EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

Similar documents
BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

PACS. Dark Current of Ge:Ga detectors from FM-ILT. J. Schreiber 1, U. Klaas 1, H. Dannerbauer 1, M. Nielbock 1, J. Bouwman 1.

EddyCation - the All-Digital Eddy Current Tool for Education and Innovation

Eddy current tools for education and innovation

Quadrupoles have become the most widely used

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

T sors, such that when the bias of a flip-flop circuit is

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Doubletalk Detection

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Characterisation of the far field pattern for plastic optical fibres

Normalization Methods for Two-Color Microarray Data

Steam Generator Tube Inspection I

Remote-Field Examination Using Array Sensors

Scout 2.0 Software. Introductory Training

Algebra I Module 2 Lessons 1 19

m RSC Chromatographie Integration Methods Second Edition CHROMATOGRAPHY MONOGRAPHS Norman Dyson Dyson Instruments Ltd., UK

EMC-Scanner. HR-series

Topic: Instructional David G. Thomas December 23, 2015

A New Standardized Method for Objectively Measuring Video Quality

Pre-Processing of ERP Data. Peter J. Molfese, Ph.D. Yale University

SIMET AVIKO D INSTRUCTION MANUAL SORTING Solutions, Ltd.

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

APPLICATIONS OF DIGITAL IMAGE ENHANCEMENT TECHNIQUES FOR IMPROVED

Electrospray-MS Charge Deconvolutions without Compromise an Enhanced Data Reconstruction Algorithm utilising Variable Peak Modelling

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

RGA13, 12/10/17 Ultra High Resolution 20mm Quadrupole with Dual Zone operation

Structural Diagnostics, Inc. Leaders In Automated Ultrasonic Testing. Immersion Tanks Large Gantries Custom Systems

Erasing 9840 and 9940 tapes

RG NDT INTERNATIONAL INC. Drill Pipe and Tubing Inspection System

DESIGNING OPTIMIZED MICROPHONE BEAMFORMERS

Advanced Test Equipment Rentals ATEC (2832)

4.9 BEAM BLANKING AND PULSING OPTIONS

Lecture 2 Video Formation and Representation

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background:

E X P E R I M E N T 1

FEASIBILITY STUDY OF USING EFLAWS ON QUALIFICATION OF NUCLEAR SPENT FUEL DISPOSAL CANISTER INSPECTION

CS229 Project Report Polyphonic Piano Transcription

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Affected Products: Product Line Category Device Version Machinery Health Management. Data Analysis

4830A Accelerometer simulator Instruction manual. IM4830A, Revision E1

Investigation of Digital Signal Processing of High-speed DACs Signals for Settling Time Testing

1996 Yampi Shelf, Browse Basin Airborne Laser Fluorosensor Survey Interpretation Report [WGC Browse Survey Number ]

Reduction of Device Damage During Dry Etching of Advanced MMIC Devices Using Optical Emission Spectroscopy

A COMPARISON OF Mll...LIMETER WAVE AND EDDY CURRENT DETECTION OF SURFACE BREAKING DEFECTS IN CONDUCTING MATERIALS

3.22 Finalize exact specifications of 3D printed parts.

TESTING METHODS AND RELIABILITY -POWER

Sources of Error in Determining Countermovement Jump Height With the Impulse Method

Advanced Test Equipment Rentals ATEC (2832)

