Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin, M x, connector Electrical connection Transmitter +UB Receiver +UB Features Optical resolution mm Super-fast object detection, even with -way beam crossover Software-free adjustment of height monitoring Object identification using integrated object recognition Range 0 V Test 6 7 SC 0V C/Q H H H IO-link interface for service and process data 8 Teach-In Optional temperature range to -0 C Pinout Product information Release date: 0-0-0 : Date of issue: 0-0- 06_eng.xml The LGS automation light grid series detects objects ranging in size from small to large. The very slender light grids have a modular design and come in different beam spacings and field heights. All signal evaluation takes place inside the unit. The lightweight systems can be integrated in their surroundings in a well-designed configuration, which means that machines and plants in temperature ranges between -0 C...+60 C can be designed more compactly. Indicators/operating means 7 6 H F H H Q 0 9 8 8 7 6 Menu button yellow 7 Height checking yellow Operating indicator green 8 Object floating yellow Status display yellow 9 Crossing yellow Q object yellow 0 Peripheral beam tolerance yellow Height checking yellow nd level yellow 6 Height checking yellow OK button yellow nd level: Beam collimation, inverse mode, light-on/dark-on switching, reset factory setting, signal tracking USA: + 0 86 000 Germany: +9 6 776- Singapore: +6 6779 909
Technical data General specifications Effective detection range Threshold detection range Light source Light type Chipping Tuning-out of beam Beam spacing Standard : 0.... 6 m Option /: 0.... 8 m Standard : 7. m Option /: 0 m IRED modulated infrared light, 80 nm see Table, max. 00 mm Factory setting: -way, deactivateable adjustable max. fixed suppressible beam areas (blanking) mm Number of beams see Table, max. 9 Operating mode Emitter: Emitting power adjustable in two areas Optical resolution without beam crossover: mm with beam crossover:. mm with in % and 7% of the range Angle of divergence 0 Ambient light limit > 0000 Lux (if external light source is outside the opening angle) Functional safety related parameters MTTF d a Mission Time (T M ) 0 a Diagnostic Coverage (DC) 60 % Indicators/operating means Operating display Function display Controls Parameterization display Power on: LED green, statically lit, Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz), short-circuit : LED green flashing (approx. Hz) Emitter: Yellow LED, illuminates at high emitting power, off at low emitting power Receiver: Yellow LED: illuminates when an object is detected flashes when falling short of the stability control ( Hz) Error message: Yellow LED flashes (8 Hz) in emitter and receiver Receiver: pushbuttons for programming IO link communication: green LED goes out briefly (f = Hz) Electrical specifications Operating voltage U B 8... 0 V DC Ripple 0 % No-load supply current I 0 Transmitter : 0 ma Receiver: 0 ma (without outputs) Time delay before availability t v see Table, max.. s Interface Interface type IO-Link Protocol IO link V.0 Mode COM (8. kbaud) Input Test input Emitter switch-off with +UB or 0 V at pin (emitter) Function input Range input activation from.6 m (or m in case of option /) with +UB or 0 V on pin (emitter) Teach-in input for programming on pin 8 (receiver) Output Pre-fault indication output Switching type Signal output Switching threshold Switching voltage Switching current Stability Control (SC) PNP, short-circuit protected, reverse polarity protected on pin (receiver) Factory setting: dark ON, Switchable to light ON mode Switch output (detection field C/Q) push-pull ( in ) output, short-circuit protected, reverse polarity protected on pin (receiver), Height monitoring (H, H. H) push-pull ( in ) outputs, short-circuit proof, reverse polarity protected on pin, pin 6, pin 7 (receiver) Factory setting: The signal tracking for the threshold value is deactivated, increasing the optical resolution by a maximum of mm; switchable to active signal tracking max. 0 V DC max. 00 ma Voltage drop U d V DC Switching frequency f see Table, max. Hz Response time see Table, max. ms Timer function Off-delay programmable from 0.... s in ms steps (adjustment via IO-Link only) Ambient conditions Ambient temperature Storage temperature Mechanical specifications Housing length L Protection degree Standard : -0... 