Mosaic TM Dimmer 3 x 1000 W

Similar documents
ArteorTM Dimmer 3 x 1000 W / /60

Aspect 2 Circuit Digital Scene Control

Luminaire installation box Surface-mounted box Ceiling installation box

Operating Instructions Dimmer for V Incandescent Lamps

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

SceneStyle2 User Guide

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

15 Series - Dimmer

4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.

Figure 1: Device components

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

KNX Dimmer RGBW - User Manual

12months. on-site warranty. DZE ELECTRONIC PRESSURE SWITCH for detection of overload per EN 81 2 featuring two adjustable switching points

Operating instructions III / 2004

INSTALLATION & USER GUIDE

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

IP Roombox. Hotel Room Management

Instruction manual. DALI Gateway art Installation manual

Cyclo Series. user manual. MartinArchitectural

1440/2880 HP RGB+WW+CW

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Dimming actuators GDA-4K KNX GDA-8K KNX

ORDER CODE: EQLED65 USER MANUAL

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. KNX LED dimmer Constant voltage 4gang with power adaptor 6155/40-500

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

Manual for WMR-252 built-in receiver with universal dimmer

Gamma instabus. Technical product information

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

General FAQs Status as of: 22/10/2018

Mains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.

WE-EF LEUCHTEN. Technical information for Eco Step Dim Basic. Product ID

OPERATING MANUAL. DMX LED Current Dimmer 5004A-EP Mk2

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

HEX16 Strip User Manual

Model Number ALS-ELUM-RGB-CNTRL-1. elum RGB Controller

PIXEL TOUCH PCB KEEP THIS MANUAL FOR FUTURE NEEDS

STX Stairs lighting controller.

User Guide. Centrex Recording Interface

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Modular pulse operated latching relay 16 A

KNX / EIB Product Documentation. DALI Gateway. Date of issue: Order no Page 1 of 136

LT-300 LED Controller

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

RADIO RECEIVER RGB CONTROLLING LED STRIP COMMON ANODE

2-output DALI controller

Schneider Industries SAS MTN5812../MTN MTN Time switch

GreenParking. Commissioning guide. GreenParking

Tempus Lux Digital Photoelectric Switch D GB CZ BZT Installation and operating instructions BZT27731

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

Tri-level Control HF Sensor

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

RADIO RECEIVER RGB CONTROLLING LED COMMON KATHODE

LIGHT COPILOT II. elationlighting.com Internet:

Benefits. Applications

TABLE OF CONTENTS PART 5 APPENDIX TROUBLE SHOOTING MAINTENANCE A CTIVATE THE PASSWORD...13.

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

10 SERIES. Light dependent relays A

Tebis application software

Operating instructions. Universal timer switch display

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

Spacer System dimmers and switches

7 Day Digital Light Switch with Optional Dusk Start

Controller DMX DC-1224

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

CT-DMX-300 LED Controller

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Stratos Duo RGB. User Manual. Order code: EQLED371

Maestro 0 10 V Dimmer Sensor

CHALICE PENDANT LED DOWNLIGHT 70 Watt LED

EN Wireless programmable thermostat

User Manual. AtlonA. 1 x 10 VGA with Stereo Audio Distribution Amplifier over CAT5/6 compatible with AT-VGA300RL AT-VGA10SS

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

120cm (4x36 Watt) incl. Splitter Instruction Manual

DR4018 DIGISWITCH HANDLEIDING / MANUAL BEDIENUNGSANLEITUNG / MANUEL. DR4018 DIGISWITCH (v1.2) V1.2 ( )

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

Ariadni Dimmer For 250W CFL/Led, 600W Inc/Hal, or Lutron Hi-Lume A-Series Lte Led Driver, Clamshell Packaging In White

USER MANUAL Table of Contents

Artistic Licence. moody & moody cv. User Guide. Download the user guide by scanning the following QR code: moody & moody cv User Guide.

WING WHITE LED WALL WASHER

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

pixelpatt Light source 7x 30W RGBW multichips Effects Individual control of each RGBW pixel, Tungsten lamp emulation

Casambi App User Guide

SPEED LABOLIGHT. Instruction Manual

PART 1 PRODUCT (GENERAL)...1.

Operating Instructions BRONCOLOR SIROS

USER S Manual NGLT104WPD NGLT150WPD LCD TV / Monitor (IP67 Grade)

AYCL253PBR Ariadni 250W Led 3WAY Dimmer Brown

Transcription:

Mosaic TM Dimmer 3 x 1000 W 784 30 Technical characteristics (1) ( * ) 50/60 Hz 240 V~ 100 V~ 1 x 2,5 mm2 2 x 1,5 mm 2 Max. Min. Max. Min. < 2200 W (2) (do not exceed 1000 W per channel) 3 x 40 W < 1100 W (2) (do not exceed 500 W per channel) 3 x 20 W ( * ) Use only transformers which are intended for use with an electronic switch. (1) Important: See page 4, "Specific intended programming". Special provisions (see page 5) Operating current 0-10 V max. (sum of currents provided by ballasts): 50 ma Max. inrush current on contact closure at 240 V~: 120 A 20 ms (2) It is expressly forbidden to combine loads with ferromagnetic and with electronic transformers on a same channel. Choice of scenario (A, B, C, D) factory preset, customizable (see page 6). LEARN button 3 channels - Switching on and off - Light dimming +/- Programming buttons for channels A, B, C LEARN indicator light Infrared sensor (Enables remote control using Cat. No. 78431) N0064JM2/03_EN

