Surface-mounting thermostats ATH series

Similar documents
Panel-mounting Thermostats EM Series

Heating thermostat Series AMHs B Operating Instructions 11.06/

Surface-mounting thermostat, type series ATH.-SE to monitor seagoing vessel equipment

Surface-mounting thermostat, type series ATH.-SE

Panel-Mounted Thermostat

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Panel-mounting thermostats, type series EM

Bimetal Temperature Switch

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

TUC: Universal thermostat

Single Point Flow Monitor SW118 SW119

Panel-mounted Thermostats

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Mechanical flow switch for On/Off control

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Level Measurement silometer FMC 420, FMC 423

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Inductive sensor NI10-M18-Y1X-H1141

Explosion protected add-on thermostat

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor NI3-EG08K-Y1-H1341

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Flexibility and Safety. BERNSTEIN safety hinge switches

Pendant Light Fitting IEC Series 6470/2

Inductive sensor With analog output BI15-M30-LI-EXI

JUMO DELOS SI. Electronic Pressure Switch with Display. B Operating Manual /

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

7 Lighting Technology

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Okta 1000, Roots pump without motor

SERIES 400 SERIES 620

RSCC. Load cells. Special features. Data sheet

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Immersion Pumps HCT (High Chem) sealless

Gear Pump Units For single-line centralized lubrication systems

Pulse Counters, electromechanical

I Ex-protected connectors exlink I

Pressure transmitter COMPACT IO-Link,

Magnetic Stirrers Magnetic Stirr

Absolute Encoders Multiturn

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

82540/ /2-way diaphragm valves

DMP 331i / DMP 333i LMP 331 i

Series description: Wilo-Drain VC

Process transmitter RMA422

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LED Driver Linear / area fixed output

Gear Pump Units. For single-line lubrication systems

Linear flow control with actuator IFC

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Capacitance Level Measurement Electronic insert FEC 12

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Read/write head TN-M18-H1147

Pulse Counters, electronic

Connecting cables NEBS, for sensors

Capacitance Limit Detection nivotester FTC 420/421/422

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Linear flow controls VFC Linear flow controls with actuator IFC

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Kuhnke Technical Data. Contact Details

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

TFRN Industrial RTD temperature sensor. CombiTemp TM

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

3 Cleaning. 4 Technical data

Photoelectric Sensors E3F2

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Pressure transmitter For applications in hazardous areas Model IS-3

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Read/Write Head TN-M30-H1147

GRUNDFOS alldos product information. The solution for complex dosing tasks

KRF EMC Filters Installation, Operation and Maintenance Manual

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Filters for Power Lines (Low Leakage Current)

10 PDUs 19 PDUs Zero-U PDUs

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Selection matrix for electronic pressure switches

EXPlora. Introduction

PROPORTIONAL VALVES Sentronic plus

LED Driver Compact fixed output

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Transcription:

