Panel-mounting Thermostats EM Series

Similar documents
Surface-mounting thermostats ATH series

Panel-Mounted Thermostat

Panel-mounting thermostats, type series EM

Heating thermostat Series AMHs B Operating Instructions 11.06/

Surface-mounting thermostat, type series ATH.-SE to monitor seagoing vessel equipment

Surface-mounting thermostat, type series ATH.-SE

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Bimetal Temperature Switch

TUC: Universal thermostat

Max. temp. of sensor C. Capillary tube mm. Switching difference K. Sensor cartridge mm

Single Point Flow Monitor SW118 SW119

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Panel-mounted Thermostats

Mechanical flow switch for On/Off control

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Level Measurement silometer FMC 420, FMC 423

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

82540/ /2-way diaphragm valves

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Pendant Light Fitting IEC Series 6470/2

Flexibility and Safety. BERNSTEIN safety hinge switches

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Inductive sensor BI1.5-EG08K-Y1

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

DMP 331i / DMP 333i LMP 331 i

Capacitance Limit Detection nivotester FTC 420/421/422

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

Inductive sensor NI10-M18-Y1X-H1141

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

Pressure transmitter COMPACT IO-Link,

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Gear Pump Units For single-line centralized lubrication systems

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Nessie Coils for VDH and VDHT valves

Inductive sensor NI3-EG08K-Y1-H1341

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Magnetic Stirrers Magnetic Stirr

Connecting cables NEBS, for sensors

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Part-Turn Electric Multi-Turn Electric

7 Lighting Technology

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

Gear Pump Units. For single-line lubrication systems

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Explosion protected add-on thermostat

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Process transmitter RMA422

KRF EMC Filters Installation, Operation and Maintenance Manual

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

2.9 Sigma/ 2 Plunger Metering Pumps

ALLEN BRADLEY TIMING RELAY

Pulse Counters, electromechanical

Inductive sensor With analog output BI15-M30-LI-EXI


1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Read/Write Head TN-M30-H1147

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100


Linear flow control with actuator IFC

Figure 1: Device components

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Linear flow controls VFC Linear flow controls with actuator IFC

Gamma instabus. Technical product information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

LED Driver Compact dimming

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Circuit-Breakers for Motor Protection Series 8523/8

APPLICATIONS. Automatic warehouse. Trasportation lines

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Selection matrix for electronic pressure switches

SQM40/41 Actuators for air and gas dampers

Read/write head TN-M18-H1147

Solenoid valves VZWD, directly actuated

SERIES 400 SERIES 620

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Series CT7N Bimetallic Overload Relays

ES-Mega MegaBeans. Access Control System. User Manual. People in Motion

Operating instructions

Pulse Counters, electronic

APPLICATIONS. Automatic warehouse. Trasportation lines

02/11/2015

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

Pressure transmitter For applications in hazardous areas Model IS-3

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Transcription:

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Panel-mounting Thermostats EM Series with, 2, 3 or 4 single-pole snap-action switches Brief description Thermostats control and monitor thermal processes. EM series instruments can be supplied as controllers TR, monitors TW, limiters TB, safety monitors STW (STB) and protection limiters STB. In fault condition, the STB sets the system being monitored to a safe operational state. Panel-mounting thermostats operate on the principle of liquid expansion, with a micro- switch serving as the electrical switching device. Switching action Temperature controller TR and monitor TW When the at the probe exceeds the selected setpoint, the microswitch is actuated through a mechanism and the circuit is opened or closed. When the drops below the selected setpoint (by the amount of the switching differential), the micro- switch returns to its initial position. Lock-out facility on the limiter TB and protection limiter STB When the at the probe exceeds the set limit, the circuit is opened and the miroswitch locked out mechanically. After the has dropped below the critical by about 0 % of the scale span (approx. % for a limit setting above +30), the microswitch can be reset manually. With limits above 20, the limit setting on the STB must be locked (e.g. by a seal) to prevent any shift. Self-monitoring facility on the protection limiter STB and safety monitor STW (STB) In the case of the STB and STW (STB), any failure of the measuring system, i.e. a leakage of the expansion liquid, will cause the pressure under the diaphragm to drop, thus permanently opening the circuit. Resetting is now impossible. When the at the probe drops below -20 (approx.), the circuit will also open, but will close again automatically when the rises above -0. Use of the safety monitor STW as a protection limiter STB The circuitry to which the thermostat is connected must comply with DIN 3440 and VDE 06. Approvals DVGW Gas Appliances Directive 90/396/EEC Type EM-0 only Pressure Equipment Directive 97/23/EC CE0036 only Types EM-20 EM-30 EM-40 EM-0 only Types EM- EM-2 EM-4 EM-0

