Section 5.0: Lab Equipment and Setup

Similar documents
SPECIFICATION NO NOTE

SPECIFICATION NO Model 207 Automatic GTAW Welding System

4.9 BEAM BLANKING AND PULSING OPTIONS

Instruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER

Integre4. Audiophile integrated amplifier. v1.2

High-Current Hollow Cathode Development *

Single Point Flow Monitor SW118 SW119

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

Hamamatsu R1584 PMT Modifications

SRV02-Series. Ball & Beam. User Manual

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Data Acquisition Using LabVIEW

CATHODE-RAY OSCILLOSCOPE (CRO)

Signet 2250 Hydrostatic Level Sensor

AP P S e S rie i s ACE

515 PIPEMASTER. Features. Options PROGRAMMABLE POWER SOURCE FOR ORBITAL WELD HEADS

Westrex RA1713B Auxiliary Record Electronics

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

INSTRUCTION MANUAL COMMANDER BDH MIG

LAUREL ELECTRONICS, INC.

10-Channel 16-Bit Analog Board Set User s Manual And Troubleshooting Guide

SCALE & WEIGHT DISPLAYS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

NOTE ON PERFORMANCE TESTING

Interactive Virtual Laboratory for Distance Education in Nuclear Engineering. Abstract

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

JACK Digital HDTV Over-the-Air Antenna

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

OPTIMUM Power Technology: Low Cost Combustion Analysis for University Engine Design Programs Using ICEview and NI Compact DAQ Chassis

Fiberglass - Technical Data

OA White OA Black. Owner s Manual. Low Profile Digital HDTV Over-the-Air Antenna. w/built-in KING SureLock Digital TV Signal Meter

JACK Digital HDTV Over-the-Air Antenna w/built-in SureLock Digital TV Signal Meter

Owner s Manual. Backup Monitor System. LCD Monitor & CCD Color Camera

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

CITOCUT Plasma inverter cutting range

MICROPROCESSOR CALCULATION MODULE - S2000

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

CBF500 High resolution Streak camera

16-BIT LOAD CELL/DUAL STATUS INPUT

DMC550 Technical Reference

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

3M Sensored Termination (15 kv) QX-T15I-vi1-E

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Photovoltaic Module Installation Manual (IEC)

Nutube.US. 6P1 Evaluation Board. User Manual

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

E X P E R I M E N T 1

Cellular Signal Booster

Elements of a Television System

WELDING CONTROL UNIT: TE 450 USER MANUAL

Engineered to meet your needs T he oldest name in stud welding,

LUDLUM MODEL ALPHA-BETA SAMPLE COUNTER SERIAL NUMBER PR AND SUCCEEDING SERIAL NUMBERS. February 2016

Phono Amplifier brinkmann «EDISON» Manual.

Surge-Gap Drop Amplifier 1 GHz with 42/54 MHz Split

Contact data Anthony Lyons, AGELLIS Group AB, Tellusgatan 15, Lund, Sweden. Telefone:

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

SHARP Plasma inverter cutting range

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

ERALY & Associés. 4 Rue Georges Besse Bâtiment i FONTENAY-LE-FLEURY, France.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Operating Instructions

CITOCUT Plasma inverter cutting range

Photovoltaic Module Installation Manual (IEC)

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Cooling systems for ORBIMAT

Sentinel I24 Digital Input and Output Configuration

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

MODULAR DIGITAL ELECTRONICS TRAINING SYSTEM

The field cage for a large TPC prototype

PRESTOJET Plasma inverter cutting range

MTL Software. Overview

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

MinarcTig Evo 200MLP

Student Services & Classroom Addition

2x1 prototype plasma-electrode Pockels cell (PEPC) for the National Ignition Facility

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

FAST MOBILITY PARTICLE SIZER SPECTROMETER MODEL 3091

KEMPPI K5 WELDING EQUIPMENT. Kempact Pulse 3000 QUALITY, SPEED AND PRODUCTIVITY

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Bench Test Instruments and Handheld Oscilloscopes Basic Service

Front End Electronics

E-VENT. The turnkey plasma cutting machine. Technica l progress in the design

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DOME OPTIC SPLICE CLOSURE

Interaction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities

Teaching Plasma Nanotechnologies Based on Remote Access

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

COHERENCE ONE PREAMPLIFIER

Flash-Point with Closed Cup - Abel Method - ABA 4 (automatic)

Nitrogen Oxide Trace Level Analyzer (NOy) Minimum Specifications

10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs

These are used for producing a narrow and sharply focus beam of electrons.

