Operating Procedures for RECO1 & RECO2

Similar documents
Chapter 17: Online Scanning

Import and quantification of a micro titer plate image

E X P E R I M E N T 1

Printing From Applications: QuarkXPress 8

PHI 5000 VersaProbe TM Operator s Guide

Operating Instructions for Scanmark insight 4ES Scanner with QuickScore

SEM- EDS Instruction Manual

Board Production In CircuitPro

Sheffield Softworks. Copyright 2015 Sheffield Softworks

Scanning Electron Microscopy (FEI Versa 3D Dual Beam)

KRAMER ELECTRONICS LTD. USER MANUAL

Torsional vibration analysis in ArtemiS SUITE 1

for the Epson Stylus Pro 4000 User s Guide

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

Forensic Video Analysis Technical Procedure Manual Page 1

SIDRA INTERSECTION 8.0 UPDATE HISTORY

Neat Video noise reduction plug-in for Premiere (Win)

Florida State University Thayumanasamy Somasundaram

Netflix on the IMC IMC and up. User guide for viewing Netflix Content

Quick Start Bruker Dimension Icon AFM

The DataView PowerPad III Control Panel

ACUSCREEN NDT Joaquín González -

TABLE OF CONTENTS. 2 SGM Light Technology 23/08/1999 Ver. 2.00

ECT 224: Digital Computer Fundamentals Digital Circuit Simulation & Timing Analysis

Amplification Setup Methods for the Maxprep TM Liquid Handler Technical Manual

Test Records. Scanning Test Records. This document provides a step-by-step tutorial on how to scan Test Records and verify the imported information.

User Guide for Customers Register & Reserve Colours

CLA MixHub. User Guide

Neat Video noise reduction plug-in for After Effects (Mac)

Neat Video noise reduction plug-in for Pinnacle Studio

SR-D8-M, SR-D8-S. (Ver ) SOFTWARE INSTRUCTIONS

Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04

University of Liverpool Library. Introduction to Journal Bibliometrics and Research Impact. Contents

Neat Video noise reduction plug-in for Premiere (Mac)

HCImage Live Getting Started Guide

invr User s Guide Rev 1.4 (Aug. 2004)

Update Records. Scanning Update Records

Source/Receiver (SR) Setup

Pre-processing of revolution speed data in ArtemiS SUITE 1

Printing From Applications: Adobe InDesign CS3, CS4, and CS5

Automate Pulse Set-Up Instructions

HV/PHA Adjustment (PB) Part

Preparing for remote data collection at NE-CAT

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

Characterization and improvement of unpatterned wafer defect review on SEMs

Quick reference guide

Zombie Makeup Artist plugin Control layout

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

The. finale. Projects. The New Approach to Learning. finale. Tom Carruth

Post Build Reports in PowerScheduler

DS-575W User's Guide

Instructions for DataMark PDF Temperature Logger

Statement SmartLCT User s Manual Welcome to use the product from Xi an NovaStar Tech Co., Ltd. (hereinafter referred to as NovaStar ). It is our great

Standard Operating Procedure of nanoir2-s

Manual for TV software. TT-Viewer version Figure: TT-budget S2-3200

Why Does it Have to Be So Hard?

Footnotes and Endnotes

The ADAPTS function has been enhanced to support the new scan table mode as well as supporting the existing super stimulus mode.

FOR WWW TEACUPSOFTWARE COM User Guide

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

Setup Guide. SpectraCal ColorBox. (also eecolor) Image Calibration Processor. Rev. 1.1

Calibrating the timecode signal input

MTL Software. Overview

Confocal Application Notes Vol. 2 May 2004

PulseCounter Neutron & Gamma Spectrometry Software Manual

ViewCommander- NVR Version 3. User s Guide

XNET-NVR User s Guide

Scan Converter Installation Guide

How-to Setup Motion Detection on a Dahua DVR/NVR

Scanning Entry Records Entry Records 1) Tools Menu Scanning Wizard 2) Using Scanner Hardware Contro 3) Entry Front Side 1

9.5 Add or Remove Samples in Single Access Mode

Specific Example: Final Design as DWG, Original Contours as DWF file

Neat Video noise reduction plug-in for Final Cut (Mac)

Setting up a RTK Survey Using Trimble Access

Table of content. Table of content Introduction Concepts Hardware setup...4

Symphony Workflows. Barcoding and Maintaining Your Library s Collection

Case study: how to create a 3D potential scan Nyquist plot?

