High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group

Similar documents
Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Series description: Wilo-Drain VC

Series description: Wilo-Sub TWU 3 HS

Mechanical flow switch for On/Off control

Series description: Wilo-Jet HWJ

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

A PASSION FOR PERFECTION. OktaLine. The Power Pump Portfolio. Roots Pumps for Every Low and Medium Vacuum Application.

Okta 1000, Roots pump without motor

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

2.9 Sigma/ 2 Plunger Metering Pumps

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

STE Technic Project Engineering Services Trade Ltd. Co. General Information. Main Features. Proven Performance

Immersion Pumps HCT (High Chem) sealless

MVSI-TS. Technical features

Roots * RAS-J Air & RGS-J Gas Blowers. GE Energy

istep STEPPER MOTOR PUMP

AC diagonal module Ø 200 mm

Agilent High Capacity RV Pumps & Roots Pumping Systems

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Single Point Flow Monitor SW118 SW119

Solenoid valves VZWD, directly actuated

DLP200M 2 Relay Module for Heating and Cooling Plants

EVAPORATIVE COOLER. ...Simple Effective Inexpensive to operate Economical. MODEL EC2.5 EC to CFM Nominal Airflow

Revision 2.0 Parts List Minor

Solenoid valves VZWD, directly actuated

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

istep STEPPER MOTOR PUMP

Magnetic Stirrers Magnetic Stirr

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Duo 65 M, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Duo 65, 3-phase motor, 3TF, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Fluid Cooling P-BAR b Industrial BOL Series

Küba comfort DP. Draught-free ventilation and extremely quiet operation

LED Driver Compact fixed output

Revision 1.0 Parts List Minor

Absolute Encoders Multiturn

Panel-mounting thermostats, type series EM

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

P Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Compact fixed output

Type D mechanical diaphragm

Revision 2.0 Parts List Minette 1~, 3~

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Electric Rotary Modules. Rotary Actuators

PROPORTIONAL VALVES Sentronic plus

P Output Ratings. Dimensions and Weights. Prime Rating

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

P Output Ratings. Dimensions and Weights. Prime Rating

Ø50mm Shaft Multi-Turn Absolute Type

Orbit TM DIGITAL SHAKERS

P88-3. Output Ratings. Dimensions and Weights. Prime Rating

P Output Ratings. Dimensions and Weights. Prime Rating

TOSHIBA Industrial Magnetron E3328

P Output Ratings. Dimensions and Weights. Prime Rating

DLP600M 6+1 Relay Module for Heating and Cooling Plants

P Output Ratings. Dimensions and Weights. Prime Rating

P65-5. Output Ratings. Dimensions and Weights. Prime Rating

LED Driver Linear / area fixed output

Modular Lube Lubrication Systems System Controls

P Output Ratings. Dimensions and Weights. Prime Rating

GRUNDFOS ALLDOS DATA BOOKLET DDI DIGITAL DOSING

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

Features. Specifications. Finish. Notes

ROTARY EVAPORATOR BOECO ROTARY EVAPORATOR RVO 400 SD

SMALL OIL SEALED PUMPS

ACP 15 / 28 / 40 SERIES 2 COMPACT DRY ROUGHING PUMPS

Series CT7N Bimetallic Overload Relays

Panel-mounting Thermostats EM Series

Ratings at 0.8 power factor. Please refer to the output ratings technical data section for specific generator set outputs per voltage.

