ArteorTM Dimmer 3 x 1000 W / 5740 10/60 Technical characteristics / * ( ) 50/60 Hz 1 x 2.5 mm 2 x 1.5 mm2 2 Max. < 2200 W(2) (do not exceed 1000 W per channel / Special provisions (see page 5) / 240 V~ Min. Max. 3 x 40 W < 1100 W (do not exceed 500 W per channel) / (sum of currents provided by ballasts): 50 ma / 100 V~ Min. Operating current 0-10 V max. / (2) 3 x 20 W Max. inrush current on contact closure at 240 V~: 120 A - 20 ms / * Use only transformers which are intended for use with an electronic switch / Important: See page 4, "Specific intended programming" / ( ) (1) (2) It is expressly forbidden to combine loads with ferromagnetic and with electronic transformers on a same channel / Choice of scenes (A, B, C, D) factory preset, customizable (see page 6). Programming buttons for channels A, B, C LEARN button LEARN indicator light Infrared sensor (Enables remote control using Cat. No. 78431) LE01459AC 3 channels - Switching on and off - Light dimming +/-
Accessing mode configuration 1 2 3 4 Standard mode wiring Phase cut Channel 3 / Phase cut Channel 2 / Phase cut Channel 1 / 2
Factory configuration: standard mode scene Channel 1 Channel 2 Channel 3 Scene A Scene B Scene C Scene D 100% 100% 100% 66% 66% 66% OFF OFF OFF 33% 33% 33% Standard mode operation Long press on ON (+): Lighting dimmed to 100% Long press on OFF ( ): Lighting dimmed to 0% Short press on ON (+): Switching on Short press on OFF ( ): Switching off Cabling with 0-10 V ballasts Phase cut Channel 3 / Phase cut Channel 2 / Phase cut Channel 1 / 3
Configuration with 0-10 V ballasts + Prog 1, 2, 3 Press + and Prog for the channel / Orange and green configuration LEDs come on, then release / Press briefly on + button, / Wait 5 secs. / The orange LED flashes / Performance and options with ballasts Control using RGB tubes / 用 RGB 管控制 You can link: - ballasts loaded by red T5 tubes (Philips or Osram T5 tubes ) to channel 1, - green tubes to channel 2, - blue tubes to channel 3. By controlling the RGB proportions, you can create scenes favouring warm or cool colours or scenes with dominant colours. The possibilities and results are identical using LED (lights) piloted by 0-10 V ballast Control using white tubes with different hue (T ) You can link: - ballasts loaded by warm white tubes to channel 1, - by cool white tubes to channel 2. By controlling the proportions, you can create scenes favouring warm (white with colour temperature 3000K) or cool (white with colour temperature 7000K) colours. Dimmer incandescent/fluorescent mixed cabling You can mix channels, for example 1 channel for 0-10 V ballast, 2 channels for incandescent lamp dimmer. Cabling with DALI ballasts 4
Configuration with DALI ballasts + Prog 1, 2, 3 Press + and Prog for the channel / Orange and green configuration LEDs come on, then release / Wait for 5 secs. / One of the two configuration LEDs comes on steady / Performance with DALI ballasts The dimmer can control 3 x 4 DALI ballasts without adding an external DALI power supply. Above 4 ballasts per channel, you have to add a power supply to the DALI standard on the channel. If the channel has a DALI power supply, the maximum number of ballasts is 60. Control using RGB tubes (see page 4) Control using white tubes with different hue (see page 4) Dimmer incandescent/halogen mixed cabling (see page 4) All loads having a DALI input are taken into account. The controller does not have DALI protocol loaded. The addressing remains cabled addressing. The controller enables ballasts to the "DALI standard" to be piloted, but it does not meet the "DALI standard". This function is being able to increase the installed power, or being able to realize a 6-channel pseudo dimmer (see expert cabling). Example: 40 ballasts of 54 W on each of the channels give an installed power of 6480 W. Cabling with DALI ballasts and incandescent or halogen lamp (6-channel dimmer) (expert mode) Channel 6 Channel 5 Channel 4 Phase cut Channel 3 / Phase cut Channel 2 / Phase cut Channel 1 / 5
Expert mode configuration (case 1), 6 channels coupled 2 by 2 Channels 1, 2, 3 (incandescent) and 4, 5, 6 (DALI) are not separated / + The +, - controls and scene controls act on both channels at the same time. - No configuration required, the default mode is operational: / - channel 1 is coupled to channel 4 / - channel 2 is coupled to channel 5 / - channel 3 is coupled to channel 6 / Configuration of a dimmer channel with DALI ballasts in expert mode (case 2) +/ON & green) come on, then release. / - Short press on the - button. Wait for 5 secs. / Prog -/OFF - To set channels 4, 5, 6 using the + and - buttons, press + and - for 5 sec. / - To return to the settings of channels 1, 2, 3, short press on + and -. / Channels 1, 2, 3 (incandescent) and 4, 5, 6 (DALI) are separated. For working in this mode: / In this case, use of the + and - control buttons is deactivated. Dimming is then only possible using remote control Cat. No. 784 31. / To return to Expert mode (case 1), press + and Prog. / - Press + and Prog, the two configuration LEDs (orange Scene setting valid for all modes To set a scene, open learning by pressing the learn button (the learn LED blinks slowly). / Scene button LEARN indicator light Learn button Channel 1 Channel 2 Channel 3 Select the scene by pressing the scene button A, B, C or D (the learn LED blinks fast). / Set the scene by pressing the + and buttons of each channel. / Close the learning process by pressing the Learn button (The Learn indicator light goes out). / Scene A / ON ON ON Scene B / 66% 66% 66% Scene C / OFF OFF OFF Scene D / 33% 33% 33% If learning has not been closed, it will close automatically after 10 minutes without any new save. / Default configuration: / Safety instructions This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation and use can lead to risk of electric shock or fire. Before carrying out the installation, read the instructions and take account of the product s specific mounting location. Do not open up, dismantle, alter or modify the device except where specifically required to do so by the instructions. All Legrand products must be opened and repaired exclusively by personnel trained and approved by Legrand. Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees. Use only Legrand brand accessories.
ArteorTM 5740 10/60 * ( )
1 2 3 4 8
%100 %100 %100 %66 %66 %66 %33 %33 %33 9
+ Prog 1, 2, 3 10
+ Prog 1, 2, 3 11
+ - +/ON Prog -/OFF Scene button LEARN indicator light Learn button %66 %66 %66 %33 %33 %33