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 2/2 Types and DIN registration numbers Version single-pole snap-action switch 2 single-pole snap-action switches 3 single-pole snap-action switches 4 single-pole snap-action switches Type EM- EM-2 EM-3 * EM-4 * EM- EMF-3 EMF-23 EMF-33 * EMF-4 EMF-24 EMF-44 * EMF-4 EMF-33 EMF-34 EMF-233 EMF-234 EMF-333 * EMF-444 * EMF-44 EMF-333 EMF-2333 EMF-3333 * Fail-safe version EM-40 * EM-0 EM-20 EM-30 * Switching action of the individual contacts (see example ) TR TW TW TB TB TR / TW TW / TW TW / TW TR / TB TW / TB TB / TB TB / TB TR / TW / TW TR / TW / TB TW / TW / TW TW / TW / TB TW / TW / TW TB / TB / TB TB / TB / TB TR / TW / TW / TW TW / TW / TW / TW TW / TW / TW / TW STB STB STW (STB) STW (STB) DIN Reg. No. TR 77703 TW 77803 TW 77903 TB 78003 TB 7803 TR 77703 TW 77803 TW 77903 TR 77703 TW 77803 TB 78003 TB 7803 TR 77703 TR 77703 TW 77803 TW 77803 TW 77903 TB 78003 TB 7803 TR 77703 TW 77803 TW 77903 STB 78203 STB 78303 STW (STB) 7703 S STW (STB) 77603 S Important note DIN approved up to 0 max. The DIN Reg. No. becomes invalid if pockets are used that are not listed in our Data Sheet 60.670. Type EM-0 DVGW Reg. No. CE-008 AR 024 *Setpoint / limit permanently set at the factory to customer requirements Technical data Table of control ranges and probes for TR, TW, TB liquid-filled Control/limit range Switching differential % -20 to 40,0 2.,0 7,0-20 to 0,0 2.,0 7,0 +20 to 90,0 2.,0 7,0 +20 to 0,0 2.,0 7,0 +30 to,0 2.,0 7,0 +30 to,0 2.,0 +30 to +200,0 2. to +200,0 2. to +20,0 2.,0 to +300,0 2. probe 0 0 9 0 60 60 + + +40 +7 +2 +2 +6 +200 +3 +3 +70 +200 +73 +73 +200 +230 +230 +230 +230 +228 +228 +300 +34 +34 switch head capillary length m 0 (00) 0) 0 (00) 0) 0 (80) ) 0 (80) ) 60 (00) 0) 60 (00) 0) 60 (80) ) 60 (80) ) 0 (00) 0) 0 (00) 0) 0 (00) 0) 0 (00) 0) 0 (00) 0) 0 (00) 0) 0 (00) 0) 3 3 2 2 2 2 contact spacing 00 008 02 00 00 00 02 00 007 04 03 070 00 020 00 00 008 06 040 080 0 030 07 0 (00) 0) 0 (00) 0) 020 040 0 (00) 0) 0 030 020 0 (00) 0) 040 0 (00) 0) 00 0 (00) 0) 2 02 00 Probe length L in mm, probe dia. d in mm, 6 mm dia. is standard Ø 6 Ø 8 24 24 38 03 283 283 9 7 20 20 2 09 7 7 094 073 88 88 0 084 3 3 072 4 4 09 073 6 6 0 080 27 27 082 067 00 00 068 08 6 6 076 063 078 078 07 3 078 39 092 0 0 064 070 070 049 087 06 ) Values in brackets to special order only, taking into account operating conditions and capillary lengths