CAEN Tools for Discovery

10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs

WVR500 Waveform/Vector Monitor

Experiment 4: Eye Patterns

Minimize your cost for Phased Array & TOFD

Advanced Techniques for Spurious Measurements with R&S FSW-K50 White Paper

NENS 230 Assignment #2 Data Import, Manipulation, and Basic Plotting

SPP-100 Module for use with the FSSP Operator Manual

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

PRODUCT SHEET

Agilent Technologies 54522A

On Figure of Merit in PAM4 Optical Transmitter Evaluation, Particularly TDECQ

RG NDT INTERNATIONAL INC

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

SC24 Magnetic Field Cancelling System

Connection for filtered air

2 MHz Lock-In Amplifier

Getting started with Spike Recorder on PC/Mac/Linux

Measurement Accuracy of the ZVK Vector Network Analyzer

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

SC24 Magnetic Field Cancelling System

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

PulseCounter Neutron & Gamma Spectrometry Software Manual

BER MEASUREMENT IN THE NOISY CHANNEL

APPLICATION OF PHASED ARRAY ULTRASONIC TEST EQUIPMENT TO THE QUALIFICATION OF RAILWAY COMPONENTS

Transducers and Sensors

Beam test of the QMB6 calibration board and HBU0 prototype

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

Signal Stability Analyser

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

Scanning System S-2100

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

THE OPERATION OF A CATHODE RAY TUBE

Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Agilent Feature Extraction Software (v10.7)

Waveform Monitor/Vectorscope, PM 5661 Waveform Monitor/Vectorscope, Sc-H, PM 5661/70

THE OPERATION OF A CATHODE RAY TUBE

Commissioning of the ATLAS Transition Radiation Tracker (TRT)

DIRECT DRIVE ROTARY TABLES SRT SERIES

Renishaw Ballbar Test - Plot Interpretation - Mills

Measurement of overtone frequencies of a toy piano and perception of its pitch

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

Tech Paper. HMI Display Readability During Sinusoidal Vibration

ENGINEERING COMMITTEE

Characterization and improvement of unpatterned wafer defect review on SEMs

Transcription:

EDDY CURRENT MAGE PROCESSNG FOR CRACK SZE CHARACTERZATON R.O. McCary General Electric Co., Corporate Research and Development P. 0. Box 8 Schenectady, N. Y. 12309 NTRODUCTON Estimation of crack length and depth is of considerable interest to the eddy current testing community, due to their importance in determining the relative severity of the flaw. A paper presented at the NTERMAG-MMM conference in July, 1988 proposes an automated method for estimation using eddy current image data where the material being tested is magnetic [1]. These estimates are within two to one of the correct results over a wide range of EDM slot sizes and aspect ratios, provided the slot length is at least half the mean coil radius. A second motivation for the present work is to provide a benchmark against which other techniques, or variations such as lower sampling density or different flying heights (fixed lift-off), may be measured. Since there is no obvious reason why the same methodology should not work for non-magnetic material tests, seven different sets of data on the twelve EDM slots in a calibration block were run thru a similar algorithm. A brief description of the algorithm will be given, then the data sets will be described, and the results (including some processing variations) discussed. MAGE PROCESSNG Very low spatial frequencies are removed from the raw data image, shown in the upper left of Figure 1., by least squares fitting a third order surface to the outer pixels, and then subtracting it. The 8 pixel wide frame mask of the upper right in Figure 1. defines which pixels to use (the white region); the resultant surface is shown in the lower right. Subtraction of this fitted surface yields the background flattened image in the lower left, also setting the background mean value to zero. This processing is similar to using a high pass filter with very low cutoff frequency. The frame mask also defines a region from which to gather background statistics. The standard deviation, for example, provides an estimate of the noise in the background of the image. The flattened image,see Figure 2. upper left, is then thresholded at 2.5 times the standard deviation found in the frame; this yields the positive signal mask at upper right in Figure 2. A negative signal mask shown in the lower left is similarly found; each of these masks is used to gather statistics. These statistics include the mean voltage in the masked region and the number of mask pixels; the product of these two is the ntegrated Signal (S) in volt-pixels. The S found in each row of the thresholded image is also recorded, and a plot of this is shown superimposed on each of the signal masks. The negative signal mask is then subtracted from the positive to create a ternary mask image used for display purposes only, as shown in the lower right of Figure 2. The Review of Progress in Quantitative Nondestructive Evaluation, Vol. Edited by D.O. Thompson and D.E. Chimenti Plenum Press, New York, 1990 773

