Channel Digital Timer Unit. Programming Guide

BT Diverse Repeater. User Guide

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM441017D5601 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

GRANT RF CONTROL CENTER INSTALLATION INSTRUCTIONS Always disconnect battery while servicing or modifying the electrical system of the vehicle.

Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact us. This manual may contain technical or

Simon XT/XTi/XTi-5 LTE Module INSTALLATION GUIDE

Standard Digital Terminal High-Definition Digital Terminal. User Guide

User interface. Abbreviations / Meanings

IoT Toolbox Mobile Application User Manual

Getting started with

Night Hawk Firing System User s Manual

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT

ComfortChoice Touch Thermostat. Designed for ZigBee R Wireless Technology USER GUIDE

FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL

HD/SD-SDI TO VGA CONVERTER. DAC-60 Quick Start Guide.

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Slimline Digital Electric Radiator. Step by Step Programming Guide

MYE TV Audio Grabber

Extender w/ RS-232 and 2-way IR

User Manual. Tensioned Screens. Website: Tel:

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Converts any TV to Digital. MFR-300 User Guide

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT. MATERIAL: White 16lb (60g/m sq), uncoated, prefer recycled stock Ink: Black

DICKSON ES120/ES120A DICKSON. Electronic Signal Data Logger. Specifications. Applications, Features, & Getting Started. Instructions / Operating

Standard Definition Digital Set Top Box

SIM 5 series Lamp Kit

IMPORTANT SAFETY INSTRUCTIONS

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

GDB9 INSTRUCTION MANUAL DIGITAL TERRESTRIAL RECEIVER

Product Identification

Operating Instructions. Room temperature controller with clock

Transcription:

Honeywell Manual DFRC RF Remote Control Decorative Fire

DISPLAY AND KEYS Display Key Up Key Down Key Stop/Stand-by Key Menu

Display Manual operation. Time schedule active. Active time period. Closed (left) or open fire place type (right). Decorative fire is on. Decorative fire can be ignited. Fault of decorative fire can be reset. Burner off/setting down (left), burner on/setting up (right). Busy (for instance while decorative fire is been ignited). Fault. Main plug of the decorative fire is plugged in the other way round. RF-communication. Batteries are almost empty (symbol flashes). Time representation (24-hours or 12-hours). Days of the week. Square indicates actual day. Temperature representation. Temperature sensor(s) are defect. Keys Enhance setting or change selection. Lower setting or change selection. Choose menu and menu selection. Stop setting menu or go to stand-by.

SET UP FOR OPERATION The RF remote control makes it possible to operate your decorative fire both manual as by means of a time schedule.* The temperature and the flame height can be manually controlled. The time schedule only controls the temperature. The possible time schedules are*: A time schedule with the same settings for each day. A time schedule with separate settings for the week days (monday to friday) and the weekend. A time schedule with separate settings for each day. For each day, two, four or six different time periods can be set.* The time schedule can easily be set by setting the begin time and the temperature set point of each period. Flame Symbol A flame symbol indicates that the burner of your decorative fire has been switched on. Batteries Before you can take the RF remote control in operation, the two supplied batteries (type AA) have to be placed. After the batteries have been placed, the RF remote control is ready for manual operation with flame height control. To save batterie life, some time after the last key pressure, the display goes blanc*, unless the decorative fire is switched on. * The availability of the option depends on the factory setting of the decorative fire. 4

RF Communication The RF remote control can only communicate with a decorative fire after the RF remote control has been bound with that decorative fire. If the power of these both devices is switched on within 5 minutes after each other, the binding goes automatically. This display is shown if the RF remote control has not been bound. The symbol flashes. Make sure the mains of the decorative fire has not been switched on for more than 5 minutes and start the binding as follows: Press keys and simultaneously. The display below is shown. This display is shown during binding. The symbol flashes. When the binding is finished, the default display is shown. Note: In case of replacement of the decorative fire or the RF remote control, the binding has to be initiated manual, see RF REMOTE CONTROL BINDING, on page17. Time and Day The time schedule of the RF remote control can only be used if the time has been set. The time and day can be set in the User Menu, see Setting Time and Day on page 13. The time representation, 12-hours or 24-hours, can be set in the Installation Menu, see Choice 12- or 24- Hours Representation on page 15.

OPERATION The RF remote control is equipped with a display and four keys. Because of this the decorative fire can be easily operated and settings easily be adjusted. There are two setting menus available: User menu Installation menu Press key once* to select the User menu, or keep key pressed for ten seconds to select the Installation menu. Manual Operation Dependent on the choice made in the User menu, the temperature or the flame height can be controlled manual. Flame height control The decorative fire must be manually switched on and off. Igniting decorative fire Press keys and simultaneously if the adjacent display is shown. * In some cases, dependent on the factory settings, key has to be pressed for 2 seconds instead of pressed once.

