SRF PHOTOINJECTOR TESTS AT HOBICAT

Similar documents
Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

DARK CURRENT IN SUPERCONDUCTING RF PHOTOINJECTORS MEASUREMENTS AND MITIGATION

SRF-gun Development Overview. J. Sekutowicz 17 th September, 2015 SRF15, Whistler, Canada

High Rep Rate Guns: FZD Superconducting RF Photogun

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

News from HZB / BESSY Wolfgang Anders at ESLS-RF Meeting September 2010 Trieste

Design Studies For The LCLS 120 Hz RF Gun Injector

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

STATUS AND COMMISSIONING RESULTS OF THE R&D ERL AT BNL*

Photoinjector Laser Operation and Cathode Performance

Technology Challenges for SRF Guns as ERL Sources in View of Rossendorf work

4.4 Injector Linear Accelerator

SRF GUN DEVELOPMENT OVERVIEW

RF considerations for SwissFEL

Summary of the 1 st Beam Line Review Meeting Injector ( )

Status of BESSY II and berlinpro. Wolfgang Anders. Helmholtz-Zentrum Berlin for Materials and Energy (HZB) 20th ESLS-RF Meeting

TESLA FEL-Report

Technology Challenges for SRF Guns as ERL Source in View of BNL Work

Diamond RF Status (RF Activities at Daresbury) Mike Dykes

Digital BPMs and Orbit Feedback Systems

Dark current and multipacting trajectories simulations for the RF Photo Gun at PITZ

Cathode Studies at FLASH: CW and Pulsed QE measurements

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

New Filling Pattern for SLS-FEMTO

The FLASH objective: SASE between 60 and 13 nm

High QE Photocathodes lifetime and dark current investigation

PoS(EPS-HEP2015)525. The RF system for FCC-ee. A. Butterworth CERN 1211 Geneva 23, Switzerland

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

Results of recent photocathode studies at FLASH. S. Lederer, S. Schreiber DESY. L. Monaco, D. Sertore, P. Michelato INFN Milano LASA

Detailed Design Report

P. Emma, et al. LCLS Operations Lectures

Photo cathode RF gun -

Basic rules for the design of RF Controls in High Intensity Proton Linacs. Particularities of proton linacs wrt electron linacs

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

!"!3

PHIN. Report on the Development of a Radio-Frequency Photo Electron Source with Superconducting Niobium Cavity (SRF Gun Realization)

Status of SOLARIS. Paweł Borowiec On behalf of Solaris Team

The PEFP 20-MeV Proton Linear Accelerator

Current status of XFEL/SPring-8 project and SCSS test accelerator

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Beam Loss Detection for MPS at FRIB

Screen investigations for low energetic electron beams at PITZ

DESIGN OF 1.2-GEV SCL AS NEW INJECTOR FOR THE BNL AGS*

Linac 4 Instrumentation K.Hanke CERN

Summary report on synchronization, diagnostics and instrumentation

Summary of recent photocathode studies

First Results and Future of the Photo Injector Test Facility at DESY Zeuthen PITZ. introduction first measurements future schedule

LHC Beam Instrumentation Further Discussion

LLRF at SSRF. Yubin Zhao

Simulations on Beam Monitor Systems for Longitudinal Feedback Schemes at FLASH.

Bunch-by-bunch feedback and LLRF at ELSA

North Damping Ring RF

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

Low Level RF for PIP-II. Jonathan Edelen LLRF 2017 Workshop (Barcelona) 16 Oct 2017

Operation of CEBAF photoguns at average beam current > 1 ma

Upgrade of CEBAF to 12 GeV

The Elettra Storage Ring and Top-Up Operation

SRS and ERLP developments. Andrew moss

OPERATIONAL EXPERIENCE AT J-PARC

5 Project Costs and Schedule

CLIC Feasibility Demonstration at CTF3

KARA and FLUTE RF Overview/status

ILC-LNF TECHNICAL NOTE

Photocathodes FLASH: Quantum Efficiency (QE)

Precision measurements of beam current, position and phase for an e+e- linear collider

CLIC Feasibility Demonstration at CTF3

STATUS OF THE SUPERCONDUCTING RF PHOTO-INJECTOR DEVELOPMENT*

Accelerator Instrumentation RD. Monday, July 14, 2003 Marc Ross

Status of CTF3. G.Geschonke CERN, AB

Upgrading LHC Luminosity

Characterizing Transverse Beam Dynamics at the APS Storage Ring Using a Dual-Sweep Streak Camera