Figure 1. Background flattening. Figure 2. Masking, data gathering. c.. t,, 774 e e e J t... ', t t Figure 3. Operators display, the four smallest slots.

thresholding and signal mask making operation, repeated three more times (for 5,, and 20 times the standard deviation) for each axis is shown in Figure 3., the operators display for the four smallest EDM slots in the set. n each of these the left two columns contain in-phase images, while the right columns are quadrature images. The top row has raw data images, the frame mask, and EDM slot size annotation; the second row has the flattened images, and a histogram of the frame pixels on a baseline equal to the peak to peak voltage in the image. The third row contains ternary signal masks made at the least threshold (left) and the next larger (right), while the last row has those next larger and the largest threshold (right). The frame mask was also used to gather statistics from the image thresholded at 2.5 times the standard deviation, for purposes of estimating the S noise in the thresholded image. TEST DATA SETS All data was taken on the same calibration block, whose nominal EDM slot dimensions are shown in Table. All slots are 3 mils, or slightly less, wide; this is just small enough so that signals should be very close to those of tight cracks of the same length and width. At the 2 MHz frequency used, skin depth in the block is about 16 mils. The transducer is a split core differential probe, with an effective coil mean radius of about 34 mils. All data sets have square pixels, 4 mils on each edge. They were taken at various gain settings, but are so normalized that all are referred to unity gain; they are effectively the input signals to the bridge detector. The high pass filter was set to 0 Hz. (DC) in all cases. The various data sets are represented on the graphs as OS, RO, NS, S1, 03, L5, and F9; the distinctions between them are: 1. OS and RO were taken in March-May 1986, using a stepping motor scanner with pillow blocks for bearings, and a Nortec 25L eddycurrent instrument, with six feet of cable between probe and bridge. The probe was in contact with the sample, and pressed lightly against it by a spring; the probe was stopped to take data for each pixel. These two data sets do not include the largest two EDM slots; there are only ten images per set. The lift-off signal was aligned with the negative real axis. 2. NS, S1, 03, L5, and F9 were taken on granite block mounted precision slides using servo motors and eddycurrent electronics which did not include lift-off axis rotation capability. The probe (with about six inches of cable to the bridge) was flown above the sample about 1.25+/-0.25 mils. These sets were taken four adjacent slots at a time, and later cut into 64 x 64 segments for processing. 3. OS, NS, S1, 03, L5, and F9 -- the split in the split core differential probe is approximately aligned with the length axis of the slot; the low pass filter was set at 0 Hz. for OS. 4. RO the split rotated approximately 90 degrees; 0 Hz. LPF. 5. NS -- low pass filter, 0 Hz; velocity 2 ips. 6. S1 -- low pass filter, 0 Hz; velocity 2 ips; following NS run, sample dismounted and remounted, flying height reset, and data taken on different day. 7. 03 low pass filter, 0Hz; velocity 1 ips. 8. L5 low pass filter, 30 Hz; velocity 1 ips. 9. F9 low pass filter, 0 Hz; velocity 4 ips. Table Slot Number 1 2 3 4 5 6 7 8 9 11 12 Slot Len mils 20 30 50 0 20 20 30 40 50 60 Slot Dep mils 5 5 20 15 20 25 30 Area sq-mils 50 0 200 300 500 00 0 400 450 800 1250 1800 775