M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 4, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 66 6003-0 Fax: +49 66 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 0 TT, UK Phone: +44 79 635533 Fax: +44 79 6356 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO PROCESS CONTROL INC. 885 Fox Chase, Suite 03 Coatesville PA 930, USA Phone: 60-380-800-800-554-JUMO Fax: 60-380-8009 E-mail: info@jumousa.com Internet: www.jumousa.com Data Sheet 60.306 Page /9 Surface-mounting thermostats ATH series Protection IP54 Brief description Thermostats control and monitor thermal processes. Surface-mounting twin thermostats, ATH series, consist of two separate measuring and switching systems. The instruments are available as temperature controllers TR, temperature monitors TW, temperature limiters TB, safety temperature monitors STW (STB) and safety temperature limiters STB. In the event of a fault, the STB sets the system being monitored to a safe operational state. Surface-mounting twin thermostats operate on the principle of liquid expansion, with a microswitch serving as the electrical switching device. Switching function Temperature controller TR and temperature monitor TW When the temperature at the probe exceeds the selected setpoint, the microswitch is operated through a mechanism and the circuit is opened or closed. When the temperature falls below the setpoint (by the switching differential), the microswitch returns to its initial position. Lock-out facility on the temperature limiter TB and safety temperature limiter STB When the temperature at the probe exceeds the set limit, the circuit is opened and the microswitch locked out mechanically. After the temperature has dropped by about 0 % of span below the danger temperature (about 5% with limit setting > +350), the microswitch can be reset manually. Use of the safety temperature monitor STW as safety temperature limiter STB In this case, the circuit connected to the thermostat must comply with DIN 3440 and Section 8.7 of DIN/VDE 06. Self-monitoring on the safety temperature limiter STB and safety temperature monitor STW (STB) Failure of the measuring system on the STB and STW (STB) i.e. a leakage of the expansion fluid, will cause the pressure under the diaphragm to drop, thus permanently opening the circuit. A reset is now impossible. When the temperature at the probe cools down to below about -0, the circuit will also be opened. As the temperature rises to above -0 (approx.), the STB has to be reset manually, by pressing the reset button. On the STW (STB), the reset is performed automatically. Types and approvals ATHs- ATHf-70 You will find the Declarations of Conformity on the Internet at: www.jumo.net Products or they can be sent to you on request. Type with rigid stem with capillary Switching function DIN Reg. No. Test ATHs-0 ATHf-0 TR / TR TR / TR 8960 ATHs-0 ATHf-0 TR / TW TR / TW 8970 ATHs-70 ATHf-70 TR / TB TR / TB 8980 ATHs-0 ATHf- TW / TW TW / TW 900 ATHs-70 ATHf-7 TW / TB TW / TB 900 - DIN 3440 ATHs-0 ATHf-0 TR / STW (STB) TR / STW (STB) 8990 S ATHs-0 ATHf-0 TW / STW (STB) TW / STW (STB) 9030 S ATHs-70 ATHf-70 TR / STB TR / STB 9000 ATHs-70 ATHf-70 TW / STB TW / STB 9040 ATHs-00 ATHf-00 STW (STB) / STW (STB) x STW (STB) 9050 S - DIN 3440 ATHs-070 ATHf-070 STW (STB) / STB STW (STB) / STB 9060 S - Pressure Equipment Directive 97/3/EC ATHs-7070 ATHf-7070 STB / STB STB / STB 9070

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page /9 Technical data Control ranges and temperature probes Switching function Control/ limit ranges TR, TW and TB -50 to +030-0 to +050-0 to +040 +00to+050 +00to+070 +00 to +00 +0 to +090 +30 to +0 +0 to +0 +60 to +30 +0 to +50 +50 to +00 +50 to +50 +50 to +300 +50 to +350 STW and STB +30 to +0 +60 to +30 +0 to +50 +50 to +50 +50 to +300 TR, TW and TB +0 to +400 +0 to +500 +0 to +500 STW and STB +0 to +400 +0 to +500 +0 to +500 Max. permissible probe temperature 050 060 050 060 080 5 5 35 40 50 75 30 90 345 405 35 50 75 90 345 460 550 550 460 550 550 liquid-filled gas-filled Maximum capillary length mm 5000 5000 000 000 4000 000 000 4000 Probe length L in mm probe dia. d = 6 mm is standard 8 4 85 85 38 07 38 5 06 35 088 0 073 063 053 08 6 077 064 055 78 48 0 76 7 0 Capillary and temperature probe Type End of scale Capillary Temperature probe Notes ATH.-.. up to 00 copper (Cu).5mm dia. Mat. Ref..0090 Capillary length Min. bending radius of capillary Electrical data up to 350 up to 500 up to 350 copper (Cu).5mm dia. Mat. Ref..0090.5mm dia..5mm dia. standard: 000 mm, maximum: 5000 mm 5mm copper (Cu) Mat. Ref..0090 brazed brazed welded welded at extra cost Switching device TR, TW, STW (STB) TB (-7), STB (-70) TB (-7/U), STB (-70/U) microswitch with changeover contact microswitch with break contact and lock-out microswitch with break contact, lock-out and additional signal contact Rating 0 () A, 30 V AC +0%, p.f. = (0.6) 0.5A, 30 V DC +0% with switching differential.5% and % 6 (.) A, 30 V AC +0%, p.f. = (0.6) 0.5 A, 30 V DC +0% microswitch gold-plated, extra code /au 0. A, 4 V AC/DC contact resistance.5 0 mω