Activities on FEL Development and Application at Kyoto University

NSLS-II RF Systems James Rose, Radio Frequency Group Leader PAC 2011

RF Design of the LCLS Gun C.Limborg, Z.Li, L.Xiao, J.F. Schmerge, D.Dowell, S.Gierman, E.Bong, S.Gilevich February 9, 2005

PROJECT DESCRIPTION. Longitudinal phase space monitors for the ILC injectors and bunch compressors

Commissioning program of the 704 MHz SRF gun at BNL

Review of Diamond SR RF Operation and Upgrades

PEP II Design Outline

Suppression of Timing drift between laser and electron beam driven photo-cathode RF gun

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

Studies on an S-band bunching system with hybrid buncher

Report on the LCLS Injector Technical Review

SLAC R&D Program for a Polarized RF Gun

Electron linac photo-fission driver for rare isotope program at TRIUMF

Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

IOT Charakterization at BESSY ( HZB)

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

LCLS-II Injector Tuning Procedures. F. Zhou (SLAC) & F. Sannibale (LBNL) 2/6/2017

Status of SOLARIS Arkadiusz Kisiel

A Cathode Development Cornell Cultera This scope includes all labor and purchases required produce photocathodes required by CBETA.

ANKA RF System - Upgrade Strategies

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

The ESS Accelerator. For Norwegian Industry and Research. Oslo, 24 Sept Håkan Danared Deputy Head Accelerator Division Group Leader Beam Physics

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

Transcription:

SRF PHOTOINJECTOR TESTS AT HOBICAT Abstract A. Neumann, W. Anders, R. Barday, A. Jankowiak, T. Kamps, J. Knobloch, O. Kugeler, A. Matveenko, T. Quast, J. Rudolph, S. Schubert, J. Voelker Helmholtz-Zentrum-Berlin, 12489 Berlin, Germany J. Smedley, Brookhaven National Laboratory, Upton, NY, USA J. Sekutowicz, DESY, 2267 Hamburg, Germany P. Kneisel, Jefferson Laboratory, Newport News, VA, USA R. Nietubyc, A. Soltan Institute, Swierk, Poland I. Will, Max-Born Institute, 12489 Berlin, Germany G. Lorenz, Fritz-Haber-Institut der Max-Planck-Gesellschaft, 14195 Berlin, Germany In collaboration with Jefferson Laboratory, DESY and the A. Soltan Institute HZB developed a fully superconducting RF photo-injector as a first step towards a high average current electron source for the BERLinPro ERL. This setup consists of a 1.6 cell superconducting gun cavity with a lead cathode plasma-arc deposited on the half cell backwall and a superconducting solenoid. The system, including a warm diagnostic beam-line section, was recently installed in the HoBiCaT test facility to study beam dynamics within the ERL parameter range. This paper will give an overview of the horizontal cavity tests, dark current studies and beam measurements. INTRODUCTION In the framework of the BERLinPro Energy Recovery Linac project [1] HZB needs to develop a high current CW photoinjector delivering an average beam current of 1 ma at a normalized emittance of 1mm mrad and an exit kinetic energy above 1.5 MeV. This implies the usage of a high quantum efficiency normal-conducting cathodes at highest launch fields possible and a laser repetition rate of 1.3 GHz, filling every RF bucket, such that a CW operated SC photoinjector cavity is mandatory to achieve the required voltage. Thus also a damping of unwanted higher order modes has to be studied and a design has to be found which allows maximum field at strong beam-loading given the RF power constraints of the fundamental couplers. To achieve these challenging goals HZB will follow a three stage approach [2, 3]. The first step is a fully superconducting system of a 1.6 cell cavity, a superconducting lead photocathode and a superconducting solenoid for beam dynamics studies. It is being developed in a collaboration with DESY, Jefferson Laboratory and the A. Soltan Institute. This photoinjector will be used to demonstrate the short-pulse beam dynamics using a SC solenoid in the ERL parameter range. The following two injector systems will feature the insert of a normal conducting cathode including Work supported by Bundesministerium für Bildung und Forschung and Land Berlin Axel.Neumann@helmholtz-berlin.de Table 1: Cavity electromagnetic design parameters Frequency π-mode 13 MHz Frequency -mode 1281 MHz E peak /E cath 1. E peak /E acc (β=1) 1.86 H peak /E acc 4.4 mt/(mv/m) Geometry factor 212 Ω R/Q (linac, β=1) 19 Ω a choke filter system and finally a HOM damping scheme to handle the high average current. This paper will give a first overview about the horizontal cavity tests, dark current studies and beam measurements. Cavity Design and Fabrication The cavity electro-magnetic design is based on a 1.6 cell all SC structure originally designed by Jacek Sekutowicz (DESY) with a lead cathode deposited on the half cell s backwall [4]. The cell shapes are optimized for maximum field on the cathode surface to allow a high launch field to minimize the beam s normalized emittance. Table 1 gives an overview of the figures of merit, Figure 1 shows the field distribution of the TM 1 π-mode calculated by CST MWS TM. The RF design was slightly changed in comparison to [4] to meet the 1.3 GHz and achieve the maximum electric field on the cathode surface. Further the mechanical passive stiffening was optimized by combination of electro-magnetic and mechanical ANSYS TM simulations [5] to reduce microphonics. This was of major importance as the cavity was foreseen without active tuning mechanism. Figure 2 shows the fully assembled gun cavity after fabrication, BCP and high pressure water cleaning, first vertical RF tests and installation of all ancillary components at JLab prior to shipping to A. Soltan institute for the cathode deposition. The manufacturing process is described in more detail in [6]. The 1.6 cells were made from polycrystalline RRR 3 niobium, whereas the halfcell s backwall was machined from large grain niobium with similar purity. After final tuning a field flatness of 94% was measured with a slightly lower field in the half cell. 962 9 Operating experience with SRF accelerators