RESULTS The integrated signals found with the positive and negative signal masks are both positive; they are added together to make a single number for each channel. These (in-phase and quadrature) are then averaged to find the rs for each EDM slot; Figure 4. shows this result plotted against slot area (length t ~ e s width) for one of the data sets. The logarithmic regression line equation expressed in calibration form is approximately AREA= (4.285 * S)**1.026 where AREA is in square mils if S is in milli-volt-pixels. Note that different pixel sizes may be handled by expressing rs in, say, mv-square-inches; this requires only multiplication by a constant, in this case 0.000016, and was not done. The expected accuracy of the area estimates may be assessed by dividing the true area into the estimate; Figure 5. shows this for all seven data sets (but note that the OS and RO sets have no data for the largest two slots). The lines at 2.0 and 0.5 are only for ease of v i ~ u a l evaluation. To assess robustness of this area estimating technique, all data sets were treated using the constants in the equation above, and Figure 6. shows the result. The most likely major cause for the significant difference between the OS-RO sets and all the others is the flying height difference. To estimate slot length, the the row by row S vector (shown overplotted on the masks in Figure 2.) is thresholded at 15% of it's peak ~ o determine the width at this point. The four pulse widths for each slot (positive and negative for in-phase and quadrature) are averaged, and a linear regression line found for the data set as in Figure 4. The expected accuracy of resulting estimates is indicated in Figure 7., where the data sets at, 20, 30, and 50 mils are slightly displaced (deeper to the right, shallower to the left) for ease of identification. Estimated 00... l =e... 15 c at in 'V e at.s ~ ~ 0 1 0 + - - - ~ - T - r ~ ~ T r - - - r ~ - T ~ r n ~ - - - 0 00 Slot Area (sq. mils) 000 Figure 4. Absolute values of the rs found with positive and negative masks are added, and in-phase and quadrature are averaged to produce a single point for each slot; the LS data set is shown above, with a least squares fitted regression line. 776

t.os v RO + NS xs1 OQL_ Ol5 o F9 0 00 Slot Area {sq. mils) 000 Figure 5. Division of the line and data of the accuracy to be expected from sq.-mils, the x is plotted slot. All data sets are shown. are for aid in visual estimation only. Figure 4 by true area shows this area estimate. At 0 slightly left of the 20 x 5 Dotted lines at 2 and 0.5 6 ~. - v ~ xg ' ~ i OQ_3..... O ~ L 0 1 +--.----r--r...--.-tttr-----.----.--.-t'"m...-r---.--r..,...--r"'l"'..., 0 00 Slot Area (sq. mils) - - - 0 ~ ~ - - 000 Figure 6. All seven data sets using a single arbitrary calibration equation. lengths for the NS point at 20 by 5 and the F9 point at by 5 are negative, and so not included. Note that estimates at 30 mils length and above are much better than those at 20 mils and below. Alternate length estimates may be used; for example, if the regression is logarithmic all length estimates are positive, but there is little net gain. A third way to estimate length and depth uses only the area estimate and assumes that all slots (cracks) are half-penny shaped; length is the diameter implied by twice the estimated area, and depth is half this. This is intuitively satisfying for slots small compared to probe diameter, since the convolution of probe and slot becomes less definitive as slot size 777

decreases. Accordingly, Figures 8. and 9. use the linear fit of Figure 7., and replace it with a half-penny estimate if the linear fit estimate is less than 25 mils (about 37% of probe diameter); depths are area divided by length if the half-penny model is not used. Points plotted in Figure 9. are slightly displaced at 5,, and 20 mils depth; shorter to the left and longer to the right. NOSE Data were taken so that the S in the frame area with a threshold of 2.5 times standard deviation is determined; this is referred to the whole image (multiplied by 4096/1792) to determine the expected S caused by noise. The mean expected noise in the OS, RO sets is about 2 mv-pixels (and the maximum point is about 6). The NS, 51, and F9 set means cluster at about 0.7 mv-pixels, and those of 03 and LS at 0.37. The maximum for the 60 points of these last 5 sets is below 2, and only 6 points are above 1; five of these are below 1.5. The scatter for all sets except F9 is 16 to 20 db (6 to times); the F9 set has less than 6 db (2 to 1) scatter. t.os + NS 003 OF9 VRO X S1 OL5 0 i 0::: 17 - - - - - -~- - - - - - - - - - - - - - - - - - - - - 0. 1 + - - - - - -. - - - - - r - - - -. - -.... - - - -. -. - - -,. 0 Slot Length (mils) Figure 7. Accuracy of length estimates; same method as area estimates, but calibration to a linear equation. The two missing points (at and 20 mils) actually gave negative estimates. DSCUSSON AND CONCLUSONS ntegrated Signal is quite robust as an estimator for crack (slot) area; in Figure 5. the S from the 1.25 mil flying height data sets are nearly indistinguishable, but actual thresholds may vary by 6 to 1 or more. The reason is observable in Figure 3. where mask sizes decrease less rapidly than the threshold increases until signal maximun is approached closely. Note in Figure 5. that the 7 data sets are quite consistent in l ocating the same points above and below the unity line; this implies physic s rather than noise dominates this location. At 0 square mils, t he x slot is below, and the 20 x 5 above. Similarly, the 20 x 20 usually plots below the 30 x 15, which is usually below the 50 x ; 778