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page 3/9 Operating data Switching differential in % of control / limit range Switching point accuracy in % of control / limit range Ambient temperature error referred to control / limit range Permissible storage temperature Permissible ambient temperature in operation Nominal position (NL) Case Standard Switching function with liquid-filled measuring system Nominal value Possible actual value TR, TW 3 3 max. 4 standard 6 6 max. 8 on request.5 max. at extra cost with gas-filled measuring system 5 4 max. 8 standard 9 8 max. on request.5 max..5 at extra cost with liquid-filled measuring system STW (STB) 5 4 max. 6 standard 9 8 max. on request max. 3 at extra cost with gas-filled measuring system 7 5 max. standard 9 8 max. 6 on request.5 max. 3 at extra cost TR: in upper third of scale ±.5%, at start of scale ± 6% TW, TB, STB, STW (STB): in upper third of scale +0/-5%, at start of scale +0/-0% A deviation of the ambient temperature at the case from the calibration ambient temperature of produces a shift of the switching point: higher ambient temperature = lower switching point lower ambient temperature = higher switching point Surface-mounting thermostats with end of scale <00 00 350 > 350 500 TR / TW / TB STB/STW (STB) TR / TW / TB STB/STW (STB) TR / TW / TB STB/STW (STB) due to thermostat head, % per 0.08 0.7 0.06 0.3 0.4 0. due to capillary, % per per m length 0.047 0.054 0.09 0. 0.04 0.03 case cover: polycarbonate, impact resistant case base: die-cast aluminium, painted -50 to +50 max. +80 to DIN 6 57, NL 0 NL 90 (other NL on request) color: pebble gray RAL 703 color: anthracite RAL 705 Code a cover: die-cast aluminium, painted color: pebble gray RAL 703 Setpoint adjustment TR: switching point adjustable from the outside by turning the knob TW, TB, STB, STW (STB): switching point adjustable with screwdriver, after removing case cover Protection EN 60 59-IP54 Cable entry standard: clamping nipple M 0 x.5, for 8 0 mm cable diameter Weight approx. 0.8 kg Thermostat mounting on type ATHf-.. with capillary standard Code r b k thread M 8 x with locknut at case spigot, capillary exit at spigot by screws through base of case, capillary exit on side of case, cover and base in plastic mounting flange in sheet steel, capillary exit at case spigot wall bracket

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page 4/9 Process connection* Series ATHswith rigid stem * For other process connections and pockets, see Data Sheet 60.670. Note: Physical and toxicological properties of the expansion media which may escape in the event of a system fracture. ) At present there is no restrictive statement from the health authorities concerning any danger to health over short periods and at low concentrations, e.g. after a fracture of the measuring system. Connection diagrams End of scale up to 50 pocket U screw-in pocket with screw-in spigot G / Form A to DIN 385/ End of scale above 50 pocket UZ screw-in pocket with screw-in spigot G / Form A to DIN 385/ and extension, in order not to exceed the max. permissible ambient temperature of +80 at the case Series plain cylindrical probe A (standard) ATHfwith capillary pocket U (on request) screw-in pocket with screw-in spigot G / Form A to DIN 385/ and clip with fixing screw for securing the probe Material pocket U pocket UZ up to +50 CuZn (brass) is standard above +50 St (steel) is standard (CrNi on request) above +50 St (steel) is standard (CrNi on request) Fitting length S standard lengths: 00, 0, 50, 00 or 300 mm other lengths on request Immersion tube dia. D = 5 mm Control range with end of scale Dangerous reactions Fire /explosion hazard Ignition temperature Explosion limit % v/v Water contamination irritant Toxicological data danger to health < +00 no + 80. 7.5 yes yes ) no 00 +350 no + 490 3.5 yes yes ) no > 350 +500 no no no no no no no toxic I II I II 4 System I: with changeover contact Switching function: TR, TW, STW System II: with break contact and lock-out Switching function: TB, STB System I and II: with changeover contact Switching function: TR, TW, STW System I and II: with break contact and lock-out Switching function: TB, STB I II I II 4 4 4 4 4 4 System I: with changeover contact Switching function: TR, TW, STW System II: with break contact, lock-out and additional signal contact System I and II: with break contact, lock-out and additional signal contact Switching function: TB, STB