Neat Video noise reduction plug-in for AVX hosts (Win)

The BAT WAVE ANALYZER project

Synergy SIS Attendance Administrator Guide

Digital Video User s Guide. the Future. now showing

Setup Guide. Teradek COLR. Rev. 1.1

Neat Video noise reduction plug-in for Vegas

Welcome to the U-verse App

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

using the Scott A Speakman, Ph.D Center for Materials Science and Engineering at MIT

Q Light Controller+ Positions and EFX explained

Setup Guide. Blackmagic Design HDLink Pro. Rev. 1.1

Linkage 3.6. User s Guide

ecast for IOS Revision 1.3

GS122-2L. About the speakers:

WJ-HD616K/716K Quick Reference Guide

OPERATING GUIDE. M-Vision Cine 3D series. High Brightness Digital Video Projector 16:9 widescreen display. Rev A August A

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Nattress Standards Conversion V2.5 Instructions

Amcom Software RECEIVING AT ITEM LEVEL W/POCKET PC SCANNER DAILY PROCESS

Panaray MSA12X. Modular Steerable Array Loudspeaker. Design Guide

Ford AMS Test Bench Operating Instructions

dbtechnologies QUICK REFERENCE

Using Extra Loudspeakers and Sound Reinforcement

Transcription:

Operating Procedures for RECO1 & RECO2 Reconstruction of Data 1) Open CT Pro 3D a. Remember, when the computer you are working on is receiving files from the scanner, it cannot reconstruct data b. You will need to use the other RECO computer to reconstruct during scans 2) File -> Open -> navigate to your scan s.xtekct file (usually on D drive or possibly on the Teilhard server) 3) Image Tab -> Comparison of sequential images -> check +/-1, set speed to fastest, keep At sequence end, reverse direction checked and click Start

4) Watch image on right, if sample changes place significantly it may need to be rescanned or be the cause of artifacts discovered later on in procedure. Take note, but proceed either way. 5) Centre of rotation Tab -> Centre of Rotation -> Slice selection -> select Dual 6) Move red lines in top left image to intersect sample at two different, semidistant points a. Make sure these cross sections contain a decent amount of contrast in the image otherwise the center of rotation calculation may fail. 7) Click Start 8) Within 1-2 minutes Found should appear next to Upper and Lower

9) Check Image at right, if it s in focus proceed onto next step, if it s out of focus consult a SMIF staff member for using the Manual option under Center of rotation 10) Setup Tab and position red line to create a cross section of your sample 11) Under Radius of reconstruction, change mask radius percentage to 75% 12) Under Reconstruct slice at bottom of panel, change Quality to 25% 13) Under Beam hardening menu check Reconstruct all presets and click Start at bottom of left panel

14) Cycle through the presets leaving selected the one that results in the best quality image on the right 15) Under Noise reduction menu check Reconstruct all presets and click Start at bottom of screen (same process as steps 13 and 14) 16) Cycle through the presets leaving selected the one that results in the best quality image on the right 17) When satisfied with reconstruction image quality at right, change Mask radius percentage back to 100% and Quality back to 25% 18) Go to Volume Tab 19) Crop image on right in both views by selecting the appropriate view from the top left of the screen by dragging the sides of the red box a. Make sure that you leave a good amount of space on either edge as you could be cropping your sample on other not currently viewable angles 20) Double check to make sure box does not clip out any part of your region of interest

21) Under Output Format select 16bit under TIFF image stack and change Maximum: values above this are clipped to 65535 under Specified scaling 22) Reconstruct volume -> Name should be in form to that in below image 23) Click Start (ONCE!) and message should appear next to button stating CT agent accepted file (YourFileName.xtekct) 24) Right-Click, select Restore and CT Agent window should appear to indicate reconstruction time 25) Note time and status of CT Agent before trying to reconstruct additional scans on computer or loading current scan into Volume Graphics a. Multiple reconstructions can be set up to run one after the other by repeating this procedure and selecting the Pause button in CT Agent b. When ready, the press the Play button and the reconstructions will be completed in the order they are in on the CT Agent Queue

26) When CT Agent says Idle your scan has been reconstructed and saved