OZONESONDE FLIGHT PREPARATIONS

Similar documents
WQ Series Water Quality Bench top Meters

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

DLP600M 6+1 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants

Gazer VI700A-SYNC/IN and VI700W- SYNC/IN INSTALLATION MANUAL

The amazing power of FiOS starts here.

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

Remote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

STANDARD OPERATING PROCEDURE:

Quick Reference Guide

BASIC PH METER BASIC PH METER KIT

MATRIX. 24Bit /192kHz ASRC Stereo Audio Processor MATRIX. 2-Channel 24-bit 192-kHz ASRC Desktop Digital Audio Processor CUBE.

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

INTRODUCTION This procedure should only be performed if the instrument fails to meet the Performance Check tests for Output Zero or Offset Accuracy

28 4K LED monitor. User Manual M284K

The Playful Invention Company. PicoCricket Troubleshooting. Version 1.2a

SC24 Magnetic Field Cancelling System

Vinmetrica SC-200 User Manual

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services.

SC24 Magnetic Field Cancelling System

Safety Precautions and Maintenance

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

RADIO FREQUENCY SYSTEMS

LASER TROUBLESHOOTING GUIDE

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

CRYSTAL-800 W IRELESS IOS APP

1 Unpack the projector. Quick Setup. EPSON PowerLite S1+ Your projector comes with the following items:

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

Checking the fluids of the cart

Part names (continued) Remote control

Introduction to Thermal Stimulator in ABL

Be sure to run the vehicle engine while using this unit to avoid battery exhaustion.

Installation Instructions

User Manual. May 2005 AIN LIGHT

User Manual V2.6. Omniksol WIFIKIT User Manual. Omnik New Energy Co., Ltd.

CN Remove the scanner assembly (X476 and X576 models) and all doors/covers.

UNIT-3 Part A. 2. What is radio sonde? [ N/D-16]

AcoustiSoft RPlusD ver

GEM Systems Magnetism Survey Tutorial Colton Dudley

User s Manual. 4X1 HDMI Switcher Part #: DL-HDS41

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any


FD Trinitron Colour Television

Game Show Physiology

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

DIGITAL PORTABLE RECORDER TRAINING MANUAL FOR COURT REPORTING OFFICERs

Setup Guide. Read me BefoRe unpacking!

MULTI CHANNEL AV RECEIVERSTR-DH750/STR- DH550

Quick Start Guide Operators

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

Total Chlorine Sensor

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

SCALE & WEIGHT DISPLAYS

OWNER'S MANUAL MODEL: DTV-2000 STANDBY/ON

Trinitron Color TV KV-XF21M80. Operating Instructions (1)

NewScope-7A Operating Manual

LINE IN, LINE OUT. Copyright 2007 Sony Electronics Asia Pacific Pte. Ltd. All rights reserved.

Owner's Manual PPA-1 Phono Preamp

Check our knowledge base at

Hardware Setup. HP Dual TV Tuner/Digital Video Recorder. Document Part Number:

Activity P27: Speed of Sound in Air (Sound Sensor)

Getting started with

OPTICAL POWER METER WITH SMART DETECTOR HEAD

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

IPad 4 REPAIR GUIDE. Version Edition

Getting started with

Trinitron Color TV KV-AZ21. Operating Instructions M (1)

Honeywell HomMed Wireless Scale Quick Reference Guide

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

User Guide

Quick Setup 1 Unpack the projector

Data Acquisition Using LabVIEW

LDG M-7600 External Meter for Icom IC-7600

MB5 Multibeam Activity Monitor

User Manual Color video door phone

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

Vasudevan Agilent 1100 Series HPLC w/ DAD & FLD Detector (nonbuffer

CAT5 VGA Extender. Mode 1 Mode 2

High Frequency/High Field EMDEX II Specifications

IPad 3 (glass) REPAIR GUIDE. Version Edition

This pocket guide is not intended to replace the instruction manual. Read the instruction manual thoroughly before operating the sampler.

LAUREL ELECTRONICS, INC.