SonoruS Audio. ATR10 Analog Tape Reproducer. Operating Manual

Transcription:

Section 5.0: Lab Equipment and Setup The following section describes the equipment and arrangement used in the Virginia Tech Plasma Torch Lab to conduct tests with a plasma torch using hydrocarbon feedstocks. The lab setup can be divided into four sections: flow system, data acquisition, power supply and safety equipment. A schematic diagram of the setup is shown in Appendix A. Although the arrangement of the lab varied throughout the testing process, the setup described below is considered to be the norm. Any deviation from this setup will be listed and explained for each test sequence, if applicable. 5.1: The Flow System The flow system is responsible for delivering the feedstock to the plasma torch at the correct flowrate. It consists of the gas storage cylinders (argon, ethylene, propylene and methane), dual-stage regulators, tubing and fittings, two mass flow meters, a dualchannel flow controller and the torch itself. Four gases were used to test the plasma torch operation: argon, ethylene, methane and to a limited extent, propylene. The gases were stored in high-pressure gas cylinders provided by a local vendor. Flow pressure was controlled by Victor dual-stage regulators, one of which is shown in Fig. 5.1. The regulators allow the flow pressure to be adjusted from 0-3.5 MPa. The pressure was generally set at 690-825 kpa. The regulators were custom designed for the gases listed above. Figure 5.1: Victor Hydrocarbon Regulator 43

All tubing in the flow system was made from 0.635cm (0.25in) Nycoil tubing connected by 0.635cm (0.25in) Swagelock fittings. The particular type of Nycoil tubing used is made from flexible nonconductive material with an operational pressure of 1.725 MPa and a burst pressure of 6.90 MPa. When both argon and a hydrocarbon gas are fed through the torch, the gases are combined using a T-fitting and then pass through 0.75 meters of the Nycoil tubing to assure adequate mixing. Two Sierra Series 840M mass flow meters were used to control the amount of flow to the torch. One flow meter was factory calibrated for argon and has a range of 0-20 standard liters per minute (SLPM). The second flow meter was factory calibrated for use with methane and has a range of 0-30 SLPM. When ethylene or propylene are used in place of methane, a calibration factor is needed to adjust for the different material properties of the gases. The equation used for calibration correction is as follows: Q act =Q m *K where Q act is the actual gas flowrate, Q m is the flowrate reading on the mass flow controller and K is a correction factor determined using data provided by Sierra Instruments. The correction factor is derived from the first law of thermodynamics applied to the sensor tube within the flow meter and is given by the following function, K = N1 ρ C 1 p1 ρ2c N where N is a correction factor for the molecular structure of the gas (monatomic, diatomic, etc.), ρ is the density and C p is the coefficient of specific heat. The conversion factor calculated using the above equation is for converting from the gas the flow controller is calibrated for, 2, to the new gas, 1. For the tests involving ethylene, K=1.20 and for propylene, K=0.564. The flow meters are shown in Fig. 5.2. The flow meter in the foreground is used to control the flowrate of argon, while the one in the background controls the hydrocarbon flowrate. Both flow meters rely on a large-diameter thermal mass flow sensor, which is virtually clog-proof. The flow meters utilized precision analog circuitry with a five-breakpoint linearizer, providing highly accurate calibration ability. Each flow meter is accurate to ±1% of full scale. The response time is generally one second to achieve ±2% of the required flowrate. 2 p2 44