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page 5/9 Dimensions ATHs-, ATHs-0 with pocket U 3 L 7 SW hex 3 G 0 S D ATHs-7, ATHs-70 with pocket UZ 0 3 0 7 7 Ø90 7 SW7 a/f S approx. 9 ca. 9 D ATHf- Thermostat mounting as standard with plain cylindrical probe A, no pocket 7 SW4 a/f M0x.5 38 8 M8x L 0 d

Ø 7 M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page 6/9 ATHf-7/r, ATHf-70/r, ATHf-070/r with plain cylindrical probe A, no pocket 7 L d ATHf-/b, ATHf-0/b, ATHf-00/b with pocket U 7 7 hex G S L 6 0 Ø 6.5 65 D ATHf-/k with pocket U 7 43 M0x.5 0 hex 9 50 G S L D 80

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page 7/9 Order details Stock items with rigid stem Sales No. * model is being phased out Type Control / limit range Switching differential % (delivery 3 working days after receipt of order) Process connection Immersion tube dia. x length mm 60/600000 * ATHs- +00 to + 50 3-4 U G / 5 x 00 60/600037 * ATHs- +0 to + 90 3-4 U G / 5 x 50 60/60000486 ATHs- +00 to +00 3-4 U G / 5 x 0 60/6000009 * ATHs- +00 to +00 3-4 U G / 5 x 300 60/600038 ATHs- +0 to +50 3-4 U G / 5 x 00 60/6000008 ATHs- +00 to +00 3-4 U G / 5 x 0 60/6000045 ATHs- +0 to +0 3-4 U G / 5 x 50 60/6000007 ATHs- +0 to +50 3-4 U G / 5 x 00 60/6000049 ATHs- +00 to + 50 3-4 U G / 5 x 00 60/60000490 ATHs- +0 to + 90 3-4 U G / 5 x 50 60/6000006 ATHs- +00 to +00,5 U G / 5 x 0 60/6000047 ATHs- +00 to +00 3-4 U G / 5 x 0 60/6000555 ATHs- +00 to +00,5 U G / 5 x 0 CrNi 60/6000005 ATHs- +00 to +00 3-4 U G / 5 x 50 60/60000988 ATHs- +00 to +00 3-4 U G / 5 x 00 60/6000004 ATHs- +00 to +00 3-4 U G / 5 x 300 60/60000489 ATHs- +0 to +50 3-4 U G / 5 x 00 60/6000003 ATHs- +0 to +50 3-4 U G / 5 x 00 60/600000 ATHs- +0 to +50 3-4 U G / 5 x 300 60/600039 ATHs- +50 to +00 3-4 UZG / 5 x 00 60/6000098 ATHs- +50 to +300 3-4 UZG / 5 x 50 60/60005 ATHs- +0 to +500 5 UZG / 5 x 00 60/6000479 ATHs-0 +0 to +50 3-4 U G / 5 x 50 60/600093 ATHs-0 +0 to +0 3-4 U G / 5 x 50 60/6000009 ATHs-0 +60 to +30 3-4 U G / 5 x 50 60/6000008 ATHs-0 +30 to +0 3-4 U G / 5 x 50 60/6000095 ATHs-70 +30 to +0 3-4 U G / 5 x 50 60/6000096 ATHs-70 +30 to +0 3-4 U G / 5 x 00 60/6000048 ATHs-70 +0 to +0 3-4 U G / 5 x 50 60/60000989 ATHs-70 +0 to +50 3-4 U G / 5 x 50 60/60000 ATHs-70 +0 to +50 3-4 U G / 5 x 00 Stock items with capillary (delivery 3 working days after receipt of order) Sales No. Type Control / limit range 60/60000986 ATHf- +00 to +00 Switching differential % Capillary Process connection Probe dia. x length mm 6 x 07 60/6000046 ATHf- +00 to +00 6 x 07 3-4 000 mm A 60/60000987 ATHf- +0 to +50 6 x 88 60/6000876 ATHf-70 +30 to +0 6 x 5

