Hardware installation

Similar documents
SECTION 4 TABLE OF CONTENTS

HD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity

Interactive Satellite Terminal Installation / Validation Manual

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

FOSC 450 C6 and D6 Closures

Optical Distribution Box 300 Installation Guide. Version : R0.0

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

3G-SDI Fiber Optic Digital Extension Modules in 19 1RU Frame

NewScope-7A Operating Manual

HCS - HES Cabling Systems

CAT6 Cable Tester. Operating Manual. Part No TRIAX - your ultimate connection

Coyote popup display set up instructions

Aerospace Fiber Optics

Procedure: Procedures: DIME TEAM: Drop # (circle one) Date: In Lab (either on Level 4, Level 6, or in shop): Installation: Functional Check

Interactive Satellite Terminal Installation / Validation Manual

Check what you have received against the component checklist and hardware above.

OWNER'S MANUAL SIGNAL COMMANDER

IP-LINX. Installation Guide

Main Products. Cable Assemblies Wire Harnesses Raw Cables. Connectors

AUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

EC Series Creativity Accessories Safety and Installation Guide

Assembly instructions

Toughsat Flyaway Users Manual

FIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.

HYPERLINE UTP/STP Cable Strippers and Cutters

HC20 Healthcare Kit Installation Instructions

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

2000 Series Weather Stations Analog Temperature / RH Sensor Upgrade Kit PRODUCT MANUAL KIT # 3613WDU

OWNER'S MANUAL SIGNAL COMMANDER

Assembly Instructions

WaterVue TV Installation & User Manual

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

Cable ISOBUS Active Termination

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ASSEMBLY AND INSTALLATION 3 ELEMENT 6 METER BEAM

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Chapter 4. Dish Antenna Installation. Installing a DISH 500 Antenna. Finding the Satellites

SUBCARRIER TRANSFER FILTER INSTRUCTION BOOK IB622702

IP-LINX Fiber :: X-XXXX

Power Injector 1520 Series

TKEY-K16. Touch CW automatic electronic keyer. (No moving parts no contacts) Assembly manual. Last review: March 15, 2018

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

TV Lift System Model CL-65 Installation Instructions

Check what you have received against the component checklist and hardware above.

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules

Instruction manual. Midi Fiber Dome. Instruction manual

1.8 METER SERIES 1183 Az/El MOUNT ANTENNA SYSTEM

Structured Cabling Introduction & Installation Guide

12G Broadcast connectors

INSTALLATION INSTRUCTIONS FOR

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

A CENTIMETER FM YAGI ANTENNA MHz

3M Distribution Box (DDB)

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

3M Fiber Optic Wall Mount Enclosure 8430 Series

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

ASSEMBLY INSTRUCTIONS

18mm ECAM Cable Entry Port

Electric Motorized Projection Screen PowerMax Tension Series

Ten-Tec (865) Service Department:(865)

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

SUHNER QMA SUBMINIATURE CONNECTORS

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

QUICK INSTALLATION GUIDE

Snail Fence InteleCell Deployment Guide

75 Elliptical Antenna System

Caution. Hanging the Screen:

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

Step 1. 2x Kep Nut 1x Left Motor Assembly

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

TracVision 95W LNB Installation

GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS. 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~)

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

UMN_ User Manual Antenna Simplex. TECHNO-MEDIA srl Via IV Novembre 92, Bollate (MB) tel

2100, 2200, 4100, 6200, MPB Series Side Mount Drive Package for Light Load 60 Hz Gearmotors

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

Data Sheet IP67 Mast Enclosure

epos & Security Essentials Trade ONLY ONLY Trade Catalogue Call us Now on Visit Our Website

Digital Active Outdoor DVB-T/T2 Antenna

Site Installation Model MP-8424

Site Installation Model MP-8433

Vibratory Deck Sieves 15 in. (380 mm)

Medium Box for Cable Termination

GENUINE PARTS. SIRIUS Under Glass Antenna Kit

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Coyote popup features

2000i. Projector Replacement Guide. for Projector Replacement Kits. NEC MT1060R ( ) and NEC MT860R ( ) Interactive Whiteboard