Teacher s AIDE Training System. EZ Teach Silver Installation

ASE 369 K Measurements and Instrumentation. LAB #9: Impulse-Force Hammer; Vibration of Beams

A/V Equipment Manual

Notations Used in This Guide

MODEL PA II-R (1995-MSRP $549.00)

GET STARTED. For assistance, call us on or visit manhattan-tv.com/help

GWL/ Power Group Technology Solutions Stay Powered for the Future

MEGAPOWER. User s Manual MODEL ML130 DLP PICO PROJECTOR DLP PICO PROJECTOR

2 Connect your video source

Concord 4 GSM Module Installation Sheet

SET TOP BOX MODEL: GDB01SFV1 USER MANUAL

EPSON PowerLite 8100i/9100i Multimedia Projector

Colour Explosion Proof Video Camera USER MANUAL VID-C

PLASMA MONITOR (PT20 UVVis) USER GUIDE

Satellite Dish Installation Manual (Ver. 2) 1

E X P E R I M E N T 1

Transcription:

OZONESONDE FLIGHT PREPARATIONS

2 Table of Contents Notes... 3 A week before flight preparations... 4 Changing the sensor solution... 4 Measuring background current... 5 Day of flight preparation... 7 Closing the Styrofoam box... 9 Preparing the computer... 11 TrueTTY configurations... 11 O3 configurations... 12 Things that might go wrong and troubleshooting... 15 Preparing the ground antenna... 16

3 NOTES 1- The first step in preparing the ozonesonde for use is to check the overall performance of the instrument, and to charge the sensor with sensing solution (Appendix A in the original manual). Initial charging of the sensor should be done 3 days to 1 week before flight time in order to attain a low sensor background current. 2- You should also prepare the ozonesonde 1-20 hours before flight. If you haven t done so, you will have to rely in putting the chemicals last minute and the ozonesonde may not function the same way (according to the manual), but you can do it if you are not so concerned about data and are just performing other tests, etc. 3- We still do not have the calibrator for the ozonesonde, therefore we have been improvising in testing it and preparing for flight. This manual will give the procedures we currently use as our preparation for flight; 4- The preparation should be performed in a clean room at a temperature of 20-25 C 5- There are 4 steps (with sub-steps) in the ozonesonde manual that refers to calibration with the Ozonizer (the ozonesonde calibrator). Once you already have it, please refer to the Ozonesonde manual (pages 8-9) for steps a to d before charging the sensor (chemical cell) with solution. We are moving on to step e in the manual for this reason. P.S: REFER TO THE OZONESONDE MANUAL FOR DETAILED DESCRIPTION OF ALL TESTING AND PROCEDURES FOR FLIGHT. THIS IS AN ATTEMPT TO MAKE LIFE EASIER IF THE OZONESONDE TEAM IS ABSENT DURING OR BEFORE A FLIGHT.

4 A WEEK BEFORE FLIGHT PREPARATIONS 1- Unplug the sensor leads from the sonde electronic interface board and unscrew the chemical cell from the ozonesonde. DO NOT LOSE THE SHORTING PLUG!!! Use the proper sized pliers to pull the plastic caps from the cells and set it aside. Empty the compartments and wash it thoroughly with tap water; 2- Wash it again with distilled water. Wash the caps as well, making sure to inject distilled water in the Teflon tubes by using one of those plastic bottles with a tip (there should be one inside the ozonesonde box or in the electronics lab. Finally, clean the pump tubes with methanol; 3- The sensor cathode must always be charged first to allow cathode solution to permeate the sensor's ion bridge. There is an A marked with a black marker for the anode cell. Using a Teflon-tipped syringe especially reserved for use with cathode sensing solution (inside a plastic bag in the ozonesonde box HARBOR room), inject 3.0 ml of the solution into the sensor cathode chamber. WAIT 2 MINUTES BEFORE PROCEEDING WITH THE ANODE SOLUTION to allow the cathode sensing solution to permeate the sensor s ion bridge. The solutions (anode and cathode) could be in the dark room (electronics lab) or inside the ozonesonde box in the HARBOR room. They are brown (dark bottles) because the solutions are sensitive to light. Agitate them before using. Make sure to clean the syringes after use with distilled water. When re-installing the top plug of the cathode, make sure that the air intake tube is correctly centered within the cathode chamber by inserting the tube carefully over a thin

