Service. Nu Instruments Service & Upgrades. ICP-MS, GD-MS, IRMS, Noble Gas.

Similar documents
How Quadrupole Size Affects Research

GCxGC Comprehensive Two-Dimensional Gas Chromatography

Agilent High Capacity RV Pumps & Roots Pumping Systems

AIM INTRODUCTION SIMPLIFIED WORKFLOW

GCxGC Comprehensive Two-Dimensional Gas Chromatography

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Practicality and Performance

Quadrupoles have become the most widely used

Nova NanoSEM Superior Imaging and Analytical Performance

ih Series Drypumps (505) idealvac.com idealvac.com

1.2 Universiti Teknologi Brunei (UTB) reserves the right to award the tender in part or in full.

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

HyPrecision Waterjet. Optimizing waterjet performance

Mechanical aspects, FEA validation and geometry optimization

Top reasons to switch to Sony s professional LCD LUMA TM monitors

HyPrecision Waterjet. Optimizing waterjet performance

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

Results of the June 2000 NICMOS+NCS EMI Test

ABB MEASUREMENT & ANALYTICS. MB3000 The most reliable FT-IR laboratory analyzer

Universal High Current Implanter for Surface Modifications with ion beams Extensive range of ion species, including refractory metals Magnetic mass

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

EPJ Web of Conferences 95,

Customer Responsibilities. Important Customer Information Infinity LC/1260 Infinity LC Site Preparation Checklist

TIME RESOLVED XAS DATA COLLECTION WITH AN XIA DXP-4T SPECTROMETER

Ecoline S series. Precision solutions for quality production. Innovations for a better world.

Compact and powerful. The small chamber machines by MULTIVAC.

Ultimate quality control. No compromise. PROCESS / QUALITY CONTROL

PRACTICAL DESIGN TECHNIQUES FOR SENSOR SIGNAL CONDITIONING

Detailed Design Report

CITOCUT Plasma inverter cutting range

Highly Accelerated Stress Screening of the Atlas Liquid Argon Calorimeter Front End Boards

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Achieving More Efficient Data Review with OpenLAB CDS

Hitachi Kokusai Electric Comark LLC

HIGH VACUUM PUMPS. Hybrid Turbomolecular Pumps. ATH series. Adixen by Alcatel Vacuum Technology

DirectView Elite CR System. Improve workflow, productivity, and patient throughput.

SLS RF operation report 2003

Cyclotron Institute upgrade project. H. L. Clark, F. Abegglen, G. Chubarian, G. Derrig, G. Kim, D. May, B. Roeder and G. Tabacaru

Customer Responsibilities. Important Customer Information. Agilent InfinityLab LC Series Site Preparation Checklist

ABB MEASUREMENT & ANALYTICS. MB3600 The most reliable FT-NIR laboratory analyzer designed for QA/QC

Optical Cryostat - Omniplex TM

Series 3000 Dual Cast Transmitter

ROHDE GAS AND RAKU A BURNING PASSION FOR THE BEST POSSIBLE RESULTS. Photo Patricia Schichl

If you have questions or problems in providing anything described as Customer

World s smallest 5MP stand-alone vision system. Powerful Cognex vision tool library including new PatMax RedLine and JavaScript support

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

Agilent 7000 Series Triple Quadrupole GC/MS System

R&S FSW-K54 EMI Measurement Application Detecting and eliminating electromagnetic

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

GC/LC-MS: data acquisition rate and peak reconstruction

CARESTREAM DIRECTVIEW Elite CR System

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

HICUBE. The modular pumping stations for all applications in high and ultra-high vacuum

CARESTREAM DIRECTVIEW Elite CR System

Product Brochure Version R&S RSC Step Attenuator Where precise signal levels count

SPEAR 3: Operations Update and Impact of Top-Off Injection

RGA13, 12/10/17 Ultra High Resolution 20mm Quadrupole with Dual Zone operation

Challenges in the design of a RGB LED display for indoor applications

PRESTOJET Plasma inverter cutting range

Sample Analysis Design. Element2 - Basic Software Concepts (cont d)

R&S ZN-Z32/-Z33 Automatic In-line Calibration Modules Ensuring high accuracy with thermal vacuum testing and multiport measurements

DDF-SE. Application example. Feed-through Stationary Rotary Feed-through. Max. speed 500 revs/ min. Air feed-through Up to 6x

Silicon PhotoMultiplier Kits

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

Critical Benefits of Cooled DFB Lasers for RF over Fiber Optics Transmission Provided by OPTICAL ZONU CORPORATION

HD/SD- SDI to VGA Converter DAC-60 Quick Start Guide

Agilent 87075C Multiport Test Set Product Overview

Datasheet. High-Performance airmax Bridge. Models: NBE M5-19, NBE-M5-16. Uniform Beamwidth Maximizes Noise Immunity. Innovative Mechanical Design