E z (normalized) 1.8.6.4.2.2.4.6.8 1.5.1.15.2.25.3.35 z (m) Figure 1: Normalized field amplitude E z of the 1.6 cell SC gun cavity. FPC port Pick-up port Stiffening ring Passive stiffening system Large grain Niobium boundary Pb cathode Figure 2: The picture on the left shows the 1.6 cell SC gun cavity after production and assembly of all ancillary components at JLab, the right picture shows the greyish lead cathode on the half cell backwall. The cavity is equipped with a fundamental power coupler port for a TTF-III coupler allowing external Qs from about 1 1 9 down to 6 1 6. This permits the measurement of the intrinsic quality factor at a rather low coupling β c 3...4 while covering the CW beam operating range (1 1 7 to 5 1 6 ) with microphonics. Further a standard TESLA field pick-up probe is installed as well as a stiffening ring and the passive stiffening system by 8 radial niobium bars on the backplate. At the A. Soltan Institute the lead cathode was deposited on the large grain niobium back wall of the half cell by plasma arc deposition. After visual inspection of the lead spot as shown in the right picture of Figure 2, the cavity was sent to JLab again to remove the remnants of the lead deposition from the remaining niobium surface and to define the final cathode diameter by a final BCP and HPR treatment with a special protective mask for the cathode. The cathode has a final diameter of about 5 mm and an estimated thickness of.5 μm. After the final treatment the cavity was sent from JLab to HZB for installation in HoBiCaT and to install the warm diagnostic beamline. Experimental Setup at HoBiCaT Figure 3 displays the entire experimental setup. The gun cavity is installed in the HoBiCaT cryostat directly followed by a vacuum valve and the superconducting solenoid. The first vacuum port is for the pumping station to control the beamline and cavity vacuum. It is followed by the laser port for the UV λ=258 nm cathode laser developed by the Max-Born Institute. This port also has a moveable mirror unit to observe the steering of the laser on the cathode with a CCD camera. Next to the laser port is the first diagnostic port with a moveable YAG viewscreen or a Faraday cup. Further downstream there are a integrating current transformer and a stripline beam position monitor which have not been commissioned so far. At the end of the forward beamline is a viewport foreseen for THz spectroscopy to measure the bunch length and another viewscreen/faraday cup setup. For beam spectroscopy we use a dipole magnet with a dispersive arm. This is also equipped with a viewscreen and a Faraday cup. The cavity was operated with a phase-locked loop setup for the quality factor measurements with pulsed and CW RF methods at rather low β c. For beam operation the cavity was driven via Cornell s LLRF system (see [8], [9]) at a bandwidth from 1-2 Hz with a 4 W solid state amplifier or a 17 kw IOT. To cope with the Lorentz-force detuning during ramping of the field to up to E peak =2 MV/m and to compensate for slow drifts, the piezo tuning signal of the LLRF system was lowpass filtered to steer the master oscillator s frequency via a slow PLL frequency modulation. This same reference frequency was used to synchronize the laser system s internal PLL to the RF to allow fixed-phase particle acceleration. During the measurements the laser was mainly operated at a repetition rate of 8 khz but various pulse energies by changing the pump current of the laser amplifier. The used operating range of the solenoid was up to 1 mt. FIRST HORIZONTAL RF MEASUREMENTS After installation of the cavity and beamline in the Ho- BiCaT shelter the first horizontal RF test was performed to compare these with Q measurements in the vertical test stand at JLab. Figure 4 summarizes the most important measurements. It depicts results before and after laser cleaning of the lead cathode with an excimer kryptonfluoride 248 nm laser. The first vertical test of the fully assembled cavity (without cathode) achieved excellent results with Q 1 1 1 at E peak 35 MV/m with a field emission onset between 35-4 MV/m. The vertical test with the second cathode 9 Operating experience with SRF accelerators 963