LED Driver Compact fixed output

P1000P1/P1100E1 50Hz

P800P1/P900E1. Output Ratings. Dimensions and Weights. Prime Rating

Pendant Light Fitting IEC Series 6470/2

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

DHK DHK-NW MEDIUM PRESSURE FRP CENTRIFUGAL FAN HIGH PRESSURE FRP CENTRIFUGAL FAN

P1350P1/P1500E1 50Hz

Duo 65 MC, 3-phase motor, 3TF, 230/400 V, 50 Hz 265/460 V, 60 Hz

Product Data Sheet 4656 EZ

Quality products from a single source

Immersion Pumps HCT (High Chem) sealless EN

PDP Series. Positive displacement dosing pump. Sandwich hydraulic diaphragm type with an internal relief-refilling valve SDI. The right dosing choice

Gamma instabus. Technical product information

Cylindrical Photoelectric Sensor CY-100 SERIES

Transcription:

High efficiency pumps with LCD display electronically controlled HEP Optimo L series, H2 product group indicate which mode has been active or selected. By pressing the activation pushbutton for more than 30 seconds, the pump is reset to factory default settings. 10 LED segments located around the outer dial show blue enlightened for the selected power values (10-100% of maximum curve). The display shows alternately head, flow rate and power consumption. In cases of disturbances the icon SERVICE lights and additional error codes shown on the display enable a rapid troubleshooting. DIP switches located in the Circulator terminal box can be used optionally for locking against unauthorized adjustment and/or for an activation of the night setback mode. Insulation shell included in delivery. technical data Rate of flow: 7 to 45 m 3 /h depending on model Pressure head: 6 m/8 m/10 m/12 m Control range: 6 to 760 W depending on model Media temperature: -10 C (non freezing) to +110 C Installation length: 180 to 340 mm depending on model Circulator connection: 1½ and 2 (threaded) DN 32, 40, 50 and 65 (flanged) Protection class: IP 44 Insulation class: F Nominal pressure: PN 10 Control Internal: External: pc + pv + + fixed rpm analogue 0-10 V Start/Stop (bridged terminal ex works) Omnibus fault message: Selector switch, potential free. product features High-efficiency wet running circulator with integrated automatic modes and additional eco mode for additional savings of approx. 40% compared to the best proportional pressure control. Convenient operation with multi-knob and dip switch. Optional night mode and locking against unauthorized adjustment. Clear display of function, setting and operating status via backlit icons and LCD display. Connection possibility of external control (0-10 V, start/stop signal) and omnibus fault indication. Numerous integrated additional functions (autom. air ventilation, softstart/inrush current limitation, anti blockage function, electronic motor protection against thermal overload). High-quality manufacturing and standard insulation shells. use The wet-running high-efficiency circulators HEP Optimo L+ have an electronically commutated synchronous motor with permanent magnet rotor and a continuously variable differential pressure control. They are designed for use in circulating systems with variable or constant flow. The inline pump housings are resistant to corrosion by a cathodic electrodeposition coating. The HEP Optimo L+ are designed for a static operating pressure of 10 bar. main areas of use Heating, air conditioning/refrigeration, solar, heat pumps and industrial facilities as dual pipe system boiler and primary circuit single pipe system storage loading circuit panel systems like underfloor heating materials Component Material Material no. Pump housing Grey cast iron, KTL EN-GJL-200 Impeller Plastic with fiberglass PSU-GF30 Shaft Stainless steel 1.4034 Bearing Ceramic/Graphite Can Stainless steel 1.4301 Insulation shell Polypropylen flow media heating water as per VDI 2035 pure, thin, non-aggressive and non-explosive, mineral oil-free media without solid or long-fibre components media with a max. viscosity of 10 mm 2 /s operating data must be checked above 20 % glycol temperature range Ambient temperature: 0 C to +40 C Temperature class: TF 110 Media temperature: -10 C (non-freezing) to +110 C ambient temperature To avoid condensation on the pump housing, the media temperature should always be equal to or higher than the ambient temperature (see table). Otherwise, as well as for temperatures from -10 C to +5 C, we recommend using a diffusion-tight insulation shell (see accessories). Ambient temperature Media temperature min. Media temperature max. 0 C 2 C 110 C 10 c 10 C 110 C 20 C 20 C 110 C 30 C 30 C 110 C 35 C 35 C 100 C 40 C 40 C 90 C motor protection An external motor protection is not required. The integrated electronic motor protection automatically reduces the power at overload. Simultaneously, a warning appears on the display. minimum inflow pressure To avoid cavitation noise and circulator damage the following minimum inlet pressure must be maintained at the pump suction nozzle. The values apply up to 300 m above sea level. Otherwise, a surcharge of 0.01 bar per 100 m time should be added. Media temperature < 80 C > 80 C to < 95 C Minimum inflow pressure 0,5 bar 1,5 bar sound pressure level The sound pressure level is 45 db (A). controls function With the multi-function button, all settings can be made easily and quickly. The multi-function button consists of an outer dial for the selection of the desired mode and the power set values, and an internal activation pushbutton for the programming start and for the confirmation of the selected mode or the power set point. Lit symbols in the motor cap Armstrong Fluid Technology