Accessing mode configuration 1 2 3 4 Standard mode wiring Phase cut Channel 3 Phase cut Channel 2 Phase cut Channel 1 8

Factory configuration: standard scenario mode Channel 1 Channel 2 Channel 3 Scenario A 100% 100% 100% Scenario B 66% 66% 66% Scenario C OFF OFF OFF Scenario D 33% 33% 33% Standard mode operation Long press on ON (+): Lighting raised to 100% Long press on OFF ( ): Lighting dimmed to 0% Short press on ON (+): Switching on Short press on OFF ( ): Switching off Cabling with 0-10 V ballasts Phase cut Channel 3 Phase cut Channel 2 Phase cut Channel 1 9

Configuration with 0-10 V ballasts + Prog 1, 2, 3 Press + and Prog for the channel. Orange and green configuration LEDs come on, then release. Press briefly on + button, Wait 5 secs. The orange LED flashes. Performance and options with ballasts Control using RGB tubes You can link: - ballasts loaded by red T5 tubes (Philips or Osram T5 tubes ) to channel 1, - green tubes to channel 2, - blue tubes to channel 3. By controlling the RGB proportions, you can create scenarios favouring warm or cool colours or scenarios with dominant colours. The possibilities and results are identical using LED (lights) piloted by 0-10 V ballast Control using white tubes with different hue (T ) You can link: - ballasts loaded by warm white tubes to channel 1, - by cool white tubes to channel 2. By controlling the proportions, you can create scenarios favouring warm (white with colour temperature 3000K) or cool (white with colour temperature 7000K) colours. Dimmer incandescent/fluorescent mixed cabling You can mix channels, for example 1 channel for 0-10 V ballast, 2 channels for incandescent lamp dimmer. Cabling with DALI ballasts 10

Configuration with DALI ballasts + Prog 1, 2, 3 Press + and Prog for the channel Orange and green configuration LEDs come on, then release. Wait for 5 secs. One of the two configuration LEDs comes on steady. Performance and options with DALI ballasts The dimmer can control 3 x 4 DALI ballasts without adding an external DALI power supply. Above 4 ballasts per channel, you have to add a power supply to the DALI standard on the channel. If the channel has a DALI power supply, the maximum number of ballasts is 60. Control using RGB tubes (see page 4) Control using white tubes with different hue (see page 4) Dimmer incandescent/halogen mixed cabling (see page 4) All loads having a DALI input are taken into account. The controller does not have DALI protocol loaded. The addressing remains cabled addressing. The controller enables ballasts to the "DALI standard" to be piloted, but it does not meet the "DALI standard". This function is being able to increase the installed power, or being able to realize a 6-channel pseudo dimmer (see expert cabling). Example: 40 ballasts of 54 W on each of the channels give an installed power of 6480 W. Cabling with DALI ballasts and incandescent or halogen lamp (6-channel dimmer) (expert mode) Channel 6 Channel 5 Channel 4 Phase cut Channel 3 Phase cut Channel 2 Phase cut Channel 1 11

Expert mode configuration (case 1), 6 channels coupled 2 by 2 + Channels 1, 2, 3 (incandescent) and 4, 5, 6 (DALI) are not separated. The +, - controls and scenario controls act on both channels at the same time. - No configuration required, the default mode is operational: - channel 1 is coupled to channel 4 - channel 2 is coupled to channel 5 - channel 3 is coupled to channel 6 Configuration of a dimmer channel with DALI ballasts in expert mode (case 2) +/ON Prog -/OFF Channels 1, 2, 3 (incandescent) and 4, 5, 6 (DALI) are separated. For working in this mode: - Press + and Prog, the two configuration LEDs (orange & green) come on, then release. - Short press on the button. Wait for 5 secs. - To set channels 4, 5, 6 using the + and buttons, press + and for 5 sec. - To return to the settings of channels 1, 2, 3, short press on + and. In this case, use of the + and control buttons is deactivated. Dimming is then only possible using remote control Cat. No. 784 31. To return to Expert mode (case 1), press + and Prog. Scenario setting valid for all modes Operation Scenarios button LEARN indicator light Learn button To set a scenario, open learning by pressing the learn button (the learn LED blinks slowly). Select the scenario by pressing the scene button A, B, C or D (the learn LED blinks fast). Set the scenario by pressing the + and buttons of each channel. Close the leraning process by pressing the Learn button (The Learn indicator light goes out). If learning has not been closed, it will close automatically after 10 minutes without any new save. Default configuration: Channel 1 Channel 2 Channel 3 The lighting controller contains 4 scenarios. If is possible to associate each of the scenarios with one of the buttons on the infrared remote control (784 31). For example, button 1 on the remote control can be associated with scenario A, buttons 2 with scenario B, etc. Scenario A ON ON ON Scenario B 66% 66% 66% Scenario C OFF OFF OFF Scenario D 33% 33% 33% Safety instructions This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation and use can lead to risk of electric shock or fire. Before carrying out the installation, read the instructions and take account of the product s specific mounting location. Do not open up, dismantle, alter or modify the device except where specifically required to do so by the instructions. All Legrand products must be opened and repaired exclusively by personnel trained and approved by Legrand. Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees. Use only Legrand brand accessories. 12