SC Solenoid Stripline BPM, ICT THz diagnostics Q SC Cavity Power coupler Dipole magnet Q Faraday Cups HoBiCaT cryostat Viewscreens Figure 3: Overview of the measurement setup for the SC gun cavity tests at HZB including the HoBiCaT cryostat with the cavity and SC solenoid and the warm diagnostic beamline including viewscreen ports, Faraday cups, an ICT and stripline BPM as well as a dipole for energy measurements and the planned Terahertz diagnostics for the bunch length measurement. (a) (b) 1 1 Q Vertical test assembled cavity Vertical test 2 nd lead cathode First horizontal test Horizontal test after 2 nd cooldown Horizontal test after laser cleaning of lead cathode 1 9 5 1 15 2 25 3 35 4 45 E (MV/m) peak Figure 4: Measured unloaded quality factor versus peak electric field after cavity assembly and treatment in the vertical test stand (blue triangles) at JLab, after deposition of the second cathode (blue stars), the first horizontal test after installation and beam line assembly at HZB (black circles), after second cooldown at HZB (black stars) and after laser cleaning of the lead cathode(red diamonds). deposited 1 showed already a degradation of Q down to 1 The first was accidentally lost during the vertical tests and BCP/HPR treatments Figure 5: The pictures show SEM images (taken at FHI) of arc deposited lead samples by A. Soltan Institute similar to the gun cavity cathode. Small surface defects, droplets and tip on tip like structures in the 1-2 μm scale were observed. 5 7 1 9 still allowing peak fields of 3 MV/m with an FE onset at 25 MV/m. The first horizontal measurement at a minimal β c 3 4 showed a further reduction of the Q values down to 4 1 9 with field emission onset at 12 MV/m peak field. The low-field Q was even lower after another cooldown cycle for some maintenances work, possibly the cold cavity collected all residual gas of the beamline during cooldown. After the laser cleaning of the cathode the surface resistance not only recovered to the initial horizontal value, but also the onset of field emission was shifted to a much higher level of 18 MV/m. Laser cleaning resulted in a reduction of the dark current and radiation dose from the cathode, suggesting that some field emitters were removed. From this viewpoint laser cleaning of cavity niobium surfaces might be an in- 964 9 Operating experience with SRF accelerators