Technical data type connection pipe threaded connection flange installation length (mm) voltage / frequency p1 (w) i max (a) net-weight (kg) product no. hep optimo l+ 25-6.0 g180 1" 1 ½" 180 230 v 50/60 hz 6... 112 0.03... 0.50 4.6 0323-92060 0.20 hep optimo l+ 25-8.0 g180 1" 1 ½" 180 230 v 50/60 hz 6... 145 0.03... 0.63 4.6 0323-92080 0.20 hep optimo l+ 25-10.0 g180 1" 1 ½" 180 230 v 50/60 hz 6... 175 0.03... 0.80 4.6 0323-92100 0.20 hep optimo l+ 30-6.0 g180 1 ¼" 2" 180 230 v 50/60 hz 6... 112 0.03... 0.50 5.1 0324-92060 0.20 hep optimo l+ 30-8.0 g180 1 ¼" 2" 180 230 v 50/60 hz 6... 145 0.03... 0.63 5.1 0324-92080 0.20 hep optimo l+ 30-10.0 g180 1 ¼" 2" 180 230 v 50/60 hz 6... 175 0.03... 0.80 5.1 0324-92100 0.20 hep optimo l+ 30-12.0 g180 1 ¼" 2" 180 230 v 50/60 hz 9... 350 0.04... 1.50 6.4 0324-92120 0.20 hep optimo l+ 32-12.0 g220 dn 32 220 230 v 50/60 hz 9... 350 0.04... 1.50 9.3 0324-93120 0.20 hep optimo l+ 40-6.0 g220 dn 40 220 230 v 50/60 hz 7... 110 0.03... 0.48 8.0 0325-93060 0.20 hep optimo l+ 40-8.0 g220 dn 40 220 230 v 50/60 hz 10... 265 0.04... 1.15 11.1 0325-93080 0.20 hep optimo l+ 40-10.0 g220 dn 40 220 230 v 50/60 hz 10... 350 0.04... 1.50 11.1 0325-93100 0.20 hep optimo l+ 40-12.0 g250 dn 40 250 230 v 50/60 hz 46... 611 0.20... 2.70 20.3 0325-93120 0.20 hep optimo l+ 50-6.0 g240 dn 50 240 230 v 50/60 hz 10... 275 0.04... 1.20 12.6 0326-93060 0.20 hep optimo l+ 50-8.0 g240 dn 50 240 230 v 50/60 hz 10... 350 0.04... 1.50 12.6 0326-93080 0.20 hep optimo l+ 50-10.0 g280 dn 50 280 230 v 50/60 hz 38... 476 0.16... 2.10 21.0 0326-93100 0.20 hep optimo l+ 50-12.0 g280 dn 50 280 230 v 50/60 hz 46... 620 0.20... 2.70 21.0 0326-93120 0.20 hep optimo l+ 65-6.0 g340 dn 65 340 230 v 50/60 hz 15... 350 0.07... 1.50 16.6 0327-93060 0.20 hep optimo l+ 65-12.0 g340 dn 65 340 230 v 50/60 hz 55... 760 0.24... 3.30 29.5 0327-93120 0.20 eei performance curves hep optimo l+ 25-4.0 g180 hep optimo l+ 25-6.0 g180 hep optimo l+ 25-8.0 g180 hep optimo l+ 25-10.0 g180 www.armstrongfluidtechnology.com