5 Teflon rod projecting out of the bottom plug of the sensor cathode chamber. IT IS A VERY FRAGILE ROD! Note: Do not attempt to fill or empty the sensor cathode through the short air exhaust tube of the cathode chamber top plug; otherwise the platinum screen may be damaged (distorted), leading to sensor malfunction. 4- After waiting 2 minutes, use a syringe especially reserved for dispensing anode solution to inject 1.5 ml anode sensing solution into the sensor anode chamber. Rinse the syringe with distilled water prior to storage. 5- After charging the sensor with solution, screw the chemical cell back on the ozonesonde and run the sonde on ozone-free air for 5-10 minutes. If you still don t have the Ozonizer, improvise by using a box of some sort to cover the ozonesonde. Please do the following: a. Take the ozonesonde from the foam box. Disconnect the sensor leads from the electronics board and connect to the DMM labeled O3 (on the bottom), usually located at last station in the electronics lab, or use another one that is accurate to hundredths of microamps. Make sure it is set to measure microamps (current). Finally, cover the ozonesonde with the box, over the DMM leads, leaving very little space for air to go in and tape it all around. I usually use one of Dr. Sohl s plastic storage box that contains used batteries. It is usually located in his electronics lab. Any box will do it though, as long as it has no holes b. Monitor the levels of ozone in the computer (see next section for instructions on how to set the system for flight). When it reaches a number that is as close to zero as possible, let it run for 10 minutes and watch the current. It should not be more than 0.5 µa. It has never been over 0.2 µa for me.

6 c. Now we need to test for high levels ozone current. Take the box off and spark high voltage with the Tesla Coil Dr. Sohl has in his lab. Be extremely careful because there is no switch button and it hurts if you have an accident! Spark it on a metal (like the chairs around), as close as possible to the ozonesonde pump. Observe the current in the DMM. When it reaches 5 µa, keep it around that number for about 5 to 10 minutes, or as long as possible up to 10 minutes. Stop and immediately put the box back. Count 1 minute and watch the current. It should have dropped to 1.5 µa or less. Remember that these steps are being done in an unusual way and differences may occur. I have been able to obtain the expected result or very close to it though. This test will indicate satisfactory performance of the ozonesonde. d. Allow it to run for 10 more minutes inside the box and turn it all off. Disconnect the leads from the electronics board and short them with the plug. e. Open the cathode chamber again and insert 2.5 ml of cathode solution. Close it and store the ozonesonde in a dark room until the day of flight (up to 20 hours before).

7 DAY OF FLIGHT PREPARATION (1-20 HOURS BEFORE LAUNCH) 1. Use old batteries for testing and replace the batteries right before flight!!! 2. For details in how to change the solutions and measure background current, refer to A WEEK BEFORE FLIGHT PREPARATIONS above. 3. Change cathode (3.0ml) and anode (1.5ml) solutions as previously instructed; 4. Measure pump pressure by using the barometer (ozonesonde box in HARBOR room). To do that, disconnect the Teflon tube from the pump (the one that connects the pum to the chemical cell) and turn on the ozonesonde. The pressure should be above 8psi or else disregard sonde. 5. Measure and record background current on low ozone air as previously instructed (inside box). You will need this information to input into the O3 program before flight! 6. Expose ozonesonde to 5 microamps ozone for 10 minutes. 7. Measure decay time (as previously instructed); 8. Measure T100 flow rate - this test has not been performed yet, but there are instructions in the manual (Flow Rate Test). The apparatus is in the ozonesonde box (HARBOR room). Refer to original ozonesonde manual for complete instructions;

8 9. Record room temperature and humidity (use HARBOR sensor). You will need this information to input into the O3 program before flight. 10. Prepare the laptop (instructions on page 8) and antenna (there should be a team preparing the antenna). If nobody, refer to page 14 in this manual); 11. Connect radiosonde to ozonesonde. Connect cell leads to board. There is a filter we should run 4-10 minutes before flight, but we haven t done that yet. The filter is inside the ozonesonde box (HARBOR room);

9 Metal box that covers the electronics board Ozonesonde picture 12. Replace the metal cover on ozonesonde (look into the picture above); 13. Place ozonesonde instrument inside Styrofoam box. Make sure everything follows the proper positioning inside, marked in black for center of mass; 14. Make sure the radiosonde and ozonesonde have new batteries before flight; 15. Close the box for flight as follow:

10 16. Run ozonesonde outside to obtain 5-10 minute surface ozone measurement. 17. Attach to balloon train. 18. Check that Antenna is down. 19. Release ozonesonde. Record GMT date and time of launch. 20. Track data through ascent and on descent until signal fades. 21. Recondition ozonesonde for next flight (refer to original ozonesonde manual for instructions). Reject Sonde if: 1. Background is >0.10 microamps. 2. Background is negative < -0.02 microamps. 3. T100 time is <24 seconds, or > 34 seconds test has not been performed yet 4. Pump pressure is < 8 psi. 5. Pump current is > 125 milliamps (can be measured using the O3 program)

11 PREPARING THE COMPUTER 1- Open Nathaniel s laptop (or another laptop that contains the entire ozonesonde system); 2- Open the folder (that should be on desktop for easy access) Ozonesonde or similar. All the needed programs executables will be right there; 3- Open VSPE it s the virtual port emulator. If it asks to purchase the license, ignore it and say no. a. Click on create new device it s a connector icon with a red star. b. Choose pair and click next ; c. Choose any two different ports and click finish. It should say ready under status. Minimize the window and go back to the ozonesonde folder. 4- Open TrueTTY it s the software that substitutes the modem. It will decode the signal and send it to the O3 program. Follow the instructions in the chart next page. Intermet RSB1 is our Radiosonde brand. The setup option should be already all correct, but double check.

12 5- Still on TrueTTY program, make sure that you set the correct COM port you assigned in your VSPE. You are sending the signal from TrueTTY to the O3. So, if you set COM1 and COM2 in your VSPE program, you can designate COM1 for TrueTTY and COM2 for the O3 program (which is the next we will open). 6- Open the O3 program. Press start button. a. Change anything you want to change in that window: Name, latitude, longitude, and altitude. b. Click on Radiosonde menu. Change the info if wanted. c. Click on Ozonesonde label. The information you need to input is with the ozonesonde, on the metal cover that protects the electronic s interface: d. The two files needed for background current correction and pump efficiency should be already correct. The overall configuration should look like this:

13 e. Click on Acquisition and make sure you have the correct COM port (once more). We usually leave it as COM2, as we set the VSPE pair to be COM1 <-> COM2. Once more, the file should be already correct as this won t be the first time setting that laptop for flight.

14 7- Open a sound recorder program. We should have Audacity installed in the laptop. Record the signal the entire flight as a backup. The O3 and TrueTTY can decode the signal again from the recording in case there is any problems with TrueTTY or O3 during flight. a. Save the file if you need to reboot it or if you are done recording. Save it as a.wav file. Do not save it as a lower quality recording. It won t be decoded if you do so.

15 THINGS THAT MIGHT GO WRONG AND TROUBLESHOOTING Really, anything could go wrong. I will try to describe problems we have encountered during my stay and how I solved them. Remember that TrueTTY uses the sound card of the laptop. Keep that in mind if things go weird. Also remember that signal-to-noise ratio is crucial to the O3 program and if it s not high enough, it won t work even if you can clearly hear the signal coming through the receiver and see it in the screen. Yes, it s extremely sensitive. 1- The signal appears to be upside down (visually) in the TrueTTY screen (and there is no signal going through O3) this may happen all of a sudden, during transmission: a. Restart TrueTTY. b. If it doesn t help, restart the computer. SAVE THE.WAV FILE FIRST!!! 2- Everything looks good, but there is no virtual LED light flashing in the screen of the O3 program for either the radiosonde or ozonesonde (or both): a. Check the signal going through the TrueTTY screen (if not inverted or weird); b. Check battery levels for the radiosonde and ozonesonde; c. Check battery level of receiver (should be connected to power); d. Check battery level of pre-amp; e. We have had evaporative cooling happening during vaccum chamber tests. It never happened during a flight, but it s a possibility. There won t be any signal coming because the chemical cell will evaporate and leave a frozen solid behind. It s a salt solution (potassium iodide solution). f. Check ground antenna position; g. If no signal at all, pray! We have lost the entire ozonesonde box before.

16 PREPARING THE GROUND ANTENNA The ground system is composed of a yagi antenna that has a pre-amplifier connected to it, a receiver that attaches to the antenna via a coaxial cable, and a laptop (previously prepared for the ozonesonde system). The receiver connects to the laptop via an audio cable that comes from the push-to-talk. The audio cable connects to the microphone input in the laptop. Dr. Sohl knows how to connect the preamp to the antenna and the antenna to the receiver, in case you are not familiar with it.