t. OS v RO + NS X 51 oo:s c LS i 0 ~ a::: 0.1+---------.---.------,---.-----,..---..--"T-..---, 0 Slot Length (mils) Figure 8. Accuracy of length estimates using Figure 7. estimates except if such estimate is less than 25 mils, then use a half-penny estimate based on the Figure 5. area estimate. t. OS + NS oo:s o F9 v RO xs1 c LS 0 ~ a::: i 0.1 +--.----.--,..----.-..----,------,..----,-----, olo " Slot Depth (mils) Figure 9. Accuracy of depth estimates based on Figures 8. and 5. Note that the half-penny estimate provides both length and depth. 779

these five points indicate that length is somewhat more important than depth in determining integrated signal. Nevertheless, all these points are all between 71% and 125%; area estimation based solely on integrated signal works surprisingly well. Also note that the 40 x 20, 50 x 25, and 60 x 30 slots tend to indicate a possible droop; this probably comes from the increase in the ratio of slot depth to either skin depth or coil radius. The standard deviation multiplier which determines threshold was set inside the edge of noise, at 2.5, since small crack detection is desired. f the background noise is Gaussian, then the probability of equaling or exceeding this is 0.0124, and about 51 noise pixels should occur in each image; the mean of these estimates from 80 image pairs is 57., and standard deviation is about 40% of the mean. Further, the 6 mv-pixel maximum of the S noise estimates less than 28 sq-mils of crack area, while 2 and 1 mv-pixels indicate only 9 and 4.5 sq-mils respectively. Thus, RO and OS should provide reliable detection down to perhaps 35 sq-mil cracks, and the others down to 25 or possibly 15 sq-mils. n the smaller sizes the estimated size will be less accurate, but errors due to noise will increase the estimate and are thus conservative. Figure 7 illustrates graphically that slot (or crack) lengths less than mean coil radius (about 34 mils in this case) are poorly estimated as they become smaller; but the half-penny model is a reasonable assumption for small slots. Note that 1:1 and 4:1 ratios are included in the slots so treated in Figures 8. and 9. The S (ntegrated Signal) concept provides a fully automatable method for estimating crack size from eddy current image data, requiring only simple image processing steps. The most complex step is determination of the least squares fit to a third order surface using the frame pixels, which runs in the order of a second in modern computers. t is the simplicity and speed of the process that recommend it, instead of it's rather modest precision. ACKNOWLEDGEMENT Kristina Hedengren suggested the use of a multiple of the standard deviation for the threshold, and John D. Young designed, supervised construction, and integrated both scanning systems referred to. t is a pleasure to acknowledge their significant contributions to this work. REFERENCE [1] R.O. McCary and J.R.M. Viertl, "Automating an Eddy Current Test System for n-service nspection of Turbine/Generator Rotor Bores",EEE Trans. on Magnetics, Vol. MAG-24, No. 6, PP. 2594-2596 Nov. 1988. 780