Step 1. 1x NXT Ultrasonic Sensor

LED Backlight for Technics amplifiers

Challenges. TETRIX Getting Started Guide STEM Challenge Building Guide. Step 1. Parts Needed. Tips

4320 SS-25 Self-Strip Terminating Block

Transcription:

Hardware installation 5. Place and fix the OMT to the interface without tightening the screws. Figure 291: Place and fix the OMT to the interface Note: Take care to place the OMT with the engraved ARROW indicating the pipe towards the pipe itself. 358 MPR-e

Installation Figure 292: Engraved arrow toward pipe 6. Install the MPT-HC V2/MPT-XP transceivers on the RF OMT. Note: Silicone grease must be put on the nose adapter O-ring when indicated in the manufacturer s installation instructions. If grease for O-ring is not mentioned, it must be avoided. MPR-e 359

Hardware installation Figure 293: Apply silicone grease Grasp the MPT-HC V2/MPT-XP by the handle and fasten it to the OMT with the four locking hooks that will be tightened onto the corresponding fastening brackets on the OMT. 360 MPR-e

Installation Figure 294: Locking hooks and fastening brackets Fine tuning procedure for polarization alignment The OMT to interface fixation screws must be tightened once the OMT body is in precise vertical position respect to the ground. Then, the antenna pointing procedure must be performed. It consists in finding the best antenna position to minimize the contra-polar received signal, acting on the pole mount tuning screws. After the antenna pointing procedure is completed, you need to apply the fine tuning procedure to one of the facing antennas to align the polarizations. Use the receiver on the polarization opposed to the transmitter on the facing antenna.to perform the fine tuning: 1. Switch to the cross polar receiver. 2. Slightly loosen the OMT to interface fixation screws. 3. Monitor the received cross polar signal and act on the special HEX spacer of the fine tuning mechanism of the OMT till the received signal power reaches its minimum (Power XP 30dB below the homopolar received signal). MPR-e 361

Hardware installation Figure 295: Fine tuning 4. Tighten the OMT fixing screws. Cable connections (MPT-HC V2/MPT-XP/9558HC) Electrical Ethernet cable If the PFoE has been implemented, only one cable interconnects the MPT-HC V2MPT-XP/ 9558HC with the Power Injector or MPT Extended Power Unit. To terminate the Ethernet cable (MPT-HC V2/MPT-MC/MPT-XP/9558HC side) and to pull it up from Indoor to MPT-HC V2/MPT-MC/MPT-XP/9558HC Warning: to make sure of the continuity and avoid short circuit, all cables / connectors connections such as RJ45, Coaxial, Ethernet, or Optical Fiber made on the field have to be verified and checked with Cable tester. The waterproofness must be also checked. To terminate the cable the kit plug R2CT must be used. The kit is made up of 10 items as shown in Figure 297. 362 MPR-e

Installation Figure 296: Kit plug R2CT Figure 297: Kit plug R2CT items Mating sequence instructions To terminate and to connect the cable to the MPT-MC follow the instructions: 1. Turn and remove the protection cap. MPR-e 363

Hardware installation Figure 298: Remove the protection cap 2. Partially unscrew the nut spiral. Figure 299: Unscrew the nut spiral 3. Pass the cable through the mini kit plug and crimp the RJ-45 plug according to the standard. Figure 300: Pass cable through the mini kit plug 364 MPR-e

Installation Figure 301: Crimp the RJ-45 plug Terminate the Ethernet cable according to the EIA/TIA 568B standard. Follow the instructions included with the connector. Figure 302: EIA/TIA standard 4. Insert the RJ-45 plug inside the unlocking clip NOTE: MPR-E doc says locking clip here--should probably be unlocking clip, judging by next step. Verify that the latch mechanisms are on the same side. Figure 303: Insert the RJ-45 plug in the unlocking clip MPR-e 365

Hardware installation 5. Pull the cable and insert the unlocking clip together with the RJ-45 plug inside the body, with the latches aligned with the body bayonet pin. Place the body arm on the left side. Figure 304: Insert the unlocking clip 6. If you need to hoist the assembly, pull the coupling nut to cover the plug body and return the protection cap. Figure 305: Pull the coupling nut 366 MPR-e