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 3/2 Technical data Table of control ranges and probes for TR, TW, TB gas-filled Control/limit range Switching differential % +20 to +400 06 0 +20 to 0 3 / 06 0 probe +460 0 +30 +7 +7 switch head 0 0 80 0 0 capillary length m contact spacing 07 200 048 09 20 Probe length L in mm, probe dia. d in mm, 6 mm dia. is standard Ø 6 Ø 8 237 37 27 08 278 76 09 8 06 06 Control ranges and probes for STB and STW (STB) liquid-filled Setting range Scale span probe +7 to 0 78 +2 +8 to 78 +3 +20 to 77 +73 +60 to +200 79 +230 +20 to +20 7 +288 +20 to +300 79 +34 switch head capillary length m 0 Tolerance at limit -7-7 -9-2 -3-6 Probe length L in mm, probe dia. d in mm, 6 mm dia. is standard Ø 6 Ø 8 84 63 80 7 64 49 6 47 Control ranges and probes for STB and STW (STB) gas-filled Setting range Scale span probe +300 to +400 70 +460 +30 to 0 72 +7 switch head capillary length m 0 3 Tolerance at limit -23-29 Probe length L in mm, probe dia. d in mm, 6 mm dia. is standard Ø 6 Ø 8 48 92 27 8 On thermostats with factory-set switching points, please specify the switch-off point in addition to the control range, e.g. control range +80 to 0, fixed at +9. Capillaries and probes Type End of scale Capillary Temperature probe Notes EM-.. up to 200 copper (Cu) copper (Cu).mm dia. Mat. Ref. Cu-DHP Mat. Ref. Cu-DHP brazed Capillary length Min. bending radius of capillary up to 30 up to 00 up to 30 copper (Cu).mm dia. Mat. Ref. Cu-DHP stainless steel (CrNi).mm dia. Mat. Ref..47 stainless steel (CrNi).mm dia. Mat. Ref..47 stainless steel (CrNi) Mat. Ref..47 brazed stainless steel (CrNi) Mat. Ref..47 welded stainless steeel (CrNi) Mat. Ref..47 welded standard: 000 mm, max. 000 mm Note If the maximum permissible at the probe, capillary and switch head is not fully utilized, it may be possible to increase the capillary length there where it is restricted to, 2 or 3 m according to the control range and probe table. Please let us know the actual s to which the thermostat is exposed. mm at extra cost

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 4/2 Electrical data Switching device:, 2, 3 or 4 single-pole snap-action switches Contact rating Contact reliability Rated surge voltage Overvoltage category Required fusing Electrical connection Operating data Switching differential in % of control/limit range Contact spacing on multi-pole thermostat EM.-... EM.-2... EM.-3... EM-20 EM-30 microswitch with changeover contact switching action switching differential EM.-4... EM.-... EM-40 EM-0 microswitch with (n.c.) break contact and lock-out (n.c.) break contact terminal 2 TR, TW, STW (STB) 2,%, %, 6%, 7%, 0% 6 (3) A, 230 V AC % p.f. = (0.6) 0.2 A, 230 V DC % TB, STB TR, TW %, 3% TR, TW 2.% EM.-4.../U EM.-.../U EM-40/U EM-0/U microswitch with (n.c.) break contact, lock-out and additional signal contact (n.o.) make contact terminal 4 8 (.) A, 230 V AC % p.f. = (0.6) 0.2 A, 230 V DC % 2 () A, 230 V AC % p.f. = (0.6) 0.2 A, 230 V DC % 6 (2) A, 230 V AC %, p.f. = (0.6) 0.2A, 230 V DC % microswitch, gold-plated, extra code au 0. A, 24 V AC/DC To ensure the maximum switching reliability, we recommend a minimum load of: with silver contacts: with gold-plated contacts (code au ): AC/DC = 20 ma, 24 V AC/DC = 0 ma, 0 V 00 V (400 V via the switching contacts) II see Contact rating standard faston connectors A 6.3 x 0.8 DIN 46 244 extra code X screw terminal up to 2. mm 2 conductor cross-section (at extra cost) also suitable for retrofitting Switching action with liquid-filled system Nominal value Possible actual value TR, TW 2. 2. max. 3. standard max. 6 on request 7 7 max. 8 on request max. 2 at extra cost with gas-filled system max. standard 6 6 max. 4 on request 0 0 max. 6 on request 3 2. max. 4 at extra cost STW (STB) with liquid-filled system max. 7 standard with gas-filled system 6 6 max. 6 standard with switching differential contact spacing of scale span switching point accuracy of contact spacing of minimum maximum scale span % % according to % 2.% % control range table % 3%, % 2% <2% 6%, 7%, 0% 3% <3% The contact spacing is specified in against the setpoint of contact I. (The contact number is marked on the back of the housing.) sign - = switching before the setpoint sign + = switching after the setpoint For simultaneous switching, specify contact spacing 0.