Stark Spectroscopy Deanna s Experimental Procedure NWU Hupp Lab Fall 2003

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Troubleshooting EMI in Embedded Designs White Paper

Thermocouple and RTD Modules for Compact FieldPoint

Etching Part 2. Saroj Kumar Patra. TFE4180 Semiconductor Manufacturing Technology. Norwegian University of Science and Technology ( NTNU )

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

TEXAS A&M AGRILIFE RESEARCH

Review of Diamond SR RF Operation and Upgrades

SHARP Plasma inverter cutting range

ABRS Series. Air-Bearing Rotary Stage. Direct-drive, slotless brushless servomotor. Zero cogging motor for outstanding velocity stability

Applied Materials. 200mm Tools & Process Capabilities For Next Generation MEMS. Dr Michel (Mike) Rosa

Effects of the cryogenics operational conditions on the mechanical stability of the FLASH linac modules

Linac 4 Instrumentation K.Hanke CERN

Vivat Prodigy? Juraj Bella. Core capability for Chemistry Research EPSRC & The University of Edinburgh

HD Review March 30, 2011 Franz Klein

Welcome and FRIB Project Status. FRIB Highlights and Plan Ahead

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

SLAC R&D Program for a Polarized RF Gun

Most advanced, portable, high-power 532nm Diode-Pumped Solid-State Photocoagulator

Technical Procedure for Scanning Electron Microscope/ Energy Dispersive X-Ray System (SEM/EDX) for non-gsr Casework

!"!3

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

Introduction of Medium Current Ion Implanter EXCEED3000AH-8C -New 200mm Tool-

HIGH CURRENT IMPLANTER 200KeV - SERIES 1090 TECHNICAL DESCRIPTION

Philips CoralCare FAQ

Simple all-in-one design style with front stereo speakers and natural ventilation system

Thermo Scientific Polar Series Cooling/Heating Recirculating Chillers

About... D 3 Technology TM.

Transcription:

Service Nu Instruments Service & Upgrades ICP-MS, GD-MS, IRMS, Noble Gas www.nu-ins.com

Nu Instruments Maintenance Contract Options Nu Instruments provides a range of post-warranty service solutions to suit various customer requirements. Several annual maintenance service contracts are available as well as attractive on-demand solutions. These services allow our customers to focus on their core activity and leave their maintenance needs and worries to us. Annual preventative maintenance visit Essential Expanded Expanded Comprehensive Comprehensive+ for Academia Basic consumables for PM visit Prioritised access to technical support On-site support Not included (discounted rate available) For single reported breakdown Spare parts requirements (Discounted rate available) For single reported breakdown For single reported breakdown 1st priority for on-site support Prioritised ahead of noncontract customers Prioritised ahead of noncontract customers 1st priority for technical support Prioritised ahead of noncontract customers Prioritised ahead of noncontract customers Annual consumables kit Dedicated response times 3rd party OEM items Application training credits Further discounts on consumables Preferential pricing on performance enhancing upgrades Different levels of benefits included in Nu Instruments Maintenance Service Solutions: Pre-planned, budgeted service expenditures Full service coverage solutions include an unlimited number of unscheduled visits to handle unexpected breakdown events Optimised instrument performance and maximized operational time Discounted pricing on Nu Instruments stand-alone aftermarket services p2

MC-ICP-MS Nu Plasma II Enhanced Sensitivity Interface Maximized intermediate vacuum Enhanced transfer optics Minimal effect on oxide levels Significantly improved sensitivity Uncompromised analytical performance Software Switchable Pre-amplifiers Selected preamplifiers each can be fitted with two resistors of various sizes (10 10 Ω, 10 11 Ω, 10 12 Ω), in order to enlarge the dynamic range of the chosen Faraday detectors. The 10 12 Ω resistor is suitable for detecting smaller beams with a higher signal to noise ratio. The 10 10 Ω resistor is suitable for larger beams. Fast switching between different resistor values using the software without breaking the pre-amplifier housing vacuum Daly Upgrade Larger dynamic range Better gain stability Larger linear range Wider peak flat Longer life time p3

Low Sulphur Upgrade Low sulphur gas panel and tubings are offered to significantly reduce the instrument sulphur background making it more suitable for low-level sulphur analysis Uncompromised analytical performance without any side effect on other isotope systems Dry Pump Upgrade The compact 110 m 3 /h air-cooled Edwards nxli110 dry pump improves pumping efficiency and generates ca. 10% sensitivity enhancement without elevating the oxide formation or inducing any non-linear mass bias behaviour. Reduces the frequency of preventative maintenance. Eliminates the formation of hydrocarbon molecules and therefore the background counts for actinides. High Mass IC Upgrade Ideal for U-Pb geochronology, low level B and Li isotope measurements P3 Source Upgrade Enhanced Sensitivity Interface. All new innovative torch box design allowing easy connection of a wide range of sample introduction devices. Robust water-cooled 3rd generation RF Generator with frequency tuning, delivers rapid response to changing matrix conditions Improved RF shielding Easy access to expansion chamber front plate for exchanging of cones Maximum stability and reliability p4