This display is shown. The symbols and are flashing to indicate the decorative fire is being ignited. After the decorative fire has been ignited, the display below is shown. The flame height can now be manually controlled. Setting flame height Press key or once. The display below is shown. The value of the current flame height flashes. Set the required flame height by pressing key or. Dependent on the key pressed, the symbol or is shortly visible on the display. The flame height can be set between1 and 15. Wait a few seconds or press key to leave the menu. Note: The flame height can only be controlled if the decorative fire has been switched on.

Switching off the decorative fire Press key once to switch off the decorative fire. This display is shown. The symbol flashes to indicate the decorative fire is being switched off. After the decorative fire has been switched off, the default display is shown again. Temperature control The decorative fire is automatically switched on and off according to the heat demand. Press key or once to adjust the required temperature. The display below is shown. The current temperature set point flashes. Set the required set point by pressing key or. Dependent on the key pressed, the symbol or is shortly shown on the display. The temperature can be set between 5,0 and 35,0 C. Wait a few seconds or press key to leave the menu.

Temporarily interrupting temperature control When temperature control is used, the decorative fire can temporarily be switched off. Press key once to switch off the decorative fire. This diplay is shown. The symbol flashes to indicate the decorative fire is being switched off. After the decorative fire has been switched off, the display below is shown. The symbol flashes to indicate the decorative fire has to be ignited manually by pressing the keys and simultaneously. When the decorative fire is ignited again, the temperature control becomes active. Note: The temperature set point can not be changed during the temporarily temperature control interruption.

Time Schedule The temperature is controlled according to the time schedule, see Setting Time Schedule on page 14. The decorative fire is fully automatically ignited and switched off. Temporarily changing the temperature set point The temperature set point of a time schedule period can temporarily be enhanced or lowered. Press key or once to set the temporarily set point. The display below is shown. The current temperature set point flashes. Set the temporarily required temperature set point by pressing key or. Dependent on the key pressed, the symbol or is shortly shown on the display. Wait a few seconds or press key to leave the menu. This display (example) is shown. The symbol indicates that the temperature set point has been adjusted manually. The temporarily adjustment can be undone by setting the manually adjusted set point back to the set point of the current time period. In case of a transition to a new time period, the temporarily adjustment is cancelled automatically. 10

Temporarily interrupting time schedule In case of the use of a clock programme, the decorative fire can also be switched off temporarily. Press key once if the decorative fire has been ignited. This display (example) is shown. The symbol flashes to indicate the decorative fire is being switched off. After the decorative fire has been switched off, the display below is shown. This display (example) is shown. Symbol flashes to indicate the decorative fire has to be ignited manually by pressing keys and simultaneously. When the decorative fire is ignited, the time schedule becomes active again. Note: The temperature set point can not be changed when the time schedule is temporarily interrupted. 11

USER MENU In the User Menu the following choices* can be made: Manually with flame height control Manually with temperature control Time schedule (temperature control) In the User Menu the following settings* are available: Time Day of the week Time schedule Note: The User Menu is left by pressing key last key press. or five seconds after the Manually or Time Schedule Press key once. The display below is shown. A combination of two symbols flashes. There are three possilbe combinations: + : manually with flame height control + : manually with temperature control + : time schedule (temperature control) Select the required combination by pressing key or. Wait a few seconds or press key to leave the menu. * The availability of choices and settings depends on the factory setting of the decorative fire. 12

Setting Time and Day Press key a few times until the display below is shown. The current set time flashes. Set the actual time by pressing keys and. Press key. The days of the week are flashing. Select the actual day of the week by pressing keys and. The open square indicates the day selected. Wait a few seconds or press key to leave the menu. Note: The days of the week are not shown in case a 1 day time schedule has been chosen. 13

Setting Time Schedule Dependent on the choices made in the Installation Menu, 1, 2 or 7 time schedules and II, IV or VI time periods per day can be set. The setting of the clock programmes is the same for all choices. Setting a clock programme is as follows: Press key a few times until the diplay below is shown. The begin time of time period I flashes. Set the required begin time by pressing keys and. Press key. The current temperature set point of time period I flashes. Set the required temperature set point for time period I by pressing keys and. Press key and repeat the steps above to set the required begin time and temperature set point for all periods and days. It is also possible to switch off the decorative fire during a set period of time. To do so, select --,- during the setting of the required temperature (see the example opposite). Wait a few seconds or press key to leave the menu. 14

INSTALLATION MENU Select the Installation menu as follows: If selected, leave the User menu. Then keep key pressed for ten seconds. In the Installation Menu the following choices* can be made: 12- or 24-hours time representation Time schedule (1, 5/2, 7days or ) Number of time periods per day (II, IV or VI) Note: The Installation Menu can be closed by pressing key automatically five seconds after the last key press. or 12- or 24-Hours Representation Press key a few times until one of the displays below is shown. The current set time representation flashes. Select the required time representation by pressing key or. Wait a few seconds or press key to leave the menu. * The availibility of the choices depends on the factory setting of the decorative fire. 15