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Operating data Switching point accuracy in % of control /limit range Mean ambient effect Temperature compensation* (TK) Temperatures Nom. position (NL) Switching action TR %, 2.% % 7% TW %, 2.% % 7% Switching differential liquid-filled gas-filled 3%, % 6%, 0% 3%, % 6%, 0% in upper third of scale or at limit ±.% ± 3,0% ± 4,0% / -3% / -6% / -8% TB % -% STB, STW (STB) see table of control ranges and probes, page 3 Deviation of the ambient at the switch head and/or capillary from the +22 calibration ambient produces a switching point shift: higher ambient = lower switching point lower ambient = higher switching point for s with end of scale/limit < 200 200 30 400 00 TR, TW, TB STW STB TR, TW, TB STW STB TR, TW, TB STW, STB switching differential in % /2. 7 7/-- /2. 7/-- 3/ 6 0 ambient effect on switch head, % per 0. 0.26 0.34 0.43 0.2 0.2 0.3 0.2 0.7 0.24 ambient effect on capillary, % per per m length 0.0 0.09 0.04 0.07 0.0 * for detailed information, see diagram on page 8 permissible storage : permissible ambient in operation: -0 to +80 max. unrestricted Housing Housing in standard fixing by 2 M3 screws, spaced 22 mm galvanized steel code b by 2 M4 screws, spaced 28 mm sheet code b2 by 2 M3 screws, spaced 33 mm code b7 central fixing M 0 x with cap nut (on TB and STB only) Setpoint adjustment TR: TW, TB, STB, STW (STB): switching point externally adjustable by rotary knob switching point adjustable with screwdriver Types EM-3, EM-4, EM-33, EM-44, EM-444, EM-3333, EM-30, EM-40 permanently set at the factory to customer requirements Setpoint knob see Data Sheet 60.67 Scale span standard: 20 (for STB and STW (STB), see table of control ranges and probes, page 3) Protection EN 60 29-IP00 Weight approx. 0.3 kg Process connection* EM Series with capillary plain cylindrical probe A (standard) pocket U (on request) screw-in pocket with screw-in spigot G /2 Form A to DIN 382/2 and clamping clip with fixing screw for securing the probe Material pocket U up to : CuZn is standard above : St is standard (CrNi on request) Fitting length S standard lengths: 00, 20, 0, 200 or 300 mm (other lengths on request) Immersion tube dia. D = 8 mm, D = 0 mm *See Data Sheet 60.670 for additional process connections and pockets.

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 6/2 Connection diagrams EM- EM-2 EM-3 EM-4 EM- EMF-3 EMF-23 EMF-33 EM-4/U EM-/U Setpoint: I Follow-on contact: II EMF-33 EMF-233 EMF-333 Setpoint: I Follow-on contact: II, III EM-40 EM-0 I =break contact on system fracture and T < -0: I II =limit: II ϑ II 2 4 I EMF-333 EMF-2333 EMF-3333 Setpoint: I Follow-on contact: II, III, IV EM-40/U EM-0/U I =break contact on system fracture and T < -0: I II =limit: II Example: EMF-334 For other type variants, the connection diagrams have to be appropriately combined. EM-20 EM-30 I =break contact on system fracture and T < -0: I II =limit: II II 2 4 4 I Dimensions EM- EM-2 EM-3 EM-4 EM- B G standard 22 M3 code b 28 M4 code b2 33 M3

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 7/2 EMF-3 EMF-23 EMF-33 EMF-4 EMF-24 EMF-44 EMF-4 B G standard 22 M3 code b 28 M4 code b2 33 M3 EMF-33 EMF-34 EMF-233 EMF-234 EMF-333 EMF-444 EMF-44 B G standard 22 M3 code b 28 M4 code b2 33 M3 EMF-333 EMF-2333 EMF-3333 B G standard 22 M3 code b 28 M4 code b2 33 M3