Installation Figure 306: Return the cap 7. Tighten the nut spiral with a 21 mm wrench with a torque of 3 N.m mini and 3.5 N.m maxi. The cable is now attached to the plug and ready to be pulled. Figure 307: Tighten the nut spiral Figure 308: Cable is ready to be pulled MPR-e 367

Hardware installation 8. Install the cable, partially unscrew the nut spiral and remove the protection cap to connect to the receptacle. 9. Align the two marks on the plug body and the receptacle, insert the plug body into the receptacle and rotate it clockwise. Figure 309: Align, insert and rotate the plug body 10. Connect the RJ-45 plug to its socket by pushing the cable. Figure 310: Connect the RJ-45 plug to its socket 11. Push the coupling nut and rotate it clockwise until it is secured to the receptacle. 368 MPR-e

Installation Figure 311: Push and rotate the coupling nut 12. Secure the assembly by screwing the nut spiral with a 21mm wrench with a torque of 3 N.m mini and 3.5 N.m maxi. Figure 312: Secure the assembly Unmating sequence instructions To perform the unmating sequence: 1. Unscrew the nut spiral using a 21 mm adapted wrench. Figure 313: Unscrew the nut spiral MPR-e 369

Hardware installation 2. Rotate and unlock the coupling nut. Figure 314: Rotate and unlock the coupling nut 3. Engage the RJ-45 unlocking clip forward until it stops. Figure 315: Engage the RJ-45 unlocking clip 4. Press on the unlocking clip latch. Figure 316: Press on the unlocking clip latch 5. Pull the clip and the cable rearward to disconnect the RJ-45 plug. 370 MPR-e

Installation Figure 317: Disconnect the RJ-45 plug 6. Rotate and disconnect the R2CT plug body. Figure 318: Rotate and disconnect the R2CT plug body Optical cable connection An optical cable must be used, if the PFoE has not been implemented. Note: First the SFP must be inserted in the MPT. The SFP is not included in the MPT. The cable is shown in Figure 319. The cable is a preassembled cable available in different lengths; see Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections. Figure 319: LC/Q-XCO to LC Fiber cord To pull-up the cable take a cord and insert it in the slot of the cable cap. Make a knot on the cord and pull-up the cable. MPR-e 371

Hardware installation Remove the cap and connect the connector to the LC+Q-XCO connector in the MPT-HC V2/MPT-XP/9558HC. The overlength of the optical fiber must be rolled up in the Cable overlength box. Fix the Fiber on the pole or the tower with UV tie raps. See Figure 320. Figure 320: Fiber cable overlength box For the 1+0 repeater configuration, LC/Q-XCO cable (3CC52169XXXX) is required for ODU-ODU connection. Power supply cable connection The power supply cable is a coaxial cable, which is used only if the optical cable is used to transport the Ethernet traffic. Two types of coaxial cables are available according to the length (less than 200 m or 200 m to 350 m). The coaxial cable must be connected to: Indoor side: to the Station battery through the Lightning protection + Low Pass Filter + Pigtail N-to-2 wires. See How to connect the MPT-HC V2 to the battery. ODU-side to the N-to-Ethernet pair pigtail (+ RJ45 + R2CT). The R2CT must be then connected to the relevant connector on the MPT-HC V2/MPT-XP/9558HC. For the termination of the cable with RJ45 and R2CT see Electrical Ethernet cable. 372 MPR-e

Installation Warning: The Power Supply connection must be made waterproof (see Type N connectors and grounding kits waterproofing on the IDU/ODU cables). Surround the connector with the auto amalgamate tape from up to down Surround the connector with the adhesive tape from up to down Put tie raps on the up and the down of the connector Cable connection in XPIC configuration The two MPT-HC V2/MPT-XP must be linked with the XPIC cable and with the RPS cable. The XPIC cable is a cat7 cable with proprietary connectors. Three lengths are available: 1 m, 2.5 m, 8 m, to be chosen depending on the way the MPT-HC V2/MPT-XP are installed. The RPS cable is an LC-LC optional jumper preassembled with Q-XCO (1m length). Figure 321: XPIC connector position MPR-e 373