60 C (... 0 F) Option /6: -0... 60 C (-... 0 F) -0... 70 C (-... 8 F) see Table, max. 60 mm IP67 Accessories OMH-LGS-0 Attachment aid for light grid series LGS/ LGM OMH-SLCT-0 Quick clamp and adjustment system AA SLCT-0 Profile alignment aid OMH-SLCT-0 Mounting bracket including adjustment (with loose bearing) OMH-SLCT-0 Mounting bracket including adjustment OMH-SLCT-0 Mounting bracket including adjustment V-G-BKM-PUR-UL Cable socket, M, -pin, PUR cable V-G-BKM-PUR-UL Cable socket, M, -pin, PUR cable V-G-BK0M-PUR-UL Cable socket, M, -pin, PUR cable V-G-BKM-PUR-UL Cable socket, M, -pin, PUR cable V9-G-BK0M-PUR-IEC Cable socket, M, 8-pin, PUR-cable V9-G-BKM-PUR-IEC Cable socket, M, 8-pin, PUR-cable V9-G-BKM-PUR-IEC Cable socket, M, 8-pin, PUR-cable V9-G-BKM-PUR-U-V-G Connection cable, M to M, 8/-pin, PUR cable IO-Link-Master0-USB IO-Link Master IO-Link-Master-USB DTM Communication DTM for use of IO-Link- Master PACTware.X FDT-Framework IODD Interpreter DTM Software for the integration of IODDs in a frame application (e. g. PACTware) LGS-Serie IODD IODD for communication with LGS--IO- Link sensors Other suitable accessories can be found at www.pepperl-fuchs.com Release date: 0-0-0 : Date of issue: 0-0- 06_eng.xml USA: + 0 86 000 Germany: +9 6 776- Singapore: +6 6779 909
Connection Emitter: 00 mm connecting cable with -pin, Mx connector Receiver: 00 mm connecting cable with 8-pin, M x connector Cable cross section min. 0. mm Max. cable length 0 m Material Housing extruded aluminum section, Silver anodized Optical face Plastic pane, Polycarbonate Mass see Table, max. 70 g (per profile) Compliance with standards and directives Directive conformity EMC Directive 00/08/EC EN 6097--:007 Standard conformity Product standard EN 6097--:007 IEC 6097--:007 Approvals and certificates Protection class III ( IEC 60 ) UL approval culus Listed CCC approval Products with a maximum operating voltage of 6 V do not bear a CCC marking because they do not require approval. Curves/Diagrams Characteristic response curve Offset Y 800 700 600 00 00 00 00 00 0 0 6 7 8 x Distance X [m] y Release date: 0-0-0 : Date of issue: 0-0- 06_eng.xml Additional information Table : Switch-on delay, maximum switching frequency and maximum time delay before availability: without object parameterization with object parameterization, HQn outputs Max. switching frequency [Hz] Max. time delay before availability tv [s] typ. max. typ. max. 00 6 0.8 00 7 0.9 00 7 8 0.9 00 8 0.9 00 6 8 06.0 600 6 9 0.0 700 6 6 9 96. 800 6 6 0 9. 900 6 7 0 88. 000 6 7 8. 00 7 7 8. 00 7 7 78. 00 7 8 7. 00 7 8 7. 00 8 8 70. 600 8 8 67. 700 8 9 6.6 800 8 9 6.6 900 9 9 6.7 000 9 9 6 60.7 USA: + 0 86 000 Germany: +9 6 776- Singapore: +6 6779 909
00 9 0 6 8.8 00 9 0 7 6.8 00 0 0 7.9 00 0 0 8.9 00 0 8.9 600 6 0 9.0 700 6 9 9.0 800 6 0 8. 900 6 0 7. 000 6 6. 00 6. 