Figure 5.2: Mass Flow Meters A 902C Dual-Channel Flow Controller, manufactured by Sierra Instruments, is used to control the two mass flow meters. It was factory calibrated to operate with the flow meters. The flow controller is shown in Fig. 5.3. Figure 5.3: Mass Flow Meters The face of the flow controller consists of a digital readout, readout select switch, two flow control potentiometers, rotary channel select knob and power switch. The flow control potentiometers allow the user to adjust the amount of flow through the flow meters. The readout select switch changes whether the digital readout displays actual flowrate or set flowrate for the channel selected by the rotary channel selection knob. Generally, these two numbers are identical unless there is a severe obstruction in the flow path. Control signals are sent to the flow meters using two-way parallel cables. Electrical connections on the back of the flow controller provide 0-5 volt outputs that can 45

be used to send signals to the data acquisition system. These signals can then be converted into flow readings and displayed on the computer monitor. 5.2: The Data Acquisition System The data acquisition (DAQ) system was assembled to collect and process the data taken during the testing series. The actual computer components consist of an IBM 486PC, a National Instruments TM AT-MIO-16E-10 multifunction analog and digital I/O data acquisition card, LabVIEW 4.0 software and three analog signal-conditioning modules. The three signal conditioning modules are a ±50mV, a ±10V and a Type K thermocouple input, each with a ±5V output. Visual data of the plasma jet was taken using digital and standard motion cameras, a Model 82-020 Series 0.5 Meter Ebert Scanning spectrometer and a Burle 1P28B Photomultiplier tube (PMT) in a housing. Current, voltage, pressure and temperature data were collected using a current shunt, a voltage dividing circuit, a Genisco Tech 0-100psig pressure transducer with a Measurements Group 2310 signal conditioning amplifier; a backup analog pressure gage; and a type K torch body thermocouple, respectively. For the majority of the tests, the thermocouple, current shunt and power supply voltage were connected to the analog signal conditioning modules. This provided signal filtration and isolation of the DAQ card and PC from any unanticipated surges in the power supply system. The pressure transducer and flow meter outputs are pre-conditioned, and therefore, run directly into the DAQ card through the use of a CB50 connector block (Fig. 5.4). 46

Figure 5.4: Data Acquisition Hardware The Burle PMT (highlighted in Fig. 5.5 by the arrow), was attached to the exit slit on the spectrometer. When acquiring spectrographic data, the output voltage from the PMT is connected to one of the signal conditioning modules. Normally, the three modules are used to collect voltage, temperature and current data, but for spectrographic tests the voltage module was used instead to read the PMT voltage. Figure 5.5: Ebert Spectrometer with Burle PMT The wavelength counter on the spectrometer is synchronized with a counter in the LabVIEW program (a data acquisition and processing program provided by National Instruments) in order to correlate the PMT voltage with the appropriate wavelength. The wavelength counter and the other spectrometer controls are shown in Fig. 5.6 47

Figure 5.6: Spectrometer Controls From left to right, there is a scan direction control knob, an end of scan indicator light, a fuse, the wavelength counter, a manual scan and shifter control and a HI-LO shift selector. As a check of the DAQ system, the analog pressure gage and a hand-held multimeter were used to verify that the DAQ readings displayed on the computer monitor were correct. This verification of the DAQ system was performed prior to each test series to insure that the data collected during those test runs were accurate. Also, for the first few tests of the project, a video camera was used as a form of data collection and validation. Replay of the tape at low speed helped to qualitatively evaluate the torch operation in a slower time scale. Problems, which occurred too fast for the eye to see, were easily evaluated on the replay and could later be corrected. An example of this was when arcing occurred in the back of the torch. The arcs were noticed on film and an insulator was designed to correct the problem. 5.3: The Power System The power system is used to generate and deliver sufficient power to ignite and sustain the plasma torch. It consists of four welding units connected in series and one high frequency starter box. This configuration provides an open circuit voltage of approximately 270 volts. The plasma torch can be run in either DC or high frequency mode due to the available power and flexibility of the system. 48