7 6 Before first laser cleaning After laser cleaning After high power cleaning 5 I dark (na) 4 3 2 1 12 13 14 15 16 17 18 19 2 21 22 23 E peak (MV/m) Figure 6: Measured dark current versus peak electric field by focussing the dark current with the SC solenoid on the first viewscreen before and after laser cleaning treatment of the cathode. Figure 7: Fit of the Nordheim-Fowler field emission equation to the measured dark current values. The final cleaning was done with the highest power level throughout these measurements. 1 2 teresting option, something we will try in the future. Figure 5 [1] shows a SEM image of arc deposited lead films on a multigrain niobium surface which were produced by the A. Soltan Institute in the same way as the lead cathode. Droplets and tip on a tip like structures [11] on the 1-2 μm scale were detected, possible candidates for strong field emitters. Dark Current and Quantum Efficiency Studies Any kind of dark current by strong field emitters may contribute to beam halo formation downstream in the accelerator beamline and thus be a major source for beam losses in the ERL s return arc. As it is crucial to minimize halo formation and beam loss, dark current characterization is a subject of these investigations. Figure 6 shows an overview of the dark current measured with the first Faraday cup by focussing the beam on the corresponding viewscreen first. The three curves show the average dark current versus E peak at different stages of the gun measurement program, including the laser cleaning. The laser cleaning seemed to shift the field emission onset from 12 MV/m up to 16-17 MV/m. In Figure 7 the Nordheim-Fowler equation [12, 13] Ī F = 5.7 1 12 1 4.52Φ.5 A e (βe ) 2.5 Φ 1.75 (1) exp ( 6.53 19 Φ 1.5 ) βe with ĪF the average current emitted over one RF cycle, Φ the materials work function, A e the emitters effective area, β the field enhancement factor and E the surface electric field in V/m has been fitted to the measured dark current (ln(īe2.5 )(1/E )). Preliminary results show that after the laser cleaning the field enhancement factor was reduced Quantum efficiency 1 3 1 4 1 5 Arc deposited lead (BNL) Gun cathode before laser cleaning Gun cathode after laser cleaning Electro plated lead (BNL) Bulk Niobium (BNL) 1 6 3.5 4 4.5 5 5.5 6 6.5 7 E γ (ev) Figure 8: Comparison of measured quantum efficiency (QE) versus laser pulse energy at BNL [7] of electro-plated, arc-deposited lead and bulk Niobium samples with the QE obtained for the arc-deposited lead cathode of the 1.6 cell cavity before and after laser cleaning. by a factor of three from 626 to 27 while the effective emitting surface increased by a factor of 1. This may hint at sharp tips on the surface being smoothly leveled by the laser cleaning. It was also shown that already the first laser cleaning improved the dark current performance, the following cleaning with even higher laser power did not change its characteristics. Figure 8 shows the measured quantum efficiency (QE) at 258 nm of the lead cathode before and after the laser cleaning. It was improved by a factor of three but is still below the best values achieved with arc deposited lead samples measured by [7]. A typical phase scan of the beam current at E peak =18 MV/m versus the relative launch phase is displayed in Figure 9. This permits the extraction of QE and bunch pulse length information. At best beam currents of 9 Operating experience with SRF accelerators 965

5 14 Beam current 6 Peak field 45 4 12 5 Average current (na) 35 3 25 2 15 E peak (MV/m) 1 8 6 4 4 3 2 I beam (na) 1 5 I beam at E peak =18 MV/m 7 65 6 55 5 45 4 35 3 Relative launch phase (deg) 1 2 2 4 6 8 1 12 14 16 18 2 t (s) Figure 9: Phase scan of the emitted average beam current at E peak =18 MV/m measured with the first Faraday cup at a laser repetition rate of 8 khz. 4 na at 8 khz laser repetition rate could be extracted with pulse lengths varying from σ=3-4 ps. Intense studies of the QE and QE maps of the cathode in dependance of launch phase, laser power, laser spot size and launch field on the cathode were performed and will be presented in the near future in [14]. Further results with the cavity will be also presented in [15]. CAVITY FIELD TRIPS During normal beam operation at different field levels frequent cavity field trips were observed when illuminating specific spots on the cathode with the drive laser. Simultaneously significant electronic activity was observed on the screens. It was shown, that these spots inhibited a stronger fluorescence in the visible range by observing the cathode with the CCD cathode camera (see Figure 12). Though the Faraday cup has a rather low bandwidth sometimes increased average beam currents of above 5 na were measured just in coincidence with a field trip (Figure 1). Measuring the time constant of the transmitted power probe signal during such an event ruled out a cavity trip by a quench of the superconductor (Figure 11). Merely the strong beam current emitted in a short time interval extracts too much energy of the accelerating mode such that the LLRF system cannot supply enough RF power and the field trips within hundreds of ns. To understand this effect and to verify that this may be some kind of laser driven field emission the following measurement was done. The laser pulse energy was stepwise increased from the lowest possible energy where still some current above the resolution limit of the Faraday cup (1 na limited by readout) could be detected. It was shown that below a certain threshold pulse energy no trip occurred. Furthermore, above that level the time after which a trip occurred depended on the laser Figure 1: E peak and average beam current versus time during the observation of cavity field trips at specific cathode positions. Sometimes currents above 5 na were observed. Power probe signal (V).6.5.4.3.2.1 Q L =6.6 1 6 τ=256 ns Measured signal Filtered signal 6 4 2 2 4 6 8 1 12 Time (s) x 1 7 Figure 11: Transmitted power probe signal versus time during a cavity field trip event. The time constant of 256 ns rules out any cavity quench triggered trip. power level (constant rep. rate). Also the beam current was at a level as expected from the QE at these spots, only during the trip the beam current increased to several hundred nanoamperes. Interestingly, the such processed cathode spot showed less fluorescence after this measurement as can be seen in Figure 12 without a significant change of the QE. This will be further analyzed in the future. FIELD STABILITY AND BEAM ENERGY Bunch-to-bunch energy and time jitter of the beam produced by the gun also depends on the field stability of the CW operated cavity. Figure 13 shows a typical microphonics detuning spectrum taken at a peak field level of 2 966 9 Operating experience with SRF accelerators