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 8/2 Screw connection EM- extra code X Temperature compensation (TK) Any deviation of the at the switch head from the +22 calibration ambient will produce a deviation of the switching point. With strongly fluctuating ambient s it makes sense to use thermostats with compensation (extra code TK). Switching point deviation as a function of ambient at the switch head, taking into account the switching differential. The effect on the capillary has not been allowed for and may introduce an additional error. Version without compensation end of scale < +200 EM -pole / EM 2-pole Version with compensation EM -pole TK Note: Additional graphics of the compensation TK with higher end-of-scale values and for the EM 2-pole version are available on request. Note Physical and toxicological properties of the expansion media that may escape in the event of a system fracture. Control range with end of scale Dangerous reactions Fire/explosion hazard Ignition Explosion limit % v/v Water contamination irritant At present there is no restrictive statement from the health authorities concerning any danger to health over short periods and at low concentration, e.g. after a fracture of the measuring system. Toxicological data danger to health < +200 no + 3 0.6 0.8 yes yes no 200 +30 no + 490 - - yes yes no > 30 0 no no no no no no no toxic

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 9/2 Stock items (delivery: 3 working days after receipt of order) Sales No. Type Control range Switching differential % Capillary mm Connection Probe dia. x length mm 60/600023 EM- - 20 to + 40 2. 2000 A 6x24 60/60000492 EM- 0 to + 0 2. 000 A 6x283 60/600042 EM- + 20 to + 90 2. 000 A 6x20 60/60000493 EM- + 20 to + 90 7.0 000 A 6x 9 60/600002 EM- 0 to 0.0 000 A 6x7 60/60000494 EM- 0 to 0 2. 000 A 6x7 60/6000029 EM- 0 to 0 2. 2000 A 6x7 60/6000028 EM- + 30 to 7.0 000 A 6x 84 60/6000092 EM- 0 to 2. 000 A 6x3 60/6000027 EM- 0 to 2. 2000 A 6x3 60/60004 EM- 0 to +200 2. 000 A 6x4 60/60000220 EM- 0 to +200 2. 2000 A 6x4 60/6000026 EM- + 0 to +20 2. 2000 A 6x06 60/6000049 EM- + 0 to +300 2. 000 A 6x 88 60/60000923 EM- + 0 to +300 2. 2000 A 6x 88 60/600029 EM- + 20 to +400 6.0 000 A 8x37 60/60002083 EM- + 20 to 0.0 000 A 8x9 60/6000024 EM-2 0 to + 0 2. 000 A 6x286 60/60000497 EM-2 0 to 2. 000 A 6x3 60/6000023 EM-2 0 to 2. 2000 A 6x3 60/6000380 EM-2 + 0 to +300 2. 000 A 6x 88 60/6000220 EM-2 + 20 to +400 6.0 000 A 8x37 60/60002084 EM-2 + 20 to 0.0 000 A 8x9 60/600022 EM-2 +20 to 0 6.0 2000 A 8x9 60/60000924 EM- 0 to 2. 000 A 6x3 60/60000929 EM- 0 to +200 2. 000 A 6x4 60/600002 EM- + 0 to +300 2. 000 A 6x 88 60/6000208 EM- + 20 to 0 4.0 000 A 8x9 60/60002244 EM-0/U,b7 +300 to +400 000 A 6x48 60/6000224 EM-0/U,b7 +30 to 0 000 A 6x27