hep optimo l+ 30-4.0 g180 hep optimo l+ 30-6.0 g180 hep optimo l+ 30-8.0 g180 hep optimo l+ 30-10.0 g180 hep optimo l+ 30-12.0 g180 hep optimo l+ 32-12.0 g220 Armstrong Fluid Technology

hep optimo l+ 40-6.0 g220 hep optimo l+ 40-8.0 g220 hep optimo l+ 40-10.0 g220 hep optimo l+ 40-12.0 g250 hep optimo l+ 50-6.0 g240 hep optimo l+ 50-8.0 g240 www.armstrongfluidtechnology.com

hep optimo l+ 50-10.0 g280 hep optimo l+ 50-12.0 g280 hep optimo l+ 65-6.0 g340 hep optimo l+ 65-12.0 g340 Armstrong Fluid Technology

18 dimensions (flange dimensions in mm) Combination PN 6 PN 10 Flanges ØD Øk n x d2 ØD Øk n x d2 DN 32 120 90 4 x Ø14 140 100 4 x Ø19 dimension illustration DN 40 130 100 4 x Ø14 150 110 4 x Ø19 DN 50 140 110 4 x Ø14 165 125 4 x Ø19 DN 65 160 130 4 x Ø14 185 145 4 x Ø19 dimensions (circulator dimensions in mm) type a (mm) b (mm) c (mm) d (mm) e (mm) f (mm) hep optimo l+ 25-6.0 g180 192 53 102 180 140 160 hep optimo l+ 25-8.0 g180 192 53 102 180 140 160 hep optimo l+ 25-10.0 g180 192 53 102 180 140 160 dimension illustration (threaded version) A B F R/G hep optimo l+ 30-6.0 g180 192 53 102 180 140 160 hep optimo l+ 30-8.0 g180 192 53 102 180 140 160 hep optimo l+ 30-10.0 g180 192 53 102 180 140 160 hep optimo l+ 30-12.0 g180 245 56 98 180 140 160 C D E hep optimo l+ 32-12.0 g220 245 65 110 220 140 160 hep optimo l+ 40-6.0 g220 192 70 110 220 140 160 hep optimo l+ 40-8.0 g220 192 70 120 220 140 160 hep optimo l+ 40-10.0 g220 255 70 120 220 140 160 hep optimo l+ 40-12.0 g250 382 76 135 250 206 240 dimension illustration (flange version) F A B G DN hep optimo l+ 50-6.0 g240 256 78 130 240 140 160 hep optimo l+ 50-8.0 g240 256 78 130 240 140 160 hep optimo l+ 50-10.0 g280 382 77 140 280 206 240 D E hep optimo l+ 50-12.0 g280 382 77 140 280 206 240 hep optimo l+ 65-6.0 g340 257 89 170 340 140 160 C hep optimo l+ 65-12.0 g340 387 100 170 340 206 240 www.armstrongfluidtechnology.com

for more information, contact your armstrong representative or visit us at: armstrongfluidtechnology.com/contactus toronto, canada +1 416 755 2291 buffalo, usa +1 716 693 8813 são paulo, brazil +55 (11) 4781 5500 birmingham, uk +44 (0) 8444 145 145 manchester, uk +44 (0) 8444 145 145 lyon, france +33 (0) 420 102 625 mannheim, germany +49 (0) 621 3999 9858 dubai, uae +971 4 8876775 bangalore, india +91 (0) 80 4906 3555 shanghai, china +86 (0) 21 3756 6696 armstrong fluid technology established 1934 armstrongfluidtechnology.com tm file no.:. date:., 201 supersedes: new date: new