7 6 7.3 Hz 5 a.) b.) A Δ f (Hz) 4 3 2 46.9 Hz 252 Hz 1 1 1 1 2 1 3 Frequency (Hz) c.) d.) Figure 12: a.) False color picture of the halfcell backwall with the whole cathode visible as a black spot. b.) Laser spot located on a cathode region where cavity trips occur at any extraction phase (magenta spot on yellow surface). c.) Optical photo of the UV cathode laser illuminating the cathode, strong fluorescence can be observed. d.) After several measurements with different laser power on that same cathode location the fluorescence seems reduced. b.)- d.) only show the cathode area. MV/m with the LLRF s ring buffer. Besides strong excitations at about 47 and 7 Hz, where the source is unknown so far, a mechanical eigenmode at 252 Hz was detected. Long term measurements over more than six hours showed an rms detuning between 5-7 Hz and a peak detuning of 25 Hz. As this cavity was not equipped with a tuner, the only way to extract information about the coupled system of the electro-magnetic field and the mechanical system of the cavity cells is to measure the transfer function using dynamic Lorentz-force detuning [16]. The transfer function between the amplitude modulated forward power and the cavity detuning is given in Figure 14. Up to 2 Hz the response is flat, at 25 Hz a group of four mechanical eigenmodes is excited by the sinusoidal varying field amplitude in the cavity. The cavity was operated at peak field levels between 1 and 2 MV/m (E acc =5.5 11 MV/m) at loaded quality factors of 1.4 1 7 down to 6.6 1 6. Table 2 summarizes the measured rms microphonics detuning, the rms phase and relative amplitude stability routinely achieved with the Cornell LLRF system assisted by the slow subhertz PLL frequency correction. The rms detuning seems to be slightly increased at a higher field level, but probably this is mainly due to the increased cavity-loop system bandwidth at the lower Q L. Additionally the pressure sensitivity of the cavity was determined as 114 Hz/mbar, validating the measured value in the vertical test stand of about 1 Hz/mbar [6]. Figure 13: Microphonics detuning spectrum of the gun cavity in CW operation at Q L = 6.6 1 6. The line at 252 Hz is an excited mechanical resonance which was measured by dynamic lorentz force detuning excitation. Detuning (Hz) Phase lag (deg) 2 15 1 5 2 15 1 5 5 1 Lorentz force detuning transfer function 5 1 15 2 25 3 Field modulation frequency (Hz) 5 1 15 2 25 3 Field modulation frequency (Hz) Figure 14: Dynamic Lorentz-force detuning transfer function in detuning amplitude versus forward power modulation frequency (upper plot) and phase response. A group of four strong mechanical eigenmodes was found at around 25 Hz. Beam Energy The beam s kinetic energy was measured by the dispersive section of the beam line using the dipole current and the Faraday cup signal maximized crosschecked with the YAG viewscreen to determine the position of the maximum of the beam distribution. Figure 15 displays two scans of the beam energy over launch phase at 12 and 2 MV/m field at the cathode. To understand the longitudinal beam dynamics, especially to learn how to improve the RF de- 9 Operating experience with SRF accelerators 967