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 0/2 Order details for non-stock items: Panel-mounting thermostats EM Series Order code () Basic type 60202 EM panel-mounting thermostat with microswitch, with capillary (2) Basic type extension 000 EM- Temperature controller TR 0002 EM-2 Temperature monitor TW 0003 EM-3 * Temperature monitor TW -pole 0004 EM-4 * Temperature limiter TB 000 EM- Temperature limiter TB 003 EMF-3 Temperature controller TR / TW 0023 EMF-23 Temperature monitor TW / TW 0033 EMF-33 * Temperature monitor TW / TW 004 EMF-4 Temperature controller TR / TB 2-pole 0024 EMF-24 Temperature monitor TW / TB 0044 EMF-44 * Temperature limiter TB / TB 004 EMF-4 Temperature limiter TB / TB 033 EMF-33 Temperature controller TR / TW / TW 034 EMF-34 Temperature controller TR / TW / TB 0233 EMF-233 Temperature monitor TW / TW / TW 0234 EMF-234 Temperature monitor TW / TW / TB 3-pole 0333 EMF-333 * Temperature monitor TW / TW / TW 0444 EMF-444 * Temperature limiter TB / TB / TB 044 EMF-44 Temperature limiter TB / TB / TB 333 EMF-333 Temperature controller TR / TW / TW / TW 2333 EMF-2333 Temperature monitor TW / TW / TW / TW 4-pole 3333 EMF-3333 * Temperature monitor TW / TW / TW / TW 0020 EM-20 Safety monitor STW (STB) 0030 EM-30 * Safety monitor STW (STB) 0040 EM-40 * Protection limiter STB 000 EM-0 Protection limiter STB * setpoint/limit permanently set at the factory to customer requirements (3) Control/limit ranges for TR, TW and TB 03 0-20 to 40 02 0-2 0 to 0 04 20 to 90 02 00 to 0 02 30 to 027 0+30 to 028 0+30 to +200 062 0 to +200 063 0 to +20 064 0 to +300 04 20 to +400 046 20 to 0 for STB and STW (STB) 07 7 to 0 08 8 to 090 +20 to 09 +60 to +200 092 +20 to +20 094 +20 to +300 09 +300 to +400 096 +30 to 0 000 for limits with fixed settings

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Order details for non-stock items: Panel-mounting thermostats EM Series Order code (4) Limits with fixed settings 000 for adjustable control/limit ranges... values in (must be within the control/limit ranges) () Switching differential 00 no switching differential (-40 STB, -0 STB) 0 % * of scale span 2 2.% * of scale span 0 % ** of scale span with liquid-filled systems 70 7% ** of scale span 30 3% * of scale span 0 % ** of scale span 60 6% * of scale span with gas-filled systems 0 0% * of scale span ** on TR + TW only ** on TR, TW and STW only (6) Capillary length 000 000 mm 2000 2000 mm 3000 3000 mm 4000 4000 mm 000 000 mm.... (special length, details in plain text) (7) Material of capillary 40 Cu (copper) 20 CrNi (stainless steel.47) (8) Process connection* 0 A = plain cylindrical probe 20 U = screw-in pocket * for other probe mountings and pockets, see Data Sheet 60.670. (9) Thread of process connection 00 no thread (process connection A) 3 male thread G / 2 (0) Material of process connection 00 only with process connection A 46 CuZn (brass) 0 St (steel) 20 CrNi (stainless steel.47) () Fitting length S (immersion tube length) 000 no pocket 00 00mm 0 0mm 200 200mm 300 300mm 400 400mm.... (special length, details in plain text)

Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page 2/2 Order details for non-stock items: Panel-mounting thermostats EM Series Order code (2) Diameter D (immersion tube diameter) 00 no pocket 08 08 mm 0 0 mm (3) Diameter d (probe diameter) 6 6 mm 8 8 mm (4) Extra codes** 74 U TB/STB with (n.c.) break contact, lock-out and additional signal contact 702 ausnap-action switch contact, gold-plated (only on - and 2-pole version) 699 X screw connection up to 2. mm 2 conductor cross-section 704 bswitch head fixing by 2 M4 screws, spaced 28 mm 70 b2switch head fixing by 2 M3 screws, spaced 33 mm 70 b7central fixing with cap nut (on TB and STB only) 707 TK compensation (for - and 2-pole version only) **List extra codes in sequence, separated by commas Contact spacing for 2-, 3- and 4-pole termostats details in plain text (e.g. +2, +, +8) Order code () (2) (3) (4) () (6) (7) (8) (9) (0) () (2) (3) (4) 60202 /.... -... -... -.. -.... -.. -.. -.. -.. -... -.. -. /...,...,... Order example 60202 / 000-02 - 000-00 - 2000-40 - 0-00 - 00-000 - 00-6 / 74**, 70 ** List extra codes in sequence, separated by commas.