IRMS PERSPECTIVE Water trap cold finger upgrade Replaces existing Nu Carb chiller and water trap with a low volume fully temperature controlled cold finger and high purity valve. Removes water from sample CO 2 cryogenically as before using liquid nitrogen as a coolant. For clumped isotopes there is an increase in sample throughput as pressure of CO 2 is higher during transfer through the Adsorption trap. Reduction in laboratory noise as the water trap chiller is removed. Reduction in electricity consumption of the instrument. IRMS HORIZON Horizon HD filter upgrade Improves precision and sensitivity in measurement of deuterium content in hydrogen (δ2h). Reduces sample size requirement. Incorporates a mini-esa filter in front of the HD Faraday cup. Prevents low energy He+ from entering HD Faraday cup (all continuous flow applications). p5

GD-MS astrum Atmospheric Liquid Nitrogen Dewar The atmospheric liquid nitrogen system offers a lower consumption of liquid nitrogen (1.5 lph vs. >3 lph for a pressurized vessel) and reduced cost of ownership as regular safety inspections as not required as with a pressurized vessel. Fixed Source Slit Upgrade The fixed source slit upgrade provides multiple slits of the same size which can be selected independently as each is eroded by the ion beam. This extends the service time between replacements and therefore improves the operational uptime available for the Astrum. Noble Gas Noblesse High Resolution Enhancement Upgrade The high resolution upgrade fits our new ion source to provide greatly improved resolving power (MRP, defined by m/dm, where dm corresponds to 5 to 95% on the side of the peak). The original Noblesse offered MRP>1500, but our new source achieves MRP>5000 in the axial detector. This unique source can be adjusted continuously for higher sensitivity or higher resolving power, without using an adjustable slit. MRP=5000 provides easy resolution of all carbon based interferences at Ar, potentially leading to more accurate results, especially for young or small samples. 40 Ar ++ can also be resolved from 20 Ne +, which makes Ne analyses simpler, removing the need for 40 Ar ++ correction. p6

HR-ICP-MS attom Fixed Slits Upgrade The fixed slit upgrade allows Attom to be used for multiple resolution methods in an automated batch with reproducible changes in resolution. The use of multiple slits of the same size extends the service intervals for source slit replacement as alternate slits can be selected as others wear through from the intense ion beam. The independent operation of both the source and collector slits means that different resolutions can be selected by matching each source slit size with different collector slits. Fast Magnet Electronics The fast magnet upgrade for Attom significantly improves the speed of analysis for all methods that require magnet field changes. For Hall probe controlled magnet jumping, jump times are now 1-2 ms/amu and hysteresis loops are 0.6-0.8 seconds (compared to the previous 15ms/amu and 6-8 seconds hysteresis loop). This means that a typical method cycle of 10 isotopes across the full mass range with 1 second of data acquisition at each mass would take 11.1 seconds compared to over 20 seconds previously. Similarly, for LinkScan analysis, the fast magnet controller has a new 200V LinkScan option which allows the collection of full mass spectra in both the up and down scan in 103ms compared to the previous 220ms. Extra Sensitivity Interface The ES interface is designed to enhance the dry aerosol sensitivity of the Attom for laser ablation and desolvator applications. Improvements up to a factor of 3 have been reported (a) with no impact on the normal wet aerosol sample introduction performance. The interface also includes a screw-in locking ring mount for the sample cone which is more robust and easier to handle than the previous generation sample cone mount system. (a) Pietruska and Neymark, J. Anal. At. Spectrom., 2017, 32, 1135-1154 p7

Innovators in Mass Spectrometry Geochemistry Planetary Science Environmental Science Life Science Material Science Metals & Alloys Nuclear Science Nanotechnology Semiconductor Nu Instruments Limited Corporate Headquarters Unit 74, Clywedog Road South, Wrexham Industrial Estate, Wrexham, LL13 9XS - UK. Tel: +44 (0)1978 661304 nu.info@ametek.com Innovators in Mass Spectrometry. We deliver cutting-edge science and technology solutions, and offer our customers unparalleled support and maintenance service through the comprehensive Corporate Headquarters Nu Instruments UK Regional Contacts Nu Instruments Europe Nu Instruments Americas Nu Instruments Asia program. nu.sales@ametek.com europe-sales.nu@ametek.com americas-sales.nu@ametek.com asia-sales.nu@ametek.com visit us online: www.nu-ins.com Service version BRO21.3 All mentioned trademarks are registered by their respective owners.