00 6. Number of beams, housing length and weight: Safety information Number of beams Overall length of the transmitter/receiver unit The device must only be operated with Safety Extra Low Voltage (SELV) with safe electrical disconnection. Intervention and repairs must only be carried out by your suppliers. The system must be serviced and checked regularly. A clean, soft cloth can be used for cleaning. Aggressive, abrasive cleaning agents that damage the surface must be avoided. The device must not be subjected to hard knocks or vibration. Commissioning Prerequisites The transmitter and receiver must be installed and aligned correctly. The electrical connection must be established according to the connection diagram. Weight of the transmitter/receiver unit [g] 00 60 00 00 9 60 0 00 60 00 00 7 60 0 00 660 00 600 760 0 700 9 860 00 800 960 0 900 7 060 600 000 60 60 00 60 700 00 9 60 70 00 60 800 00 7 60 80 00 6 660 900 600 6 760 90 700 69 860 000 800 7 960 00 900 77 060 00 000 8 60 0 00 8 60 00 00 89 60 0 00 9 60 00 00 97 60 0 00 0 660 00 600 0 760 0 700 09 860 00 800 960 0 900 7 060 600 000 60 60 00 60 700 00 9 60 70 Design and function without object parameterization with object parameterization, HQn outputs Max. switching frequency [Hz] Max. time delay before availability tv [s] Release date: 0-0-0 : Date of issue: 0-0- 06_eng.xml USA: + 0 86 000 Germany: +9 6 776- Singapore: +6 6779 909
The signal output must respond to object detection. If at least one light beam is interrupted, the output remains active as long as the object is detected. Fault location Measure operating voltage Check the cabling. Check the transmitter and receiver for dirt and clean if necessary. Function displays Behind the optics cover on the connection side of the profiles there is a green Power ON operating indicator LED and a yellow status display LED. Transmitter Function Green operating indicator LED lights up statically Green operating indicator LED is dark and yellow status indicator flashes Yellow status indicator LED is dark Yellow status indicator LED lights up statically Yellow status indicator LED flashes quickly (approx. 8 Hz) Yellow status indicator LED light changes for short time Receiver Function Green operating indicator LED lights up statically Green operating indicator LED is dark Green operating indicator LED flashes with brief interruption Green operating indicator LED flashes ( Hz) Yellow status indicator LED lights up statically Yellow status indicator LED is dark Yellow status indicator LED flashes (approx. Hz) Yellow status indicator LED flashes quickly (approx. 8 Hz) Diagnostic description Power-On Power save mode Transmitter with low transmitting power Transmitter with high transmitting power Error condition Test input is activated Diagnostic description Power-On Power save mode IO-Link mode active, parameterisation only possible via IO- Link Error condition: Short circuit at the outputs Detection field interrupted Detection field is enabled. Insufficient function reserve Error condition: Incorrect signal measurement Resolution and beam clearance The mechanical beam clearance determines the smallest detectable object size. Crossing the light beams increases the resolution of the light grid. The devices are delivered without programmed height checking. The beam is crossed three times. Resolution of the crossed beam arrangement If three-way crossing of the beams is programmed, the resolution increases. For a three-way crossing, this means that the increased resolution is offered after % of the transmitter range or receiver range. It must therefore be ensured that all objects pass transmitters or receivers with this clearance. Release date: 0-0-0 : Date of issue: 0-0- 06_eng.xml.0 0.9 0.8 0.7 0.6 0. 0. 0. 0. 0. Object height scaled to emitter distance 0 0 0. 0. 0. 0. 0. 0.6 0.7 0.8 0.9.0 Distance from emitter scaled to emitter/receiver distance USA: + 0 86 000 Germany: +9 6 776- Singapore: +6 6779 909
Model number L G S x x x - y y y y - IO / z z z Options / extended detection range 8 m /0 Push-pull output, switch output 0. A, shortcircuit protected, reverse polarity protection /b with 0. m fixed cable and M connector /6 extended temperature range -0 C IO-Link-interface Detection field (min. 00 mm... max. 00 mm -> see technical data) Resolution (8 mm; 7 mm; mm; 0 mm; 00 mm) Release date: 0-0-0 : Date of issue: 0-0- 06_eng.xml 6 USA: + 0 86 000 Germany: +9 6 776- Singapore: +6 6779 909