Two of the four welding units are shown in Fig. 5.7. Each one is a Miller Electric Constant Current, DC, SR-150-32. They have an open circuit voltage of approximately 67 volts and can produce 5-150 amps. Most tests were conducted at 40 amps or below, with the norm being around 30 amps. For future reference, current settings (0-100%) are reported when actual current was not recorded. (Ex. 10%=15A, 20%=30A, ) Each unit is equipped with a high frequency starter. High frequency starters induce a rapidly oscillating voltage signal to break down the voltage gap. Initiating an arc across a gap requires a much larger voltage than maintaining the arc, which is why the high frequency starter is needed. Once the arc is in initiated, the starter shuts itself off and the welder returns to DC mode. These starters were used in early tests to ignite the torch, but they proved to be problematic because of the great intensity of the high frequency signal produced, so an external high frequency starter box with variable intensity setting was obtained to alleviate the problem. Figure 5.7: Plasma Torch Power Supplies The external high frequency starter box used in all but the initial tests is shown in Fig. 5.8. The Miller Electric HF-251D-1 is equipped with a high frequency intensity selection knob (0-100%), remote switch and start/continuous selection switch. All tests requiring the use of continuous high frequency current were conducted at intensity levels of 5% or below and run on continuous high frequency. DC tests were started by applying a burst of high frequency to the plasma torch and then turning off the HF-251D-1. 49

Figure 5.8: High Frequency Starter Box 5.4: Safety Equipment When conducting any test resulting in plasma or flame generation it is necessary that safety equipment be kept close by. Measures were taken to ensure the safety of those in the immediate area when the plasma torch was in operation. Any form of arc generates large amounts of UV, which must be shielded to prevent eye and skin damage. A 1.27cm thick transparent Lexan sheet was placed in between the plasma torch test cell and the control room. This sheet had three purposes. First, it needed to be transparent to allow a clear view of the plasma torch operation. It also provided a moderate amount of UV protection. Most importantly, the Lexan sheet provided superior blast protection to that of standard glass or Plexiglas due to its high resistance to shattering. Also, when looking directly at the plasma torch while it was in operation, a welding shield with a tint level of 12.0 was used. The test cell itself also had safety measures built into it. The main portion of the test cell was built from a 25.4 cm OD x 0.953 cm thick steel pipe and located on the outside of the building. It had a 90 elbow with a one-meter extension to force the exhaust gases up above head level. It was also equipped with a rain hood. A fire resistant fabric, used to keep out weather and block any light that might alter spectroscopic readings, enclosed the rest of the test cell. This fabric was also shielded from the torch by a sheet of aluminum, painted flat-black to reduce reflection. A picture of the plasma torch in the test cell is shown in Fig. 5.9. 50

Figure 5.9: Plasma Torch in Test Cell 5.5: Plasma Torch Setup Unless a test required a specific torch modification, such as arc gap adjustment, the plasma torch was set up identically for each test. First, the electrodes were replaced if they showed sufficient wear to be inadequate for the current test series. Electrode wear was evaluated qualitatively, simply by looking at the shape and amount of electrode loss. Gas seals and thread sealants were replaced every time the torch was disassembled to ensure quality operation. Gap adjustment was made by the use of the plasma torch micrometer drive and a multimeter. The multimeter was connected across the anode and cathode to check for continuity. The cathode was forced to make contact with the anode by adjusting the micrometer drive until the multimeter showed no electrical resistance between the anode and cathode. The cathode was then backed out until continuity was broken. From this point, the cathode was backed out an additional 0.178mm (100 on the micrometer drive) as prescribed by Stouffer (1989). Once the gap adjustment was made, the torch was bolted onto a Plexiglas stand in the test cell used to electrically isolate the torch from lab equipment. The torch body thermocouple, inlet gas and pressure lines were then connected. With the power off, electrical connections were made by the use of jumper cables. One cable was attached to the pressure line (anode) and the other to a steel ring, specially designed for this type of power connection. 51

From this point, the feedstock was set and run at the desired flowrate and then the power supplies were turned on. Plasma torch ignition was initiated by a burst of high frequency current from the starter box. The starter box was then turned off and the torch was allowed to run only on DC. For tests requiring the collection of voltage and current data, the voltage and current leads were connected to the data acquisition system after the high frequency starter was turned off. Plasma torch power levels ranged from 1.0-4.0 kw for methane, ethylene and propylene. Methane and ethylene had average power levels around 2.2 kw, with the average of propylene being several hundred watts higher. Argon consistently operated below 1.0 kw, and could be run as low as 130 W. 52