Time Schedule (1, 5/2, 7 days or ) Press key a few times until one of the displays below is shown. Select the required time schedule (1, 5/2, 7 or ) by pressing key or. Time schedule 5/2 is represented by the display showing 1..6. Wait a few seconds or press key to leave the menu. Note: Choice means no time schedule is used. Only manually operation with flame height control is now possible. Day Time Periods (II, IV or VI) Press key a few times until one of the displays below is shown. The current choice (digits) flashes. Select the required day time periods (II, IV of VI) by pressing key or. Wait a few seconds or press key to leave the menu. 16

RF REMOTE CONTROL BINDING In case of replacement of either the decorative fire or the RF remote control, the binding must be started manually. Act as follows: Press key a few times until the display below is shown. Make sure the mains of the decorative fire has not been switched on for more than 5 minutes. Press keys and simultaneously. The binding is started and the display below is shown. This display is shown during the binding. The symbol flashes. When the binding succeeds, the default display is shown. RF RECEIVING SENSITIVITY Press keys and simultaneously. The display below is shown. The RSSI (Receiver Signal Strength Indicator) values are shown. At the top left the RSSI of the remote control and at the bottom right the RSSI of the DFGT. RSSI: from -20 to -70 is good from -80 to -100 is poor If needed, hold the remote control closer to the decorative fire in order to improve the reception. 17

REPLACING BATTERIES Your RF remote control operates with two alkaline batteries (type AA). If the symbol is shown flashing on the display, the batteries have to be replaced. If the batteries are completely empty, the display will go blanc. Therefore, replace the batteries of the RF remote control in time. Replace the batteries as follows: 1... 4.. Remove the back cover of the RF remote control by moving the back cover down a few millimeters (see figure 1) and then lift up the back cover. Remove the old batteries from its holder. Place a new set of batteries in the holder as shown in figure 2. Replace the back cover of the RF remote control by placing the tabs A and B of the back cover (figure 3) in the according notches of the housing (figure 2). Push the back cover up to secure it. The current time and day of the week must be set again after replacement of the batteries. However, this is only necessary in case a clock programme is used. Note: Don t throw empty batteries away but dispose of them as chemical waste. 18

figure 1 figure 2 A + B A + B figure 3 A B A B 19

FAULT INDICATION The displays below indicate possible fault situations. Communication failure between RF remote control and decorative fire. The symbol flashes. The distance between the decorative fire and the RF remote control is probably too large. Hold the RF remote control nearer to the decorative fire. Fault of the decorative fire. The display shows an F, followed by a 2-digit fault code. The symbol flashes. A so called lock-out fault of the decorative fire. On the display an F, followed by a 2-digit fault code, is shown. The text reset indicates that the decorative fire can be reset. The symbol flashes. See also Terminate Lock-Out Failure. 20

Failure of the temperature sensor of the decorative fire. The temperature sensor in the RF remote control operates as normal. The text and the measured temperature are shown alternating. The display shows this situation in case a time schedule has been choosen. Failure of the temperature sensors of both the RF remote control and the decorative fire (or the latter not present). There is an automatic switchover to manual operation with flame height control. Terminating a Lock-Out Failure A lock-out failure (the text reset is shown) of the decorative fire could possibly be terminated. Press keys and simultaneously. The display below is shown. The symbol indicates that it is possible to reset the decorative fire. After the decorative fire has been reset, the default display is shown. The decorative fire can be reset 5-times per day at the most. Note: Consult also the manual of your decorative fire or consult your installer. 21

WARRANTY This Honeywell product was produced with the most care and highest quality demands. Honeywell warrants this product, excluding batteries, for a period of 24 months from the date of purchase. This date must be included on a valid proof of purchase. This warranty covers manufactoring faults with respect to material, components or finishing. Defects or malfunctions caused by wrong application or treatment of this product are excluded from this warranty. Claims to this warranty must always be made at the retailer of this product. 22

Inhoudsopgave DISPLAY AND KEYS 2 SET UP FOR OPERATION 4 Flame Symbol 4 Batteries 4 RF Communication 5 Time and Day 5 OPERATION 6 Manual Operation 6 Time Schedule 10 USER MENU 12 Manually or Time Schedule 12 Setting Time and Day 13 Setting Time Schedule 14 INSTALLATION MENU 15 12- or 24-Hours Representation 15 Time Schedule (1, 5/2, 7 days or ) 16 Day Time Periods (II, IV or VI) 16 RF REMOTE CONTROL BINDING 17 RF RECEIVING SENSITIVITY 17 REPLACING BATTERIES 18 FAULT INDICATION 0 Terminating a Lock-Out Failure 1 WARRANTY 2 23

EN2H-0035NL15 R0307 Honeywell