Table 2: Cavity field stability E Q peak σ f σ Φ L (MV/m) (Hz) (deg) σ A /A 1.4 1 7 12. 5.2.2 1.5 1 4 6.6 1 6 2. 7..17 1.2 1 4 E kin MeV 2 1.8 1.6 1.4 1.2 1.8.6.4.2 New solenoid setting Sim. 12 MV/m Dipol scan 12 MV/m ASTRA 12 MV/m Dipol scan 2 MV/m Dipol scan 2 MV/m Dipol scan 2 MV/m Sim. 2 MV/m 1 2 3 4 5 6 7 8 9 1 11 12 Phase (degr.) Figure 15: Measured beam kinetic energies for 12 and 2 MV/m launch field versus phase compared to ASTRA and longitudinal tracking simulations. sign for the future BERLinPro gun cavity, the result was reconstructed with a self written longitudinal tracking code and ASTRA [17] simulations. It was not fully possible to reconstruct the curvature of the measurement which did not show the small local maximum at a phase of about 3 degrees for 2 MV/m, even when taking into account the imperfect field flatness. For the next measurements a careful calibration of the dipole and the cavity field is foreseen. OUTLOOK First measurements of the beam s normalized emittance and the thermal emittance of the lead cathode have been started, as well as studies of bunch length in the presence of space charge effects. These measurements will be further pursued late summer this year and first results will be published in [14]. Recently the cryostat was warmed up again to improve the diagnostics capabilities of the beamline and the alignment of the cavity to the solenoid. This will allow a more accurate measurement of the emittance and to start studies about the beam energy spread and jitter. Further the cavity trip events will be studied in more detail. Lessons learned with this cavity will be incorporated in the RF design of the future BERLinPro injector cavity, optimizing the cavity shape for higher launch phases. REFERENCES [1] M. Abo-Bakr et al., BERLinPro- An Accelerator Demonstration Facility for ERL-based Light Sources, Proc. of the 25 th LINAC (21), Tsukuba, Japan, [2] T. Kamps et al., SRF Gun Development for an Energy-Recovery Linac based Future Light Source, Proc. of the 14 th SRF Conference (29), Berlin, Germany, [3] T. Kamps et al., Status and perspective of superconducting radio-frequency gun development for BERLinPro, Journal of Physics: Conference Series, 298 (211), http://iopscience.iop.org/1742-6596. [4] J. Sekutowicz, A. Muhs, P. Kneisel, R. Nietubyc, Cryogenic Test of the Nb-Pb SRF Photoinjector Cavities, Proc. of the 23 rd PAC (29), Vancouver, Canada, [5] A. Neumann et al., CW Superconducting RF Photoinjector Development for Energy Recovery Linacs, Proc. of the 25 th LINAC (21), Tsukuba, Japan, [6] P. Kneisel et al., Fabrication, Treatment and Testing of a 1.6 Cell Photo-injector Cavity for HZB, Proc. of the 24 th PAC (211), New York, USA, [7] J. Smedley et al., Lead photocathodes, PRST-AB, Volume 11, No. 1, 28, DOI: 1.113/PhysRevSTAB.11.1352. [8] M. Liepe et al., Experience with the New Digital RF Control System at the CESR Storage Ring, Proc. of the 21 st PAC (25), Knoxville, USA, [9] A. Neumann et al., CW Measurements of Cornell LLRF System at HoBiCaT, these proceedings. [1] R. Barday et al., Instrumentation needs and solutions for the development of an SRF photoelectron injector at the Energy-Reocvery Linac BERLinPro, Proc. of the 1 th DI- PAC (211), Hamburg, Germany, [11] H. Padamsee, J. Knobloch, T. Hays, RF Superconductivity for Accelerators, Wiley-VCH, Second Edition, Weinheim, Germany, 28. [12] R.H. Fowler, L. Nordheim, Electron Emission in Intense Electric Fields, Proc. R. Soc. Lond. A May 1, 1928 119:146-156; [13] J.H. Han et al., Dark current measurements at the PITZ RF Gun, Proc. of the 6 th DIPAC (23), Mainz, Germany, [14] T. Kamps et al., Demonstrating electron beam generation and characterization with an all superconducting radiofrequency photoelectron source, Proc. of the 2 nd IPAC (211), San Sebastián, Spain (to be published). [15] A. Neumann et al., First characterization of a fully superconducting RF photoinjector cavity, Proc. of the 2 nd IPAC (211), San Sebastián, Spain (to be published). [16] A. Neumann, Compensating microphonics in SRF Cavities to ensure beam stability for future Free-Electron-Lasers,Phd thesis, Humboldt Universität Berlin, Germany, 28. [17] K. Flöttmann, A Space Charge Tracking Algorithm (AS- TRA), http://www.desy.de/ mpyflo/. 968 9 Operating experience with SRF accelerators