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page 8/9 Order details for items not available from stock ATH series Order code () Basic type 60306--00 ATHs- TR/TR 60306--00 ATHs- TR/TW 60306--007 ATHs-7 TR/TB 60306--00 ATHs- TW/TW 60306--007 ATHs-7 TW/TB 60306--00 ATHs-0 TR/STW (STB) 60306--00 ATHs-0 TW/STW (STB) with rigid stem 60306--070 ATHs-70 TR/STB 60306--070 ATHs-70 TW/STB 60306--00 ATHs-00 STW (STB)/STW (STB) 60306--070 ATHs-070 STW (STB)/STB 60306--7070 ATHs-7070 STB/STB 60306--00 ATHf- TR/TR 60306--00 ATHf- TR/TW 60306--007 ATHf-7 TR/TB 60306--00 ATHf- TW/TW 60306--007 ATHf-7 TW/TB 60306--00 ATHf-0 TR/STW (STB) 60306--00 ATHf-0 TW/STW (STB) with capillary 60306--070 ATHf-70 TR/STB 60306--070 ATHf-70 TW/STB 60306--00 ATHf-00 STW (STB)/STW (STB) 60306--070 ATHf-070 STW (STB)/STB 60306--7070 ATHf-7070 STB/STB () Control / limit ranges -50 to +030 4-0 to +050 6-0 to +040 +00to+050 +00to+070 5 +00 to +00 4 +0 to +090 5 +30 to +0 4 +0 to +0 66 +60 to +30 43 +0 to +50 6 +50 to +00 63 +50 to +50 64 +50 to +300 45 +0 to +400 46 +0 to +500 (3) Switching differential 00 no differential (-7 TB / -70 STB) 5.5% of scale span (on TR + TW only) 0 % of scale span (on STW (STB) only) 30 3% of scale span (on TR + TW only) 50 5% of scale span (on TR + TW + STW (STB) only) 60 6% of scale span (on TR + TW only) 70 7% of scale span (on STW (STB) only) 90 9% of scale span (on STW (STB) only) (4) Capillary length (mm) 0000 ATHs no capillary 000 000 mm 000 000 mm 3000 3000 mm 4000 4000 mm 5000 5000 mm.... (special length, details in plain text) (5) Material of capillary 00 ATHs no capillary 40 Cu (copper) 0 CrNi (stainless steel.457)

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.306 Page 9/9 (6) Process connection * 0 A = plain cylindrical probe 0 U = screw-in pocket 30 UZ = screw-in pocket with extension (7) Thread of process connection * 00 no thread (process connection A) 3 external thread G / (8) Material of process connection 00 only with process connection A 46 CuZn (brass) 0 St (steel) 0 CrNi (stainless steel.457) (9) Fitting length S (immersion tube length) 000 ATHf no pocket 00 00 mm 0 0 mm 50 50 mm 00 00 mm 300 300 mm 400 400 mm... (special length, details in plain text) (0) Diameter D (immersion tube diameter) 00 ATHf- no pocket 5 5 mm () Diameter d (probe diameter) 6 6mm () Extra codes 000 no code 70 au snap-action switch contacts gold-plated 574 U TB / STB with break contact, lock-out and additional signal contact (basic type -7 TB and -70 STB only) 70 a case cover die-cast aluminium (not with code r) 7 r thermostat head mounting by screws through base of case, capillary exit on side of case, cover and base in plastic 764 b mounting flange in sheet steel, capillary exit at case spigot 48 k wall bracket * For other connection types and pockets, see Data Sheet 60.670. Order code () () (3) (4) (5) (6) (7) (8) (9) (0) () () () () /.. -.. -.... -.. - 00 -.. -.. -... -.. /. /... /... /... Order example 60306--00 / 43-30 - 000-0 - 0-00 - 00-000 - 00 / 6 / 48 / 000 / 000